• Title/Summary/Keyword: 換氣

Search Result 4,213, Processing Time 0.028 seconds

A study on the effects of exhaust emission standards on the required ventilation rate in vehicle tunnels (차량 배출가스 규제기준이 소요환기량에 미치는 연구)

  • Kim, Hyo-Gyu;Ryu, Ji-Oh;Song, Seog-Hun;Jung, Chang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.409-420
    • /
    • 2017
  • The amount of ventilation required in making the tunnel ventilation plan is an important factor for determining the capacity of the ventilation system. The amount of pollutant emission for each type of vehicle (basic emission amount for the design of ventilation volume) for estimating the required ventilation amount is based on the 'Standard for Allowing the Emission for the car manufacturing', proposed by Ministry of Environment. However, in 2013, the Ministry of Environment announced the 'Regulations on the calculation method of total emissions from vehicles' as a regulation for calculating the pollutants emitted from vehicles. In this regulation, there are the 'Emission factors for each type of vehicle'. Therefore, it is necessary to review the application of the Regulation to the estimation of the required ventilation volume for the road tunnel. In this study, the influence of the strengthened emission regulation in 2015 caused by the case of manipulation of emission volume for the diesel vehicle on the calculation of the required ventilation volume in the road tunnel has been checked. In addition, in this study, the required ventilation volume calculated according to the Standard for Allowing the Emission for the car manufacturing revised by Ministry of Environment and "Emission factors for each type of vehicle" and that calculated according to the EURO emission standard were compared for analysis. This study has implications that it provides the basic design data for calculating the reasonable ventilation capacity of the ventilation system based on the ground for calculating the required ventilation volume.

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

NUMERICAL STUDY OF AIR POLLUTION RATE DEPENDING ON TYPES OF VENTILATION SYSTEM IN UNDERGROUND PARKING LOT (환기방식에 따른 지하주차장 공기오염도의 수치연구)

  • Lim, Soo-Jung;Jang, Choon-Man;Rhee, Gwang-Hoon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.208-214
    • /
    • 2009
  • 지하 복수층 주차장은 도시의 밀집화 및 자동차의 급격한 증가로 인한 토지부족 및 주차난을 해소할 수 있는 좋은 방법이다. 하지만 인체유해 배출가스의 집중으로 환기의 중요성이 대두되는 추세에도 불구하고 실제로는 시공이 완료 된 후에나 오염도 측정이 가능하다. 이러한 이유로 CFD 시뮬레이션으로 시공이전의 지하 복수층 주차장의 공기오염도를 예측했다. CFD 시뮬레이션은 예산과 시간을 절감한 공기오염도 예측이 가능하다. 실제의 당산근린공원의 지하주차장을 대상으로 오염도를 예측했다. 급기에만 강제유동을 일으키는 2종과 배기에만 강제유동을 일으키는 3종 기계환기법, 그리고 급배기에 강제유동을 일으키는 1종기계환기법을 각각 적용하여 공기오염도를 계산했다. 지하1층과 지하2층의 입구 및 출구유속을 10, 15m/s로 하여 실내평균연령과 실내평균환기효율을 살펴보았다. 계산결과는 급기와 배기에 강제유동을 동시에 일으키는 1종 기계환기법의 값과 비교하였다.

  • PDF

공조기용 열교환기

  • 윤정인
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.10
    • /
    • pp.47-51
    • /
    • 2000
  • 최근 룸에어콘이나 패키지에어콘의 에너지 절약, 쾌척성 등에 대환 사용자나 회사로부터의 요구는 더더욱 높아지고 있다. 공조기의 중요한 구성요소 중 하나인 열교환기도 이러한 요구에 대응하여 기술개발이 계속해서 진행되고 있다. 공조용 열교환기를 설계할 때 가장 중요한 과체는 비용이냐 설치성 등의 제약조건올 만족하면서 필요한 교환열량을 달성하기 위해, 요구되는 열 전달계수(K)와 전열면적(A)의 곱인 KA값을 얼마나 확보하는가 하는 점에 있다. 그러나 이 외의 과제, 예를 들어 홴입력, 소음을 억제하기 위한 공기측 통풍저항의 감소, 증발온도에 영향을 마치는 관내압력손실의 감소 등도 중요한 과제이다. KA값 증대와 통풍저항억제를 동시에 판촉하기 위해 공조용 열교환기는 전면면적을 크게 하고 두께를 작게 하여 사용하는 것이 원칙이다. 또, 전열관의 관경도 관 둘레길이와 냉매분배성능 면에서 제약이 발생한다. 이와 같은 배경으로부터 공조용 열교환기는 판경 6~10 mm정도의 전열 관을 20~25mm길이로 배치한 핀튜브형 열교환기가 주류로 되어있다. 여기에서는 공조기에 널리 사용하고 있는 핀튜브형 열교환기에 대한 최근의 기술개발 사례를 소개하고자 한다.

  • PDF

Experimental Study on Performance Characteristics of Air-Conditioner with PF Heat Exchanger (PF 열교환기 적용 공조기 성능특성에 관한 실험연구)

  • Park, K.M.;Um, U.S.;Kwon, Y.C.;Chang, K.S.;Lee, S.J.
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.893-896
    • /
    • 2009
  • 본 연구에서는 공조용 실외기의 고효율화 및 소형화를 위해 응축기로 사용되고 있는 핀-관 열교환기를 동일한 전면면적의 PF 열교환기로 변경하여 성능변화 및 특성을 조사하였다. 이를 위해 3종의 PF 열교환기를 적용하여 공조기의 성능을 비교평가 하였다. 실험은 공기 엔탈피식 칼로리미터에서 공조기의 냉방능력과 소비전력을 측정하여 COP를 계산하였다. PF 열교환기를 적용한 경우에 핀-관 열교환기보다 냉방능력은 증가하고 소비전력은 감소하여 COP가 향상되었다. PF 열교환기의 핀 피치가 클수록 냉방능력과 COP는 감소하였다.

