• Title/Summary/Keyword: 가돌리늄 조영제

Search Result 22, Processing Time 0.018 seconds

Contrast Enhanced Cerebral MR Venography: Comparison between Arterial and Venous Triggering Methods (조영 증강 자기공명정맥 촬영술에서의 동맥과 정맥 triggering 방법의 비교)

  • Jang, Min-Ji;Choi, Hyun-Seok;Jung, So-Lyung;Ahn, Kook-Jin;Kim, Bum-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2012
  • Purpose : To compare the arterial and venous detection sites of triggering methods in contrast-enhanced-MR-venography (CE-MRV) for the evaluation of intracranial venous system. Materials and Methods: 41 healthy patients underwent CE-MRV with autotriggering at either the cavernous segment of internal carotid artery with an inserted time-delay of 6 seconds (n = 20) or the superior sagittal sinus without any timedelay (n = 21). 0.1 mmol/kg gadolinium-based contrast material ($Magnevist^{(R)}$, Schering, Germany) was intravenously injected by hand injection. A sagittal fast-spoiled-gradient-echo-sequence ranging from one ear to the other was performed (TR/TE5.2/1.5, Matrix $310{\times}310$, 124 sections in the 15-cm-thick volume). 17 predefined venous structures were evaluated on all venograms by two neuroradiologists and defined as completely visible, partially visible, or none visible. Results: The rate of completely visible structures were 272 out of 323 (84%) in the arterial triggering CE-MRV and 310 out of 340 (91%) in the venous triggering CE-MRV. The venous triggering CE-MRV demonstrated an overall superior visualization of the cerebral veins than the arterial triggering CE-MRV (Fisher exact test, p < 0.006). Conclusion: CE-MRV using venous autotriggering method provides higher-quality images of the intracranial venous structures compared to that of arterial.

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.