A Study on the Swine Wastewater Treatment Using UV/TiO2/H2O2 (UV/TiO2/H2O2를 이용한 축산폐수처리에 대한 연구)

  • Kim, Chang-Kyun;Chung, Ho-Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3B
    • /
    • pp.321-327
    • /
    • 2006
  • This study was performed to provide basic information for evaluating the efficiency and applicable extent of photocatalysis for the treatment of swine wastewater. Acid area was more efficient than neutral and alkalic areas in wastewater treatment, and level of pH3 was the most effective and the treatment efficiency continually increased as the amount of photocatalyst was increased. When the photocatalyst was increased, $TCOD_{Mn}$ was removed faster than chromaticity. Pollutants were more effectively eliminated with both UV light illumination and $TiO_2$ than with either UV or $TiO_2$ alone. The removal efficiency was increased with the addition of $H_2O_2$ as an oxidant, but the removal efficiency was decreased with over an dosage of $H_2O_2$. The optimal dosage of $H_2O_2$ was 200 mg/L. Continuous injection of $H_2O_2$ was required for effective oxidation.

Comparative Studies Of the $UV/H_2O_2,\;UV/TiO_2/H_2O_2$ and Photo-Fenton Oxidation for Degradation of Citric Acid ($UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton 산화방법에 의한 Citric Acid의 분해효율 비교)

  • Seo, Min-Hye;Cho, Soon-Haing;Ha, Dong-Yun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.429-437
    • /
    • 2006
  • To establish the efficient treatment technology of chemical cleaning wastewater from power plant, several AOPs($UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation) were investigated. Treatment efficiencies and the electrical energy requirements based on the EE/O parameter(the electrical energy, required per order of pollutant removal in $1m^3$ wastewater) were evaluated. TOC removal efficiencies of $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation at the optimum conditions were 95.5%, 92.3%, 91.5%, respectively. The electrical energy requirements of $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation were $11.26kWh/m^3,\;3.85kWh/m^3,\;0.799kWh/m^3$, respectively. From these results, it could be concluded that all of the three oxidation processes were effective for the degradation of citric acid. Considering the treatment efficiency and economical aspect, photo-Fenton oxidation was the most efficient treatment process among the three processes tested.

Color and COD Removal of Rhodamine B Using Ozone, Photocatalyst and Ozone-Complex Process (오존, 광촉매 및 오존-복합 공정을 이용한 Rhodamine B의 색도와 COD 제거)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.662-669
    • /
    • 2007
  • The effect of advanced oxidation processes such as $O_3$, $UV/TiO_2$, $O_3/UV$ and $O_3/UV/TiO_2$ on decolorization and COD removal of Rhodamine B(RhB) wastewater were considered. The results showed that the higher the $O_3$ concentration was, the higher the decolorization observed and the optimum $TiO_2$ dosage was 0.4 g/L in $UV/TiO_2$ and $O_3/UV/TiO_2$ process. $O_3/UV$ process showed the higher initial decolorization rate constant and the shorter termination time for decolorization than those of the $O_3$ process. The decolorization rate constants in various systems followed the order of $O_3/UV/TiO_2>O_3/UV>O_3{\gg}UV/TiO_2$. The decolorization rate of the RhB solution in every processes was more rapid than the mineralization rate identified by COD removal. The latter took longer time for further oxidation. The COD removal rate constants in four systems followed the order of $O_3/UV/TiO_2>O_3/UV>UV/TiO_2{\geqq}O_3$. Among four processes, combined photocatalysis and ozonation$(O_3/UV/TiO_2)$ was the most prospective process for removing color and COD such as dye wastewater.

Characterization of Humic Acid in the Chemical Oxidation Technology(I) - Characteristics by Photocatalytic Oxidation Process - (화학적 산화법에 의한 부식산의 분해 처리기술에 관한 연구(I) - 광산화공정을 통한 부식산의 분해특성 분석 -)

  • Kim, Jong Boo;Rhee, Dong Seok
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.234-240
    • /
    • 2000
  • The efficiency of Photocatalytic Oxidation Process were investigated for the treatment of Aquatic Humic Substances (AHS). In UV-only system, pH 7-9 was the optimum pH range for TOC removal, and alkali range was the optimum pH for absorbance decrease. In UV/$TiO_2$ system, the optimum $TiO_2$ dosage was 50ppm and over 50ppm of $TiO_2$ dosage was not effective for removal of AHS. In UV/$H_2O_2$ system, optimum $H_2O_2$ dosage was 20mM, when over 20mM dosage, removal of TOC (Total Organic Carbon) and absorbance was decreased. Radical scavenger affected on the photo-oxidation of AHS. Removal rate of TOC and absorbance was decreased by addition of carbonate ions and TOC removal was more effected than that of absorbance.

  • PDF

Degradation of Dye Wastewater by Advanced Oxidation Process: A Comparative Study (고급산화공정에 의한 안료폐수 처리: 비교 연구)

  • Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.67-75
    • /
    • 2006
  • The degradation of Rhodamine B (RhB) in water was investigated in laboratory-scale experiments, using five advanced oxidation Processes (AOPs) $UV/H_2O_2$, lenten, photo-lenten, $UV/TiO_2,\;UV/TiO_2/H_2O_2$. The photodegradation experiments were carried out in a fluidized bed photoreactor equipped with an immersed 32 W UV-C lamp as light source. initial decolorization rate and COD removal efficiency were evaluated and compared. The results obtained showed that the initial decolorization rate constant was quite different for each oxidation process. The relative order of decolorization was: photo-fenton > $UV/TiO_2/H_2O_2$ > fenton > $UV/H_2O_2$ > $UV/TiO_2$ > UV > $H_2O_2$. The relative order of COD removal was different from decolorization: photo-fenten ${\fallingdotseq}$ $UV/TiO_2/H_2O_2\;>\;UV/TiO_2\;>\;fenton\;>\;UV/H_2O_2$. The Photo-lenten and $UV/TiO_2/H_2O_2$ processes seem to be appropriate for decolorization and COD removal of dye wastewater.

A Comparative Study on Degradation of BTEX Vapor by O3/UV, TiO2/UV, and O3/TiO2/UV System with Operating Conditions (운전조건에 따른 O3/UV, TiO2/UV 및 O3/TiO2/UV 시스템의 BTEX 증기처리에 관한 비교 연구)

  • Kim, Kyoung-Jin;Park, Ok-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.91-99
    • /
    • 2008
  • A multilayer tower-type photoreactor, in which $TiO_2$-coated glass-tubes were installed, was used to measure the vapor-phase BTEX removal efficiencies by ozone oxidation ($O_3$/UV), photocatalytic oxidation ($TiO_2$/UV) and the combination of ozone and photocatalytic oxidation ($O_3/TiO_2$/UV) process, respectively. The experiments were conducted under various relative humidities, temperatures, ozone concentrations, gas flow rates and BTEX concentrations. As a result, the BTEX removal efficiency and the oxidation rate by $O_3/TiO_2$/UV system were highest, compared to $O_3$/UV and $TiO_2$/UV system. The $O_3/TiO_2$/UV system accelerated the low oxidation rate of low-concentration organic compounds and removed organic compounds to a large extent in a fixed volume of reactor in a short time. Therefore, $O_3/TiO_2$/UV system as a superimposed oxidation technology was developed to efficiently and economically treat refractory VOCs. Also, this study demonstrated feasibility of a technology to scale up a photoreactor from lab-scale to pilot-scale, which uses (i) a separated light-source chamber and a light distribution system, (ii) catalyst fixing to glass-tube media, and (iii) unit connection in series and/or parallel. The experimental results from $O_3/TiO_2$/UV system showed that (i) the highest BTEX removal efficiencies were obtained under relative humidity ranging from 50 to 55% and temperature ranging from 40 to $50^{\circ}C$, and (ii) the removal efficiencies linearly increased with ozone dosage and decreased with gas flow rate. When applying Langmuir-Hinshelwood model to $TiO_2$/UV and $O_3/TiO_2$/UV system, reaction rate constant for $O_3/TiO_2$/UV system was larger than that for $TiO_2$/UV system, however, it was found that adsorption constant for $O_3/TiO_2$/UV system was smaller than that for $TiO_2$/UV system due to competitive adsorption between organics and ozone.

A Study on the Treatment of Dyeing Wastewater Using $TiO_2/H_2O_2/UV$ Processes ($TiO_2/H_2O_2/UV$ 공정을 이용한 염색폐수처리에 관한 연구)

  • 조일형;정효준;박경렬;성기석;이용규;이홍근
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.26-34
    • /
    • 2000
  • In order to treat the dyeing wastewater, the $UV/TiO_2/H_2O_2$ system was investigated, and proper pretreatment methods were examined to reduce the load on the system considering economical and technical efficiency. The results of this study were as follows: 1. $UV/TiO_2/H_2O_2$ system with pretreatment process was adopted, the result of Chemical coagulation and pH control units was $pH{\;}11{\;}{\rightarrow}{\;}coagulation{\;}{\rightarrow}{\;}pH{\;}4$ and the optimum dosage of $FeCl_3$ was $600mg/{\ell}$. 2. Proper dosage of $TiO_2$ in the $UV/TiO_2/H_2O_2$ system with pretreatment process was $2g/{\ell}$ and $H_2O_2$ was $1000mg/{\ell}$, UV contact time was 20min to get $200mg/{\ell}$ of $COD_{Cr}$.

  • PDF

Degradation of THM precursor using $TiO_2$ photocatalytic oxidation in the water treatment processes (정수처리공정에서 $TiO_2$광촉매를 이용한 THM전구물질 제거에 관한 연구)

  • Cho Deok-Hee;Seo Su-Man
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.2
    • /
    • pp.1-6
    • /
    • 2004
  • In Bok-Jeong water treatment plant, chlorination is the only technique used for disinfection of drinking water. This disinfecting treatment leads to the formation of trihalomethanes (THMs). This study was carried out to investigate the possibility of improving removal efficiency of THM precursor in the conventional water treatment processes by $TiO_2$ photocatalytic oxidation. Removal efficiencies of DOC, $UV_{254}$, THMFP were low in the conventional water treatment processes. With application of $TiO_2$ photocatalyst, DOC, $UV_{254}$, THMFP were reduced more effectively. As the $TiO_2$ photocatalytic reaction time increased, the removal efficiencies of DOC, $UV_{254}$, THMFP were increased. The $TiO_2$ photocatalytic removal efficiencies of DOC, $UV_{254}$, THMFP were increased with increasing $TiO_2$ dosage. However, over 0.6g/l of $TiO_2$ dosage, the efficiency reached a plateau.

The Removal of Humic Acid and Heavy Metals Using UV/TiO2/H2O2 (UV/TiO2/H2O2 공정을 이용한 휴믹산과 중금속 제거)

  • Kim, Jongoh;Jung, Jongtae;Choi, Wonyoul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.4
    • /
    • pp.5-13
    • /
    • 2006
  • This study was conducted to evaluate the application of $UV/TiO_2/H_2O_2$ process for treating humic acid and heavy metals in surface water. Removal efficiency of $UV/TiO_2/H_2O_2$ process was much more efficient than that of $UV/TiO_2$ process for humic acid and heavy metals removal. The removal rate of humic acid and heavy metals increased with the increase of $TiO_2$ dosage and UV intensity, however decreased with more than 0.3 g/L of $TiO_2$ dosage. The addition of $H_2O_2$ as an oxidant was a positive effect for the removal rate of humic acid and heavy metals especially in the concentration of 50 mg/L $H_2O_2$.

  • PDF

Organic Removal Efficiency and Toxicity Evaluation of Persistent Microorganism from Dye Wastewater Treatment using a Photooxidation system (광산화시스템을 이용한 염색폐수의 유기물 처리효율 및 잔류미생물의 독성 평가)

  • Jung, Ho Jun;Rhee, Dong Seok
    • Journal of Industrial Technology
    • /
    • v.29 no.A
    • /
    • pp.83-88
    • /
    • 2009
  • The removal efficiency of organic compounds and the toxicity evaluation of microorganism have been studied in dye wastewater treatment using $UV/TiO_2$ and $UV/H_2O_2$ photooxidation system. Sample waters tested in this work were raw dye wastewater and dye wastewater treated in $UV/TiO_2$ and $UV/H_2O_2$ photooxidation system respectively. Total organic carbon(TOC) removal rate was 50% in $UV/TiO_2$ process and 80% in $UV/H_2O_2$ process. It has been investigated with colony counting agar method and paper disk method whether the type of treatment process has affected the microorganism growth. In the raw wastewater, more than four types of microorganisms have survived. But, little of microorganisms were alive at TOC removal rate of 50% in $UV/TiO_2$ system. In contrast to that, two types of microorganisms were found at TOC removal rate of 80% in $UV/H_2O_2$ system.

  • PDF