• Title/Summary/Keyword: $Y_2O_3$ additive

Search Result 528, Processing Time 0.031 seconds

Determination of Liquid Paraffins in Foods by Using GC-FID (GC-FID를 이용한 식품 중 유동파라핀 함량 분석)

  • Park, Se-Jong;Choi, Jae-Chun;Lim, Ho-Soo;Jang, Su-Jin;Kim, So-Hee;Kim, Meehye
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.545-549
    • /
    • 2013
  • Liquid paraffin is a mixture of heavier alkanes derived from petroleum. It can be used as a lubricant in processing machinery, as a coating agent, or as a releasing agent. The purpose of this study was to analyze liquid paraffins in foods by using a gas chromatography-flame ionized detector (GC-FID). Liquid paraffin was extracted from the food samples using n-hexane. Non-polar aromatic or olefinic co-extractives were removed by alkaline permanganate oxidation followed by clean up on an aluminium oxide SPE cartridge before the GC-FID analysis. The results of recovery tests were 91.5-103.2%. Based on this optimized method, we investigated the amount of liquid paraffin in various food samples purchased from domestic markets. The levels of liquid paraffin in bread were $95.5{\pm}156.0$ mg/kg (0.008%), those in capsules were $40.2{\pm}54.5$ mg/kg (0.001%), and those in dried fruits and vegetables were $3.0{\pm}18.1$ mg/kg (0.0001%). No liquid paraffin was detected in fresh fruits and vegetables. We propose that our method can be used to monitor and detect liquid paraffin in foods for food safety management.

Index Cases in Pediatric Surgery - a National Survey by the Korean Association of Pediatric Surgeons, 2000 - (소아외과의 지수 질환 - 대한소아외과학회 정회원을 대상으로 한 2000년도 전국 조사 -)

  • Lee, M.D.;Kim, S.Y.;Kim, W.K.;Kim, I.K.;Kim, S.C.;Kim, S.K.;Kim, J.E.;Kim, J.C.;Kim, H.H.;Park, K.W.;Park, W.H.;Seo, J.M.;Song, Y.T.;Oh, S.M.;Yoo, S.Y.;Lee, D.S.;Lee, S.K.;Lee, S.C.;Chung, S.Y.;Chung, S.U.;Jung., E.S.;Jung, P.M.;Cho, M.H.
    • Advances in pediatric surgery
    • /
    • v.7 no.2
    • /
    • pp.147-156
    • /
    • 2001
  • Membership qualifications and recognition of the subspecialty training programs by the Korean Association of Pediatric Surgeons(KAPS) have been determined by criteria based on the number of neonatal and total pediatric surgical cases registered, since 1989 (Index cases). The numbers are based on a survey of the 14 founding members of the society by Jung et al. in 1987. The current survey is to review the present status of the index cases from 1997 to 1999 among 36 members of the KAPS. Two surveys were undertaken for this study. In the first survey, cases were collected by the registration form, composed of neonatal(N), important pediatric surgical cases (I), tumor and other similar operations(T) and other common pediatric surgical cases(O). Thirty members responded. and the result was discussed at the Topic Discussion section of the 15th Annual Congress of KAPS, 2000. The second survey analyzed additive data, proposed during discussion at the Congress. Twenty-three members responded. This report is the analysis of the both surveys. The average numbers of the cases/year/surgeon of N, I, T, O and total were 19.5, 51.8, 9.5, 77.1 and 356.5. respectively. The number of index cases(N+I+T)/year/surgeon was 80.8. The ratio of (N+I+T)/total cases was 0.3. Seventeen of 30 members have more than 20 cases of N per year. Twelve members have more than 150 cases, and 13 do more than 100 cases of I per year. Fourteen members have more than 10 cases of T per year. Nineteen and 10 members experienced more than 150 and 100 of index cases(N+I+T) per year. A new list of the index cases and coding system are proposed for the future regular update.

  • PDF

Study on the Analytical Method and Monitoring of the Oxidized Polyethylene Wax in Foods (식품 중 oxidized polyethylene wax 분석법 연구 및 함유량 실태 조사)

  • Choi, Seung-Hyun;Kim, Jae-Min;Choi, Sun-il;Jung, Tae-Dong;Cho, Bong-Yeon;Lee, Jin-Ha;Lee, Gunyoung;Lim, Ho Soo;Yun, Sang Soon;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.284-289
    • /
    • 2017
  • Oxidized polyethylene wax (OPEW) is, one of the food additives, used as a coating agent in citrus fruits and nuts. OPEW is authorized to quantum satis in EU, USA, and is acceptable less than 250 mg/kg in Australia and New Zealand. But OPEW is unauthorized as a food additive in Korea. This study was to establish the analytical method of OPEW and demonstrate the effective application of various food samples. We first conducted to compare the various analytical method including acid value (AV), high temperature gel permeation chromatography (HT-GPC), matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF/MS), gas chromatography flame ionization detector (GC-FID) and fourier transform infrared spectroscopy (FT-IR). This result indicated that FT-IR spectrum of OPEW treated food sample displayed absorption bands for carbonyl group (C=O, $1714cm^{-1}$), ester group (C-O, $1463cm^{-1}$), aliphatic group (C-H, $2916cm^{-1}$). Furthermore, IR spectrum of OPEW treated food sample showed similar tendency with IR spectrum of OPEW standard. Therefore, it is confirmed that analytical method using FT-IR can be detected on analysis of OPEW in food. As a result of monitoring of 111 samples using established analytical method, OPEW was not detected in the food samples.

Comparison of Feed Efficiency Between Rotifers Enriched Lipid-contents to Enrichment and Enhanced Digestive Enzymes Activity to Starch (영양강화 Rotifer와 효소활성 향상 Rotifer의 먹이효율 비교)

  • Kwon, O-Nam;Park, Heum-Gi
    • Journal of Aquaculture
    • /
    • v.22 no.1
    • /
    • pp.105-111
    • /
    • 2009
  • In this study, we carried out an experiment for estimation the larval digestibility in aspects which digestive enzymatic activities and nutrition of the rotifers, Brachionus rotundiformis. Thus we enhanced the digestive enzymatic activity through the addition of starch for the increase of digestibility of rotifer (starch-rotifer), and compared with the feed efficiency through rearing of the olive flounder, Paralichthys olivaceus used rotifer lipid-enriched with Algamac $2000^{(R)}$ (CE-rotifer). The digestive enzyme activities (except for TG-lipase), total protein contents, total essential amino acid, essential amino acids (methionin and phenylalanine) of starch-rotifer (the rotifer used a starch as additive, and enriched not) was assayed significantly higher than CE-rotifer (P<0.05). And total lipid, lipid classes (except for sterol) and fatty acids as DHA and EPA showed higher in CE-rotifer than starch-rotifer (P<0.05). But, sterol contents and ST/TG ratio were shown significantly higher in starch-rotifer (P<0.05). The flounder larvae supplied the two rotifers showed standard length and body weight that not significantly differed with ranges $3.72{\sim}3.79\;mm$ and $32.9{\sim}37.8\;mg$/larva on 6 days after hatching (DAH), respectively (P>0.05). However, these of 12 DAH showed the values of significantly higher to $5.94{\pm}0.249\;mm$, $144.0{\pm}23.86\;mg$/larva and $26.2{\pm}12.13%$ in standard length, body weight and survival in CE-flounder than that of starch-flounder (P<0.05). The hydrolytic enzymatic activities of flounder larvae severally supplied the two rotifers showed the significantly higher activities in acidic -amylase, neutral -amylase, TG-lipase, lysozyme and acidic phosphatase in starch-flounder on 5 DAH (P<0.05). But neutral $\alpha$-amylase, three proteases and two phosphatases of CE-flounder on 11 DAH showed the significantly higher activities than that of starch-flounder (P<0.05). Therefore, for the flounder, Paralichthys olivaceus larvae just depleted yolk was more beneficial to supply the feed, rotifer, enhanced the digestibility than to supply the feed lipid-enriched for aspect of larval digestibility up to 6 DAH, thereafter nutrition of absorption due to the development of digestive organs suggested that enrichment effect appeared with larval somatic growth. Consequently, investigation more detailed about the larval digestive physiological and nutritional requirement variations after 6 DAH will be necessary, thereafter.

QTL Mapping for 6-Year-Old Growths of a Single Open-Pollinated Half-Sib Family of a Selected Clone 7-1037 in Loblolly Pine(Pinus taeda) and Average Effect of QTL Allele Substitution (테다소나무 7-1037 클론의 단일 반형매 풍매가계 6년생 생장에 대한 QTL mapping과 QTL 대립유전자 치환의 평균효과)

  • Kim, Yong-Yul;Lee, Bong-Choon;O'Malley, David M.
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.4
    • /
    • pp.483-494
    • /
    • 2006
  • We conducted QTL mapping for 6-year growths of open-pollinated half-sib progenies from a selected clone 7-1037 in Pinus taeda. With an AFLP marker analysis on haploid DNA samples from the megagametophytes of the open-pollinated seeds, we constructed 20 framework maps spanning a total of 1,869 cM in total length and 18.5 cM in an average interval length between markers. Composite interval mapping reveals that one QTL explains 5.9% of the total phenotypic variation of height, and three QTLs account for 3.9~5.6% of the variation of diameter at breast height (DBH). There are no correlations between the QTLs. The genetic effects of the QTLs are 39.6 cm in height and 7.20~9.41 mm in DBH, respectively, The average effects of gene substitution of the markers closely linked with the QTLs are 44.3 cm in height and 8.38~11.81 m in DBH. Under an assumption that the within-family heritability for the growth traits of loblolly pine is less than 0.2, the QTLs account for 26.8% of the additive genetic variance of the progenies. In terms of relative selection efficiency, the individual selection based on QTL markers could be 5 times as high as phenotypic selection. The results in this study indicate that the QTL mapping method with open-pollinated half-sib family could be more practical and applicable to the conventional seed orchard-based selection work than other mapping methods with a single full-sib family, in particular from the viewpoint that it can provide crucial information for within-family individual selection such as breeding value.

Nuclear Imaging Evaluation of Galactosylation of Chitosan (핵의학 영상을 이용한 chitosan의 galactosylation 효과에 대한 평가)

  • Jeong, Hwan-Jeong;Kim, Eun-Mi;Park, In-Kyu;Cho, Chong-Su;Kim, Chang-Guhn;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.253-258
    • /
    • 2004
  • Purpose: Chitosan has been studied as a non-viral gene delivery vector, drug delivery carrier, metal chelator, food additive, and radiopharmaceutical, among other things. Recently, galactose-graft chitosan was studied as a non-viral gene and drug delivery vector to target hepatocytes. The aim of this study was to investigate the usefulness of nuclear imaging for in vivo evaluation of targeting the hepatocyte by galactose grafting. Methods and Materials: Galactosyl methylated chitosan (GMC) was produced by methylation to lactobionic acid coupled chitosan. Cytotoxicity of $^{99m}Tc$-GMC was determined by MTT assay. Rabbits were injected via their auricular vein with $^{99m}Tc$-GMC and $^{99m}Tc$-methylated chitosan (MC), the latter of which does not contain a galactose group, and images were acquired with a gamma camera equipped with a parallel hole collimator. The composition of the galactose group in galactosylated chitosan (GC), as well as the tri-, di-, or mono-methylation of GMC, was confirmed by NMR spectroscopy. Results: The results of MTT assay indicated that $^{99m}Tc$-GMC was non-toxic. $^{99m}Tc$-GMC specifically accumulated in the liver within 10 minutes of injection and maintained high hepatic uptake. In contrast, $^{99m}Tc$-MC showed faint liver uptake. $^{99m}Tc$-GMC scintigraphy of rabbits showed that the galactose ligand principally targeted the liver while the chitosan functionalities led to excretion through the urinary system. Conclusion: Bioconjugation with a specific ligand endows some degree of targetability to an administered molecule or drug, as in the case of galactose for hepatocyte in vivo, and evaluating said targetabililty is a clear example of the great benefit proffered by nuclear imaging.

