• Title/Summary/Keyword: 가상인체

Search Result 170, Processing Time 0.031 seconds

The Application of Chamfer Matching Algorithm to the Error Analysis of a Treatment Field between a Simulation Image and a Portal Image (챔퍼 매칭(Chamfer Matching) 알고리즘을 활용한 모의치료 영상과 포탈(Portal) 영상의 비교, 분석)

  • 송주영;나병식;정웅기;안성자;남택근;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.189-195
    • /
    • 2003
  • The comparative analysis of a portal image and a simulation image is a very important process in radiotherapy for verifying the accuracy of an actual treatment field. In this study, we applied a chamfer-matching algorithm to compare a portal image with a simulation image and verified the accuracy of the algorithm to analyze the field matching error in the portal image. We also developed an analysis program that could analyze the two images more effectively with a chamfer-matching method and demonstrated its efficacy through a feasibility study. With virtual portal images, the accuracy of the analysis algorithm were acceptable considering the average error of shift (0.64 mm), rotation (0.32$^{\circ}$), and scale (1.61%). When the portal images of a head and neck phantom were analyzed, the accuracy and suitability of the developed analysis program was proven considering the acceptable average error of shift (1.55 mm), rotation (0.80$^{\circ}$), and scale (1.72%). We verified the applicability of a chamfer-matching algorithm to the comparative analysis of a portal image with a simulation image. The analysis program developed in this study was a practical tool to calculate the quantitative error of the treatment field in a portal image.

  • PDF

Assessment of subjective symptoms by 60Hz magnetic field in electromagnetic hypersensitivity (60Hz 자기장에 대한 과민 증후군의 자각증상 원인 평가)

  • Yang, Dong-In;Nam, Ki-Chang;Kwon, Min-Kyung;Kim, Deok-Won
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.721-732
    • /
    • 2010
  • As increasing of electrical device usage, social concerns about the possible effects of 60Hz electromagnetic fields (EMF) on human health have increased. The number of people with self-attributed electromagnetic hypersensitivity (EHS) who complain of subjective symptoms such as headache, insomnia etc. also increased. However, we don't know whether the EHS results from psychological factor or real perception to the electromagnetic field. In this study, we simultaneously investigated physiological changes(heart rate, respiration rate, heart rate variability, alpha and beta waves in EEG), subjective symptoms and perception accuracy to assess origins of subjective symptoms according to the EMF exposure. Experiment consists of real and sham sessions and 60Hz 12.5uT magnetic field was on(real) or off(sham) to 15 EHS and 16 nonEHS. As the results, EMF exposure did not have any effects on physiological parameters or subjective symptoms for both groups. There was also no evidence that EHS group perceived the EMFs correctly than the control group. Therefore, the origins of subjective symptoms is not the 60Hz magnetic field but psychological factors.

  • PDF

Contaminated Surfaces in an Urban Environment (도시환경에서 방사능오염 표면의 중요도 분석)

  • Hwang, Won-Tae;Jeong, Hyo-Joon;Kim, Eun-Han;Han, Moon-Hee;Ahn, Min-Ho;Kim, In-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.148-153
    • /
    • 2011
  • EMRAS-2 (Environmental Modelling for RAdiation Safety, Phase 2) is an international comparison program, which is organized by the International Atomic Energy Agency (IAEA), in order to harmonize the modelling of radionuclide behavior in the environment. To do so, the urban contamination working group within EMRAS-2 has designed the hypothetical scenarios for a specified urban area. In this study, the importance of contaminated surfaces composing an urban environment was analyzed in terms of dose rate using METRO-K, which has been developed to take a Korean urban environment into account. The contribution of contaminated surfaces to exposure dose rate showed distinctly a great difference as a function of specified locations and time following a hypothetical event. Moreover, it showed a distinct difference according to the existence of precipitation, and its intensity. Therefore, if an urban area is contaminated radioactively by any unexpected incidents such as an accident of nuclear power plants or an explosion of radioactive dispersion devices (RDDs), appropriate measures should be taken with consideration of the type of surface composing the contaminated environment in order to minimize not only radiation-induced health detriment but also economic and social impacts.

A Study for Comparison of Geometric Characteristics on Forearms for Improvement of Convinience in Splint Manufacturing with 3D Printing Technology (3D 프린팅 기술을 적용한 스플린트의 제작 용이성 향상을 위한 아래팔 기하 정보 비교에 관한 연구)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.5
    • /
    • pp.475-481
    • /
    • 2019
  • A splint is one of assisting devices for the disabled with hemiplegia or contracture and is manually made by an experienced expert. Heated thermoplastic materials are continuously fitted to the affected part. This traditional method has a possible risk of low-temperature burn, quality variance of the splint due to the proficiency of maker. etc. While various approaches has been made using 3D printing technology in order to redeem those disadvantages, they still carry high cost issues with 3D scanners or accuracy issues with manual measurement. This research begins with symmetrical characteristics of human body and focuses on the preliminary study for the possibility of splint manufacturing with 3D printing technology based on geometric characteristics of unaffected arm. 3D right and left forearm models of healthy male adults were created by photogrammetry software and a series of digital images in order to measure the circumference and cross-sectional area of the forearm models at every 20mm from the elbow. The circumference and cross-sectional area showed tolerable levels of differences between both sides within subjects; The circumference and cross-sectional area showed very strong correlations between both sides within subjects. From these findings, the possibility of splint manufacturing with 3D printing technology could be confirmed based on the geometric characteristics of unaffected side.

