• Title/Summary/Keyword: 傳記

Search Result 106,464, Processing Time 0.112 seconds

A study on digital locking device design using detection distance 13.4mm of human body sensing type magnetic field coil (인체 감지형 자기장 코일의 감지거리 13.4mm를 이용한 디지털 잠금장치 설계에 관한 연구)

  • Lee, In-Sang;Song, Je-Ho;Bang, Jun-Ho;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study evaluated a digital locking device design using detection distance of 13.4mm of a human body sensing type magnetic field coil. In contrast to digital locking devices that are used nowadays, the existing serial number entering buttons, lighting, number cover, corresponding pcb, exterior case, and data delivery cables have been deleted and are only composed of control ON/OFF power switches and emergency terminals. When the magnetic field coil substrates installed inside the inner case detects the electric resistance delivered from the opposite side of the 12mm interval exterior contacting the glass body part, the corresponding induced current flows. At this time, the magnetic field coil takes the role as a sensor when coil frequency of the circular coil is transformed. The magnetic coil as a sensor detects a change in the oscillation frequency output before and after the body is detected. This is then amplified to larger than 2,000%, transformed into digital signals, and delivered to exclusive software to compare and search for embedded data. The detection time followed by the touch area of the body standard to a $12.8{\emptyset}$ magnetic field coil was 30% contrast at 0.08sec and 80% contrast at 0.03sec, in which the detection distance was 13.4mm, showing the best level.

A Study on the Corrosion Inhibition Measurement Method of Carbon Steel in Various Inhibited Solutions (부식억제제가 함유된 용액중에서 탄소강의 부식억제능 측정법)

  • 원덕수;김영근;이성민;고영태
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.05a
    • /
    • pp.108-108
    • /
    • 1998
  • 일반적으로 탄소강은 수용액 중에 노출될 경우 전면부식에 의한 손상을 받는다. 그러나 부식방지를 위하여 부식억제제를 적용할 경우, 탄소강의 부식거동은 현저한 변화를 겪게된다. 이러한 부식거동의 변화는 첨가되는 부식억제제의 종류에 따라 분 류할 수가 있는데, 양극부식억제제, 음극부식억제제 그리고 이들의 혼합부식억제제로 분류할 수가 있다. 현장에 적용된 부식억제제 시스템 중에는 자동차용 부동액과 가스히터용 열전달 매체액이 있다. 이러한 부식억제제가 적용된 시스댐은 정확한 부식억제능의 평가에 의한 그 교체 시기의 결정이 매우 중요하다. 교체 시기가 빠를 경우, 유지비용이 과다하게 소요되는 문제가 있으며, 교체시기가 늦을 경우 설비의 부식을 초래하는 문제 가 있다. 따라서 부식억제제의 정확한 성능 평가법은 매우 중요하며, 이에 대한 다양 한 연구가 진행 중이다. 부식억제제가 함유된 용액의 부식억제성능을 평가하는 방법에는 대표적으로 무게 감량법을 이용하고 있다. 이 방법은 다종의 금속이 적용된 자동차용 부동액을 실제 사용조건과 유사한 실험 조건에서 단기간, 가혹조건에서의 무게 감량에 의해 부식억 제능을 평가하는 방법이다. 그러나 이러한 방법은 특히 국부부식이 진행될 경우 부 식억제능을 정량화 하는데 어려움이 있다. 한편 전기화학적 측정방법으로는 분극곡선법을 이용한 $E_P$(공식개시전위), $E_R$(재부동태 화전위)의 측정법이 있다. 또한 부식억제피막의 안정성을 측정하기 위한 방법으로 인 위적인 양극전류 인가에 의한 피막의 파괴후에 피막이 복원가능 여부 및 그 속도 측 정에 의해 부식억제제의 건전성을 확인할 수가 었다. 본 연구에서는 가스히터의 주구성 재료인 A210 Gr Al의 탄소강을 사용하여, 사용기간이 5년 이상되어 부식억제 기능을 거의 상실한 것으로 여겨지는 열전달 매체액 과 신규 부식억제제가 적용된 시스템 등 객관적으로 확인된 부식억제제 시스랩에 대 하여 다양한 평가 방법을 동원 비교분석하고자 하였다. 실험은 KSM 2142에 의한 무게감량법, 분극곡선 측정에 의한 $E_P$(공식개시전위), $E_R$(재부동태화전위) 측정, 시간에 따른 자연전위 변화 측정 빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다.

  • PDF

A CLINICAL EVALUATION OF A BLEACHING STRIP CONTAINING 2.9% HYDROGEN PEROXIDE (2.9% 과산화수소를 함유한 부착형 미백제의 임상적 효능과 안전성에 관한 연구)

  • Park Eun-Sook;Seong So-Rae;Hong Seong-Tae;Kim Ji-Eun;Lee So-Young;Hwang Soo-Youn;Lee Shin-Jae;Jin Bo-Hyoung;Son Ho-Hyun;Cho Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.269-281
    • /
    • 2006
  • This study evaluated the effectiveness and safety of an experimental bleaching strip (Medison dental whitening strip. Samsung medical Co., Anyang, Korea) containing 2.9% hydrogen peroxide. Twenty-three volunteers used the bleaching strips for one and a half hour daily for 2 weeks. As control group. the same strips in which hydrogen peroxide was not included were used by 24 volunteers with the same protocol. The shade change (${\Delta}E^{*}$, color difference) of twelve anterior teeth was measured using Shade Vision (X-Rite Inc., S.W. Grandville, MI, USA). Chroma Meter (Minolta Co., Ltd. Osaka. Japan) and Vitapan classical shade guide (Vita Zahnfabrik, Germany). The shade change of overall teeth in the experimental group was significantly greater than that in the control group (p < 0.05) and was easily perceivable. The change resulted from the increase of lightness (CIE $L^{*}$ value) and the decrease of redness (CIE $a^{*}$ value) and yellowness (CIE $b^{*}$ value). The shade change of individual tooth was greatest in canine. and smallest in central incisor. The safety of the bleaching strip was also confirmed.

Validation of the LC-MS/MS Method for Ginsenoside Rb1 Analysis in Human Plasma (LC-MS/MS를 이용한 인체 혈장에서 Ginsenoside Rb1의 분석법 검증)

  • Han, Song-Hee;Kim, Yunjeong;Jeon, Ji-Young;Hwang, Minho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1753-1757
    • /
    • 2012
  • A new liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay for the quantification of ginsenoside Rb1 in human plasma was developed and validated. The separation was performed on a Agilent C18 column ($4.6mm{\times}150mm$, particle size 5 ${\mu}m$) with a gradient elution of 0.1% formic acid in water and 0.1% formic acid in methanol and a flow rate of 0.9 mL/min. The analyte was determined using electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode (m/z 1131.714${\rightarrow}$365.303). Human plasma samples were extracted with acetone : water (50:50) by the liquid-liquid extraction method. The method was linear over the dynamic range of 10~500 ng/mL with a correlation coefficient of r=0.9995. The intra-and inter-day precision over the concentration range of ginsenoside Rb1 was lower than 5.8% (correlation of variance, CV), and the accuracy was between 96.0~104.6%. This LC-MS/MS assay of ginsenoside Rb1 in human plasma is applicable for quantification in a pharmacokinetic study.

Effects of $K^+$ and $H^+$ on electromechanical properties of rabbit papillary muscle (토끼 유두근의 전기적 및 기계적 성질에 미치는 칼륨 및 수소이온의 영향)

  • Kim, Jun;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.16 no.1
    • /
    • pp.13-23
    • /
    • 1982
  • Effects of external pH and potassium concentrations on the electrical and mechanical properties were investigated on rabbit papillary muscle. Papillary muscles were perfused in horizontal chamber with Tris Tyrode solutions and action potential along with isometric tension was recorded simultaneously. Potassium concentrations were varied between 1 and 12 mM at low(6.9), normal(7.4) and high (7.9) external pH. The following results were obtained: 1) On rasing the potassium concentration from 1 to 12 mM resting membrane potentials decreased from $-88.8{\pm}2.8$ to $-66.4{\pm}1.2\;mV$ at normal pH and the amplitude of action potential decreased from $115.1{\pm}0.7$ to $97.5{\pm}2.8\;mV$. On lowering the potassium concentration, membrane hyperpolarized and at 1 mM potassium concentration resting potentials were $-107{\pm}2.2\;mV$. Duration of action potential especially $APD_{60}{\sim}APD_{90}$ increased($APD_{90}$: $214{\pm}15.8\;ms$ at 1 mM $K^+$ to $287{\pm}18.1\;ms$ at 12 mM $K^+$). 2) During acidosis membranes hyperpolarized by more than 20 mV within 1 min. and then slow recovery was observed during the following 10 min. During alkalosis membranes depolarized about 10 mV, which were maintained until washing with normal Tyrode solutions. 3) On lowering the external pH(7.9-6.5), duration of action potential increased progressively and it was most prominent at pH 6.5 and $K^+$ 1mM. 4) Magnitude of developed tension was $0.6{\pm}0.14\;g/mm^2$ at normal pH and potassium concentration (stimulus frequency : 60/min). Relative isometric tension to normal value increased along the increment of stimulus frequency($44.2{\pm}4.2%$ at 6/min to $271{\pm}86.7%$ at 180/min). Force-frequency relations were altered quantitatively during the perfusion with different external pH solutions. 5) Developed tension did not show marked variation within the range of $2{\sim}8\;mM$ potassium concentrations. Positive inotropism was observed at less than 2 mM $K^+$ and negative inotropism beyond 12 mM $K^+$ concentrations. From the above results we concluded that the effects of potassium ion concentration on electrical and mechanical properties of rabbit papillary muscle are related to the changes in surface negative charge due to acid base disturbances.

  • PDF

The Periodical Change and Regional Distribution Characteristics of Regional Speciality Products in Chungcheongbuk-do (충청북도 지역특산물의 시기별 변화와 지역적 분포 특성)

  • Choi, Bo-mi;Kang, Chang-Sook
    • Journal of the Korean association of regional geographers
    • /
    • v.21 no.1
    • /
    • pp.79-97
    • /
    • 2015
  • Regional specialty products should be representative of the regional characteristics for a long time, this was not done for geographical research. This study examines current the regional specialty products on 12 web-site of the cities counties in 2013 and the products registered on the Tosan(土産) category from old Jiriji(古地理誌) in Chungcheongbuk-do. Futhermore, the study analyzed periodical change and regional distribution characteristics of regional specialty products. Major findings are as Follows. First, current the regional specialty products types are 4 products(crops, marine products, forest products, livestock products) and 3 manufactures (processed food, handicraft, cosmetic products). Among the regional specialty products, various crops and processed food were distributed in all the regions. Second, the traditional products types are 5 products(crops, marine products, forest products, livestock products, mineral products) and 1 manufactures(handicraft) that registered on the old Jiriji in the Joseon Dynasty period. The jujube, ginseng and honey were cultivated in the most regions. Third, the traditional products types are 4 products except for marine products and 1 manufactures(handicraft) that registered on the old Jiriji in the period of Japanese colonial rule. Its total item numbers of the regional specialty products are greatly decreased, but items of handicraft relatively increased in the Danyang and Goesan regions. Finally, regional analyzing of current local items shows that there are only a few regional specialty products(18 items) that have historical traditionality.

  • PDF

The Strategic Adoption of Creative Industry and Its Impact on the Reconstruction of Cultural Identity in Andong Province (문화콘텐츠산업의 전략적 수용과 안동 문화정체성의 재구성)

  • Cho, Gwan-Yeon
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.5
    • /
    • pp.568-581
    • /
    • 2011
  • Having gone through the international financial crisis in 1997, the Korean government has sought a new future economic breakthrough. In this line, the government chose the cultural contents business and has supported this area intensively. With the cultural contents promotion policy initiated to foster the world-class culture business based on the traditional Korean culture, Andong, which has diverse cultural traditions, was rediscovered. The Andong local government and the local power elites decided that this promotion policy can not only be an opportunity to invigorate the sluggish local economy, but also help eliminate the old-fashioned image of Andong, and thus actively promoted the cultural contents business. However, there's a conflict among the local elites over which cultural tradition should be chosen as a genuine local cultural tradition. The different views and efforts regarding the cultural identity of the region by each entity not only contributed significantly to the recovery of the local economy by revitalizing tourism, but also helped the region gain an advantageous position in competition with other regions over limited resources. This progress became the groundwork for attracting major institutions and facilities, which are essential for the revitalization of the local economy.

  • PDF

A Study on the Construction Method of the Songsanri Tombs Using Geophysical Exploration Method (송산리 고분군의 지구물리학적 조사를 통한 고분축조방법 고찰)

  • Suh, Mancheol;Lee, Changwhan;Jeong, Gyeok;Kim, Donghyun
    • Journal of Conservation Science
    • /
    • v.6 no.1 s.7
    • /
    • pp.61-70
    • /
    • 1997
  • An integrated geophysical survey was conducted to study a construction method of the Sonsanri tombs including the Muryong royal tomb. With the distribution of soil resistivity and self potential values, the boundary between original ground and the construction site was delineated clearly. The original ground has relatively high resistivity of $1,000\~1,500$ ohm-m and low self-potential values of $0{\pm}3mV/m$, while the construction site has low resistivity less than 200 ohm-m and quite high self-potential values of $-20\~30mV/m$. It is interpreted that the open site for construction of subsurface tomb has the size of about 35 m in the north-south direction. Big difference in characteristics of ground between the tomb site and the original site gives a clue for the construction method of tombs in Baekje dynasty. The site was opened about 35 meters in the north-south direction and then a mold structure was constructed with a brick frame outside. The brick frame consists of bricks cemented each other and structually combined. The mold structure was removed from inside after refill of the opened construction site with some cemented rock debris and soil.

  • PDF

A Research on PV-connected ESS dissemination strategy considering the effects of GHG reduction (온실가스감축효과를 고려한 태양광 연계형 에너지저장장치(ESS) 보급전략에 대한 연구)

  • Lee, Wongoo;KIM, Kang-Won;KIM, Balho H.
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.94-100
    • /
    • 2016
  • ESS(Energy Storage System) is an important source that keeps power supply stable and utilizes electricity efficiently. For example, ESS contributes to resolve power supply imbalance, stabilize new renewable energy output and regulate frequency. ESS is predicted to be expanded to 55.9GWh of installed capacity by 2023, which is 30 times more than that of 2014. To raise competitiveness of domestic ESS industry in this increasing world market, we have disseminated load-shift ESS for continuous power supply imbalance with FR ESS, and also necessity to secure domestic track record is required. However in case of FR ESS, utility of installing thermal power plant is generally generated within 5% range of rated capacity, so that scalability of domestic market is low without dramatic increase of thermal power plant. Necessity of load-shift ESS dissemination is also decreasing effected by surplus backup power securement policy, raising demand for new dissemination model. New dissemination model is promising for $CO_2$ reduction effect in spite of intermittent output. By stabilizing new renewable energy output in connection with new renewable energy, and regulating system input timing of new renewable energy generation rate, it is prospected model for 'post-2020' regime and energy industry. This research presents a policy alternatives of REC multiplier calculation method to induce investment after outlining PV-connected ESS charge/discharge mode to reduce GHG emission, This alternative is projected to utilize GHG emission reduction methodology for 'Post-2020' regime, big issue of new energy policy.

Influence of the Geometry on the Natural Convection Heat Transfer inside a Vertical Cylinder (수직 원형관내 자연대류 열전달에서 기하구조의 영향)

  • Ohk, Seung-Min;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.97-103
    • /
    • 2015
  • Natural convection heat transfer rates in vertical pipes were measured varying the diameter, length, and roughness of vertical cylinder. To achieve high Rayleigh number with relatively small test rig, mass transfer experiments instead of heat transfer were performed based on the analogy. Prandtl number was 2,014. The length of vertical cylinder was 0.1m, 0.3m, and 0.5m, which correspond to GrL $4.2{\times}10^7$, $1.1{\times}10^9$, and $5.5{\times}10^9$. To each length of vertical cylinder, the heat transfer rates were measured varying the iameter 0.005m, 0.01m, and 0.03m. The heat transfer rate for a short length pipe(0.1m) agreed with the prediction from Le Fevre correlation developed for a vertical plate for all diameter. The heat transfer rate decreases as the diameter and the length of the pipe increases. The heat transfer rate inside of vertical cylinder is affected by roughness only for a laminar flow regime.