• Title/Summary/Keyword: ,Hot-Line

Search Result 507, Processing Time 0.037 seconds

On the use of an acoustic sensor for measuring the level of a zinc pot (용융아연욕 탕면 높이 측정을 위한 초음파 센서의 사용에 관하여)

  • 박상덕;임태균;이옥산
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.836-839
    • /
    • 1996
  • Throughout CGL (Continuous Galvanizing Line) in steel works, zinc-coated steel sheets are produced which are used where long-running corrosion resistivity is required. During the galvanizing process, top dross is created and floated on the zinc pot. Because the dross leaves ill patterns on the coated sheets, a robot system is developed to automatically collect and remove the top dross. It consists of a robot and its carriage system, a pot level sensor, a system controller, and special robot tools. For the first time the level of zinc pot must be measured and fed back to the robot controller to avoid submersion of the robot hand into the hot zinc pot. In this paper, acoustic distance sensor is tested as a candidate for the pot level sensor in the view point of hot environment. Some considerations on the use of the acoustic distance sensor will be denoted.

  • PDF

Development of the QOC Monitoring System in Downcoiler (권취기에서의 단차 회피 제어 감시 시스템)

  • 최용준;황원호;이영진;이민철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.955-958
    • /
    • 2003
  • Strip top mark is one of the major problem areas in hot strip coiling operation. The key for good coiling is having a precise detection instrument of strip head end and an understanding of QOC(quick open control) control algorithm and mechanism. Therefore, this study aims at developing QOC monitoring system that is useful for avoiding strip top mark at coiling process. In this study, strip movement between mandrel and unit roll(wrapper roll) was thoroughly studied using high speed camera. The monitoring system was developed to calculate QOC open time and to estimate optimal open time values for good coiling operation. Its performance has been proven by extensive field tests on downcoiler of #2 Hot Strip Mill Line in Pohang Works.

  • PDF

Predictions of Strip Temperatures for Finishing Mill of Gwangyang Hot Rolling Line $\#3$ (광양 3열연 사상압연에서의 스탠드간 판 온도 예측)

  • Kim H. J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.349-358
    • /
    • 2004
  • The strip temperature history of finishing mill process is one of the most important factors to stabilize the facilities and to achieve the better product quality including a better prediction of roll force etc. The ultimate goal of this study is to improve scientific understanding of the finishing mill process in the view of heat transfer science. Finishing mill cooling facilities of KwangYang $\#3$ hot rolling are introduced and heat transfer analyses from FET to FDT are particularly focused in this study Three major tasks are successfully achieved as follows: 1) The temperature Prediction Models are developed. 2) The average absolute error is found to be less then 10 Celsius degree (about $8.5^{\circ}C$). 3) Prediction rate (less then $\bar{+}20$) are $10.2\%$ improved $(80.1\;\rightarrow\;90.3\%)$.

  • PDF

A Lifetime Prediction Modeling for PMOSFET Degraded by Hot-Carrier (II) (Hot-Carrier로 인한 PMOSFET의 소자 수명시간 예측 모델링 II)

  • 정우표;류동렬;양광선;박종태;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.9
    • /
    • pp.30-37
    • /
    • 1993
  • In this paper, we present a simple and general lifetime prediction model for PMOSFET by using the correlation between transconductance degradation and gate current influence to solve a problem that that I$_{b}$ is dependent on drain structure. The suggested model is applied to a different channel, drain structured PMOSFET. For all PMOSFETs, dg$_{m}$/g$_{m}$ of PMOSFET appears with one straight line about Q$_{g}$, therefore, this model using I$_{g}$ is consistent with experiment result independently of channel, drain structure. It is, therefore, proposed that a model using I$_{g}$ has a general applicability for PMOSFET's.

  • PDF

A study on the change of turbulence structure in a diffuser (확대관의 난류구조 변동에 관한 연구)

  • Lee, Jang-Hwan;Han,Yong-Un
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.4
    • /
    • pp.503-508
    • /
    • 1997
  • The change of the structure of homogeneous turbulence subject to irrotational strains has been studied in an anti-Morel type diffuser (center matched cubic contour) using the hot wire anemometry. It was observed that the profiles of mean velocities and turbulence velocities along the center line were stable at the entrance region but rapidly changed near the matching point. The wall induced turbulence at the entrance region grows fast and was diffused toward the center at downstream. It was also observed that the axial turbulence grows faster than the radial one in the middle region of the diffusing flow and that the diffusing process has the vortex compression mechanism due to the conservation of angular momentum. These phenomena are frequently observed at the initial flow region of the free jet.

