• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.029 seconds

A Study on the Smoke Movement by the Opening and Heat Generator Position (개구부와 열원의 위치에 따른 연기이동에 관한 연구)

  • 조성우;이재윤
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.7-14
    • /
    • 2002
  • The diffusion characteristics of the smoke by effect of an ascending air movement in a local part of the room where heat generated was studied. How the smoke move in the limited parts of the room at which heat generated was studied through 3 cases altering locations of inlet and outlet of ventilated air and heat generated by CFD(Computational Fluids Dynamics) method. It was found that 1. Similar distribution of air velocity, air temperature and smoke concentration appeared in the case of upper left inlet and lower right outlet and the case of lower inlet and upper right outlet. 2. Distribution of temperature and smoke concentration was 0∼0.3, 0.06∼0.14 in the case of lower left inlet and upper right outlet. 3. the location of heat generation did not influence on the temperature distribution, but influence on the distribution of smoke concentration.

A Study on Heat Source Model to Creep Feed Grinding (크?피드 연삭에서 열원 모델에 관한 연구)

  • Jeong, Jong-Dal;Jeong, Hae-Do;Choe, Heon-Jong;Kim, Nam-Gyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.171-176
    • /
    • 2001
  • This study focuses on the energy partition and heat flux distribution in creep-feed grinding. From the measurements of transient grinding temperature in the workpiece which the thermocouple was embedded, the overall energy partition to the workpiece was estimated with moving heat source theory using the developed scalene triangle heat model. The energy partition was calculated as 3.75% in down grinding smaller than 5.3% in up grinding. Also, the scalene triangle heat model was confirmed as the most optional heat model in correspond to the experimental data. Then, the heat flux distribution was calculated from temperature responses. The heat flux is negative behind the grinding zone where fluid was applied. In this experimental result, the total heat flow to the workpiece per unit width obtained by integrating the positive heat flux was 0,7W/mm for down grinding.

  • PDF

Performance analysis of dual source heat pump system with single unit dual source evaporator (SUDS증발기를 사용한 2중열원 열펌프의 성능해석)

  • 우정선;이세균;이재효;박효순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF

Electrical Properties of $BaTiO_3$ PTC Ceramics with Additional Elements (첨가원소에 따른 $BaTiO_3$ 계 PTC 세라믹스의 전기적 특성)

  • Kim, Hye-Jin;Hong, Youn-Jeong;Lee, Kyu-Mann
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.305-306
    • /
    • 2006
  • 자동차의 난방 열원은 HVAC(Heating, Ventilating & Air Conditioning)에 내장되어 있는 히터코어 (Heater Core) 에서 공급하게 되며, 이 히터코어는 엔진에서 가열된 냉각수 열원을 이용하게 된다. 그러나 최근 디젤 엔진의 경우 연소효율의 개선과 CEGR(Cooled Exhaust Gas Recirculation) 시스템의 적용으로 냉각부하가 증가하여 냉각수가 가지는 가용 열원이 기종보다 약 30~40% 정도 저하되고 있다. 따라서 디젤 자동차 및 하이브리드용 자동차의 난방 보조 히터의 국산화 개발이 시급해진 상황이며 초정밀, 고효율 보조 히터의 개발이 요구되고 있다. 현재 적용되고 있는 보조 히터 중에서 PTC 히터는 PTC 소자의 발열을 이용하여 공기를 직접 가열하기 때문에 추가적인 연료소비가 없고 소형 및 저가라는 장점이 있다. PTC 세라믹 소자는 $BaTiO_3$를 모체로 하며, 이의 특성 항상 및 제어를 위해서는 적절한 dopant를 선택하여 균일하게 doping 해야 한다. 지금까지 dopant에 따른 구성 요소 및 역할은 비교적 잘 알려져 있다. 하지만, 자동차용으로 사용되기 위해서는 12V의 저전압에서 동작해야 하며, 또한 소자의 두께가 얇아지게 됨에 따라서 발생하는 전기적 short와 같은 문제점들을 해결하여야 한다. 따라서 본 연구에서는 PTC 세라믹 소자에서 도펀트 종류와 양 조절을 통한 저저항을 확보하고, PTC 세라믹 소자의 박막화를 달성하고자 하였다.

  • PDF

A Study on Heat Transfer Analysis around the Square Heat Source of Interior Solid by Using Finite Element Method (유한요소법에 의한 고체내부의 사각열원 주위 열전도 특성연구)

  • Jang, Jae-Eun;Hong, Bong-Gi
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.18 no.2
    • /
    • pp.101-108
    • /
    • 1982
  • In this paper the result of heat transfer analysis around the square heat source of interior solid by using the F. E. M is reported. Calculation for temperature distribution and each element was used by F. E. M. the solid is sub-divided into system of equal size triangular shape. These values of temperature distribution will valuable for design of jet engine and steam generator and the results gained are as follow; 1. Calculation by F. E. M is identified with the experiment. 2. Temperature distribution on the horizontal surface is $\theta$=0.698 in model 4 and the other hand $\theta$=0.401 in model 6 for X=16cm. In intermediates surface between heat source and bottom surface, the influence of L is more greater than that of height in the temperature difference. 3. Temperature distribution on the vertical surface for model 2 is resulted strong influence by K. In the case of Y=4cm is identified with $\theta$=0.0790 for K=7 and also $\theta$=0.0036 for K=0.3. In the difference of temperature distribution.

  • PDF

Studies on Raw-Water Source Heat Pump Equipped with Thermal Storage Tank in Water Treatment Facility (정수장 내 축열조 설치 원수열원 히트펌프의 성능분석)

  • Oh, Sun Hee;Yun, Rin;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.467-472
    • /
    • 2013
  • A raw-water source heat pump equipped with a thermal storage tank was dynamically simulated by TRNSYS, and the results were verified by using the data from a heat pump installed in the Seongnam water treatment facility. The average coefficient of performance (COP) of the raw-water source heat pump based on simulation was 4.97 and 3.17 in the cooling and heating season, respectively. When the volume of the thermal storage tank was changed from 5 to $20m^3$, the highest COP was found at a size of $10m^3$. Considering the regional locations of raw-water source heat pumps at Seoul, Incheon, Gangneung, and Gwangju, Seoul showed the lowest electric power consumption in the cooling season and the highest in the heating season. When a comparison of the performance between the present system and that of a water-air heat pump was conducted, the present system showed lower electric power consumption by 25% than that of a water-air heat pump.

Heat Transfer in Bubble Columns with High Viscous and Low Surface Tension Media (고점성 낮은표면장력 매체 기포탑에서 열전달)

  • Kim, Wan Tae;Lim, Dae Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.516-521
    • /
    • 2014
  • Axial and overall heat transfer coefficients were investigated in a bubble column with relatively high viscous and low surface tension media. Effects of superficial gas velocity (0.02~0.1 m/s), liquid viscosity ($0.1{\sim}0.3Pa{\cdot}s$) and surface tension ($66.1{\sim}72.9{\times}10^{-3}N/m$) on the local and overall heat transfer coefficients were examined. The heat transfer field was composed of the immersed heater and the bubble column; a vertical heater was installed at the center of the column coaxially. The heat transfer coefficient was determined by measuring the temperature differences continuously between the heater surface and the column which was bubbling in a given operating condition, with the knowledge of heat supply to the heater. The local heat transfer coefficient increased with increasing superficial gas velocity but decreased with increasing axial distance from the gas distributor and liquid surface tension. The overall heat transfer coefficient increased with increasing superficial gas velocity but decreased with increasing liquid viscosity or surface tension. The overall heat transfer coefficient was well correlated in terms of operating variables such as superficial gas velocity, liquid surface tension and liquid viscosity with a correlation coefficient of 0.91, and in terms of dimensionless groups such as Nusselt, Reynolds, Prandtl and Weber numbers with a correlation of 0.92; $$h=2502U^{0.236}_{G}{\mu}^{-0.250}_{L}{\sigma}^{-0.028}_L$$ $$Nu=325Re^{0.180}Pr^{-0.067}We^{0.028}$$.

Effects of Liquid Surface Tension on the Heat Transfer Coefficient in a Three-Phase Slurry Bubble Column (삼상슬러리 기포탑에서 액상의 표면장력이 열전달 계수에 미치는 영향)

  • Lim, Ho;Lim, Dae Ho;Jin, Hae-Ryong;Kang, Yong;Jung, Heon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.499-504
    • /
    • 2012
  • Characteristics of overall heat transfer were investigated in a three-phase slurry bubble column with relatively low surface tension media, which has been frequently encountered in the fields of industry. The heat transfer phenomena was examined in the system which was composed of a coaxial vertical heater and a proper of bubble column. The heat transfer coefficient was estimated from the measured mean value of temperature difference between the heater surface and the column proper at the steady state condition. Effects of gas velocity ($U_G$), solid fraction in the slurry phase ($C_S$) and surface tension (${\sigma}_L$) of continuous liquid media on the overall heat transfer coefficient (h) in the bubble column were determined. The mean value of temperature difference was estimated from the data of temperature difference fluctuations with a variation of time. The amplitude and mean value of temperature difference fluctuations with respect to the elasped time appeared to decrease with decreasing the surface tension of liquid phase. The overall heat transfer coefficient between the immersed heated and the bubble column increased with an increase in the gas velocity or solid fraction in the slurry phase, but it decreased with an increase in the surface tension of continuous liquid media. The overall heat coefficient in the slurry bubble column with relatively low surface tension media was well correlated in term of operating variables and dimensionless groups within this experimental conditions.

Cold Surges over Korean Peninsula Associated with Arctic Oscillation and the Role of Heat Source (극 진동에 연관된 한반도 한파와 열원의 역할)

  • Shin, Sung-Chul;Kim, Maeng-Ki;Lee, Woo-Seop
    • Journal of the Korean earth science society
    • /
    • v.27 no.3
    • /
    • pp.302-312
    • /
    • 2006
  • This study has investigated the effect of Arctic Oscillation (AO) on cold surge through atmospheric circulation and heat source analysis for the past winters from 1979 to 2004. The number of occurrence of cold surge in the negative AO phase is about 14.3% larger than that in the positive AO phase. The number of occurrence of cold surge per a month in the negative (positive) AO phase is about 1.33 (1.05), respectively, indicating that the negative AO phase has about 26.6% larger occurrence than the positive AO phase. It means that the cold surge has occurred frequently in particular months with the negative AO phase. And it also shows that surface temperature in the negative AO phase is about $0.6^{\circ}C$ lower than in positive AO phase. As a result of the analysis for the difference of heat source according to the intensity of AO, it shows that surface air temperature around the Korean peninsula in the negative AO phase is more lower than in positive AO phase by the intensification of cold advection term. However, heat source term cancels out the cooling effect by cold advection term, indicating that it suppresses the decrease in surface air temperature. It results in a small difference of $0.6^{\circ}C$ in surface air temperature between the positive and negative AO phase in spite of the significance of atmospheric circulation change.

Analysis of Fire Occurrence Characteristics According to Ignition Heat Sources (발화열원에 따른 화재발생 특성 분석)

  • Lee, Kyung-Su;Kim, Tae-Hyeung;Lee, Jae-Ou
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.280-289
    • /
    • 2022
  • Purpose: In this study, the characteristics of fire occurrence according to ignition heat sources such as operating equipment, cigarette/lighter fire, and flame/fire were analyzed. Method: One-way ANOVA and cross-analysis were used to analyze the characteristics of fire occurrence by verifying the difference between the ignition environment, fire damage status and scale, and cause of ignition according to the ignition heat source. Result: The fire occurrence characteristics were analyzed through As a result of the analysis, it was found that fires caused by operating devices occurred more frequently on weekdays than other ignition heat sources, and the number of victims and the number of victims were the highest, so mobilization of firefighting power and property damage were the greatest. The initial ignition was generated by electric and electronic devices, and the combustion was expanded by the synthetic resin. For fires caused by cigarette and lighter fires, the most fires occurred on Saturdays and Sundays, and the mobilization of the police force was more characteristic than the mobilization of the firefighting force. In particular, it was found that the initial ignition and combustion expansion were caused by paper, wood, and hay. Fires caused by sparks and sparks occurred most frequently on Saturdays and Sundays, and initial ignition and combustion expansion were found to be caused by paper, wood, and hay. In particular, it showed the characteristic that it occurred in the place farthest from the fire station. The common characteristic of all ignition heat sources was that the fire occurred most frequently in the afternoon time, and the fire type was predominantly the building structure fire, and only the ignition point was burned the most. Conclusion: In order to prevent fire and minimize damage, it is necessary to analyze the tendency of fire occurrence and to prepare appropriate preparations according to the fire occurrence factors. In order to analyze the characteristics of fire occurrence using public data in the future, it is necessary to standardize disaster data and to open and activate data.