Real-Time Joint Animation Production and Expression System using Deep Learning Model and Kinect Camera (딥러닝 모델과 Kinect 카메라를 이용한 실시간 관절 애니메이션 제작 및 표출 시스템 구축에 관한 연구)

  • Kim, Sang-Joon;Lee, Yu-Jin;Park, Goo-man
    • Journal of Broadcast Engineering
    • /
    • v.26 no.3
    • /
    • pp.269-282
    • /
    • 2021
  • As the distribution of 3D content such as augmented reality and virtual reality increases, the importance of real-time computer animation technology is increasing. However, the computer animation process consists mostly of manual or marker-attaching motion capture, which requires a very long time for experienced professionals to obtain realistic images. To solve these problems, animation production systems and algorithms based on deep learning model and sensors have recently emerged. Thus, in this paper, we study four methods of implementing natural human movement in deep learning model and kinect camera-based animation production systems. Each method is chosen considering its environmental characteristics and accuracy. The first method uses a Kinect camera. The second method uses a Kinect camera and a calibration algorithm. The third method uses deep learning model. The fourth method uses deep learning model and kinect. Experiments with the proposed method showed that the fourth method of deep learning model and using the Kinect simultaneously showed the best results compared to other methods.

A Study on a Quantified Structure Simulation Technique for Product Design Based on Augmented Reality (제품 디자인을 위한 증강현실 기반 정량구조 시뮬레이션 기법에 대한 연구)

  • Lee, Woo-Hun
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.85-94
    • /
    • 2005
  • Most of product designers use 3D CAD system as a inevitable design tool nowadays and many new products are developed through a concurrent engineering process. However, it is very difficult for novice designers to get the sense of reality from modeling objects shown in the computer screens. Such a intangibility problem comes from the lack of haptic interactions and contextual information about the real space because designers tend to do 3D modeling works only in a virtual space of 3D CAD system. To address this problem, this research investigate the possibility of a interactive quantified structure simulation for product design using AR(augmented reality) which can register a 3D CAD modeling object on the real space. We built a quantified structure simulation system based on AR and conducted a series of experiments to measure how accurately human perceive and adjust the size of virtual objects under varied experimental conditions in the AR environment. The experiment participants adjusted a virtual cube to a reference real cube within 1.3% relative error(5.3% relative StDev). The results gave the strong evidence that the participants can perceive the size of a virtual object very accurately. Furthermore, we found that it is easier to perceive the size of a virtual object in the condition of presenting plenty of real reference objects than few reference objects, and using LCD panel than HMD. We tried to apply the simulation system to identify preference characteristics for the appearance design of a home-service robot as a case study which explores the potential application of the system. There were significant variances in participants' preferred characteristics about robot appearance and that was supposed to come from the lack of typicality of robot image. Then, several characteristic groups were segmented by duster analysis. On the other hand, it was interesting finding that participants have significantly different preference characteristics between robot with arm and armless robot and there was a very strong correlation between the height of robot and arm length as a human body.

  • PDF

Evaluation of superficial dose for Postmastectomy using several treatment techniques (유방전절제술을 시행한 환자에서 치료기법에 따른 피부선량 평가)

  • Song, Yong Min;Choi, Ji Min;Kim, Jin Man;Kwon, Dong Yeol;Kim, Jong Sik;Cho, Hyun Sang;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.225-232
    • /
    • 2014
  • Purpose : The purpose of this study was to evaluate the surface and superficial dose for patients requiring postmastectomy radiation therapy(PMRT) with different treatment techniques. Materials and Methods : Computed tomography images were acquired for the phantom(I'mRT, IBA) consisting of tissue equivalent material. Hypothetical chestwall and lung were outlined and modified. Five treatment techniques(Wedged Tangential; WT, 4-field IMRT, 7-field IMRT, TOMO DIRECT, TOMO HELICAL) were evaluated using only 6MV photon beam. GafChromic EBT3 film was used for dose measurements at the surface and superficial dose. Surface dose profiles around the phantom were obtained for each treatment technique. For superficial dose measurements, film were used inside the phantom and analyzed superficial region for depth from 1-6mm. Results : TOMO DIRECT showed the highest surface dose by 47~70% of prescribed dose, while 7-field IMRT showed the lowest by 35~46% of prescribed dose. For the WT, 4-field IMRT and 7-field IMRT, superficial dose were measured over 60%, 70%, and 80% for 1mm, 2mm, and 5mm depth, respectively. In case of TOMO DIRECT and TOMO HELICAL, over 75%, 80%, and 90% of prescribed dose was measured, respectively. Surface and superficial dose range were uniform in overall chestwall for the 7-field IMRT and TOMO HELICAL. In contrast, Because of the dose enhancement effect with oblique incidence, The dose was gradually increased toward the obliquely tangential angle for the WT and TOMO DIRECT. Conclusion : For PMRT, TOMO DIRECT and TOMO HELICAL deliver the higher surface and superficial doses than treatment techniques based linear accelerator. It showed adequate dose(over 75% of prescribed dose) at 1mm depth in skin region.

