• Title/Summary/Keyword: 가동

Search Result 2,845, Processing Time 0.031 seconds

Conceptual Design of In-Service Inspection and Maintenance of tiquid Metal Reactor KALIMER (액체금속로 KALIMER의 가동중검사 및 보수 개념설계)

  • Joo, Young-Sang;Kim, Seok-Hoon;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.171-179
    • /
    • 2004
  • The design concepts of in-service inspection and maintenance are very important for the reactor system design of the nuclear power plant. The strategy of in-service inspection and maintenance should be reflected in the mechanical system design for the verification of the operability of liquid metal reactor KALIMER. In this paper the fundamental approaches of the in-service inspection and maintenance of the KALIMER are established to ensure the safety and reliability of the reactor system. The general method and requirement of the in-service inspection and maintenance for the reactor system and components are proposed and described to satisfy the intents of the ASME Section XI Division 3 and the design characteristics of KALIMER.

미국 원전에서의 보수작업 개선

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • v.6 no.12 s.46
    • /
    • pp.41-47
    • /
    • 1986
  • 미국 Carolina Power & Light사 (CP&L)의 Brunswick원전 1호기의 금년 1월에서 6월까지의 이용율과 가동율은 각각 $89\%,\;93.1\%$였는데 이 유니트는 1978$\~$1984년 사이에는 평균이용율이 $49.7\%$였었다. 2호기의 이용율과 가동율은 1985년에 각각 $72.5\%$$79.3\%$였으며 1978$\~$1984년 사이의 평균이용율은 $42.9\%$였었다. 제작회사인 GE의 통계에 의하면 금년 1월부터 8월까지 1호기의 가동율은 $94.2\%$로서 미국내의 30기의 GE 유니트중에서 3위를 차지했으며 전세계의 47기 GE 유니트중에서는 9위였으며 1985년에 2호기의 이용율과 가동율은 각각 8위와 17위를 기록했다.

  • PDF

울진 3,4호기 ESW 펌프 On-Line Maintenance분석

  • 김길유;한상훈;장승철;김태운
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.606-610
    • /
    • 1997
  • 울진 원전 3,4 호기 확률론적 안전성 평가 (PSA) 모델을 risk monitor 모델로 변환하여 한국원자력연구소에서 개발한 risk monitor인 Risk Monster[1]에 설치하였으며 이를 이용하여 필수냉각수 계통(ESW;Essential Service Water) 펌프의 가동중 정비(on-line maintenance)의 가능성 여부를 연구하였다. ESW 펌프를 가동중 정비하더라도 안전성 측면에서 별 문제가 없으며 경제성 여부는 보다 정확한 검토가 요구되나 상당히 있는 것으로 판단된다. 한편 ESW펌프 한대의 고장이 원전 가동중에 미치는 위험도를 분석하였으며 그 결과 ESW펌프 한대의 고장에도 불구하고 원전 계속 가동에는 큰 문제가 없었다.

  • PDF

정책안내 - "인증서 대여한 불법전자입찰 뿌리 뽑는다" - 조달청, 불법전자입찰 징후분석시스템 본격가동 -

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.229
    • /
    • pp.41-42
    • /
    • 2009
  • 조달청이 입찰자 정보를 분석해 불법전자입찰을 색출해내는 '불법전자입찰 징후분석시스템'을 본격 가동한다. 조달청(청장 권태균)은 지난 7월 22일 "아직도 일부 입찰자들이 전자입찰시스템을 악용, 담함 및 공인 인증서 대여 등의 불법입찰 행위를 하고 있다"고 지적하고 "이를 체계적이고 상시 감시하기 위한 불법전자 입찰 징후분석시스템(이하 '징후분석시스템')을 본격 가동해 불법입찰 혐의가 짙은 201개 업체를 공정거래 위원회에 조사요청 할 계획"이라고 밝혔다. 이번 '징후분석시스템'의 본격가동으로 인증서 대여를 통한 불법전자입찰 행위를 뿌리 뽑아, 국가예산의 낭비방지 및 공공공사와 조달물품의 품질 제고에 기여할 것으로 기대된다.

  • PDF

비파괴 검사기술을 이용한 원자력 발전설비 예방진단

  • 박상기;권오철
    • 전기의세계
    • /
    • v.38 no.11
    • /
    • pp.55-62
    • /
    • 1989
  • 원자력 발전소의 건설 및 운전은 설계, 제작, 건설 및 운전등에 이르기까지 안전에 대한 고려가 치밀하게 이루어지고 있으며 그중에서도 원자력 부품의 제작, 설치시는 물론이고 원전의 건설후 사용전 및 사용중에 수시 또는 정기적으로 거의 모든 중요한 부품들에 대한 비파괴 검사는 필수적이며 제반 법규 및 규격도 원자력발전 설비에 대한 요건을 엄격하게 규정하고 있다. 국내에 운전중인 모든 원전에 대해서도 제반 법규 및 규격요건에 따른 제작/설치 검사와 가동전 및 가동중 검사를 첨단기술을 이용하여 엄격리 실시하여 발견될 주요결함은 수리조차하고 있으며 미세한 결함까지도 기록관리하며 가동중 검사에서 이들의 성장 뿐 아니라 새로운 결함의 생성들을 찾아냄으로써 원전의 안전성 확보와 가동율 향상이라는 소기의 목적을 위해 원전의 예방진단에 만전을 기하고 있다.