  • PDF

Improvement of Coverings and Ventilation Methods in 1-2W type Vinyl House and Growth Responses of Tomatoes (농가보급형 비닐하우스(1-2W형)의 피복 및 환기 개선에 의한 토마토의 생육반응)

  • Lee, Si-Young;Kim, Hyun-Hwan;Jeon, Hee;Kwon, Young-Sam;Lee, Ki-Myung
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1995.10a
    • /
    • pp.97-99
    • /
    • 1995
  • 원예생산시설에 대한 정부지원사업이 본격화 된 '91년부터 농가보급형 비닐하우스(1-2W형)는 '94년 현재 1,364ha가 농가에 보급되어 시설원예 현대화에 크게 기여하고 있지만, 피복자재를 매년 교체해야 하는데 따른 과다한 인건비 소요, 물받이 홈통부분에 말아올리기식의 천창환기에 따른 고온기 환기불량 등의 문제점을 안고 있다. 이러한 문제점을 해결하기 위해 폴리에털렌 테레프탈레이트(PET)필름이나 폴리카보네이트(PC)판으로 지붕부분을 피복하고, 측면을 망사혼입 필름이나 PET필름으로 피복하여 매년 피복재를 교체하지않도록 하고 천창환기는 양지붕형 온실의 천창환기방식을 도입하여 하우스내의 환기효율을 높여 토마토의 생육반응을 알아보고자 실험을 실시하였다. (중략)

  • PDF

Natural Ventilation Effect of Bending Panel Type Windows in Greenhouse (굴절패널방식 환기창의 자연환기 효과)

  • Lee, Si-Young;Kim, Jin-Young;Kim, Hyun-Hwan;Jeon, Hee
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.71-74
    • /
    • 2000
  • 일반적으로 온실은 저온기에는 보온이나 난방을 하면서 적극 사용하고 있으나 고온기에는 냉방에 소요되는 에너지가 난방에 비해 상대적으로 많이 소요되므로 온실의 활용도가 떨어지게 된다. 자연환기 시스템은 에너지를 사용하지 않거나 최소한으로 줄여 온실내 온도를 최소한 외부와 동일하게 하거나 낮게 하기 위한 장치라고 할 수 있다. 자연환기를 위한 환기창으로 유리온실이나 경질판 온실과 같은 양지붕형 온실에서는 측창으로 3Way방식이나 권취식, 프로젝트방식 등 다양한 환기창을 사용하고 있으나 천창은 주로 온실 길이방향의 연속형 창틀을 랙앤피니언이나 X형 개폐암으로 개폐하는 프로젝트 방식을 많이 사용하고 있다. (중략)

  • PDF

A Hydrogen Sensor Experiment on the Ventilation Performance of a Cavity upon Hydrogen Leakage and Its CFD Simulation (수소 센서를 이용한 밀폐공간의 수소 누출 시 환기성능에 대한 실험 및 CFD 시뮬레이션)

  • Kim, Young-Doo;Shin, Dong-Hoon;Chung, Tae-Yong;Nam, Jin-Hyun;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.59-62
    • /
    • 2007
  • 연료전지는 수소를 이용하여 전기를 생산하는 발전 시스템으로 운전 중 수소 누출과 폭발의 위험성을 항상 수반하고 있다. 따라서 안전성의 확보를 위해 연료전지 시스템 내부에서 수소 누출 시 유e동 특성으로 인한 특정 부근 농도 정체와 환기의 영향을 파악하는 것이 필요하다. 실험 장치와 전산유체역학 프로그램을 사용하여 챔버 내 수소의 유통 특성과 환기구에 따른 환기의 영향을 확인하였다. 수소의 누출 속도와 양에 따라 유동장의 형태는 크게 변하였으며 환기구의 위치와 크기는 특정 부근의 농도정체와 챔버 내 전체적인 수소 농도에 영향을 미침으로서 안정성을 확보하는 중요한 인자임을 알 수 있었다. 예측 결과를 실제 실험 모델과 비교하여 그 타당성을 검토하였으며 차후 가정용 연료전지 모듈의 환기구 설계에 적용할 수 있다.

  • PDF

Development of Ventilation Silencer for Noise Reduction of Apartments (공동주택 층간소음 저감을 위한 환기장치용 소음기 개발)

  • Oh, J.W.;Lee, J.S.;Lee, J.H.;Lee, S.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1247-1251
    • /
    • 2006
  • 공동주택의 보급 증가에 따라 화장실과 같이 환기용 덕트를 통한 층간 소음전달 문제가 예상되어 환기용 덕트에 간단히 설치하여 층간 소음 전달을 차단할 수 있는 환기장치용 소음기를 개발하였다. 본 개발품은 소음 차단 기능이 확실하고, 구조가 간단하며 분해조립이 가능하여 설치 및 유지보수가 용이한 제품이다. 또한 습기에 의한 부식이 없고, 먼지와 습기를 쉽게 제거할 수 있는 특징이 있다. 성능시험 결과 환기용 덕트를 통한 소음의 전달을 10dB 이상 저감시킬 수 있고, 삽입에 의한 압력손실 2mmAq 이하가 됨을 확인하였다.

  • PDF