A Study on the boronizing treatment of hot forgeability of STD61 steel by the paste method (열간단조용 STD 61강의 Boronizing 처리에 의한 표면 물성 변화)

  • 이영생
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.190-196
    • /
    • 1999
  • Hot forgeability of STD 61 steel was boronzed in boronizing paste mainly consisted of B4C and Na2B4O7 at various temperatures and times. Microhardness and thickness of boride layers were measured and distributions of B, Si, Cr and V on the cross section of specimen were observed by EPMA line analysis. Microscopic examination and results of EPMA showed that the boride layer consisted of two layers outer layer of FeB and inner layer of Fe2B. Microhardness of these boride layers was in the range of Hv 1800~2300. Thickness of boride layer increased with times and temperatures. Si-rich $\alpha$ layer was formed between boride layer and matrix. Element such as Cr concentration as Cr23(B, C)6 beneath the boride layer.

  • PDF

Estimation of Durability of corrugated Steel Pipes Made of Hot-Dip Galvanized Sheet Steels (용융아연 도금강판으로 제조된 파형강관의 내구수명예측)

  • 김종상
    • Journal of Surface Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.347-358
    • /
    • 1994
  • Estimation of durability for corrugated steel pipe(CSP) has been evaluated by using several analytical methods. This study, using a plain hot-dip galvanized CSP as the base line, addresses additional coatings such as polymers sand bituminous coatings that may be used to achieve a desired design life of at least 50years. The behavior of both the soil side and the effluent side of the pipe have been studied. It is estimated that CSP generally provides outstanding dura-bility with regard to soil side effects, and that virtually any required service life can be attained by selecting appropri-ate coatingss and/or thickness of steel substrate. This study is limited to storm drainage systemss carrying naturally oc-curring surface water only. The recommendation in this report do not apply to sanitary or industrial waste sewers or other conduits used to carry corrosive effluents.

  • PDF

HALO EMISSION OF THE CAT’S EYE NEBULA, NGC 6543: SHOCK EXCITATION BY FAST STELLAR WINDS

  • Hyung, Siek;Lee, Seong-Jae
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.3
    • /
    • pp.173-180
    • /
    • 2002
  • Images taken with the Chandra X-ray telescope have for the the first time revealed the central, wind-driven, hot bubble (Chu et al. 2001), while Hubble Space Telescope (HST) WFPC2 images of the Cat's Eye nebula, NGC 6543, show that the temperature of the halo region of angular radius ~ 20", is much higher than that of the inner bright H II region. With the coupling of a photoionization calculation to a hydrodynamic simulation, we predict the observed 〔O III〕 line intensities of the halo region with the same O abundance as in the core H II region: oxygen abundance gradient does not appear to exist in the NGC 6543 inner halo. An interaction between a (leaky) fast stellar wind and halo gas may cause the higher excitation temperatures in the halo region and the inner hot bubble region observed with the Chandra X-ray telescope.

An analytical model for the prediction of strip temperatures in hot strip rolling (열간 압연 중 판의 온도 분포 모델 개발)

  • Kim, J.B.;Lee, J.H.;Hwang, S.M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.04a
    • /
    • pp.97-102
    • /
    • 2009
  • In hot strip rolling, sound prediction of the temperature of the strip is vital for achieving the desired finishing mill draft temperature (FDT). In this paper, a precision on-line model for the prediction of temperature distributions along the thickness of the strip in the finishing mill is presented. The model consists of an analytic model for the prediction of temperature distributions in the inter-stand zone, and a semi-analytic model for the prediction of temperature distributions in the bite zone in which thermal boundary conditions as well as heat generation due to deformation are predicted by finite element-based, approximate models. The prediction accuracy of the proposed model is examined through comparison with predictions from a finite element process model.

  • PDF

금속용탕면 높이 측정을 위한 거리센서의 특성

  • 이왕하;임태균;박상덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.590-596
    • /
    • 1994
  • In a CGL(Continuous Galvanizing Line) in steel making plants, zinc-coated steel sheets are produced. These sheets are used where long running corrosion resistivity is required. During the coating process top dross is produced, being harmful to the quality of the coating. To collect and remove this top dross, an automation system is developed consisting of a robot and its carriage system, a pot level sensor, a system controller, and specialtools. Forthe first, the level of the pot must be measured and fed back to the robot controller to avoid submersion of the robot hand in the hot pot. In this paper,acoustic and laser distance sensors are tested for the appropriate pot lvel sensor, especially the former in the view point of hot environment.

  • PDF