  • PDF

Effects of Operating Temperatures on Decomposition and Physicho-chemical Properties of Food Wastes in a Fermentation Dryer (발효건조장치의 가동온도가 음식물쓰레기의 분해 및 이·화학성에 미치는 영향)

  • Seo, Jeoung-Yoon;Park, Ju-Won;Lee, Young-Hyeung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.1
    • /
    • pp.97-102
    • /
    • 2000
  • This study was carried out to investigate the effects of operating temperatures on decomposition and physicho-chemical properties of household food wastes in a fermentation dryer, which was manufactured by Samwoo Co. Ltd. The household food wastes of 100 kg can be put and dried in this dryer at once. The experiments were performed at each temperature of $35^{\circ}C$, $45^{\circ}C$, $55^{\circ}C$ and $70^{\circ}C$ for two days respectively. The samples taken at the fixed time were dried at $105^{\circ}C$ and analyzed to find the decomposition rate and the concentration of each substance. The results obtained were as follows: The decomposition rate at 35 and $70^{\circ}C$ was the highest and showed the similar tendency during the experimental period. The higher the operating temperature was, the faster the water content of the composting material reduced. pH value increased at the operating temperature of 55 and $70^{\circ}C$ and was higher than at the other operating temperatures. Nitrogen content did not show any tendency during the experimental period. $P_2O_5$ and CaO content increased during the experimental period but MgO, $K_2O$ and NaCl were not accumulated. Cu content based on dry matter was in the range of ND~100.4 mg/kg and Cd, Pb and Cr were not detected.

  • PDF

The Flood Elevation Reduction Effect by Sluice Operation at Multistage Movable Weir System (다단식 하단방류형 가동보 수문시스템에서 수문개도 조작에 의한 홍수위 저감효과)

  • Lee, Ji Haeng;Han, Il Yeong;Ra, Sung Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.367-367
    • /
    • 2016
  • 우리나라는 하상계수가 큰 하천의 특성 때문에 콘크리트 구조의 고정보를 설치하여 하천수위를 유지하고, 취수용으로 사용하여 왔다. 그러나 고정보는 유수방해, 토사퇴적으로 인한 홍수위 상승 등의 다양한 문제를 야기시키고 있다. 이에 따라 4대강에는 다양한 형상과 운영방식이 적용된 가동보가 설치되었으며, 소하천과 중규모 하천 역시 하천기능의 복원을 위한 정비사업이 진행되고 있다. 하천관리의 목표는 하천의 이수, 치수 및 생태환경 기능의 종합적이며, 유기적인 관계를 조화롭게 유지하면서 각 기능을 극대화시키는 것이다. 우선, 토사의 퇴적을 사전에 예방하고, 퇴적된 토사는 유수에 따라 배출될 수 있도록 하단방류 형식으로 개선되어야 한다. 또한 홍수기에는 통수가 원활하도록 보의 기능을 해제할 수 있어야 하는 한편, 하류구간이 범람하지 않도록 상류구간에서의 완충기능을 가져야 한다. 이러한 요구조건을 충족하기 위해서 다단형태의 하단방류형 가동보 수문 시스템을 고려할 수 있다. 다단형태의 하단방류형 가동보 수문시스템은 경사 하천에 가동보에 의해 물을 저수하고, 저수된 물을 보 상류에서 유입되는 유입수량 만큼만을 수문 하단 개도부를 통하여 방류하도록 하여, 일정량이 항상 저류되면서 퇴적토사가 배출되도록 하여 수질을 개선하는 방식이다. 본 연구에서는 금강의 지류인 치성천 9Km 구간을 대상으로 HEC-RAS 4.1 모형을 적용하여 하단방류형 가동보를 하류부터 상류구간까지 다단형태로 설치하였을 경우, 하천의 저류와 분배기능 회복에 따른 홍수위 저감 효과를 고정보 설치의 경우와 비교 분석하였다. 홍수소통 능력을 검토하기 위해서 연구대상 구간을 200년 빈도의 확률홍수량 별로 10개 구간으로 나누어 검토한 결과, 고정보 설치의 경우에는 여유고 기준을 초과하는 부분이 나타났으나, 다단식 하단방류형 가동보를 설치하고, 수문개도를 조작하여 운영할 경우에는 여유고 기준을 초과하는 부분이 없어, 홍수위 저감 효과를 기대할 수 있는 것으로 나타났을 뿐만 아니라, 홍수기이후에도 하천유지용수 기준을 만족하는 것으로 나타났다. 또한 설치 및 유지관리의 비용측면과 용수확보 및 홍수피해 절감의 편익측면에서도 50년 운영주기의 비용편익성은 양호한 것으로 나타났으며, 생태환경보전과 친수공간 확보측면의 편익성을 추가로 고려할 경우, 경제성은 충분히 확보될 것으로 판단되었다.

  • PDF

자동차 에어컨 및 난방장치 가동에 따른 bioaerosol 노출특성

  • 이지현;조완근;서영준;강정환;이준엽;권기동
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2004.11a
    • /
    • pp.36-38
    • /
    • 2004
  • 겨울철 및 여름철의 자동차 실내에서의 환기장치 (heater and air conditioner)의 작동이 차내 바이오 에어로졸농도에 미치는 영향을 조사한바 가동전보다 히터나 에어컨 가동 후 미생물 농도가 감소하여 실내 환기장치는 어느정도 공기정화 기능을 하고 있는 것으로 판단된다.

  • PDF