• Title/Summary/Keyword:

Search Result 280, Processing Time 0.028 seconds

The Function of Social Criticism Film Implemented in Animation Film (애니메이션 영화 <창, 2012>에 구현된 시사고발 영화 기능)

  • Lee, Hyun-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.3
    • /
    • pp.150-161
    • /
    • 2017
  • The short animation directed by Sang-Ho Yeon has led the sympathy and reflection of audiences through reveling the violence of the military in the form of the social criticism film. The explores the social value of animation by the content of social criticism, not for entertainment uses but for public interest. This research addresses how the function of social criticism implements in animation film, especially, its narratives and direction. In the light of this, firstly, literature will review the general characteristics of social criticism films, Secondly, based on literature reviews, analysis tools will be drew, thirdly, the case study regarding will be processed by focusing on The function of social criticism, the technique of direction and expression of animation. As a result of this research, shows unique traits because of the hierarchical and exclusive characteristics of military culture, which differs from general characteristics of social criticism films dealing with historic and social issues. In addition to this, the function of social criticism is effectively implemented in animation film, by the creative narratives and technique of direction by a director, Sang-Ho Yeon.

Energy Consumptions and Daylight Illumination levels of a Multi-beded Patient Room according to the Window Shapes and Shading (창의 형태 및 차양 계획에 따른 다인 병실의 에너지소비량과 주광조도의 평가 및 분석)

  • Choi, Changdae;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.3
    • /
    • pp.29-39
    • /
    • 2012
  • Window and shading designs have a great influence on energy consumption and daylighting in buildings. As far as energy is concerned, small window area is advantageous. But it is not good to the patient healing in hospital. So it is important to find out the optimum window shape which is favorable for both energy consumption and patient healing. In this study, annual energy consumption and daylight illumination levels were analyzed according to the window shapes and shading devices for a multi-beded patient room in hospitals. The simulations were conducted for 19 different cases by COMFEN 4.0 computer simulation program. The results of this paper are as follows. First, window to wall area ratio and shading devices have great influences on annual energy consumption. But it is a problem in that they decrease significantly daylight level in bed room. Second, considering the same energy consumption, reducing the width of window rather than the hight of window is desirable for the secure of daylight level. Third, increase of the number of horizontal shade is not desirable in south face of the building for the energy consumption and daylight level. Fourth, sun shade is not necessary in north face of the building for the energy consumption and daylight level.

An Efficient Sliding Window Algorithm Using Adaptive-Length Guard Window for Turbo Decoders

  • Lim, Hyun-Tack;Kim, Yong-Sang;Cheun, Kyung-Whoon
    • Journal of Communications and Networks
    • /
    • v.14 no.2
    • /
    • pp.195-198
    • /
    • 2012
  • An efficient sliding window algorithm employing an adaptive-length guard window for turbo decoders is proposed. The proposed algorithm results in significant complexity reductions, especially for small sliding window lengths where the additional computational complexity required for the guard window is critical.

Robust Tracking Algorithm for Moving Object using Kalman Filter and Variable Search Window Technique (칼만 필터와 가변적 탐색 윈도우 기법을 적용한 강인한 이동 물체 추적 알고리즘)

  • Kim, Young-Kyun;Hyeon, Byeong-Yong;Cho, Young-Wan;Seo, Ki-Sung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.7
    • /
    • pp.673-679
    • /
    • 2012
  • This paper introduces robust tracking algorithm for fast and erratic moving object. CAMSHIFT algorithm has less computation and efficient performance for object tracking. However, the method fails to track a object if it moves out of search window by fast velocity and/or large movement. The size of the search window in CAMSHIFT algorithm should be selected manually also. To solve these problems, we propose an efficient prediction technique for fast movement of object using Kalman Filter with automatic initial setting and variable configuration technique for search window. The proposed method is compared to the traditional CAMSHIFT algorithm for searching and tracking performance of objects on test image frames.

The Effects of VM Components on Store Image and Purchasing Intention of Fashion Stores - Focused on Facade Color and Show Window Type - (의류매장의 VM 구성요소가 점포이미지와 구매의도에 미치는 영향 - 파사드 색상과 쇼 윈도우 유형을 중심으로 -)

  • Lee, Mi-Sook
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.3
    • /
    • pp.416-429
    • /
    • 2012
  • The purpose of this study was to examine the effects of VM components(facade color and show window type) on store image and purchasing intention of fashion stores. The subjects were 428 male and female university students in Daejeon and Chungnam province. The measuring instruments were 6 stimuli manipulated by $3{\times}2$ factorial design of facade color and show window type, and a self-administrated questionnaire consisted of store image, purchasing intention, and subjects' demographic characteristics. The results were as follows. First, facade color mainly affected store image and purchasing intention. White color was preferred as more positive images(pleasurable, comfortable, neat, and modern), and showed higher purchasing intention than brown color. Second, show window type affected some store images. Semi-open type was perceived as more pleasurable image than enclosed type, whereas enclosed type was perceived as more luxurious, neat, and attractive image than semi-open type. However, show window type didn't affect purchasing intention. Third, subject' sex affected store image and purchasing intention. Male subjects perceived more positively on store image and had higher purchasing intention than females. This study suggested that facade color and show window type are important VM components affecting store image and purchasing intention.

A Study on Relationship Insulation Thickness and Infiltration Load by Window (단열재 두께 변화와 창호 침기 부하와의 관계)

  • Choi, Jeong-Min;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.422-427
    • /
    • 2012
  • This study investigates on the relationship between total load which is caused by infiltration and insulation thickness against compensation effect. As the result of experiment, the PVC(Synthetic resins sash) window frame in airtightness is superior to the AL(Aluminum sash) window frame. In this study, as the increasing of insulation thickness in reference building does not reduce significantly cooling load, the compensation effect due to airtightness against infiltration is very small. But the compensation effect against infiltration can be closely related with heating load. Therefore, the proper thermal insulation thickness can be needed respect to cooling and heating load.

A Study on the Show Window Display Affecting the Purchase of Clothing Stores (쇼윈도 디스플레이가 의류매장의 구매에 미치는 영향에 관한 연구)

  • Kim, Tae-Young;Seo, You-Seok
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.96-105
    • /
    • 2012
  • The fundamental purpose of this study is whether Show Window Display actually affect on purchase and if it does, how much Show Window Display have influence on the buyer's satisfaction. Show windows are most important at clothing stores. The show open types of domestic clothing stores are usually open-type and semi open-type. Show Window Display types of low and middle prices stores are generally opened, horizontal and storied type and the shape, height, opening type and use of ground floor are different by regional distinct features. Generally Show Window Display are consisted by lights, mannequins and directed props. In buying patterns, an impulse buying has more stronger effect than a scheduled buying, a substituted buying and non-buying. An impulse buying are strongly affected by Design and others are prices. The reason why Show Window Display affecting on purchase is the satisfaction of Design and the strong stimulus to purchase(impulse buying), and then Show window Display used by all components strongly has an effect on it. Factors of purchase desires were Design, price and quality in order and factors of purchase motivations were the motivation of clothing design and the motivation of impulse buying. Thus the effects of Show Window Display and factors of purchase motivations are same. As a result of this study, differentiated Show Window Display methods of clothing stores affect the value of goods, the stimulus of purchase and fostering sales effectiveness. Therefore the instruction of Show Window Display methods are indicated by this study.

  • PDF

An Analysis on Thermal Performance and Economic of Heat Recovery Ventilation System Integrated with Window (창호통합형 배열회수 환기시스템의 열성능 및 경제성 평가)

  • Sung, Uk-Joo;Cho, Soo;Song, Kyoo-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.646-655
    • /
    • 2012
  • This study is intended to analyze the thermal performance and evaluate the applicability about non-duct type heat recovery ventilation system integrated with window. Eventually, economic analysis of the system is conducted according to building energy saving ratio of it. As results of the thermal performance, the U-factor of the window conducted on the basis of KS F 2278 appears to $1.8W/m^2K$, and the effective heat exchange efficiency of the ventilator conducted on the basis of KS B 6879 appears 49.95% for cooling, 66.89% for heating. In the applicability evaluated by TRNSYS 16, the caes of applying the heat recovery ventilator integrated with window is found to reduce the cooling or heating load by 2.9% or 13.5% than the non-ventilator case. The results of economic analysis taking a side of consumer is verified as the payback is 3 years, and the accumulated earning is 1,408,133 won in terms of '600,000 won/unit' for initial cost, 10 years for useful life of the system.

A Study on the Effect Applying the Energy Variation and Temperature by Window type of Building (건물의 창호종류에 따른 에너지 변화량 및 온도에 미치는 영향에 관한 연구)

  • Chung, Hwan-Kyo;Kim, Young-Il;Cho, Jin-Hwan;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.211-220
    • /
    • 2012
  • In study to investigate losing energy of building in window, we analyze the heating loss parts in the material of structure throughout modeling of window system. Also, by making modeling in the building using simulation, we investigate the heating load variation of building in window. According to the type of windows and the material of structure, we analyze the energy variation of building and a temperature variation.

Performance Analysis of Summertime Heat Transfer Characteristics of the Double Skin Window for Plant Factory (식물공장 이중창호의 하절기 열전달 성능 분석)

  • So, Jae-Hyun;Kim, Woo-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.351-357
    • /
    • 2012
  • To reduce the summertime cooling load of a plant factory, a concept design was performed for the double skin window which utilizes the low temperature air from a ground coupled heat exchanger. The design parameters were selected as the number of cavity air inlet, the cavity thickness, the location of cavity air inlet, and the configuration of cavity air outlet. A parametric study was conducted in a systematic way to evaluate the heat transfer characteristics of the double skin window. As the number of cavity air inlet and the cavity thickness increase, the heat flux from outside air to indoor air was decreased. The effect of the location of cavity air inlet was not significant and the larger cavity air outlet area gave us relatively better heat blocking performance from outside hot air. This study demonstrated that it is possible to develop an improved double skin window by utilizing a ground coupled heat exchanger.