• 제목/요약/키워드:

검색결과 973건 처리시간 0.024초

상열감을 호소하는 소양인의 도적강기탕 치험 3례 (A Case Series of Dojeokganggi-tang for Hot flush in Soyangin Cold Pattern Patients)

  • 김국화;박지은;최효재;이슬;채한;김지환;이정윤
    • 사상체질의학회지
    • /
    • 제36권1호
    • /
    • pp.31-42
    • /
    • 2024
  • Introduction This case series report an attempt to treat Sasang constitutional medicine on Soyangin patients with unspecified hot flush. Methods The patients in this case were diagnosed as Soyangin cold pattern and treated with herb medicine Dojeokgangi-tang. Treatment outcome was monitored retrospectively. Results Persistent hot flush significantly improved to normal levels in all 3 Soyangin patients, and 2 out of 3 showed the effect within 4 weeks, those with more chronic symptoms required more time. Discussion This study suggests the significance of Sasang constitutional medicine treatment in Soyangin patients with Hot flush. Additionally, the characteristics of patients with hot flush presented in this study were verified as meaningful diagnostics indicator of Soyangin lesser yang wind damage. Furthermore, it emphasizes the value of original symptoms as a standard for evaluating treatment effectiveness.

조강포틀랜드시멘트를 사용한 한중콘크리트의 현장품질 특성 (The On-site Quality Characteristics of the Cold Weather Concrete using High Early Strength Portland Cement)

  • 이원암;엄태선;유재상;이종열;강지훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.224-227
    • /
    • 2004
  • The cement can be influenced by the temperature. Especially, when it is cold weather, it causes some problems in such properties as mixing, placing and curing of concrete. According to the Concrete Standard Specification(2003), in case of the average daily outdoor temperature below $4^{\circ}C$, it recommends to use the cold weather concrete. In this research, the on-site quality characteristics of the cold weather concrete using high early strength portland cement(Type III cement) were studied. As a result, the cold weather concrete using high early strength portland cement can obtain its excellent properties and benefit the cost of construction.

  • PDF

연안역의 냉배수 확산모델링 (Diffusion Modelling of Cold Discharge on Coastal waters)

  • 김종규;김종화
    • 수산해양교육연구
    • /
    • 제13권2호
    • /
    • pp.132-145
    • /
    • 2001
  • The cold discharge from LNG(liquefied natural gas) terminal makes the water temperature around the terminal fall down. This temperature reduction may result in serious changes on marine ecosystem of the coastal area. The numerical model experiments of material transport and tidal circulation in the inner bay, Chinhae Bay are investigated in the dispersion of cold discharge from LNG terminal. The condition of ambient water is exposed to tide, tidal current and cold discharge temperature. Simple numerical model experiments highlight the importance of tidal circulation and cold discharge at each case and some results are discussed. The results of this study can be used as the guideline for the site selection of LNG terminals and long-term marine environmental impact assessment.

  • PDF

진한가열증(眞寒假熱證)을 보인 소음인(少陰人) 망양증(亡陽證) 환자(患者) 치험(治驗) 1례(例) (A Case of Soeumin Mang-yang Syndrome Compared to Cold Syndrome with Pseudo-heat Symptoms)

  • 김일환;박혜선;이상민;김효수
    • 사상체질의학회지
    • /
    • 제17권3호
    • /
    • pp.150-155
    • /
    • 2005
  • 1. Objectives This case is aimed to verify the relation of Soeurnin Mang-yang Syndrome and Cold Syndrome with pseudo-heat syndrome. 2. Methods The patient has high fever, general body sweating, thirst and constipitation is diagnosed as Soeumin Mang-yang Syndrome. Mang-yang Syndrome one of the symptoms in the Exterior Febrile Disease induced from the Kidney affected by Heat in Soeumin(少陰人) marked by spontaneous sweating and fever with chills. This syndrome is similar to Cold syndrome with pseudo-heat symptoms in general symptoms and pathologic process. Therefore, We medicate Doksampalmul-tang to this patient who diagnosed as Soeumin Mang-yang Syndrome. 3. Results and Conclusions The symptoms that the patient has fever, sweating, thirst and constipitation are solved after the medication. This means recovery of Yang-Energy in Kidney and the spleen.

  • PDF

스테인리스 강판(SUS420)의 냉간단조용 금형개발에 관한 연구 (A Study on the Development of Cold Forging Dies for Stainless Steel Sheet (SUS420))

  • 김엽래;김세환;유헌일
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.877-885
    • /
    • 1995
  • Cold forging die for metal scissor is made by electric discharge machine. The impression of female die is made by electric discharge machine, the heat treatment is applied, and the impression is polished. When we forge goods by using this kind of die, the abrasion is severe and the crack occurs after forging about 240 strokes. Because the die should be frequently produced in the case, the cost rises, the work is delayed, and the precesion of goods is not good. Therefore, the electric discharge machine was not used in this study. Main die was produced by making hob, installing the hob to cold hobbing press, indenting the die material, and cold hobbing the impression. The die life was increased to 5,000-6,000 strokes in this case. In the future study, the die life will be increased to 10,000 strokes by changing the following : (1) the pre-treatment of slug, (2) the structure of die block, (3) the heat treatment of die material

이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용 (Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather)

  • 홍석민;백대현;김종;전충근;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.57-60
    • /
    • 2008
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete and mass concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 6 and 15℃ even in case outside temperature drops -9℃ below zero until the 2nd day from piling, and in the case of mass concrete, with the maximum temperature difference between the center and surface less than 4℃, crack occurrence index was close to 2 and no hydration heat crack occurred by internal constraint. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

저온축열용 포접화합물에 냉각특성에 관한 실험적 연구 (A study on cooling characteristics of clathrate compound for cold storage applications)

  • 한영옥;김진흥
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.205-214
    • /
    • 1999
  • The objective of this paper is to investigate the thermal properties of TMA clathrate compound applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are performed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of density, temperature of heat source and charging quantity in TMA clathrate compound. The results are summarized as follows:1) $-15^{\circ}C$ is not proper as the temperature of heat source because the temperature of subcooling is above $8.3^{\circ}C$ 2) temperature of phase change is dropped as the temperature of heat source is lower, 3) the effect of subcooling suppression with about 8$^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 26, 27, and 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 26 and 30wt%. Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$. Thus, it is concluded that TMA clathrate compound has enough thermal properties as the cold storage medium for building air-conditioning.

  • PDF

저온축열용 포접화합물의 열물성에 관한 실험적 연구 (An Experimental Study on Thermal Properties of Clathrate for Cold Storage Applications)

  • 한영옥;정낙규;김진흥
    • 설비공학논문집
    • /
    • 제12권8호
    • /
    • pp.725-734
    • /
    • 2000
  • The objective of this paper is to investigate the thermal properties of TMA clathrate applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are peformed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of concentrations and temperature of heat source in TMA clathrate. The results are summarized as follows; 1) temperature of phase change is dropped as the temperature of heat source is lower, 2) the effect of subcooling suppression with about $9.3^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 29wt% and 30wt% . Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$ Thus, it is concluded that TMA clathrate has proper properties as the cold storage medium for building air-conditioning.

  • PDF

소음인 태양병궐음증으로 진단한 갑상선 기능저하증으로 인한 수족냉증 치험 1례 (A Case of Cold Hypersensitivity from Hypothyroidism of Soeumin Diagnosed as Greater Yang Disease Reverting Yin Pattern)

  • 이용재;이슬;김소형;이정윤;채한
    • 사상체질의학회지
    • /
    • 제31권1호
    • /
    • pp.102-112
    • /
    • 2019
  • Objectives The purpose of this case study was to report that cold hypersensitivity caused by hypothyroidism was alleviated by diagnosing and treating as Greater Yang Disease Reverting Yin Pattern. Methods The patient was administered Insamosuyu-tang and Sammisamyu-tang and treated with acupuncture. Global Assessment Scale (GAS) and Digital Infrared Thermal Imaging (DITI) was used to assess the improvements of symptoms. Results and Conclusions Cold hypersensitivity of hands and feet was improved to GAS 20, and hours of sleep were increased from one to six. On DITI, the increase of the temperature were 1-3 degree celsius on the chest and the abdomen, 0.2-1 degree on the forearms and the hands, 1-2 degree on the thighs, and 0.2-0.5 degree on the shins and the feet.

$^{99m}Tc$-MDP 골스캔에서 냉소로 나타난 전이 암의 분석 (Cold Lesions in $^{99m}Tc$-MDP Bone Scans of Patients with Skeletal Metastases)

  • 최창운;양형인;배상균;이동수;손인;정준기;이명철;고창순
    • 대한핵의학회지
    • /
    • 제27권1호
    • /
    • pp.98-103
    • /
    • 1993
  • The present study was purposed to evaluate the incidence and the characteristics of metastatic "cold" lesions in $^{99m}Tc$-MDP bone scans of adult patients with solid malignancies. There were 29 cold lesions in 24 patients. The incidence of cold lesions was about 1% of total cases of bone scans for the patients with malignancy, or 2.5% of cases with bone metastases. Th primary sites of malignancies were lung (four cases), uterine cervix (three cases), kidney, nasopharynx, thyroid, urinary bladder, prostate, lymphoma (two cases each other), liver, breast and others (one case each other). But the relative incidence of cold lesion in lung cancer and breast cancer was low. The most frequent site of cold lesion was spine, and pelvis, skull and rib were followed. The incidence of cold lesion was related to the regional incidence of bone metastases. The size of the cold lesions was greater than that of the hot. There were six cases of single cold lesion without any other abnormalities and two cases of cold lesion which were initially hot. So it should be considered that bone metastases might be presented as cold lesions in bone scan.

  • PDF