• Title/Summary/Keyword: $V_2I$

Search Result 5,343, Processing Time 0.034 seconds

Flow Through Rubble Mound Dike (사석제를 투과하는 흐름)

  • 김채수;남선우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.4
    • /
    • pp.109-116
    • /
    • 1988
  • This study was aimed at determining a regime of flow through rubble mound dike consisted of all sized quarrystons, and deriving a relationship between hydraulic gradient (I) and mean flow velocity (V) through the dike. The analysis was carried out with the data observed after final gap closing of the Haenam Sea dike from May, 6 to May, 14, 1987. The resu]ts are summarized as follows: 1. The regime of flow would be defined as the turbulent flow. 2. As to the relationships, two kinds of formula that are exponential and binomial were obtained. Exponential formula: I=2.099V 1.2888 Binomial formula: I=0.6113V+5.5235V$^2$ 3. Correlation coefficient of the former was 0.824 and that of the latter was 0.821, and the deviations between observed data and estimated were 0.0070 and 0.0064 respectively. 4. Comparing the correlation coefficient, both the equations have the same correlation coefficients, but in case of the deviation the binomial equation was better than the exponential equation. Therefore, the binomial equation is proposed for analyzing the flow through rubble mound dike.

  • PDF

Design of AC/DC Combined V2X System for Small Electric Vehicle (소형 전기차 적용을 위한 AC/DC 복합 V2X 시스템 설계)

  • Kim, Yeong-Jung;Chang, Young-Hag;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.617-624
    • /
    • 2022
  • The small electric vehicles equipped with V2X(vehicle to everything) systems may provide more information and function to the existing navigation system of the vehicle. The key components of V2X technology include V2V (vehicle to vehicle), V2N(vehicle to network) and V2I (vehicle to infrastructure). This study is to design and implementation of VI type E-PTO which is interfaced with external equipments, the work designs the components of E-PTO such as DC/DC converter, DC/AC converter, battery bidirectional charging system etc. Also, it implements the devices and control systems for driving. The test results of VI type E-PTO components showed allowable 10% requirements of transient voltage variation rate and recovery time within 100ms for start/stop and normal operation.

The Fabrication of ZnO UV Photodetector with p-type Inversion Layer and Analysis of Vrlph Properties (P형 반전층을 갖는 ZnO 자외선 수광소자의 제작과 Vrlph특성 분석)

  • Oh, Sang-Hyun;Kim, Deok-Kyu;Park, Choon-Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.883-888
    • /
    • 2007
  • Investigation of improving the properties of UV detector which uses the wide bandgap of ZnO are under active progress. The present study focused on the design and fabrication of i-ZnO/p-inversion $layer/n^--Si$ Epi. which is characterized with very thin p-type inversion layer for UV detectors. The i-ZnO thin film for achieving p-inversion layer which was grown by RF sputtering at $450^{\circ}C$ and then annealed at $400^{\circ}C$ in $O_2$ gas for 20 min shows good intrinsic properties. High (0002) peak intensity of the i-ZnO film is shown on XRD spectrum and it is confirmed by XPS analysis that the ratio of Zn : O of the i-ZnO film is nearly 1 : 1. Measurement shows high transmission of 79.5 % in UV range (< 400 nm) for the i-ZnO film. Measurement of $V_r-I_{ph}$ shows high UV photo-current of 1.2 mA under the reverse bias of 30 V.

BRAINSTEM EVOKED RESPONSE AUDIOMETRY: LATENCY AND THRESHOLD IN NORMAL NEONATES (정상 신생아의 뇌간전위유발청각검사-전달 시간 및 역치)

