• Title/Summary/Keyword: $V_{140}$

Search Result 519, Processing Time 0.036 seconds

Investigation of the Effect of kV Combinations on Image Quality for Virtual Monochromatic Imaging Using Dual-Energy CT: A Phantom Study

  • Jeon, Pil-Hyun;Chung, Heejun;Kim, Daehong
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Background: In this study, we investigate the image quality of virtual monochromatic images synthesized from dual-energy computed tomography (DECT) at voltages of 80/140 kV and 100/140 kV. Materials and Methods: Virtual monochromatic images of a phantom are synthesized from DECT scans from 40 to 70 keV in steps of 1 keV under the two combinations of tube voltages. The dose allocation of dual-energy (DE) scan is 50% for both low- and high-energy tubes. The virtual monochromatic images are compared to single-energy (SE) images at the same radiation dose. In the DE images, noise is reduced using the 100/140 kV scan at the optimal monochromatic energy. Virtual monochromatic images are reconstructed from 40 to 70 keV in 1-keV increments and analyzed using two quality indexes: noise and contrast-to-noise ratio (CNR). Results and Discussion: The DE scan mode with the 100/140 kV protocol achieved a better maximum CNR compared to the 80/140 kV protocol for various materials, except for adipose and brain. Image noise is reduced with the 100/140 kV protocol. The CNR values of DE with the 100/140 kV protocol is similar to or higher than that of SE at 120 kV at the same radiation dose. Furthermore, the maximum CNR with the 100/140 kV protocol is similar to or higher than that of the SE scan at 120 kV. Conclusion: It was found that the CNR achieved with the 100/140 kV protocol was better than that with the 80/140 kV protocol at optimal monochromatic energies. Virtual monochromatic imaging using the 100/140 kV protocol could be considered for application in breast, brain, lung, liver, and bone CT in accordance with the CNR results.

Effect of Image quality and Radiation Dose using Iterative Reconstruction in Adult and Pediatric CT: A Phantom Study (성인과 소아 CT 촬영시 IR 적용에 따른 영상화질 및 선량에 미치는 영향)

  • Ju, A-ran;Jo, Jung-Hyun;Oh, Young-Kyu;Kim, Kyoung-Ki;Lee, Soo-Been;Jeon, Pil-Hyun;Kim, Daehong
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.1
    • /
    • pp.23-31
    • /
    • 2018
  • The main issue of CT is radiation dose reduction to patient. The purpose of this study was to estimate the image quality and dose by iterative reconstruction (IR) for adults and pediatrics. Adult and pediatric images of phantom were obtained with 120 and 140 kV, respectively, in accordance with radiation dose in terms of volume CT dose index ($CTDI_{vol}$): 10, 15, 20, 25, 30, 35 mGy. Then, the adult and the pediatric images are reconstructed by filtered-backprojection (FBP) and iterative reconstruction (IR). The images were analyzed by signal-to-noise ratio (SNR). SNR is improved when IR and 140 kV are applied to acquire adult and pediatric images. In the adult abdomen, according to diagnostic reference level, the SNR values of bone were increased about 27.84 % and 27.77 % at 120 kV and 140 kV, and the tissue's SNR values of the IR were increased about 29.84 % and 33.46 % 120 and 140 kV, respectively. Dose is reduced to 40% in adults abdomen images when using IR reconstruction. In pediatric images, the bone's SNR were also increased about 17.70% and 18.17 % at 120 kV and 140 kV. The tissue's SNR were increased about 26.73 % and 26.15 % at 120 kV and 140 kV. Radiation dose is reduced from 30% to 50% for bone and tissue images. In the case of examinations for adult and pediatric CT, IR technique reduces radiation dose to patient, and it could be applied to adult and pediatric imaging.

Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield (140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가)

  • Kim, Ji-Young;Lee, Wang-Hui;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.129-134
    • /
    • 2018
  • The present study made a phantom for gamma ray of 140 keV radiated from $^{99m}Tc$, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180 mm depths of the phantom, and when there was no shield, 0.2 mm lead shield, 0.5 mm lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5 mm lead shield. The shielding effect of 0.2 mm lead shielding was about 30.18% and the shielding effect of 0.5 mm lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0 mm depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10 mm in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.

