• Title/Summary/Keyword: $r_p$

Search Result 20,251, Processing Time 0.06 seconds

A Study on the Heavy Metals Concentrations in the Air of the Dental Laboratories, in the Blood and Urine of Dental Laboratory Technicians (치과기공실 공기중 및 치과기공사의 혈액, 요중 중금속 함량에 관한 연구)

  • Cha, Sung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.11-24
    • /
    • 1988
  • The purpose of this study was to determine the concentration of cadmium, nickel and chromium in the air of the work-place, blood of and urine of workers and compare the level of those heavy metals by the duration of work, work-place, process of work, smoking and other factors. In this study, 48 male dental laboratory technicans and 72 office workers as the control group were subjected. The concentration of cadmium, nickel and chromium in their blood sand urine, and that of heavy metals in the air of their work-rooms were examined and analyzed from June I 1987 to September 30, 1987. The results were as follows : 1. The concentration of cadmium in the air was the highest in the porcelain part, $0.0087{\pm}0.0016mg/m^3$, that of nickel was the highest in the crown bridge part, $0.4253{\pm}0.0052mg/m^3$, and that of chrnmium was highest in the partial denture part, $0.1063{\pm}0.0024mg/m^3$. 2. cadmium, nickel and chromium concentrations in the blood and urine of dental laboratory techincians were higher that in the office workers'. Especially the concentration of cadmium in the blood($1.92{\pm}1.23{\mu}g$/100ml) of th dental laboratory techician was about two times as high as that in the office workers'($0.90{\pm}0.73{\mu}g$/100ml), and the concentration of nickel in the urine($48.53{\pm}38.83{\mu}g$/e) of the dental laboratory thchnician was about two times as high as that in the office worker's($20.24{\pm}15.35{\mu}g$/e). 3. there was no difference in the concentration of cadmium, nickel and chromium in the blood and urine with a longer duration of work. 4. The concentration of cadmium and chromium in the blood and urine differed significantly depending upon the place of work. The concentration of cadmium was the highest in the blood of dental laboratory technicians working kin the poreclain part marking at $2.53{\pm}1.08{\mu}g$/100ml. The chromium level was the heighest in the blood of partial denture park workers with a concentration of $3.60{\pm}1.02{\mu}g$/100ml. Concerning the level of cadmium in urine, it was the highest in the porcelain part workers with a concentration of $3.41{\pm}3.15{\mu}g$/e. 5. The concentration of cadmium in the urine of metal trimming and polishing group($2.64{\pm}2.41{\mu}g$/e) was higher than that of non-metal trimming and polishing group($1.39{\pm}1.18{\mu}g$/e). 6. The concentration of chromium in the blood of smoking group($2.46{\pm}1.54{\mu}g$/100ml)was higher than that lf non-smoking group($1.54{\pm}1.25{\mu}g$/100ml). 7. The height positive correlation coefficient was shown between the concentration of nickel and chromium in the blood among the all correlations between 3metals(Cd, Ni, Cr) in the blood and those in urine. The correlation coefficient was relatively high(r=0.605,,p<0.01). In general, the higher the concentration of heavy metals in the air of work places the higher the concention lf them in the blood and urine of workers, mere attention should be paid to the working environment of dental laboratory workers, Furthermore, continuous biological monitoring and further research are required for an efficient health management for dental laboratory workers.

  • PDF

Influence of Gravel Content and Nitrogen Application on Nitrogen Leaching by the Leachate and Chinese Cabbage Growth in Highland (자갈함량과 질소시비량이 고랭지 배추재배시 침투수에 의한 질소용탈 및 생육에 미치는 영향)

  • Park, Chol-Soo;Lee, Gye-Jun;Jung, Yeong-Sang;Joo, Jin-Ho;Hwang, Seon-Woong
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Continuous monocropping of Chinese cabbage in Gangwon highland increased gravel and sand contents due to surface soil erosion. Nutrient leaching and Chinese cabbage growth were investigated with different treatments of gravel contents and nitrogen application levels by using $0.5m^2$ Wagner pots. Gravel contents were 0, 10, 30, 50, 70, and 90%(w/w), nitrogen application levels were 60, 120, and 240 kg/ha, and manure compost application rate was 15 ton per hectare, respectively. Wagner pots were filled with loamy sand soil mixed with 5 cm-sized gravels. Fresh weight of Chinese cabbage was decreased as gravel contents in soil increased, and particularly severely decreased at 240 kg-N/ha. Yields of Chinese cabbage were remarkably decreased at the rate of 60 kg-N/ha with 30% gravel content and 120 kg-N/ha with 50% gravel content. Most of Chinese cabbages were severely wilted by heavy N application at the rate of 240 kg-N/ha in the middle of growth stages regardless of gravel contents, while about 50% of Chinese cabbage showed wilting symptom in the treatment of more than 50% of gravel contents and 120 kg-N/ha. N content in leachate increased as gravel content and N application increased. The relationship between gravel content and N contents showed linear regression: N in leachate = 0.014(gravel content) -0.039 (r = 0.961). Particularly, $NH_4-N$ contents in leachates with more than 30% gravel content and 240 kg-N/ha ranged from $139{\sim}339mg/L$. Chinese cabbage growth in loamy sand soil containing 30%, and 50% gravel contents could be adversely affected by N application at the rate of 240, and 120 kg-N/ha, respectively.

G-, C-, and NOR-banding of Korean Native Pig Chromosomes (한국재래돼지의 G-, C-, 및 NOR-banding)

  • Sohn, S.H.;Kweon, O.S.;Baik, K.H.;Jung, W.;Cho, E.J.;Kang, M.Y.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.901-910
    • /
    • 2003
  • Using the G-, C-, and NOR-banding techniques, a karyotyping for Korean Native Pig was performed. Blood samples were collected from 50 male Korean Native Pigs that had been bred at the National Livestock Research Institute and then blood cells were prepared from in vitro cultures followed by karyotyping; G-, C-, and NOR-banding patterns of metaphase chromosomes were analyzed. The karyotype of Korean Native Pig is 38, XX or XY which consists of 5 pairs of submetacentric chromosomes(Group I), 2 pairs of acrocentric chromosomes with short p-arm(Group II), 5 pairs of medium metacentric chromosomes(Group III), 6 pairs of acrocentric chromosomes(Group IV) and metacentric X and Y sex chromosomes. On GTG-banding, the Korean Native Pig exhibited a typical and identical banding pattern in each homologous chromosomes. Overall chromosomal morphology and positions of typical landmarks of the Korean Native Pig were virtually identical to those of Committee for the Standardized Karyotype of the Domestic Pig(CSKDP). However, numbers of G-bands of the Korean Native Pig chromosomes were more than those of CSKDP. In chromosomes 1, 3, 5, 6, 7, 8, 13, 14, 15, 16, 17, 18 and X, the Korean Native Pig exhibited more separated bands as compared with CSKDP. In C-banding patterns, although the quantity of heterochromatin was variable in each chromosome, most of the Korean Native Pig chromosomes had heterochromatic C-bands on centromeres. However, the heterochromatic C-band was constantly observed on the whole Y chromosome. In AgNOR staining, the NORs were located at centromeres on the chromosomes 8 and 10. The number of NORs per metaphase ranged from 2 to 4 giving a mean value of 2.13. The number of NORs were distributed on all chromosome pair 10 but not on chromosome 8. The sizes of NORs were also differed between homologous chromosomes 8. Numbers of NORs of Korean Native Pig were significantly higher than those of Yorkshire. The pattern of pig NORs was polymorphic in breeds, individuals and cells, especially on chromosome 8.

Scheme on Environmental Risk Assessment and Management for Carbon Dioxide Sequestration in Sub-seabed Geological Structures in Korea (이산화탄소 해양 지중저장사업의 환경위해성평가관리 방안)

  • Choi, Tae-Seob;Lee, Jung-Suk;Lee, Kyu-Tae;Park, Young-Gyu;Hwang, Jin-Hwan;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2009
  • Carbon dioxide capture and storage (CCS) technology has been regarded as one of the most possible and practical option to reduce the emission of carbon dioxide ($CO_2$) and consequently to mitigate the climate change. Korean government also have started a 10-year R&D project on $CO_2$ storage in sea-bed geological structure including gas field and deep saline aquifer since 2005. Various relevant researches are carried out to cover the initial survey of suitable geological structure storage site, monitoring of the stored $CO_2$ behavior, basic design of $CO_2$ transport and storage process and the risk assessment and management related to $CO_2$ leakage from engineered and geological processes. Leakage of $CO_2$ to the marine environment can change the chemistry of seawater including the pH and carbonate composition and also influence adversely on the diverse living organisms in ecosystems. Recently, IMO (International Maritime Organization) have developed the risk assessment and management framework for the $CO_2$ sequestration in sub-seabed geological structures (CS-SSGS) and considered the sequestration as a waste management option to mitigate greenhouse gas emissions. This framework for CS-SSGS aims to provide generic guidance to the Contracting Parties to the London Convention and Protocol, in order to characterize the risks to the marine environment from CS-SSGS on a site-specific basis and also to collect the necessary information to develop a management strategy to address uncertainties and any residual risks. The environmental risk assessment (ERA) plan for $CO_2$ storage work should include site selection and characterization, exposure assessment with probable leak scenario, risk assessment from direct and in-direct impact to the living organisms and risk management strategy. Domestic trial of the $CO_2$ capture and sequestration in to the marine geologic formation also should be accomplished through risk management with specified ERA approaches based on the IMO framework. The risk assessment procedure for $CO_2$ marine storage should contain the following components; 1) prediction of leakage probabilities with the reliable leakage scenarios from both engineered and geological part, 2) understanding on physio-chemical fate of $CO_2$ in marine environment especially for the candidate sites, 3) exposure assessment methods for various receptors in marine environments, 4) database production on the toxic effect of $CO_2$ to the ecologically and economically important species, and finally 5) development of surveillance procedures on the environmental changes with adequate monitoring techniques.

  • PDF

Polycyclic Aromatic Hydrocarbons in Industrial Organic Sludge from Wastewater Treatment Facilities in Korea (폐수처리시설에서 발생된 유기성 슬러지에 함유된 다환방향족탄화수소의 농도 특성)

  • Nam, Seong-Nam;Lee, Mi-Young;Yeon, Jinmo;Jeon, Taewan;Shin, Sun Kyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.574-582
    • /
    • 2012
  • This study presents the concentrations of the polycyclic aromatic hydrocarbons (PAHs) listed as priority pollutants by United States Environmental Protection Agency (US EPA), in 98 sludges from 54 industrial wastewater treatment facilities of South Korea. The mean concentrations of ${\Sigma}_{16}PAHs$ were ranged from 32.5 ${\mu}g/kg-dw$ to 1189.3 ${\mu}g/kg-dw$ by industries, and the highest content was found in the petrochemical industry, followed by chemical, clothing manufacturing and dying, pulp and papermaking, secondary wastewater treatment, and food/beverage producing industries. Comparisons to the EU and Danish standards of ${\Sigma}_{16}PAHs$ in sewage sludge for land application showed only two samples (one from petrochemical, and the other from chemical industry) exceeded the limits. ANOVA test with PAH concentrations as variables revealed no statistically significant influences by industrial types and sampling time (i.e., seasonal variations). Pearson correlations between individual PAHs showed strong relationships (r>0.7) among 4-ring PAHs. Concentrations of acenaphthylene, anthracene, fluoranthene, benzo(a)anthracene, benzo(f)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene presented strong correlations to ${\Sigma}_{16}PAHs$. Principal component analysis discriminated entire samples into three groups by two principal components (PC1 and PC2) with 70% of data variations, in which industrial types were not of importance, but a dominance of certain PAHs. Samples in group-I, which is high PC1 and low PC2, were characterized by a dominance of 2-ring PAHs, and in group-II, PC1 and PC2 showed a linear relation, was dominant 4-ring PAHs. Group-III with low PC1 and high PC2 includes 17 samples showing a noticeably high contribution of 3-ring PAHs to ${\Sigma}_{16}PAHs$. This study provides concentrations of PAHs in industrial sludges collected from a wide variety of sources (six industrial types) and two seasons of sampling events, and the comparison of ${\Sigma}_{16}PAHs$ with other studies are also discussed.

The SOFA Score to Evaluate Organ Failure and Prognosis in the Intensive Care Unit Patients (중환자실에 입원한 환자의 장기부전 및 예후 평가를 위한 SOFA 점수체계의 의의)

  • Kim, Su Ho;Lee, Myung Goo;Park, Sang Myeon;Park, Young Bum;Jang, Seung Hun;Kim, Cheol Hong;Jeon, Man Jo;Shin, Tae Rim;Eom, Kwang Seok;Hyun, In-Gyu;Jung, Ki-Suck;Lee, Seung-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.4
    • /
    • pp.329-335
    • /
    • 2004
  • Background : The Sequential Organ Failure Assessment (SOFA) score can help to assess organ failure over time and is useful to evaluate morbidity. The aim of this study is to evaluate the performance of SOFA score as a descriptor of multiple organ failure in critically ill patients in a local unit hospital, and to compare with APACHE III scoring system. Methods : This study was carried out prospectively. A total of ninety one patients were included who admitted to the medical intensive care unit (ICU) in Chuncheon Sacred Heart Hospital from May 1 through June 30, 2000. We excluded patients with a length of stay in the ICU less than 2 days following scheduled procedure, admissions for ECG monitoring, other department and patients transferred to other hospital. The SOFA score and APACHE III score were calculated on admission and then consecutively every 24 hours until ICU discharge. Results : The ICU mortality rate was 20%. The non-survivors had a higher SOFA score within 24 hours after admission. The number of organ failure was associated with increased mortality. The evaluation of a subgroup of 74 patients who stayed in the ICU for at least 48 hours showed that survivors and non-survivors followed a different course. In this subgroup, the total SOFA score increased in 81% of the non-survivors but in only 21% of the survivors. Conversely, the total SOFA score decreased in 48% of the survivors compared with 6% of the non-survivors. The non-survivors also had a higher APACHE III score within 24 hours and there was a correlation between SOFA score and APACHE III score. Conclusion : The SOFA score is a simple, but effective method to assess organ failure and to predict mortality in critically ill patients. Regular and repeated scoring enables patient's condition and clinical course to be monitored and better understood. The SOFA score well correlates with APACHE III score.

Study of Dynamic Variation Aspect in Lung Volume due to Respiration in Stereotactic Body Radiotherapy Using Abdominal Compressor (복부압박장치를 이용한 정위적방사선치료 시 호흡에 따른 폐암 용적의 동적변이 양상에 대한 연구)

  • Park, Kwang Soon;Kim, Joo Ho;Park, Hyo Kook;Beak, Jong Geal;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.159-165
    • /
    • 2013
  • Purpose: Abdominal compressor is used to control breathing in stereotactic body radiotherapy for lung tumors frequently. We evaluated the dynamic variation aspect of internal tumor volume by breathing. Materials and Methods: We reviewed 20 lung cancer patients (7 upper lung patients, 4 middle lung patients, 9 lower lung patients) who received stereotactic body radiotherapy using abdominal compressor between April 2012 to April 2013. Coordinate shift values were obtained by using four-dimensional cone-beam CT (4D-CBCT) to investigate treatment set-up error and moving tumor position error. To investigate how much difference of each part, we compared 95% confidence interval, maximum values and minimum values of three-dimensional vector value and analyzed conformity degree through the Pearson square correlation coefficient. Results: 95% confidence interval of three-dimensional vector value of each part is 1.8~2.9 mm in upper lobe, 2.3~5.4 mm in middle lobe and 2.2~4.0 mm in lower lobe. Conformity degree was the result that respectively is LR direction 0.75, SI direction 0.68 and AP direction 0.63 in upper lobe, LR direction 0.82, SI direction 0.51 and AP direction 0.92 in middle lobe and LR direction 0.63, SI direction 0.50 and AP direction 0.34 in lower lobe. Conclusion: We showed difference by each site in lung tumor due to respiration by using abdominal compressor. Therefore, we must correct treatment set-up error as well as moving tumor position error by breathing. It is also considered to be useful that it is the use of 4D-CBCT when correcting the error due to various dynamic variation.

  • PDF

Distributional Characteristics of Escherichia coli and Water Pollution in Gwangyang Bay and Jinhae Bay, Korea (광양만과 진해만에서 대장균 Escherichia coli분포와 수질오염 특성)

  • Son, Moon-Ho;Baek, Seung-Ho;Joo, Hae-Mi;Jang, Pung-Guk;Kim, Young-Ok
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.3
    • /
    • pp.162-170
    • /
    • 2011
  • In order to assess the inorganic and organic pollutents characteristics in marine water, we investigated COD (Chemical Oxygen Demand), Chlorophyll a and Escherichia coli during four seasons at 20 stations of Gwangyang Bay and at 23 stations of Jinhae Bay, Korea. The bay is divided into three zones in Gwangyang and four zones in Jinhae respectively, based on the pollutent levels. In Gwangyang Bay, the high concentration (mean 4.7 mg $L^{-1)$) of COD was recorded during spring season at Zone I, which can be characterized as a semi-enclosed eutrophic area (St. 1~9). Also, Chl. a concentrations were high at Zone I (mean 14.0 ${\mu}g\;L^{-1}$). The colony of E. coli were detected during summer season at Zone II, which is influenced by Seomjin River water. The E. coli may have been entered from the river water in a large pulse during rainy season. On the other hand, E. coli was kept low levels during four seasons at the Zone III, which is influenced indirectly by surface water currents from offshore of the bay. In Jinhae Bay, the high COD and Chl. a were shown during all seasons at Zone I, which is characteristed by semi-enclosed eutrophic area of Masan and Haengam bays. The Zone I also had been shown relatively high E. coli concentration in all seasons. In constrast, other three zones did not show seasonal characteristics of the E. coli concentrations. The present study suggests that E. coli concentrations can be significantly elevated in eutrophic semi-enclosed area.

Heart Rate Variability and Parenting Stress Index in Children with Attention-Deficit/Hyperactivity Disorder (주의력결핍 과잉행동장애 아동에서의 심박 변이도와 양육 스트레스)

  • Kim, Soo-Young;Lee, Moon-Soo;Yang, Jae-Won;Jung, In-Kwa
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.19 no.2
    • /
    • pp.74-82
    • /
    • 2011
  • Objective:The aim of this study was to evaluate the relationship between sustained attention deficits in Attention-Deficit/Hyperactivity Disorder(ADHD) children and short-term Heart Rate Variability(HRV) parameters. In addition, we evaluate the relationship between The ADHD rating scale(ARS), the computerized ADHD diagnostic system(ADS) and Parenting stress index- short form(PSI-SF). Methods:This study was performed in the department of children and Adolescent psychiatry, Korea university Guro hospital from august 2008 to January 2009. We evaluated HRV parameters by short-term recordings of 5 minutes. K-ARS and ADS are used for screening and identifying ADHD children. Intelligence was measured using Korean educational Developmental Institute-wechsler Intelligence Scale for Children. The caregivers Complete Parenting Stress Index scale for evaluation parent stress. Results:The low frequency(LF) was significantly correlated with response variability of ADS. However, the other variables of ARS and ADS were not significantly correlated with LF. Hyperactivity subscale of ARS was significantly correlated with parental distress subscale and difficult child subscale of PSI-SF and inattention subscale of ARS was also significantly correlated with dysfunctional interaction and difficult child subscale of PSI-SF. Conclusion:The LF, 0.10-Hz component of HRV is known to measure effort allocation. This study shows that the LF component of HRV is significantly correlated with the response variability of ADS. This means that more severe symptoms of ADHD were correlated with the increase in the LF that means decreased effort allocation. These results also support the clinical usability of HRV in the assessment of ADHD. Furthermore, PSI-SF is correlated with hyperactivity and inattention variables of ARS.

  • PDF

Effect of Hollow Glass Powder on the Self-Compacting Concrete (유공 유리분말이 자기충전 콘크리트의 특성에 미치는 영향)

  • Yoon, Seob;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.2
    • /
    • pp.141-149
    • /
    • 2018
  • In this study, compacting, passing performance, segregation resistance and rheological properties were tested to improve the stability of fresh concrete in the production and construction of self-compacting concrete (SCC) using hollow glass powder(GB). As a result, T50 reaching time was shortened up to amount of GB $2.0kg/m^3$. The compacting according to the amount of GB was improved by ball bearing effect of GB. However, T50 reaching time was slightly increased at $4.0kg/m^3$. In the case of passing performance, the result showed that plain was Class 1, GB $0.5{\sim}2.0kg/m^3$ was Class 0, GB $4.0kg/m^3$ was Class 1. Therefore, the passing performance was improved with 'No blocking' up to amount of GB $2.0kg/m^3$. Passing performance Block step (PJ) number by J-ring method was also best at GB $1.0kg/m^3$. In the case of segregation resistance according to the amount of GB, dynamic segregation resistance was increased compared to plain regardless of the amount of GB. And static segregation resistance showed 2.5% of segregation rate at GB $1.0kg/m^3$. Therefore, it was greatly improved compared to plain (12.5%). In the case of rheology property according to the amount of GB, plastic consistency by increasing of GB content didn't show big difference. However, yield stress by increasing of GB content was decreased with GB $1.0kg/m^3$. In conclusion, GB $1.0kg/m^3$ was effective for improvement of compacting, passing performance and yield stress. Also, it will be useful for stability of SCC by improving segregation.