  • 심윤주;김희남;김영명;차몽철;현승재;김경수
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1987.05a
    • /
    • pp.9.1-9
    • /
    • 1987
  • 뇌간유발청력검사는 최근 들어 신생아 및 영유아에 있어 청력 및 청신경로의 성숙(auditory maturation)정도를 파악할 수 있는 객관적인 진단 방법으로 평가되고 있다. 그러나 상기 검사결과는 측정계기의 종류 및 측정방법에 따라 다소 차이를 보일 수 있다. 우리나라에서는 아직 정상 신생아를 대상으로 뇌간유발청력검사에 대한 보고가 없는 실정이다. 이에 본 교실에서는 87년 3~4월에 Severance병원에서 출생한 정상 신생아 20명을 대상으로, 출생 후 16내지 69 시간내 두 차례에 걸쳐 뇌간유발 전달시간 및 뇌간유발 역치를 측정, 다음과 같은 결과를 얻었기에 보고하는 바이다. 1) 72.5 ㏈, 4KHz click에 대한 평균 절대적 latency는 각각 I(1.68), II(2.74), III(4.33), IV(5.71), V(6.77), Ⅵ(8.16), Ⅶ(9.85)였고 tone pip은 각각 I(2.04), II(3.04), III(4.60), IV(5.75), V(7.14), Ⅵ(8.54), Ⅶ(10.60) 이었다. 2) 평균 뇌간전위 유발역치는 29.5㏈ SPL 이었다. 3) 파형은 A형이 1.7%, 3형이 30.2%, C형이 45.7%, D형이 5.2%, E형이 1.7%, F형이 15.5%이었고, click과 tone pip, 자극음의 강도, ISI에 따른 차이가 없었다. 4) 제1소파에서 제5소파까지의 절대적 latency와 I- III, III-V,및 I-V의 상대적 latency에 있어서, 반복율, 자극음 종류 및 첫째날과 둘째날의 비교치에 있어서만이 선택적으로 유의한 차이가 발생하였으며, 자극음의 크기에는 차이가 나타나지 않았다.

  • PDF

I-V Characteristics of Epitaxial $CoSi_2$-contacted p+/n Junctions (Epitaxial $CoSi_2$접촉 p+/n 접합의 I-V 특성)

  • 구본철;김시중;김주연;배규식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.11
    • /
    • pp.908-913
    • /
    • 2000
  • CoSi$_2$/p+/n diodes(bilayer diodes) were fabricated by using epitaxial CoSi$_2$grown from Co/Ti bilayer as a diffusion source. The I-V characteristics of p+/n diodes were measured and compared with those of diode made from Co monolayer (monolayer diode). Monolayer diodes showed typical p+n junction characteristics with the leakage current of as low as 10$^{-12}$ A and forward current 6-orders higher than the leakage current, when drive-in annealed at 90$0^{\circ}C$ for 20 sec.. On the other hand, bilayer diodes showed the Schottky-like behaviors with forward currents rather higher than those of monolyer diodes, but with too high leakage currents, when drive-in annealed at $700^{\circ}C$ or higher. However, when the annealing temperature was lowered to $700^{\circ}C$ and annealing time was increased to 60 sec., the leakage current was reduced to 10$^{-11}$ A and thus sho3wed typical diode characteristics. The high leakage currents for diodes annealed at $700^{\circ}C$ or higher was attributed to Shannon contacts formed due to unremoved Co-Ti-Si precipitates. But when annealed at 50$0^{\circ}C$, B ions diffused in the direction of the surface layer, and thus the leakage currents were reduced by removing Shannon contacts.

  • PDF

A study and analysis of WiBro for infrastructure-vehicle communication technology (인프라-차량단말간 통신기술을 위한 WiBro 기술 분석 및 연구)

  • Lim, Il-kwon;Choi, Sang-wook;Kim, Young-hyuk;Choi, Jeong-Dan;Lee, Jea-kwang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.120-123
    • /
    • 2009
  • The WiBro to start June 2006 is mobile internet service with 60km/h, 3Mbps. And current WiBro service is used in Seoul, the metropolitan area and the local major cities. This study suggests WiBro technology and analyzes wireless communication technology to vehicle-to-infrastructure communications for the unmanned vehicle control. We were driving vehicle with two laptop computer's WiBro unit for V2I communication environment. So each RAS(Radio Access Station) on center is tested coverage area, transmission rate, latency rate, lost rate and transmission rate to parking area environment.

