• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.032 seconds

A Study of the Effect of Grouting Region on the Solution of Line Source Analysis (그라우팅 영역이 선형열원 해석에 미치는 영향에 관한 연구)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.143-150
    • /
    • 2010
  • Line source method of borehole system assumes the entire surrounding medium is uniform. However, thermal properties of grouting region are considerably different from those of surrounding soil. In this study we investigate the effect of grouting materials on the solution of line source method with the aid of numerical analysis. This numerical model generates the temperature of borehole fluid with which line source solution can be obtained. Then this solution can be compared with input condition of numerical model. The results of this comparison show that thermal conductivity and borehole thermal resistance of line source solution are approximately 86% and 91% of the input condition of numerical model. Chart method is developed in this study to find the numerical input conditions (thermal conductivity and borehole thermal resistance) from the line source solution. Thermal response test of test borehole is conducted, the results of which are approximately consistent with the Chart method. Thermal property changes of grouting materials on the line source solution are also examined.

Study for High Efficiency Heat Pump System Commercialization with Air Heat Source (고효율 공기열원 히트펌프시스템 실용화 연구)

  • Han, Jang-Min;Kim, Young-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.405-408
    • /
    • 2009
  • 공기열원 히트펌프시스템의 문제점, 즉 열효율, 안정성, 착상에 대한 현황을 파악하고 이를 해결하기 위한 연구를 수행하였다. 열효율과 안정성을 위해 기존 시스템을 보완한 8행정 냉매사이클시스템 개발과 제어시스템의 개발을 통해 히트펌프 시스템의 효율을 2배 정도 증가시키고, 안정성을 높이며, 착상 문제를 최소화할 수 있도록 하였다. 개발된 공기열원 히트펌프시스템의 COP는 평균 5정도이고, 안정적으로 운용되는 외부 온도는 $-10^{\circ}C$에서 $55^{\circ}C$까지이다. 토출되는 온수의 온도는 $50{\sim}60^{\circ}C$정도이다. 평균 제상시간은 1분 이내이다. 앞으로 개발해야 할 문제는 외부 온도 $-10^{\circ}C$ 이하지역에서 보조열원 없이 난방을 할 수 있고 친환경 냉매를 사용하며 COP가 7이상인 고효율 히트펌프시스템를 실용화하는 것이다.

  • PDF

Study on the Performance of Fuel Cell Driven Compound Source Heat Pump System to a Large Community Building (대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구)

  • Jeong, Dong-Hwa;Byun, Jae-Ki;Choi, Young-Don;Cho, Sung-Hwan
    • New & Renewable Energy
    • /
    • v.4 no.3
    • /
    • pp.23-35
    • /
    • 2008
  • In the present study, performances of fuel cell driven compound source hybrid heat pump system applied to a large community building are simulated. Among several renewable energy sources, ground, river, sea, and waste water sources are chosen as available alternative energies. The performance and energy cost are varied with the hybrid heat pump sources. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. Th system is driven by fuel cell system instead of the late-night electricity due to the advantages of the low energy cost and waste heat with high temperature.

  • PDF

Thermodynamic Performance Characteristics of Transcritical Organic Rankine Cycle Depending on Source Temperature and Working Fluid (열원온도와 작동유체에 따른 초월임계 유기랭킨사이클의 열역학적 성능 특성)

  • Kim, Kyoung Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.699-707
    • /
    • 2017
  • This study presents a comparative thermodynamic analysis of subcritical and transcritical organic Rankine cycles for the recovery of low-temperature heat sources considering nine substances as the working fluids. The effects of the turbine inlet pressure, source temperature, and working fluid on system performance were all investigated with respect to metrics such as the temperature distribution of the fluids and pinch point in the heat exchanger, mass flow rate, and net power production, as well as the thermal efficiency. Results show that as the turbine inlet pressure increases from the subcritical to the supercritical range, the mismatch between hot and cold streams in the heat exchanger decreases, and the net power production and thermal efficiency increase; however, the turbine size per unit power production decreases.

Thermodynamic Optimization of a Organic Rankine Power Cycle (유기 랭킨 사이클 시스템의 열역학적 최적화)

  • Lee, W.Y.;Won, S.H.;Chung, H.S.
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.35-45
    • /
    • 1990
  • An analytical equation to estimate the Rankine power cycle efficiency at maximum power for the given mass flow rates of heating and cooling fluids is derived. The accuracy of the result is shown by comparing the analytical values with those calculated one using detailed thermodynamic data. The results indicate that the thermal efficiency at maximum power depends primarily on the initial temperatures of the heating and cooling fluids, and it also depends on the pinch-temperature differences between the working fluid and the heating and cooling fluids. The efficiency at maximum power provides a measure of the power available in a practical Rankine heat engine.

  • PDF

Improvement of Drying Performance of Natural Convection Drier Part I : Analysis of Natural Convection Drier (자연대류형 건조기의성능향상을 위한 모형실험 I. 자연대류형 건조기의 분석)

  • 류관희;정도섭;정창주
    • Journal of Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.25-31
    • /
    • 1979
  • 본연구는 건조에 필요한 열과 공기를 열원으로부터의 자연대류만에 의존하는 간역화력건조기의 성능향상을 도모하기 위하여 실시되었으며 옥수수를 대상으로 모형실험을 통하여 분석한 결과는 다음과 같이 요약된다. 1. 건조기 화구의 공기열입구의 크기는 송풍량에 영향을 미치며 공기의 유입속도가 16m/min 이하가 되도록 충분히 만들어야 한다. 2. 곡물층을 통과하는 송풍량은 곡물층의 두께가 클수록 증가하며 송풍량과 곡물층 두께와의 관계는다음식으로 나타났다. $q=CD^{-k}$ 3. 송풍량은 실험범위내에서는 열원으로부터 곡물층의 높이와 가열공기의 온도상승에 따라 각각 직선적으로 증가하였다. 4. 송풍량은 곡물층의 두께, 열원으로부터의 곡물의 높이 및 가열공기의 온도상승에 의하여 옥수수층의 경우 다음과 같이 추정될 수 있다. $ q=0.00265H(\Delta T) D^{-0.76}$ 5. 바람이 송풍량에 미치는 영향은 매우 커서 8km/hr의 풍속을 가진 바람이 유입구측으로부터 볼 때 송풍량은 바람이 없을 때보다 무려 5배나 증가하였다. 6. 건조실의 전후방간의 가열공기의 온도차이는 열원으로부터 곡물층의 높이가 낮을수록 증가하였으며 이 현상은 바람이 불 때 더욱 현저하게 나타났다. 7. 건조기의 벽면을 통한 열손실은 열원으로부터 곡물층의 높이와 가열공기의 온도상승에 따라 각각 직선적으로 증가하였다.

  • PDF

집단에너지사업 수도권 네트워크 경제성 분석

  • 박용순;송은영
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.1
    • /
    • pp.48-56
    • /
    • 2000
  • 한국지역난방공사는 '87년 여의도에 최초 연공급을 시작한 이래 수도권 신도시 및 서울 강남 지역을 중심으로 지역난방 열공급을 지속적으로 확대하여 왔다. 안정적이고 경제적인 역공급을 위하여 분당, 고양 및 중앙의 CHP를 중심으로 연계배관망을 구성하였으며 '98년 기준 수도권 연계 공급량이 총 공급량의 61%를 차지하게 되었다. 또한 장기적으로 본 공사는 열공급의 신뢰성 및 경제성 향상을 위하여 급열센타 설치를 비롯하여 종합적인 네트워크를 구성하여 운영할 계획이며 분당과 고양의 CHP를 기저부하로 삼아 피크수요를 감당할 소규모 분산형 열원을 설치하여 수도권 열공급을 확대하여 전 수도권을 지역난방 배관으로 네트워크화할 계획을 가지고 있다. 따라서, 구체적인 세부계획을 수립하기 위하여는 수도권 네트워크 사업의 장기적인 경제성 분석이 필수적이며 이러한 분석은 기존의 열원 및 열배관시설은 물론 향후 건설될 열원 및 배관, 수요개발전망 등 제반요소를 고려하여 종합적으로 이루어져야 하다. 본 연구는 이에 앞서 분당과 일산CHP를 독립된 수용범위를 갖는 열원으로 간주하여 각각의 CHP를 중심으로 열공급량의 증가에 따라 피크용 열원인 HOB 건설을 증가시킬때의 경제성을 그 대상으로 하여 기본적인 모델을 제시하고 대략적인 추세를 파악하고자 하였다. 데이터는 본 공사 고양지사와 분당지사의 '98 운영실적으로 기준으로 하였으며, 수도권 전체 네트워크를 대상으로 하는 실제 경제성 분석은 다음 과제로 계속 추진될 것이다.

  • PDF

A performance simulation of heat pump system for heating and cooling (냉난방 열펌프시스템의 성능시뮬레이션)

  • 강호철;김영복;김성태;민영봉
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1999.07a
    • /
    • pp.104-111
    • /
    • 1999
  • 증기압축식 열펌프시스템은 그림 1에 나타난 바와 같이 증발기에서의 흡열과 응축기의 방열을 냉난방에 이용할 수 있으며, 공기를 열원으로 할 때는 공기 중 저밀도의 에너지를 고밀도의 에너지로 전환하여 이용할 수 있으며 지중 온도의 연중변화가 적은 점을 이용하여 지열을 열원으로 할 때는 공기를 열원으로 할 경우에 필요한 제상 장치(defrost cycle)가 필요 없게 되고, 압축기 부하도 줄어들게 되어 열펌프 수명이 길어지게 되며 경제성을 확보할 수 있을 것으로 기대된다. (중략)

  • PDF

생활폐열회수를 위한 열교환기 개발 중심 폐열회수 고효율 난방 시스템

  • 신현준;이태원
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.65-73
    • /
    • 1994
  • 도시생활폐수에 포함되어 배출되는 폐열을 열펌프의 열원으로 하는 폐수열원 열펌프 시스템에 대한 관심이 오래전부터 집중되어 있었지만 폐수 열교환기 전열면의 오염문제 때문에 실용화에 커다란 진전을 보지 못하고 있다. 한편, 생활페수는 비교적 저온이기 때문에 열펌프시스템의 설계에 특별한 주의를 기울여야 한다. 즉, 이러한 폐열을 회수하여 유효에너지 자원화 하기 위한 신기술이 이루어 져야한다. 본 연구에서는 이러한 점을 감안하여 도시생활 폐수열의 이용가능성을 검토하고 이를 열원으로 하는 열펌프의 개발을 위한 폐수 열교환기의 모델을 개발하였다.

  • PDF