Analysis of the Effects of Some Meteorological Factors on the Yield Components of Rice (수도 수량구성요소에 미치는 기상영향의 해석적 연구)

  • Seok-Hong Park
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.18
    • /
    • pp.54-87
    • /
    • 1975
  • The effects of various weather factors on yield components of rice, year variation of yield components within regions, and regional differences of yield components within year were investigated at three Crop Experiment Stations O.R.D., Suweon, Iri, Milyang, and at nine provincial Offices of Rural Development for eight years from 1966 to 1973 for the purpose of providing information required in improving cultural practices and predicting the yield level of rice. The experimental results analyzed by standard partial regression analysis are summarized as follows: 1. When rice was grown in ordinary seasonal culture the number of panicles greatly affected rice yield compared to other yield components. However, when rice was seeded in ordinary season and transplanted late, and transplanted in ordinary season in the northern area the ratio of ripening was closely related to the rice yield. 2. The number of panicles showed the greatest year variation when the Jinheung variety was grown in the northern area. The ripening ratio or 1, 000 grain weight also greatly varied due to years. However, the number of spikelets per unit area showed the greatest effects on yield of the Tongil variety. 2. Regional variation of yield components was classified into five groups; 1) Vegetation dependable type (V), 2) Partial vegetation dependable type (P), 3) Medium type (M), 4) Partial ripening dependable type (P.R), and 5) Ripening dependable type (R). In general, the number of kernel of rice in the southern area showed the greatest partial regression coefficient among yield components. However, in the mid-northern part of country the ripening ratio was one of the component!; affecting rice yield most. 4. A multivariate equation was obtained for both normal planting and late planting by log-transforming from the multiplication of each component of four yield components to additive fashion. It revealed that a more accurate yield could be estimated from the above equation in both cases of ordinary seasonal culture and late transplanting. 5. A highly positive correlation coefficient was obtained between the number of tillers from 20 days after transplanting and the number of panicles at each(tillering) stage 20 days after transplanting in normal planting and late planting methods. 6. A close relationship was found between the number of panicles and weather factors 21 to 30 days, after transplanting. 7. The average temperature 31 to 40 days after transplanting was greatly responsible for the maximum number of tillers while the number of duration of sunshine hours per day 11 to 30 days after transplantation was responsible for that character. The effect of water temperature was negligible. 8. No reasonable prediction for number of panicles was calculated from using either number of tillers or climatic factors. The number of panicles could early be estimated formulating a multiple equation using number of tillers 20 days after transplantation and maximum temperature, temperature range and duration of sunshine for the period of 20 days from 20 to 40 days after transplantation. 9. The effects of maximum temperature and day length 25 to 34 days before heading, on kernel number per panicle, were great in the mid-northern area. However, the minimum temperature and day length greatly affected the kernel number per panicle in the southern area. The maximum temperature had a negative relationship with the kernel number per panicle in the southern area. 10. The maximum temperature was highly responsible for an increased ripening ratio. On the other hand, the minimum temperature at pre-heading and early ripening stages showed an adverse effect on ripening ratio. 11. The 1, 000 grain weight was greatly affected by the maximum temperature during pre- or mid-ripening stage and was negatively associated with the minimum temperature over the entire ripening period.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF