• Title/Summary/Keyword:

Search Result 982, Processing Time 0.038 seconds

Atmospheric Analysis on the Meteo-tsunami Case Occurred on 31 March 2007 at the Yellow Sea of South Korea (2007년 3월 31일 서해에서 발생한 기상해일에 대한 기상학적 분석)

  • Kim, Hyunsu;Kim, Yoo-Keun;Woo, Seung-Buhm;Kim, Myung-Seok
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.1999-2014
    • /
    • 2014
  • A meteo-tsunami occurred along the coastline of South Korea on 31 March 2007, with an estimated maximum amplitude of 240 cm in Yeonggwang (YG). In this study, we investigated the synoptic weather systems around the Yellow sea including the Bohai Bay and Shandong Peninsula using a weather research and forecast model and weather charts of the surface pressure level, upper pressure level and auxiliary analysis. We found that 4-lows passed through the Yellow sea from the Shandung Peninsula to Korea during 5 days. Moreover, the passage of the cold front and the locally heavy rain with a sudden pressure change may make the resonance response in the near-shore and ocean with a regular time-lag. The sea-level pressure disturbance and absolute vorticity in 500 hPa projected over the Yellow sea was propagated with a similar velocity to the coastline of South Korea at the time that meteo-tsunami occurred.

Effects of a Flow Guide on the Arcing History in a Thermal Puffer Plasma Chamber (유동 가이드가 열파퍼 플라즈마 챔버의 아크현상 이력에 미치는 영향)

  • Lee, Jong-Chul;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.832-839
    • /
    • 2007
  • The geometry and dimensions of an expansion chamber are decisive factors in thermal puffer plasma chamber designs. Because they together dominate the temperature and speed at which the cooling gas from the chamber flows back through a flow channel to the arcing zone for the successful interruption of fault currents. In this study, we calculated the flow and mass transfer driven by arc plasma, and investigated the effects of a flow guide installed inside a thermal puffer plasma chamber. It is found that the existing cold gas of the chamber mixes with hot gases entrained from the arcing zone and is subjected to compression due to pressure build-up in the chamber. The pressure build-up with the flow guide is larger than that without due to a vortex which rotates clockwise around the chamber center. By the reverse pressure gradient, the mixing gas of the chamber flows back out for cooling down the residual plasma near current zero. In the case with the flow guide, the temperature just before current zero is lower than that without, and the Cu concentration with high electrical conductivity is also less than that without the flow guide.

Experimental and Numerical Studies in a Vortex Tube

  • Sohn Chang-Hyun;Kim Chang-Soo;Jung Ui-Hyun;Lakshmana Gowda B.H.L
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.418-425
    • /
    • 2006
  • The present investigation deals with the study of the internal flow phenomena of the counterflow type vortex tube using experimental testing and numerical simulation. Visualization was carried out using the surface tracing method, injecting dye on the vortex tube wall using a needle. Vortex tube is made of acrylic to visualize the surface particle tracing and the input air pressure was varied from 0.1MPa to 0.3MPa. The experimentally visualized results on the tube show that there is an apparent sudden changing of the trajectory on the vortex tube wall which was observed in every experimental test case. This may indicate the stagnation position of the vortex flow. The visualized stagnation position moves towards the vortex generator with increase in cold flow ratio and input pressure. Three-dimensional computational study is also conducted to obtain more detailed flow information in the vortex tube. Calculated total pressure, static pressure and total temperature distributions in the vortex tube were in good agreement with the experimental data. The computational particle trace on the vortex tube wall is very similar to that observed in experiments.

A Measurement and Evaluation on the Indoor Thermal Conditions in Spring of a New Training ship (신조 운항실습선의 봄철 실내 온열환경 실측평가)

  • Shin, Dong-Keol;Lee, Jin-Uk;Lee, Hyong-Ki;Park, Youn-Cheol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.939-946
    • /
    • 2007
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those, supplied and controlled by ship's HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured on a newly-launched training ship during 2nd through 5th of April, 2007. Followings are the results of this study. (1)Because only partial loads are needed in spring season, the air volume from diffusers are measured as below 20%. (2)The temperatures are ranged between $20{\sim}25^{\circ}C$ and those are within comfort temperature range proposed by AHREA. (3)But humidities in cabins are very low and it could be the reason of a cold and/or a skin disease. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of low humidity, only 16.1% among the measured data are satisfied with the comfort standard range proposed by ASHREA. To improve the predictability and the comfort, HVAC should maintain the humidity as $40{\sim}60%$.

A Construction Case of Flow Equal Distribution System in Series Connection (직렬 연결구조의 유량균등분배 시스템 시공사례)

  • Jeong, Ung-Sung;Lee, Sung-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.64-65
    • /
    • 2017
  • The existing hot and cold water supply system have a few problems such as construct ability, damage of the building, maintenance and the unequal distribution of water supply flow. So the system has needs to be improved and the Flow Equal Distribution System(FEDS) in series connection has been innovated by Idin Lab which relieve the existing problems. Thus, the purpose of this study is aimed to show the merits of FEDS with an real example of construction site of Wirye Terrace, D builder. 1. FEDS enables builders to save construction cost as the system in series connection does not need to equip both allotters and loop piping system. 2. FEDS contains a cartridge of water saving function so it mainly reduce the unequal distribution of flow and sudden temperature deviation of hot water supply at the same time. 3. FEDS allows repairer to maintain the water supply system at the same floor that could get rid of disharmony between dwellers who live the upper/lower story of the same building. Therefore, the FEDS will be applied when the building is remodeled and constructed.

  • PDF

Estimation of Non Working Day Corresponding to Statistical Data of Korea Meteorological Administration - Focused on Cheonju - (기상청 통계자료기반 기후요소에 의한 작업불능일 산정 - 청주지역을 중심으로 -)

  • Baek, Dae-Hyun;Joung, Woung-Sun;Park, In-Beom;Song, Seung-Heon;Baek, Byung-Hoon;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.141-145
    • /
    • 2008
  • In this paper, non working day for the construction project in Cheongju region considering weather condition for 30 years from 1971 to 2000 and 10 years from 1991 to 2000 as statistical periods was estimated. In Cheongju region, there was no remarkable difference between them because non working day for outside and half outside work was 157days and for interior work 144days at statistics for 30 years., and utside and half outside work was 159days and for interior work 142days at statistics for 10 years.. However, non working day due to high temperature is slightly increased, and non working day due to cold weather is slightly decreased in the case that the recent statistical data was used caused by global warming. Non working day due to rainfall was 23 days at statistics for 30 years, and it was 28 days at statistics for 10 years.

  • PDF

Improvement of Spinal Central Pain by Brachial Plexus Block -A case report- (상완 신경총 차단에 의한 척수성 중추통증의 완화 -증례보고-)

  • Kim, Ok Sun;Lee, Woo Yong;Yoo, Byung Hoon;Lim, Yun Hee;Kim, Seung Oh
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.241-243
    • /
    • 2006
  • Central pain is defined as pain associated with lesions of the central nervous system, and is among the most intractable of chronic pain syndromes. A 47 year-old-female, who had right arm and shoulder pain, was diagnosed with syringomyelia of the Arnold Chiari malformation type I and received foramen magnum decompression and a syringo-subarachnoid shunt. After the operation, the evoked pain was improved, but she complained of a continuous burning pain, coupled with cold and tactile allodynia. This symptom failed to fully subside on administration of oral medicine; therefore, brachial plexus block was performed, which relieved her pain transiently. Through repeated trials, a gradual decrease in the pain intensity and frequency was found. However, the way in which brachial plexus block improves spinal central pain is not completely known.

A Visualization Study on the Characteristics of Droplets Impinging on a Hot Surface (고온 열판에 충돌하는 액적의 거동에 대한 유동가시화 연구)

  • Kim, Dong-Yeon;Yi, Seung-Jae;Kim, Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • Hydrophobic characteristics of high temperature metal surface were investigated by high-speed visualization of water droplet impact. An aluminum plate was used as the sample plate and the initial diameter of a water droplet was 2 mm. Transient behavior of a single droplet impinging on the surface with and without heating was captured by using a high speed camera running at 4,000 frames per second. The Leidenfrost phenomenon was demonstrated for the case of $300^{\circ}C$ surface temperature, however there was no rebounding of droplet on the cold plate due to hydrophilic nature. The experimental results show that the shape evolution of a droplet impinging on the surface varies with the Weber number, i.e. the ratio of impact inertia to capillary force. The overall water-repellent characteristics of the heated surface was very similar to that of the super hydrophobic surfaces.

The Study of the Veneer Pretreatment with Aluminum Sulfate Solution on the Reduction of Urea Formaldehyde Resin Spreading Content for the Manufacture of Plywood (황산알미늄용액의 단판(單板) 전처리(前處理)에 따른 합판용(合板用) 요소수지(尿素樹脂) 도포량의 감소에 관한 연구(硏究))

  • Lee, Hwa-Hyoung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.3-8
    • /
    • 1988
  • This study was carried out to examine the effect of pretreatment of veneer with aluminum sulfate solution for the manufacture of the kapur plywood on the reduction of urea resin spread. The results were as follows: 1. Specific gravities of plywoods made of the kapur veneers ranged from 0.83 to 0.84 and their moisture contents based on air dry weight showed from 10.6% to 11.4%. These met the Korean Industrial Standards. 2. In the case of dry shear strength for the 3rd class plywood, 40% reduction- spread met K S as well as normal urea resin spread. pH of the aluminum sulfate solution gave better result at pH 4.5 and pH 6 than at pH 3. For the manufacture of the 2nd class plywood, hot and cold water-wet shear strength show the best results at the following conditions; such as 20% reduction spread, pH 4.5 of aluminum sulfate solution and all veneer treatment.

  • PDF

Improvement of the Efficiency of a Twin-fluid Nozzle using Ultrasonic Vibration (초음파 가진을 이용한 2-유체 노즐의 효율 향상)

  • 주은선;나우정;정진도;송민근;이경열
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.317-326
    • /
    • 2002
  • Characteristics of a twin-fluid spray with ultrasonic vibration were examined in order to obtain a high efficiency of cold-fog spray of the automatic pest control machine which has been widely used in protected horticulture recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive $\pi$-type vibrator were used applied as the ultrasonic transducers with a frequency of 28 kHz. All experiments were conducted in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving-quality method by ultrasonic forced within liquid, and a combined-use method with both of the indirect vibration method and the improving quality method. It was found that the ultrasonic energy increased the atomization efficiency of spray droplets about 10% and especially much more in the case of the combined-use method.