• 제목/요약/키워드: $V_2I$

검색결과 5,337건 처리시간 0.034초

정의적 영역 중심의 고등학교 환경 교재 개발 (Development of An Instructional material for High School Environmental Education Emphasizing Affective Objectives)

  • 박진희;장남기
    • 한국환경교육학회지:환경교육
    • /
    • 제6권1호
    • /
    • pp.63-99
    • /
    • 1994
  • The international environmental activities and environmental education began in 1970's. Environmental education in Korea was emphasized since the Forth National Curriculum. 'The Environmental Education Curriculum' will be separated as one of the most important parts in the Sixth National Education Curriculum in Korea. The purpose of this study was development. of 'Environmental Science' of high school appropriate to Sixth National Education Curriculum. First step was to state goals of environmental education in detail based on analysis of goals about environmental education in our country and other countries. Second was to analyse seven environments-related texts of Korea, America and England. Third, to measure how much environmental education has achieved in Fifth National Curriculum of Korea. Fourth, to develop a new environmental text of high school level. Fifth, to verify the effect of developed environmental text. The environmental part of 'Science I'(unit V. Life and Environments) and high school environments-related reference text(Survival and Environments) in Korea, American knowledges. American 'Environments' was stressed in many skills but they didn't include various teaching strategies. On the other hand, American 'Science-Technology-Society(S-T-S)' and British 'Science and Technology in Society(SATIS)' were stressed in knowledges and skills, and they included many teaching strategies and student actions. American 'S-T-S' was the only one stressed in values and attitudes. And all seven texts were not interested in behaviors and participations. To measure the achievement of environmental education by questionnaire, 497 high school students in total were selected from five different schools. Actually, most students had a positive thinkings and attitudes in their hearts about environmental problems, about environmental problems, but many of them did not take actions to solve environmental problems and to protect environments. The higher the score students got in 'knowledges and informations', the higher the score in 'skill'. It implies that learning of skills is based on learning of knowledges and informations about environments. On the other hand, much knowledges and information about environments has not always ensured positive thinkings and attitudes or active behaviors and participations to solve environmental problem. In view that ultimate aim of environmental education is forming responsible environmental behaviors and the goals of values and behaviors are as important as knowledges and skills. A new environmental text of high school level was developed and it was based on analysis of seven texts and environmental education in Fifth Korean Curriculum. This text have seven units, 1. Habitates : What're the meanings?, 2. Nuclear Energy : Can't be Avoid?, 3. Acid Rain : What're the Messages?, 4. Ethanol : Is this Future Fuel?, 5. Wastes : A New War!, 6. What're the National and Gloval Environmental education and avoided from the array of knowledges. Therefore included various teaching strategies and independent actions of students. 'Open-ended value learning' and 'free behavior learning' in text were special learning parts for aquisition of values and formation of behaviors. To verify the effects. of new developed environmental text, the direct learning was carried out by 286 students in total. Post test scores of experimental groups per each units were significantly higher than those of control groups from five different schools were as follows. For validity of selecting contents for units, 74% of respondent replied positively. For classification and presentation of four goal-groups, 90% replied positively in validity and 82%, in utility. For validity of various teaching strategies, 88% and for the degree of including student-centered independent actions, 86% replied positively, For importances and expected effects of 'open=ended value learning' and 'free behavior learning', showed positive responses respectively, 88%, 92% Therefore this text is effective to achieve four goals of environmental education equally.

  • PDF

우상 이언진의 비점본 「해람편」 연구 (Study on the Bijombon Haerampeon Written by Eonjin Lee)

  • 강순애
    • 한국기록관리학회지
    • /
    • 제7권1호
    • /
    • pp.83-109
    • /
    • 2007
  • 이 글은 새로 발굴된 우상 이언진의 비점본 "해람편(海覽篇)"을 중심으로 연구하였다. 내용의 전개는 우상(虞裳) 이언진의 생애(生涯), 우상(虞裳) 이언진의 유고(遺稿)와 문집(文集), "해람편(海覽篇)", 비점본(批點本) "해람편(海覽篇)"의 비점자(批點者) 이용휴(李用休)와 남옥(南玉), 비점본(批點本) "해람편(海覽篇)"과 "송목관집(松穆館集)" "송목관신여고(松穆館燼餘稿)"의 "해람편(海覽篇)" 비교의 순서로 살펴보았다. 이언진은 영조 16년(1740)~영조 42년(1766) 사이의 인물로 역관사가(譯官四家)로 알려진 시인이자 역관이다. 우상의 유고는 유일한 필첩인 "우상잉복(虞裳剩馥)"뿐이며 "우상잉복(虞裳剩馥)"에는 이용휴(李用休)와 남옥(南玉)이 비점을 찍은 "해람편(海覽篇)"과 일본 사행시의 일기 6편, 시 3편, 편지 5편이 실려 있다. 그중 비점본 "해람편(海覽篇)"은 영조40년(1764) 5월28일부터 6월8일 사이에 일기도(壹岐島) 선상에서 기술된 오언시(五言詩)이다. 이 시에는 이언진이 영조 39년(1763) 10월 6일부터 영조 40년(1764) 6월 20일까지 통신사 조엄을 수행하고 한학역관으로 일본에 파견되어 그곳에 머무르는 동안 보고 느낀 것이 생생하게 기술되어 있다. 이용휴와 남옥은 "해람편(海覽篇)"에 각각 청비(靑批) 청관주(淸貫珠) 및 주비(朱批) 주관주(朱貫珠)를 찍어서 해람편의 가치를 높이고 있다. "해람편(海覽篇)"은 네 단계로 구성되어 있다. 제1단계는 일본의 지리적인 위치와 그 풍물에 대한 것을, 제2단계는 대판(大阪)의 발전된 도시의 모습과 문명개화를 통해 운집한 세계의 물산(物産)들을, 제3단계는 일본인의 편향적인 민족성과 종교 및 서민들의 모습을, 제4단계는 일본과의 선린을 묘사하였다. 마지막장에는 비점본 "해람편(海覽篇)"과 "송목관집(松穆館集)" 및 "송목관신여고(松穆館燼餘稿)"에 실린 "해람편(海覽篇)"의 텍스트를 대교하고 그 차이점을 비교함으로써, 비점본 "해람편(海覽篇)"의 본문이 가장 정확하고 문화재로서의 가치가 있음을 밝혔다. 이 논문의 연구결과는 이언진의 연구는 물론 서지학계, 국어학계, 역사학계에 가장 기본적인 연구 성과로 활용될 것이다.

COVID-19에 대한 운동중재효과 분석 (Analysis of Physical Status on COVID-19: Based on Impacts of Physical Activity)

  • 김귀백;곽이섭
    • 생명과학회지
    • /
    • 제31권6호
    • /
    • pp.603-608
    • /
    • 2021
  • 본 연구는 COVID-19과 COVID-19 변이 바이러스 시기에 vaccination을 통한 집단면역달성을 목표로 하고 있지만, 백신의 종류에 따라서 다양한 부작용도 발생을 하여, 백신 이외에 평소 규칙적인 운동을 통한 백신 효과의 조그만 근거를 마련하고자 수행하게 되었다. 이러한 연구 연구목적을 달성하기 위해 본론에서는 COVID-19 vaccine의 이슈, COVID-19 블루, COVID-19과 스포츠이벤트, 및 COVID-19과 운동중재에 관해 분석하였다. 본 연구결과 COVID-19은 혈관을 우선적으로 공격하고 혈관 내막에 침투해 혈액순환을 방해하는 바이러스로 알려져 있다. 그리고 이어서 폐, 심장, 뇌 등을 공격한다. 심혈관 질환이 있는 환자들은 몸에서 바이러스를 몰아내는 능력이 떨어져 있는 이유로 이러한 바이러스의 공격대상이 될 수 있다. 혈관은 적혈구와 영양소만 이동하는 곳이 아니라 백혈구와 림프구들도 이동하므로 평소 불포화 지방산, 저탄수화물 식이요법을 포함하는 건강한 식이 습관, 금연, 일상생활도의 증가 및 규칙적인 운동 습관의 중요성이 중요하게 고려되어 진다. 이러한 관점에서 평소 혈관의 건강은 매우 중요하게 작용하고 이는 규칙적인 운동을 통하여 얻을 수 있는 것이다. 규칙적인 운동은 면역세포들, 면역글로불린, 다양한 사이토카인들의 순환을 돕고 특히, 폐로의 순환을 도와 염증인자들을 감소시키는 역할을 수행하고 병원균의 유입을 막아주는 역할을 한다. 특히, 혈관 내막에 침투해 혈액순환을 방해하는 것으로 알려져 있으며 폐, 심장, 뇌 등을 공격하는 COVID-19의 특성을 고려할 때 운동을 통한 건강관리는 바이러스 예방에 필수적이라고 할 수 있다. 현재 다양하고도 많은 백신의 사용은 팬데믹 시기에서 매우 희망적이지만 아나플락시스나 혈전 색전증 등의 다양한 부작용도 초래하므로 규칙적인 운동중재는 백신의 도움없이 세균이나 바이러스로부터 나를 지키는 면역력을 잘 유지하게 하는 것이 규칙적인 운동이 되는 것이다. 추후 이러한 분야에 관한 심도 있는 연구들이 수행되어져야 할 것으로 여겨진다.

광중합형 및 자가중합형 교정용 전색제의 치아우식예방 및 진행억제효과에 관한 실험적 연구 (The effects of fluoride releasing orthodontic sealants on the prevention and the progressive inhibition of enamel demiheralization in vitro)

  • 채승원;;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제27권6호
    • /
    • pp.979-995
    • /
    • 1997
  • 고정성 교정장치 주변에 발생되는 백색반점은 임상적으로 쉽게 눈에 띄는 문제점을 가지고 있으므로 잔치제거 후 심니적으로 만족스럽지 못한 결과를 야기하는데, 이는 곧 교정치료의 실패를 의미한다. 이미 많은 연구를 통해 고정성 교정장치가 구강내 세균환경을 변화시켜 세균집단의 증식을 용이하게 함으로써 고정성 장치 부착 후, 법랑질 탈회의 발생빈도가 증가된다는 사실이 보고 되어 왔으며 장기간이 소요되는 교정치료의 특성으로 인해 발생되는 브라켓 또는 교정용 밴드 주변의 법랑질 탈회나 치아우식증을 예방 또는 억제시키기 위한 연구가 함께 진행되어 왔다. 이는 환자에 대한 구강위생 교육이나 치아관리 노력에도 불구하고 발생될 수 있는데 이를 예방하기 위한 방법의 하나로 불소가 유리되는 교정용 전색제를 사용할 수 있다. 본 연구는 불소가 유리되는 광중합형 및 자가중합형 교정용 전색제의 치아우식 예방 및 진행억제효과를 규명하기 위해 다음과 같이 각각 7개의 편광현미경군(A군-G군)과 주사전자현미경군(A'군-G'군)으로 분류하였고 [1. A & A'군 STPP 인공우식용액에 담그지 않은 정상치아군, 2. B & B'군 : STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기 에 72시간 보관한 비처치군,3. C & C'군 : STPP 인공우식용액에 담그고 $37^{\circ}C$ 의 항온용기에 72시간 보관한 자가중합형 교정용 전색제군, 4. D &D'군 : STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 광중합형 교정용 전색제군, 5. E & E'군 표면에 아무처리 없이 STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 후, 이를 다시 아무런 처치없이 STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 비처치군, 6. F & F'군 : 표면에 아무런 처치없이 STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 후, 자가중합형 교정용 전색제를 도포하고 이를 다시 STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 자가중합형 교정용 전색제, 7. G & G'군 :표면에 아무런 처치없이 STPP 인공우식용액에 담그고 $37^{\circ}C$ 의 항온용기에 72시간 보관한 후, 광중합형 교정용 전색제를 도포하고 이를 다시 STPP 인공우식용액에 담그고 $37^{\circ}C$ 의 항온용기에 72시간 보관한 광중합형 교정용 전색제군], 이들을 편광현미경과 주사전자현미경을 이용해 조직의 변성 여부를 검색하여 다음과 같은 결과를 얻었다. 1. 편광현미경적 연구에서 인공우식병 소의 깊이는 $A군(5.08{\mu}m),\;B군(47.82{\mu}m,\;C군(8.42{\mu}m),\;D군(7.20{\mu}m),\;E군(85.41{\mu}m),\;F군(60.38{\mu}m),\;G군(60.13{\mu}m)$,이었다. 2. 인공우식 병소의 깊이에 있어서, B군은 A군,C군,D군과 비교하여 통계학적으로 유의성 있는 차이를 보였고(p<0.05), E군은 F군,G군과 비교하여 통계학적으로 유의성 있는 차이를 보였다(p<0.05). 3. 광중합형 및 자가중합형 교정용 전색제는 법랑질탈회 예방효과가 있었다. 4. 광중합형 및 자가중합형 교정용 전색제는 법랑질탈회 진행억제효과가 있었다. 5. 광중합형 및 자가중합형 교정용 전색제 표본에 대한 주사전자현미경적 연구에서 인공우식용액의 시간 경과에 따른 영향은 없었다. 6. 광중합형 교정용 전색제 표본과 자가중합형 교정용 전색제 표본 사이의 차이는 편광현미경과 주사전자현미경으로 구별할 수 없었다.

  • PDF

한국 청소년의 약물남용과 비행행위

  • 김성이
    • 한국인구학
    • /
    • 제11권2호
    • /
    • pp.54-66
    • /
    • 1988
  • I. Introduction Since the 1970's drug abuse among young people has increasingly become a social problem in Korea. In the 1980's, drug abuse, especially glue sniffing, has become the cause of many unfortunated incidents resulting in harm to others as well as the abusers themselves. Taking into consideration of the seriousness of this problem, the Republic of Korea National Red Cross initiated a nation-wide research programme, to understand the present situation and to raise the level of public awareness. The goal of this research was to begin a nation - wide campaign against drug abuse. The research team was composed of the Advisary Committee members and the staff of the Youth Department of the Republic of Korea National Red Cross. The data were collected in February 1988 with the collaboration of the staff and volunteers in the local Chapters. The respondents were allocated nation-wide by the quota sampling method. The questionnaires were distributed to the respondents in three groups :2, 700 to junior and senior high school students, 605 to working youths, and 916 to delinquent youths. A total of 4, 221 questionnaires were collected. II. Characteristics of the Respondents The respondents in each group were selected evenly from rural and urban areas. The general characteristics of the respondents can be described as follow: in case of students, the proportions between male and female respondents, and between senior high school and junior high school students were almost evenly distributed. In case of working youths, the proportion of females (80.5%) was higher than those of the students and the delinquents groups. Delinquent youths were defined as those currently being under custody of the centers for juvenile delinquents. Of this number, 38.8% and 68.2% were junior and senior high school drop-outs respectively. The majority of them (92.6%) were male. As for the family background of the respondents, the proportion of those residing in poverty - stricken areas, and the proportion of those from broken families were higher in case of working youths and delinquent youths than those in case of students. III. Present Patterns of Drug Abuse The following summarizes the presents of drug abuse, as tabulated from the results of the survey. 1. Smoking The percentage of youths who smoke was 36% in the student group, 32% m the working youths group, and 94.4% in the delinquent youths group. 2. Alcohol 50.3% of students, 71.6% of working youths, and 93.3% of delinquent youths has experienced drinking alcohol beverages. 3. Tonic: non - alcoholic, caffeinated beverages popular in Korea and Japan The percentage of those who have used tonic at least once was over 90% in all of the three groups. 4. Sedative About 70% of each group has used sedative with the proportion of working youths use higher than those in other groups. 5. Stimulants Those who have used stimulants comprised around 15% in each group. 6. Tranquilizers Somewhat less than 5% of students and working youths, and 28% of delinquent youths, have used tranquilizers. 7. Hypnotics The users of hypnotics amounted to 0.4% of students, 2.6% of working youths and 7.1% of delinquent youths. 8. Marihuana Those who have used marihuana indicated 0.7% of students, 0.8% of working youths, and 13% of delinquent youths. 9. Glue-sniffing The percentage of glue-sniffing was 3.7%, 5% in the students group and in the youths group respectively, but the proportion was unusually high, at 40.7% in the delinquent youths group. From the results of the survey the present situation of drug abuse in Korea can be summarized as follows: 1. A high percentage of Korean youths have experienced smoking cigarettes and drinking alcoholic beverages. 2. Tonics (non - alcoholic, caffeinated beverages), antipyretic analgesics and stimulants quite regularly used. 3. Tranquilizers, hypnotics, marihuana and glue-sniffing are more widely used among delinquent youths than the other youths. From this fact, there exists a correlation between drug abuse and juvenile delinquency. IV. Time-series Analysis of the First Experience of Drug Abuse and Deviant Behaviour The respoundents were asked when they were first exposed to drugs and when they committed deviant acts. By calculating the average age of each experience, the following pattern was found (See Figure 1). Youths are first exposed to drugs by abuse of tonic(non - alcoholic, caffeinated beverages). At the age of 13, they amoke cigarettes, the use of antipyretic analgesics begins at 14 year old, while at the age of 15, they use tranquilizers, and at 16 hynotics. The period of drug abuse which starts from drinking caffeinated beverages and smoking cigarettes and ends in the use of hypnotics takes about three years. During this period, other delinquent behaviours begin to surface, that is, at the age of 13 when smoking cigarettes begins, the delinquent behaviour pattern starts with truancy. Next, they start taking money from others by using physical force. Prior to the age of 15, they are suspended from school, become hostile to adults, begin running away from home, and start using stimulants and alcohol. Soon they become involved even in glue-sniffing and in the use of marihuana. At the age of 15, they begin to see adult videos and carry weapons. Sexual promiscuity and usage of tranquilizers follows the viewing of adult videos. Consequently, by the time they reach the age of 16, they visit drinking establishments, and are picked up by police for committing delinquent acts. And finally, they come to use hypnotic - type drugs. From the above descriptions, drug abuse can be assumed to have a close correlation with delinquent behaviour. V. Social Factors Related to Drug Abuse As for the Korean youths, glue-sniffing is found to he related to aggressive delinquency, in such cases as run - aways, being picked up by the police, and taking money by force. Smoking cigarettes and drinking alcohol is found to be related to seeing adult videos and visiting drinking establishments. Hypnotics and marihuana were found to be representive of drugs which are related to degenerational delinquency, irrespective of social delinquency. The social factors connected with these drug abuse are as follows: 1. Individual factors Male students were more heavily involved in the usage of drug than females. Youths who do not attend church were more likely to be involved in drugs than those who attend. 2. Family factors The youths who were displeased with their mothers smoking and those who thought their parents did not love each other, or those whose parents had used drugs without prescription, were more likely to he drug users. 3. School factors Those youths who found school life boring, were unsuccessful in their studies, spend most of their time with friends, feel their teachers smoke too much, those who had a positive perception of their teachers smoking were likely to he drug users. To sum up, drug abusers depend on the influence of their parents, teachers and peers. IV. Reasons for Drug Abuse Korean students have mainly used drugs to release stress (42.8%), to stay awake (19.7%), and because of the easy accessibility of drugs( 16.6%). Other reasons are due to their ignorance of the side effects of the drugs (3.6%), natural curiosity (4.2%), and to increase strength(3.O%). From the above facts, the major reasons for drug abuse among Korean youths are to release stress and to stay awake in order to prepare exams. Furthermore, since drugs are readily available, we can conclude that drug abuse is caused by the school system(such as entrance exams) in Korea. VII. Conclusion Drug usage among Korean youths are relatively less common than those of western youths. In some cases, such as, glue-sniffing and use of stimulants, the pattern of drug abuse is found. Moreover, early drug abuse is evident, and it has a close connection with deviant behaviour, resulting in juvenile delinquency. Drug abuse cannot be attributed to any one social factor. Specifically, drug abuse depends on parents, peers, teachers and other members of the community, and also is influenced by social institutions such as the entrance exam system. Every person and organization concerned with youth must participate collectively in restraining drug abuse. Finally, it is suggested that social agencial working for youth welfare should make every effort to tackle this serious problem confronted by the Korean youths today.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF