• 제목/요약/키워드: $TcpCo_2$

Search Result 51, Processing Time 0.039 seconds

Analysis on the Effects of Traffic Control Program on the Air Quality in Seoul (자동차 부제에 의한 서울 대기오염 저감 효과 분석)

  • Lee, Hyung-Min;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.498-506
    • /
    • 2007
  • To reduce the vehicular emissions of air pollutants, various traffic control programs (TCPs) have been used. In 2002, two TCPs have been implemented in Seoul and Busan, respectively. In this study, based on the study results on the effectiveness of the TCP in Seoul (Kim et al., 2005) and Busan (Lee et al., 2006), emission reduction by the TCP in Seoul was estimated and their contribution to the ambient air pollutants' concentrations was discussed. During the TCP period in 2002 at Seoul, emissions of air pollutants were reduced by 35% for CO and $NO_2$, 80% for HC, 23% for $PM_{10}$, and 24% for $SO_2$. Vehicular emission reduction affected the ambient concentrations significantly for $NO_2$. However, for $SO_2$, vehicular emission reduction did not affect the ambient concentration significantly. For $PM_{10}$, vehicular emission reduction did not affect the ambient concentration significantly if considering fugitive emissions.

Suitability evaluation of magnesium substituted biphasic calcium phosphates prepared by coprecipitation method (공침법을 이용한 마그네슘이 첨가된 biphasic calcium phosphate의 적합성 평가)

  • Lee, Hyoung-Sin;Kim, Tae-Wan;Kim, Dong-Hyun;Park, Hong-Chae;Yoon, Seog-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.237-242
    • /
    • 2010
  • Magnesium-substituted BCP (biphasic calcium phosphate) powders were prepared by incorporating small amounts of magnesium into the structure of different hydroxyapatite (HAp)/${\beta}$-tricalcium phosphate (${\beta}$-TCP) ratios through coprecipitation method. A series of magnesium substitutions ranging from 0, 0.5, and 1.0 wt%, which are comparable to the measured magnesium contents, were performed. The obtained powders were characterized by the following analytical techniques: X-ray diffraction analysis (XRD), Thermo Gravimetric Analyzer (TGA) and Fourier transform infrared spectroscopy (FT-IR). The results have shown that substitution of magnesium in the calcium-deficient apatites resulted in the formation of biphasic mixtures of different HAP/${\beta}$-TCP ratios after heating above $1000^{\circ}C$. The 1.0 wt% magnesiumsubstituted-BCP were soaked in Hank's solutions after 2 weeks to observe the morphology of the biocement, especially needle-like hydroxyapatite crystals and to estimate the length and diameter of nanoneedle crystals.

Effect of Electron-beam Irradiaton on the Artificial Bone Substitutes Composed of Hydroxyapatite and Tricalcium Phosphate Mixtures with Type I Collagen (수산화인회석과 인산삼칼슘 및 1형 콜라젠 혼합골의 전자빔 조사 효과)

  • Park, Jung Min;Kim, Soung Min;Kim, Min Keun;Park, Young Wook;Myoung, Hoon;Lee, Byung Cheol;Lee, Jong Ho;Lee, Suk Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.1
    • /
    • pp.38-50
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the effect and potential of electron beam (E-beam) irradiation treatment to the synthetic bony mixtures composed of hydroxyapatite (HA; Bongros$^{(R)}$, Bio@ Co., Korea) and tricalcium phosphate (${\beta}$-TCP, Sigma-Aldrich Co., USA), mixed at various ratios and of type I collagen (Rat tail, BD Biosciences Co., Sweden) as an organic matrix. Methods: We used 1.0~2.0 MeV linear accelerator and 2.0 MeV superconductive linear accelerator (power 100 KW, pressure 115 kPa, temperature $-30{\sim}120^{\circ}C$, sensor sensitivity 0.1~1.2 mV/kPa, generating power sensitivity 44.75 mV/kPa, supply voltage $5{\pm}0.25$ V) with different irradiation dose, such as 1, 30 and 60 kGy. Structural changes in this synthetic bone material were studied in vitro, by scanning electron microscopy (SEM), elementary analysis and field emission scanning electron microscope (FE-SEM), attenuated total reflection (ATR), and electron spectroscopy for chemical analysis (ESCA). Results: The large particular size of HA was changed after E-beam irradiation, to which small particle of TCP was engaged with organic collagen components in SEM findings. Conclusion: The important new in vitro data to be applicable as the substitutes of artificial bone materials in dental and medical fields will be able to be summarized.

Safety and efficacy of fimasartan with essential hypertension patients in real world clinical practice: data from a post marketing surveillance in Korea

  • Han, Su-Eun;Jeong, Seung Hee;Kang, Hye Jeong;Hong, Myung Sook;Paek, Eunah;Cho, Hijung;Choe, Seong Choon
    • Translational and Clinical Pharmacology
    • /
    • v.26 no.3
    • /
    • pp.118-127
    • /
    • 2018
  • The safety and efficacy of fimasartan have been evaluated through post-marketing surveillance in real world clinical practice. The multi-center, prospective, open-label and non-interventional study. A total of 3,945 patients (3,729 patients for safety assessment and 3,473 patients for efficacy assessment) were screened in patients with essential hypertension in 89 study centers from 9 September 2010 through 8 September 2016. Among the total patients, 2,893 patients (77.6%) were administered fimasartan for 24 weeks or longer and were classified as 'patients with long-term follow-up', and the additional safety and efficacy analysis were performed. The improvement was defined as systolic blood pressure (SBP) controlled to ${\leq}140mmHg$ or decreased SBP differences ${\geq}20mmHg$ after treatment or diastolic blood pressure (DBP) controlled to ${\leq}90mmHg$ or decreased DBP differences ${\geq}10mmHg$ after treatment. Adverse drug reactions (ADRs) were reported in 3.8% patients; dizziness, and hypotension were the most frequently reported ADRs in total patients. The results of patients with long-term follow-up were comparable with total patients. The overall improvement rate in all efficacy assessment at the last visit was 87.1% (3,025/3,473 patients). The overall improvement rate of the patients with long-term follow-up was 88.9%. Fimasartan was well tolerated, with no new safety concerns identified and an effective treatment in the real world clinical practice for Korean patients with hypertension.

Design and Implementation of Interface Module between Network Framework for Sensor Network Application and Co-Simulator (센서네트워크 어플리케이션을 위한 네트워크 프레임워크와 통합시뮬레이터 간의 인터페이스 구현 및 설계)

  • Lee, Jeong-Joo;Koak, Dong-Eun;Seo, Min-Suk;Park, Hyun-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.515-524
    • /
    • 2013
  • For the development of reliable software, Software testing is the most important. Recently small changes of the software according to the importance of regression testing is growing. To verify Application of a large number of nodes, Network simulator environment is required. This paper proposed interface module between network framework for sensor network application and co-simulator to unit test sensor network application. To conclude, developer can focus on sensor network application implementation only, so the improved integrated simulator contributes to increase development productivity.

A Design of Dynamic Simulator of Articulated Robot (다관절 로봇의 동적 시뮬레이터 설계)

  • Park, In-Man;Jung, Seong-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.2
    • /
    • pp.75-81
    • /
    • 2015
  • This study proposes an articulated robot control system using an on/off-line robot graphic simulator with multiple networks. The proposed robot control system consists of a robot simulator using OpenGL, a robot controller based on a DSP(TMS320) motion board, and the server/client communication by multiple networks. Each client can control the real robot through a server and can compare the real robot motion with the virtual robot motion in the simulation. Also, all clients can check and analyze the robot motion simultaneously through the motion image and data of the real robot. In order to show the validity of the presented system, we present an experimental result for a 6-axis vertical articulated robot. The proposed robot control system is useful, especially, in the industrial fields using remote robot control as well as industrial production automation with many clients.

Multi Axis control system using Embedded Web Server (임베디드 웹 서버를 이용한 다축제어 시스템)

  • 김윤업;주형민;곽군평
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.775-778
    • /
    • 2002
  • In this paper, we've studied multi axis control system using embedded web server which is controlling and monitoring the state data of moors. NanoWit2 Board has been ported Linux Operating System and fabricated Web Sorrel by GCC. Motion controller is used MCS-40 of e-MOTION Tek Co., Ltd. which receiving control signal, controlling motors and sending the state data to Web Server.

  • PDF

Synergistic effect of phosphate solubilization by Burkholderia strains isolated from button mushroom bed (양송이배지로부터 분리한 Burkholderia균의 인산가용화 공조효과)

  • Park, Ji-Hoon;Han, Chang-Hoon;Yoon, Min-Ho
    • Journal of Mushroom
    • /
    • v.15 no.4
    • /
    • pp.183-189
    • /
    • 2017
  • This study investigated the synergistic effect of single inoculation and co-inoculation of phosphate-solubilizing bacteria (PSB) Burkholderia metallica JH-7 and Burkholderia contaminans JH-15. Phosphate-solubilizing abilities of these strains were assessed by measuring phosphorus content in culture media that were singly inoculated or co-inoculated with these strains for 7 days. B. metallica JH-7 was found to release the highest content of soluble phosphorus ($140.80{\mu}g\;mL^{-1}$ ) into the medium, followed by single inoculation of B. contaminans JH-15 ($135.95{\mu}g\;mL^{-1}$ ) and co-inoculation of two strains ($134.84{\mu}g\;mL^{-1}$ ). The highest pH reduction, organic acid production, and glucose consumption were observed in the medium inoculated with B. metallica JH-7 alone compared with that in the medium co-inoculated with both the strains. Results of a plant growth promotion bioassay showed 17.4% and 7.48% higher leaf and root growth, respectively, in romaine lettuce inoculated with B. metallica JH-7 alone than in romaine lettuce inoculated with a control strain. However, no significant difference was observed between single inoculation and co-inoculation of these strains with respect to phosphorus release and plant growth. Although the results of the present study did not show the synergistic effect of phosphate solubilization by the PSB strains examined, these results indicate that treatment with PSB exerts a beneficial effect on crop growth.

Effect of Cr/Ti/Al Elements on High Temperature Oxidation Behavior of a Ni-Based Superalloy with Thermal Exposure (고온 노출 니켈기 초내열합금 터빈 블레이드의 Cr/Ti/Al 성분이 고온 산화에 미치는 영향)

  • Byung Hak Choe;Sung Hee Han;Dae Hyun Kim;Jong Kee Ahn;Jae Hyun Lee;Kwang Soo Choi
    • Korean Journal of Materials Research
    • /
    • v.33 no.2
    • /
    • pp.77-86
    • /
    • 2023
  • High-temperature oxidation of a Ni-based superalloy was analyzed with samples taken from gas turbine blades, where the samples were heat-treated and thermally exposed. The effect of Cr/Ti/Al elements in the alloy on high temperature oxidation was investigated using an optical microscope, SEM/EDS, and TEM. A high-Cr/high-Ti oxide layer was formed on the blade surface under the heat-treated state considered to be the initial stage of high-temperature oxidation. In addition, a PFZ (γ' precipitate free zone) accompanied by Cr carbide of Cr23C6 and high Cr-Co phase as a kind of TCP precipitation was formed under the surface layer. Pits of several ㎛ depth containing high-Al content oxide was observed at the boundary between the oxide layer and PFZ. However, high temperature oxidation formed on the thermally exposed blade surface consisted of the following steps: ① Ti-oxide formation in the center of the oxide layer, ② Cr-oxide formation surrounding the inner oxide layer, and ③ Al-oxide formation in the pits directly under the Cr oxide layer. It is estimated that the Cr content of Ni-based superalloys improves the oxidation resistance of the alloy by forming dense oxide layer, but produced the σ or µ phase of TCP precipitation with the high-Cr component resulting in material brittleness.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.