  • PDF

Calcium Current in the Unfertilized Egg of the Hamster

  • Haan, Jae-Hee;Cho, Soo-Wan;Yang, Young-Sun;Park, Young-Geun;Park, Hong-Gi;Chang, Gyeong-Jae;Kim, Yang-Mi;Park, Choon-Ok;Hong, Seong-Geun
    • The Korean Journal of Physiology
    • /
    • v.28 no.2
    • /
    • pp.215-224
    • /
    • 1994
  • The presence of a calcium current $(i_{Ca^{2+}})$ passed via a specific channel was examined in the unfertilized hamster egg using the whole-cell voltage clamp technique. Pure inward current was isolated using a $Ca^{2+}-rich$ pipette solution containing 10 mM TEA. This current was independent of external $Na^+$ and was highly sensitive to the $Ca^{2+}$ concentration in the bathing solution, indicating that the inward current is carried by $Ca^{2+}$. The maximal amplitude was $-4.12{\pm}0.58nA\;(n=12)$ with 10mM $Ca^{2+}$ at -3OmV from a holding potential of -8OmV. This current reached its maximum within 20ms beyond -3OmV and decayed rapidly with an inactivation time constant $({\tau})$ of 15ms. Activation and inactivation of this $i_{Ca^{2+}}$ was steeply dependent on the membrane potential. The $i_{Ca^{2+}}$ began to activate at the lower voltage of -55 mV and reached its peak at -35 mV, being completely inactivated at potentials more positive than -40 mV. These result suggest that $i_{Ca^{2+}}$ in hamster eggs passes through channels with electrical properties similar to low voltage-activated T-type channels. Other results from the present study support this suggestion; First, the inhibitory effect of $Ni^{2+}\;(IC_{50}=13.7\;{\mu}M)$ was more potent than $Cd^{2+}\;(IC_{50}=123\;{\mu}M)$. Second, $Ba^{2+}$ conductance was equal to or below that of $Ca^{2+}$. Third, $i_{Ca^{2+}}$ in hamster eggs was relatively insensitive to nifedipine $(IC_{50}=96.6\;{\mu}M)$, known to be a specific t-type blocker. The physiological role of $i_{Ca^{2+}}$ in the unfertilized hamster eggs remains unclear. Analysis from steady-state inactivation activation curves reveals that only a small amount of this current will pass in the voltage range $(-70{\sim}-30\;mV)$ which partially overlaps with the resting membrane potential. This current has the property that it can be easily activated by a weak depolarization, thus it may trigger a certain kind of a intracellular event following fertilization which may cause oscillations in the membrane potential.

  • PDF

Inhibition of K+ outward currents by linopirdine in the cochlear outer hair cells of circling mice within the first postnatal week

  • Kang, Shin Wook;Ahn, Ji Woong;Ahn, Seung Cheol
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.21 no.2
    • /
    • pp.251-257
    • /
    • 2017
  • Inhibition of $K^+$ outward currents by linopirdine in the outer hair cells (OHCs) of circling mice (homozygous (cir/cir) mice), an animal model for human deafness (DFNB6 type), was investigated using a whole cell patch clamp technique. Littermate heterozygous (+/cir) and ICR mice of the same age (postnatal day (P) 0 -P6) were used as controls. Voltage steps from -100 mV to 40 mV elicited small inward currents (-100 mV~-70 mV) and slow rising $K^+$ outward currents (-60 mV~40 mV) which activated near -50 mV in all OHCs tested. Linopirdine, a known blocker of $K^+$ currents activated at negative potentials ($I_{K,n}$), did cause inhibition at varying degree (severe, moderate, mild) in $K^+$ outward currents of heterozygous (+/cir) or homozygous (cir/cir) mice OHCs in the concentration range between 1 and $100{\mu}m$, while it was apparent only in one ICR mice OHC out of nine OHCs at $100{\mu}m$. Although the half inhibition concentrations in heterozygous (+/cir) or homozygous (cir/cir) mice OHCs were close to those reported in $I_{K,n}$, biophysical and pharmacological properties of $K^+$ outward currents, such as the activation close to -50 mV, small inward currents evoked by hyperpolarizing steps and TEA sensitivity, were not in line with $I_{K,n}$ reported in other tissues. Our results show that the delayed rectifier type $K^+$ outward currents, which are not similar to $I_{K,n}$ with respect to biophysical and pharmacological properties, are inhibited by linopirdine in the developing (P0~P6) homozygous (cir/cir) or heterozygous (+/cir) mice OHCs.

Phenanthrene Derivatives, 3,5-Dimethoxyphenanthrene-2,7-diol and Batatasin-I, as Non-Polar Standard Marker Compounds for Dioscorea Rhizoma

  • Yoon, Kee-Dong;Yang, Min-Hye;Nam, Sang-Il;Park, Ju-Hyun;Kim, Young-Choong;Kim, Jin-Woong
    • Natural Product Sciences
    • /
    • v.13 no.4
    • /
    • pp.378-383
    • /
    • 2007
  • Phenathrene derivatives, such as batatasins, are well-known constituents in Dioscorea Rhizoma. Although phenanthrenes have been reported as representative compounds in this plant, standard markers for quality control have been focused on the polar constituents (saponins and purine derivatives). Herein, simple, rapid and reliable HPLC method was developed to determine 3,5-dimethoxyphenanthrene-2,7-diol (DMP) and batatasin-I (BA-I) as non-polar standard maker compounds of Dioscorea Rhizoma. DMP and BA-I were analyzed under optimized HPLC conditions [column: Columbus $5{\mu}$ C18 100A ($30{\times}4.6mm$ i.d., $5{\mu}m$; mobile phase: $H_2O$ with 0.025% $CH_3COOH$ (v/v) for solvent A and $CH_3CN$ with 0.025% $CH_3COOH$ (v/v) for solvent B, gradient elution; flow rate: 2 mL/min; detection: 260 nm), and each experiment was finished within 13 min. Good linearity was achieved in the range from 0.5 to $10.0{\mu}g/mL$ for each compound, and intra- and inter-day precision were in the acceptable levels. The recovery test were performed with three different Dioscorea Rhizoma samples (D. opposita, D. batatas and D. japonica), and showed its accuracy values in the range of 97.2 - 102.8% for three different concentrations of DMP and BA-I. The content levels of DMP and BA-I were ranged under 0.0020%. These results demonstrated that amounts of DMP and BA-I are easily determined with conventional HPLC-UV-DAD method although the content levels were lower than those of saponins and allantoin in Dioscorea Rhizoma. This HPLC method could be used for quality control of various Dioscorea preparations.

A Study on the Application of PbI2 Dosimetry for QA in the Electron Beam Therapy (전자선 치료의 선량 측정 QA를 위한 PbI2 선량계 적용 연구)

  • Yang, Seungwoo;Han, Moojae;Jung, Jaehoon;Choi, Yunseon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.517-522
    • /
    • 2020
  • Electron beam have many factors that affect dose distribution, so even if identical settings are used, they should be identified and used for radiation treatment, and the effects on the structures in the body are sensitive, making it difficult to investigate uniform dose distribution on tumors. In this study, a dosimeter was produced using PbI2 which is a photoelectric material, and electrical characteristics were analyzed for 6, 9, and 12 MeV electronics in linear accelerators. The reproducibility test results showed that RSD were 1.1215%, 1.0160%, and 0.05137% respectively at 6, 9, and 12 MeV energies, indicating that the output signals were stable. The linearity evaluation results showed that the R2 values of the reliability indicator for straight line trend lines were 0.9999, 0.9999, and 0.9994, respectively, at 6, 9, and 12 MeV, to confirm that the output signal was proportional to PbI2 as dose increased. The PbI2 dosimeter in this study is judged to be highly applicable to electromagnet measurement and is thought to be able to be used as a basic study of electron detector through photoelectric material.