A Study on Developing a Model for Cancer Damage Cost Due to Risk from Benzene in Ulsan Metropolitan City (울산 지역에서 대기중 벤젠으로 인한 암 사망 손실비용 추정 모형에 관한 연구)

  • Lee, Yong-Jin;Kim, Ye-Shin;Shin, Dong-Chun;Shin, Young-Chul
    • Environmental and Resource Economics Review
    • /
    • v.13 no.1
    • /
    • pp.49-82
    • /
    • 2004
  • The study aimed to evaluate cancer damage cost due to risk from benzene inhalation. We performed health risk assessment based on US EPA guideline to estimate annual population risk in Ulsan metropolitan city. Also, we estimated a willingness-to-pay amount for reducing a cancer mortality rate to evaluate a value of statistical life. We combined the annual population risk and the value of statistical life to calculate the cancer damage cost. In the health risk assessment, we applied the benzene unit risk ($2.2{\times}10^{-6}{\sim}7.8{\times}10^{-6}$) in the US EPA'S Integrated Risk Information System to assess the annual population risk. Average concentration of benzene in ambient air is $7.88{\mu}g/m^3$(min: 1.16~max: $23.32{\mu}g/m^3$). We targeted an exposure population of 516,641 persons who aged over 30 years old. Using a Monte-Carlo simulation for uncertainty analysis, we evaluated that the population risk of benzene during ten years in Ulsan city is 2.90 persons (5 percentile: 0.32~95 percentile: 9.11persons). And the monthly average WTP for 5/1,000 cancer mortality reduction during ten years is 14,852 Won(95% C.I: 13,135~16,794 Won) and the implied VSL is 36 million Won(95% C.I: 30~40 million Won). Cancer damage cost due to risk from benzene inhalation during 10 years in Ulsan city is about 104 million Won(5 percentile: 13~95 percentile: 328 million Won). Health benefit cost to reduce a cancer mortality risk of benzene is about 50 million Won is Ulsan metropolitann city. But, it is very important that this cost is not for all health damage cost of cancer mortality in some area. We just recommended a model for evaluating a cancer risk reduction, so we must re-evaluate an integrated application of total VOCs damage cost including benzene.

  • PDF

Evaluation of Countermeasures Effectiveness in a Radioactively Contaminated Urban Area Using METRO-K : The Implementation of Scenarios Designed by the EMRAS II Urban Areas Working Group (METRO-K를 사용한 방사능으로 오염된 도시지역에서 대응행위효과 평가 : EMRAS II 도시오염평가분과 시나리오의 이행)

  • Hwang, Won-Tae;Jeong, Hae-Sun;Jeong, Hyo-Joon;Kim, Eun-Han;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.108-115
    • /
    • 2012
  • The Urban Areas Working Group within the EMRAS-2 ($\underline{E}$nvironmental $\underline{M}$odelling for $\underline{RA}$diation $\underline{S}$afety, Phase 2), which has been supported by the IAEA (International Atomic Energy Agency), has designed some types of accidental scenarios to test and improve the capabilities of models used for evaluation of radioactive contamination in urban areas. For the comparison of the results predicted from the different models, the absorbed doses in air were analyzed as a function of time following the accident with consideration of countermeasures to be taken. Two kinds of considerations were performed to find the dependency of the predicted results. One is the 'accidental season', i.e. summer and winter, in which an event of radioactive contamination takes place in a specified urban area. Likewise, the 'rainfall intensity' on the day of an event was also considered with the option of 1) no rain, 2) light rain, and 3) heavy rain. The results predicted using a domestic model of METRO-K have been submitted to the Urban Areas Working Group for the intercomparison with those of other models. In this study, as a part of these results using METRO-K, the countermeasures effectiveness in terms of dose reduction was analyzed and presented for the ground floor of a 24-story business building in a specified urban area. As a result, it was found that the countermeasures effectiveness is distinctly dependent on the rainfall intensity on the day of an event, and season when an event takes place. It is related to the different deposition amount of the radionuclides to the surfaces and different behavior on the surfaces following a deposition, and different effectiveness from countermeasures. In conclusion, a selection of appropriate countermeasures with consideration of various environmental conditions may be important to minimize and optimize the socio-economic costs as well as radiation-induced health detriments.

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF