• Title/Summary/Keyword: {\gamma}$-ray

Search Result 1,836, Processing Time 0.03 seconds

The Effect of Gamma ray irradiation on Paper Properties (감마선 조사처리가 지류의 물성에 미치는 영향)

  • Jeong, Hye-Young;Choi, Kyoung-Hwa;Park, Ji-Hee;Jung, Pil-Mun;Choi, Jong-Il
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.42 no.3
    • /
    • pp.43-49
    • /
    • 2010
  • Recently, the use of fumigants for pest control of paper cultural heritages are limited because of the high toxicity of fumigants and the production of environment-harmfully compounds. Therefore, many non-chemical methods have been discussed and experimented. And it is recently focused on gamma radiation, which is one of non-chemical methods, for pest control of paper cultural heritage in Korea. In this paper, we carried out a gamma ray irradiation of papers including Hanji, copy paper, filter paper and then analyzed a physical properties and optical properties of paper sample to estimate the effect of gamma ray irradiation on paper properties. In result, gamma radiation have adverse effect on a physical properties and optical properties of paper, especially Hanji. Therefore, we have to carefully consider about using of gamma ray for pest control of paper cultural heritages.

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector (스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • Nuclear power plant has increased continuously for power production in all over the world and the interest about nuclear accident and the dismantling of aging nuclear power plant has been a growing. The leaked radioactive source that is generated by radiation accidents must detect and remove to minimized the damage as soon as possible. Gamma-ray detection system that have been developed until now cannot provide the precise position of radioactive sources because they detect and imaging the position of radiation sources in just two dimensions. In this paper, stereo gamma ray detection system has developed and the algorithm for calculation of the distance has implemented to be able to measure the distribution of the leakage gamma ray source for the system. Stereo camera calibration for distance detection was conducted with the correction pattern and LED light and we carried out performance test of the system for the LED light source and a gamma ray source. In both experiments the results of the performance test, it was confirmed to have a 5% error. The results of this paper is used as a material for the development of gamma-ray imaging device.

Investigation of the Susceptibility of Arctic Arthrobacter sp. PAMC 25486 to Mutagens (극지미생물 Arthrobacter sp. PAMC 25486의 돌연변이 유발 물질에 대한 감수성 평가)

  • Kim, Sang-geun;Choi, Jong-il;Han, Se Jong
    • Journal of Radiation Industry
    • /
    • v.8 no.2
    • /
    • pp.105-109
    • /
    • 2014
  • This study was conducted to investigate the sensitivity of Arthrobacter sp. PAMC 25486 to various mutagens. ${\gamma}-ray$, UV-ray, Ethyl methane sulfonate (EMS) and hydrogen peroxide ($H_2O_2$) were used as mutagen, and the survival rate of Arthrobacter sp. was measured at various doses of ${\gamma}-ray$ and UV-ray, and concentrations of EMS and $H_2O_2$. Decimal reduction dose ($D_{10}$ value) of Arthrobacter sp. was determined 370 Gy for a gamma irradiation treatment, 0.019 J for a UV ray, 2.5 mM for EMS, and 230 mM for $H_2O_2$. This result will be applied for the development of superior mutant strain of Arctic bacteria producing valuable compounds.

Measurements of X-Ray and Gamma Ray Dosse Rate by the Silicon P-N Junction Diode (Silicon P-N Junction Diode에 대한 X-Ray 및 Gamma-Ray 의 Dose Ratec 측정)

  • 정만영;김덕진
    • 전기의세계
    • /
    • v.13 no.3
    • /
    • pp.13-20
    • /
    • 1964
  • The measurements of X-ray and Gamma-ray Dose Rate have been successfully made by measuring the short circuit current of the Silicon P-N Junction Diode being irradiated. The short circuit current flows when a silicon P-N Junction Diode is irradiated by X-ray of Gammaray radiations due to photovoltaic effect. A brief analysis is given in order to verify the proportionality of a short circuit current to the Dose Rate. Using this method, measurements of X-ray Dose Rate were carried out in the range of 0.05-1600 r/m successfully. The calibration was made by comparing with Victoreen condenser r-meter. Some advantages in this Dose Rate meter over a condenser r-meter were found. One can measure a continous variation of X-ray Dose Rate with this rate meter at the control console of X-ray device.

  • PDF

Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray (즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정)

  • 송병철;박용준;지광용
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy(NIPS) system measures the prompt gamma-ray emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many element in either solid or liquid wastes. In this study, the full-energy-peak (FEP) efficiency calibration for a HPGe detector was constructed in the ${\gamma}$-ray energy range from 80 keV to 8 MeV, using $^{l33}$Ba and >TEX>$^{152}Eu$ RI sources and $ ^{35}Cl(n, ${\gamma}$)^{36}Cl$ thermal neutron captured reaction. The FEP efficiency curve for the higher energies using the $^{35}Cl(n, ${\gamma}$)^{36}Cl$ reaction was normalized with the curve obtained from the RI sources, since the accurate activity of its prompt ${\gamma}$-ray is unknown. The average thermal neutron flux was theoretically calculated using the FEP efficiency curve for the KCl standard solutions. The NIPS system equipped with a ${\gamma}$-${\gamma}$ coincidence setup with two n-type coaxial HPGe detectors was considered in order to reduce the interfering ${\gamma}$-ray background. The FEP efficiency curve for the ${\gamma}$-${\gamma}$ coincidence system was also obtained for full energy range. The performance of the normal and coincidence NIPS system was tested by comparing signal-to-noise ratio in each mode using the reference sample.e.

  • PDF

Studies of Soybean Improvement by ${\gamma}$-ray and Chemical Mutagens -I. Comparison of the effects of EMS, Ei, and ${\gamma}$-rays in soybean(preliminary report) (돌연변이 유기에 의한 대두 품종개량연구 -I. 대두에 대한 EMS, EI 및 ${\gamma}$선처리효과비교(예보))

  • Shin-Han Kwon;Kun-Hyuk Im;Cheong-Yeol Sohn;Jong-Sun Eun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.7 no.1
    • /
    • pp.139-144
    • /
    • 1969
  • 1. In order to obtain useful mutants such as early maturity, resistance to lodging, high protein and oil content, and capability of high yield, dormant seeds of two soybean varieties, Jang Dan Baik Mok and Clark, were treated with ${\gamma}$-ray, Ethyl Methane Sulfonate(EMS), Ethylene Imine(EI)and combinations of ${\gamma}$-ray and EMS or EI. 2. The germination rate and survival rate in a variety Jang Dan Baik Mok were significantly decreased with ${\gamma}$-ray treatment while it was not the same in the Clark variety. A significant decrease for seedling height measured at 14 and 21 days after sowing was found with the increase of ${\gamma}$-ray dose in both varieties. 3. Germination rates in both varieties were significantly decreased as EI concentration increases, particularly severe damage in germination was observed at 0.008 Mo. concentration. Germination rate damages were found with EMS concentration increases in the variety Jang Dan Baik Mok while no regular responses in seedling height were observed in the variety Clark. 4. Germination rate was significantly lowered with the combined treatment of EMS and ${\gamma}$-ray 24KR than that of EMS alone. In the treatments of ${\gamma}$-ray with three levels of EI concentration, the combined treatments except 24KR+EI 0.002 Mol. resulted in better germination than of EI alone. In both varieties, significant reduction in seedling height was observed in the combined treatments of ${\gamma}$-ray with various concentrations of EMS, whereas stimulation effect on seedling height was found with treatment of ${\gamma}$-ray EI +0.08Mol. 5. Germination rate, survival rate, and plant height as criteria of radio sensitivity, variety Jang Dan Baik Mok is moze sensitive to ${\gamma}$-ray, EMS, and EI than the variety Clark, and the varietal difference in responsibility to mutagen may be due to the genetic-constitution of the varieties.

  • PDF

A Study on the Treatment of Secondary Effluent by ${\gamma}-ray$ Irradiation ($\gamma$-선의 조사를 이용한 하수처리장 방류수 처리에 관한 연구)

  • 이면주;정영도;박순달
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.106-114
    • /
    • 1998
  • This study was carried out for the purpose of industrial reuse of effluent released from activated sludge unit by $\gamma $-ray irradiation technique. The dissolved organic carbon in the effluent of an activated sludge unit is mostly refractory or inert material which are difficult to be degraded by micro organism. The effluent generated from activated sludge unit was irradiated with Co$^{60}$ $\gamma $-ray under condition of air bubbling. The effects of irradiation on the pH, COD, TOC, color, molecular weight distribution were investigated by membrane filtration and u.v.-spectrum analysis. With increasing dose, the TOC was decreased smoothly. The COD was increased at lower dose, while the COD was decreased at higher dose. The TOC and COD, however, were decreased smoothly when TiO$_{2}$ was added to the solution. It was thought that the differential decreasing trend of COD and TOC in according to the absence or presence of TiO$_{2}$ was due to the molecular weight distribution shifted from group of higher molecular weight to group of lower one which are more easy to be decomposed. The removal efficiency of color was 71.5% and it was increased to 85.7% when TiO$_{2}$ was added to the solution. The $\gamma $-ray irradiation was effective on the production of chlorine.

  • PDF

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

γ-Ray Shielding Behaviors of Some Nuclear Engineering Materials

  • Mann, Kulwinder Singh
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.792-800
    • /
    • 2017
  • The essential requirement of a material to be used for engineering purposes at nuclear establishments is its ability to attenuate the most penetrating ionizing radiations, gamma $({\gamma})-rays$. Mostly, high-Z materials such as heavy concrete, lead, mercury, and their mixtures or alloys have been used in the construction of nuclear establishments and thus termed as nuclear engineering materials (NEM). The NEM are classified into two categories, namely opaque and transparent, depending on their behavior towards the visible spectrum of EM waves. The majority of NEM are opaque. By contrast, various types of glass, which are transparent to visible light, are necessary at certain places in the nuclear establishments. In the present study, ${\gamma}-ray$ shielding behaviors (GSB) of six glass samples (transparent NEM) were evaluated and compared with some opaque NEM in a wide range of energy (15 keV-15 MeV) and optical thickness (OT). The study was performed by computing various ${\gamma}-ray$ shielding parameters (GSP) such as the mass attenuation coefficient, equivalent atomic number, and buildup factor. A self-designed and validated computer-program, the buildup factor-tool, was used for various computations. It has been established that some glass samples show good GSB, thus can safely be used in the construction of nuclear establishments in conjunction with the opaque NEM as well.