• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.024 seconds

The analysis of leakage current characteristics of polymer insulators for estimation under Pollution conditions (고분자 절연물의 내오손 진단을 위한 누설전류 특성 해석)

  • Kim, I.S.;Han, S.W.;Cho, H.G.;Soh, J.J.;Kim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1452-1454
    • /
    • 1997
  • Properties of flashover in polymer insulators are very important under pollution environments. It is necessary to analyse flashover characteristics whether insulators are still safe or not. A lot of precious information can be got out of polluted polymer insulators through leakage current measurement. The behavior of partial arc discharge leads to flashover directly. It is possible to measure partial arc discharge as leakage current pulses analysis. The shape of histogram reflects degree of pollution, wetting and voltage stress level. It can be expressed by Weibull distribution function.

  • PDF

Zinc Oxide Varistors with Praseodymium Oxide (Praseodymium계 ZnO 바리스터의 제조 및 미세구조 연구)

  • Soh, J.J.;Han, S.W.;Kim, H.S.;Cho, H.G.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1342-1344
    • /
    • 1997
  • Zinc oxide varistors which contain rare earth metal oxides have been developed. These Varistors are widely used for low voltage surge-protection devices and high voltage arresters for electric power stations. The characteristics of varistors with praseodymium oxide as a principal additive are discussed. A two-phase microstructure with an intergranular phase between the ZnO grains.

  • PDF

The simulation of electrical characteristic and the microstructure of ZnO varistor with Voronoi network (보로노이 네트워크를 이용한 ZnO 바리스터의 미세구조와 전기적 전도특성의 시뮬레이션 연구)

  • Hwang, Hui-Dong;Han, Se-Won;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1405-1407
    • /
    • 1997
  • A microstructure of realistic ZnO varistor is constructed by Voronoi network and studied via computer simulation. In this network, the grain boundary condition is fitted from the experimental data. The effect of the variation of the uniformity of the varistor on the electrical characteristic of the varistor is simulated by using this boundary condition.

  • PDF

The Evaluation of Tracking and Erosion Resistance of Silicone Rubber for Outdoor Use by the Inclined-Plane Method (경사평면법에 의한 옥외용 실리콘고우의 내트래킹성 및 내침식성 평가)

  • Kim, J.H.;Song, W.C.;Park, Y.G.;Kim, H.G.;Kim, I.S.;Han, S.W.;Cho, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1500-1502
    • /
    • 1997
  • We investigated the tracking and erosion resistance of the silicone rubber by Inclined-Plane Method. And, with the variation of the accelerated conditions such as the applied voltage and composition of contaminant, the change of the tracking characteristics according to such conditions was evaluated. The leakage current significantly increases with the increasing voltage, but the weight loss remains almost the same. The voltage above 5.0 kV isn't recommended because tracking breakdown occurs as fast as it does without erosion, and the typical discharge waveform was the form of rectifying wave.

  • PDF

Fuel Spray Characteristics in the High Pressure Injection Process (고압분사 시 연료분무 특성에 관한 연구)

  • Ahn, J.H.;Kim, H.M.;Shin, M.C.;Kim, S.W.
    • Journal of ILASS-Korea
    • /
    • v.8 no.4
    • /
    • pp.31-38
    • /
    • 2003
  • Constant volume combustion chamber has been designed to investigate diesel spray characteristics with Common-Rail injection system to realize high pressure injection. In this study, two methods of measurements, Schlieren shadowgraphy and Mie scattering imaging method ate applied experimentally to study spray form and liquid phase zone in high pressure, high temperature conditions. Diesel fuel is injected at the point which ignited mixture gas is completely burned. The effect of injection pressure, injector hole diameter, ambient gas temperature and density are investigated experimentally.

  • PDF

The Packaging Technology Thermoelectric Generator (열전모듈을 이용한 발전기의 패키징)

  • 한경목;황창원;백동규;최승철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.1-6
    • /
    • 2000
  • A simple and compact type of thermoelectric generator was developed as the energy saving system using waste hot water and low temperature waste heat sources. Sixteen of Bi-Te thermoelectric modules were packaged in series for thermoelectric conversion system using hot water as heat source. The thermoelectric generator shows the power output of about 4.5 W with the temperature difference of about 75 K at 40 $\Omega$ and 0.35 A for the electrical resistance and current of the used thermoelectric module, respectively.

  • PDF

금속선을 삽입한 고체 추진제의 연소 특성

  • 유지창;박영규;김인철;임유진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.131-137
    • /
    • 1996
  • HTPB/AP/Al이 주성분인 2종의 혼합형 추진제를 대상으로 4종의 금속선(Ag, Cu, Al, Ni-Cr)윰 각각 삽입하여 금속선의 직경(0.1~0.8mm)과 연소 압력에 따른 금속선에 인접한 고체 추진제의 연소 속도 증가비($r_w$/$r_sb$)와 압력 지수(n)의 변화를 고찰하였다. 금속선을 추진제에 삽입함으로써 추진제의 $r_w$/$r_sb$ 는 크게 중가하였고, 1000 psia의 압력에서의 최대 6.59배 증가하였다. 그러나 녹는 점이 비교적 낮은 Al 선이나 Ag선은 금속선 직경이 작아짐에 따라 한계 직경에서 $r_w$가 급격히 감소하는 최대값이 존재하였다. 자연 발화 온도와 금속선으로 전달되는 열원인 연소 기체 불꽃 온도로 구성된 무차원군을 Buckingham pi 정리에 의해 구해진 $r_w$/$r_sb$ 에 대한 기존의 무차원 실험식에 추가로 적용하여 계산해 본 결과, 자연 발화 온도는 고려하지 않고 금속선의 녹는 점과 연소 기체의 불꽃 온도를 무시한 Hsing 의 실험식에 의해 계산된 결과보다 표준 편차가 45%이상 줄어듬을 알 수 있었다.

  • PDF

A Study on the Conjugate Heat Transfer from Horizontal Plate with Protruding Heat Source (열원이 부착된 수평 평판에서 복합 열전달에 관한 연구)

  • 김병철;주동인
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.512-518
    • /
    • 2002
  • The real chip and similarity model were used to investigate the thermal behavior and velocity distribution of air from the heat source with the location and the amount of heat experimentally and numerically, and compared. The heat generated in the block is not cooled by convection and show the high temperature by the stagnation of heat flow. After maintaining the high temperature of block by the natural convection, the sudden drop of temperature with the air flow was shown in the channel but the decreasing rate was small with the time. The inward block was effected by infinitesimal air flow generated between block and channel and outward block was effected by the entry condition.

Validating the Applicability of a Simplified Correlation Method for Economic Evaluation of Cooling Plants (냉방열원기기의 경제성 평가를 위한 간이계산법의 적용성 검토)

  • 김영섭;김강수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.854-862
    • /
    • 2002
  • In the previous research, a simplified correlation method was developed as an easy prediction tool for comparing energy use of cooling plants. The purpose of this paper is to test the applicability of this method for economic evaluation with two zones of a 20-story commercial building in Seoul. The results of this method were compared with the DOE-2 simulation and actual measured data. Then, Comparisons of life cycle cost were carried out for three types of cooling plants. Testing of one zone showed good agreement of within 10% error in cooling energy use and within 2% error in LCC. But testing of the other zone indicated that the use of this method were invalid when input variables were used beyond its valid range.

Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System (복합 열원 공조시스템의 최적 제어 알고리즘)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.