Novel Bacterial Surface Display System Based on the Escherichia coli Protein MipA

  • Han, Mee-Jung
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.7
    • /
    • pp.1097-1103
    • /
    • 2020
  • Bacterial surface display systems have been developed for various applications in biotechnology and industry. Particularly, the discovery and design of anchoring motifs is highly important for the successful display of a target protein or peptide on the surface of bacteria. In this study, an efficient display system on Escherichia coli was developed using novel anchoring motifs designed from the E. coli mipA gene. Using the C-terminal fusion system of an industrial enzyme, Pseudomonas fluorescens lipase, six possible fusion sites, V140, V176, K179, V226, V232, and K234, which were truncated from the C-terminal end of the mipA gene (MV140, MV176, MV179, MV226, MV232, and MV234) were examined. The whole-cell lipase activities showed that MV140 was the best among the six anchoring motifs. Furthermore, the lipase activity obtained using MV140 as the anchoring motif was approximately 20-fold higher than that of the previous anchoring motifs FadL and OprF but slightly higher than that of YiaTR232. Western blotting and confocal microscopy further confirmed the localization of the fusion lipase displayed on the E. coli surface using the truncated MV140. Additionally the MV140 motif could be used for successfully displaying another industrial enzyme, α-amylase from Bacillus subtilis. These results showed that the fusion proteins using the MV140 motif had notably high enzyme activities and did not exert any adverse effects on either cell growth or outer membrane integrity. Thus, this study shows that MipA can be used as a novel anchoring motif for more efficient bacterial surface display in the biotechnological and industrial fields.

Fast Fabrication of Nanoporous Anodic Alumina Membrane by Hard Anodization (하드애노디제이션에 의한 나노다공질 양극산화 알루미나 멤브레인의 제조)

  • Ha, Yoon-Cheol;Jeong, Dae-Yeong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.429-429
    • /
    • 2009
  • Nanoporous anodic alumina membranes (NAAM) with high-density through-hole pores fabricated by hard anodization of aluminum in 0.3 M oxalic acid under the applied voltage of 40 (mild anodization), 80, 100, 120 and 140 V were investigated. The current-time responses monitored using a PC-controlled anodization cell and the corresponding pore structures attainable from field-enhanced scanning electron microscopy (FE-SEM) were analyzed in order to establish the optimum fabrication process. The nanoporous structure can be produced for all the voltage conditions, while the stabilized through-hole pore formation seems to occur at 40, 80 and 140 V. The growth rate under 140 V hard anodization was over 30 times higher than under 40 V mild anodization (1.5 um/hr).

  • PDF

Development of 140kV, 20mA Rated High Voltage Pulsed Power System for Pilot EP (140kV, 20mA급 Pilot 집진기용 고압 펄스 전원장치 개발)

  • Kim, Won-Ho;Kang, Iou-Ri;Lee, Kwang-Hak;Kim, Jong-Soo;Rim, Geun-Hie;Kim, Chul-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.2
    • /
    • pp.73-78
    • /
    • 2001
  • With the increasing demands for clean environment, development of air cleaning systems has been received increasing attention. One of the key technologies in the electrostatic precipitator(EP) is high voltage pulsed power supply, which affects the performance of the overall system. In this study, a high voltage microsecond pulse power supply for the pilot EP is developed. The power supply has a dc source and a pulsed one. The ratings of the dc and the pulse source are 60kV and 70kV respectively. The width of pulse voltage is 140us and the maximum pulse repetition frequency is 200Hz.

  • PDF

Output Characteristics of the PMS-PZT Piezoelectric Transformer Driving High Power Amplifier (PMS-PZT를 이용한 압전 변압기의 하이파워 시 출력 특성)

  • Kim, Dong-Soo;Kim, Young-Deog;Kim, Kwang-Il;Sohn, Joon-Ho;Nam, Hyo-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.830-833
    • /
    • 2004
  • Voltage step-down characteristics of Ring/Dot type piezoelectric transformer were examined with increasing input voltage from $10\;V_{pp}$ to $140V_{pp}$. Then the output load resistance was fixed to $125\;\Omega$. The voltage gain showed constant value till the input voltage of $70\;V_{pp}$. And then it linearly decreased till the input voltage of $140V_{pp}$. The output voltage of fabricated piezoelectric transformer increased with increasing input voltage. And driving frequencies when the output voltage was maximum value were changed according to input voltage. Frequency shifts and temperature rise of fabricated sample showed 2 kHz, $13^{\circ}C$, respectively when input voltage was changed from $10\;V_{pp}$ to $140V_{pp}$. Because of the temperature rise of fabricated piezoelectric transformer, the step-down characteristics of it was deteriorated above the input voltage of $70\;V_{pp}$.

  • PDF

The Application of the Measurement of Heart Rate and Velocity during Training to Assess Racing Performance in Thoroughbred Horses (더러브렛 경주마에서 운동능력 평가를 위한 훈련 중 심박수 및 속도측정 수치 활용방안 연구)

  • Lee, Young-woo;Hwang, Hye-shin;Song, Hee-eun;Shim, Seung-tae;Ko, Jeong-ja;Seo, Jong-pil;Lee, Kyoung-kap
    • Journal of Veterinary Clinics
    • /
    • v.36 no.1
    • /
    • pp.62-67
    • /
    • 2019
  • This study was performed to apply the measurement of heart rate and velocity in training horses for assessing race performance. Additionally, we aimed to identify parameters that can be used to evaluate the training level and exercise capacity. Eleven healthy 2- to 6-year-old Thoroughbreds were trained by the standard training program and heart rate and velocity were measured by using heart monitoring system and GPS. Regression analysis in heart rate and velocity data was performed to calculate velocity parameters. The mean maximal heart rate in gallop was $214{\pm}11bpm$. The mean $V_{140}$, $V_{180}$, $V_{200}$ and $VHR_{max}$ were $13.8{\pm}4.3km/h$, $37.5{\pm}3.8km/h$, $49.3{\pm}4.3km/h$ and $57.4{\pm}7.1km/h$ respectively. The mean $V_{140}$ of high performance racehorses was significantly higher than that of low performance racehorses (P < 0.05). Moreover, analyzing the correlation between velocity parameters and racing ability-related categories showed that $V_{140}$ was positively correlated with rating (P < 0.05), $V_{180}$ and $VHR_{max}$ were positively correlated with prize money per race (P < 0.05). Also, $V_{140}$ was significantly correlated with G1F (P < 0.05). The results of this study have shown that the measurement of heart rate and velocity during training could be useful methods to assess fitness for races or performance potential. Especially, $V_{140}$ is a good parameter to evaluate a performance of racehorses in Korea.

An Analysis of Exposure Dose on Hands of Radiation Workers using a Monte Carlo Simulation in Nuclear Medicine (몬테카를로 모의 모사를 이용한 핵의학과 방사선작업종사자의 손에 대한 피폭선량 분석)

  • Jang, Dong-Gun;Kang, Sesik;Kim, Junghoon;Kim, Changsoo
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.477-482
    • /
    • 2015
  • Workers in nuclear medicine have performed various tasks such as production, distribution, preparation and injection of radioisotope. This process could cause high radiation exposure to wokers' hand. The purpose of this study was to investigate shielding effect for r-rays of 140 and 511 keV by using Monte-carlo simulation. As a result, it was effective, regardless of lead thickness for radiation shielding in 140 keV r-ray. However, it was effective in shielding material with thickness of more than only 1.1 mm in 511keV r-ray. And also it doesn't effective in less than 1.1 mm due to secondary scatter ray and exposure dose was rather increased. Consequently, energy of radionuclide and thickness of shielding materials should be considered to reduce radiation exposure.

The comparisons of three scatter correction methods using Monte Carlo simulation (몬테카를로 시뮬레이션을 이용한 산란보정 방법들에 대한 비교)

  • 봉정균;김희중;이종두;권수일
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.73-81
    • /
    • 1999
  • Scatter correction for single photon emission computed tomography (SPECT) plays an important role to improve image quality and quantitation. The purpose of this study was to investigate three scatter correction methods using Monte Carlo simulation. Point source and Jaszack phantom filled with Tc-99m were simulated by Monte Carlo code, SIMIND. For scatter correction, we applied three methods, Compton window (CW) method, triple window (TW) method, and dual photopeak window (DPW) method. Point sources located at various depths along the center line within a 20-cm phantom were simulated to calculate the window ratios and corresponding scatter fractions by evaluating the polynomial coefficients for DPW method. Energy windows were located in W$_1$=92-125 keV, W$_2$=124-126 keV, W$_3$=136-140 keV, W$_4$=140-141 keV, and W$_{5}$=154-156 keV. The results showed that in Jaszack phantom with cold sphere and hot sphere, the TW gave the closest contrast and percentage recovery to the ideal image, respectively, while CW overestimated and DPW underestimated the contrast of ideal one. All three scatter correction methods showed an improved image contrast. In conclusion, scatter correction is essential for improving image contrast and accurate quantification. The choice of scatter correction method should be made on the basis of accuracies and ease of implementation.

  • PDF