Purpose: To classify and describe the characteristic features of MRI of some ameloblastoma variants. Materials and Methods: The MR images, CT images, and panoramic radiographs in 5 cases were retrospectively examined as follows. First, the contents of ameloblastomas were devided into two portions of either solid or cystic components on the basis of MR signal intensities. The signal intensity within the solid or cystic portions was classified as homogeneous or heterogeneous. Next, the characteristic internal feature of the lesion on T1W1 or T2WI was described. The signal intensities were classified into low, intermediate, slightly high, high, and strong high signal intensity. Results: Unicystic lesion showed homogeneous high signal intensity (SI) on T2W2 and the rim enhancement of the surrounding area including the mural nodule and the thick wall except the central portion on Gd- T1W1. Solid type revealed heterogeneous and high SI area with strong high SI area on T2W2. On Gd- T1W1, the area corresponding to the low signal spot on T1W1 and the strong high signal spot on T2W1 showed low SI. Hybrid type showed slightly enhanced capsular structures and low SI for the round bony septa and the areas connecting the mixed and cystic lesions on T2Wl and Gd-T1W1. Conclusion: MRI could easily assess the relationship between the mixed and cystic findings in ameloblastoma.
두개 창상에 의해 신경증상을 나타내는 4 마리의 환자가 내원하여 일반 방사선 검사 및 컴퓨터단층촬영술(CT)과 자기공명영상(MRI)을 실시하였다. 일반 방사선 사진에서는 내원한 4 마리의 개에서 모두 특이소견을 관찰할 수 없었다. 3마리 개에서 실시한 CT 결과, 3마리 중 2마리의 환자에서 전두엽 부위에 고밀도로 나타나는 병변을 확인할 수 있었으나 소뇌 부위의 병변은 관찰되지 않았다. 이어서 실시한 MRI 검사 결과, 일부의 환자에서는 T1-강조영상에서 저신호로 나타나고 T2-강조영상에서 고신호로 나타나거나 T1-강조영상과 T2-강조영상에서 각각 등신호, 고신호로 나타나는 병변을 확인할 수 있었다. 병변 부위는 좌측과 우측 대뇌 부위, 소뇌전정 부위, 경막하 부위로 다양했다. 이들 환자는 내과적 치료를 실시한 후, 임상적으로 호전되었음을 확인하고 일부 환자는 MRI를 통해 추적검사를 하였다.
Arachnoid cysts are intra-arachnoid collections of cerebrospinal fluid. They may cause neurological deficit through expansion that can compress normal neural tissue and obstruct cerebrospinal fluid flow. Intracranial arachnoid cysts were found in 4 patients aged 10 months to 20 months(mean age 15 months). The presenting symptoms included circling(dog 2,3), seizure(dog 1), progressive weakness(dog 1,2,3), increasing scoliosis(dog 3), worsening spasticity(dog 3), and salivation(dog 3). One patient showed no symptoms from the intracranial arachnoid cyst. There were no significant findings in complete blood count and serum chemistry. Computed tomography(CT) with/without magnetic resonance imaging(MRI) scans were performed in these cases. Hypodense intracranial arachnoid cyst was observed on CT images in dog 4. Sagittal T1-weighted(T1W) and T2-weighted(T2W) images and transverse T1W and T2W images revealed a intracranial arachnoid cysts with syringohydromyelia(dog 3) and hydrocephalus(dog 3,4) in the brain. Clinical signs of three cases were improved by medication.
Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.
Cystic lymphangioma is an uncommon benign developmental tumor of the lymphatic system, seen rarely in adults. A 23-year-old man visited DKUDH complaining of the painless swelling in the right submandibular area. It was reported that swelling had increased since 5 months ago. Clinically, fltriangle uctuant and mobile mass was palpated at the right submandibular area. CT scan showed a large, well-defined, homogenous low density mass, measuring 5.0 × 2.5 × 4.0 cm. T1W MRI scan demonstrated a large, multiseptated homogenous low signal mass with septum and rim enhancement. Proton-density and T2W MRI scan showed mass of high signal intensity. MRI scan was able to delineate better the enhanced multi septation and extent of the lesion. Histopathologically, a lobulated cystic mass lined by a layer of flattened endothelium was observed.
MR compatible coaxial-slot antenna for microwave hyperthermia was developed while its structure and size of each part were determined by computer simulation using finite element method(FEM). Its local heating performance was evaluated using tissue-mimic phantom and swine muscles. 2% agarose gel mixed with 6mM/$\ell$$MnCl_2$ as a biological tissue-mimic phantom was heated by the proposed antenna driven by a 2.45GHz microwave generator. The temperature changes of the phantom were monitored using multi-channel digital thermometer at the distance of 0mm, 5mm, 10mm and 20mm from the tip center of the antenna. Also muscle tissue of swine was heated for 2 and 5minutes with 50W and 30W of microwave generator powers, respectively, to evaluate the local heating performance of the antenna. MRI compatibility was also verified by acquiring MR images and MR temperature map. MR signals were acquired from the agarose gel phantom using $T2^*$ GRE sequence with 1.5T clinical MRI scanner(Signa Echospeed, GE, Milwaukee, WI, U.S.A.) at Pusan Paik Hospital and were transferred to PC in order to reconstruct MR images and temperature map using proton resonance frequency(PRF) method and laboratory-developed phase unwrapping algorithm. Authors found that it has no severe distortion due to the antenna inserted into the phantom. Finally, we can conclude that the suggested coaxial-slot antenna has an excellent local heating performance for both of tissue-mimic phantom and swine muscle, and it is compatible to 1.5T MRI scanner.
본 연구의 목적은 1.5 T와 3.0 T 비 인두 MRI 검사 후 SNR과 CNR을 평가하여 최적의 Tesla를 알아보고자 하였다. 총 30명의 PACS로 전송된 Nasopharynx MRI검사 환자를 무작위로 선택하여 본 연구에 적용하였다. 데이터 분석에 사용된 장비로는 1.5 T, 3.0 T MRI 장비를 이용하였다. 분석 방법으로 T1 WI과 T1 지방소거 영상에서 각 Tongue, Spinal Cord, Masseter Muscle, Fat, Parotid Gland, Tumor의 조직에 대하여 일정한 관심영역을 설정하고 SNR와 CNR을 평가하였다. 6가지의 조직에 대하여 정량적 분석으로 SNR과 CNR을 평가하였고, 정성적 분석으로 균일한 지방소거, 자화 감수성 인공물에 대한 영상의 질을 4점 척도로 측정하였다. 본 데이터 분석의 통계적 유의성은 독립표본 T검증과 Wilcoxon Signed Ranks사용하였으며, p 값이 0.05이하일 때 유의성을 두었다. 본 실험에 대한 정량적 평가 결과 T1 WI 과 T1 지방소거를 1.5 T와 3.0 T를 비교했을 때 T1 WI에 대한 3.0 T가 평균 SNR(124.75±), CNR(118.91±)로 정량적 분석에서 SNR과 CNR값이 1.5 T평균 SNR(73.15±), CNR(60.59±)에 비해 높게 나타났다. 또한 T1 지방소거에서 3.0 T가 평균 SNR(101.10±), CNR(81.24±)로 1.5 T의 평균 SNR(78.47±), CNR(65.70±)에 비해 높게 나타났다. 정성적 분석으로 균일한 지방소거, 자화 감수성 인공물에 대하여 4등급으로 평가했을 때 1.5 T 장비가 높은 점수를 얻었다(p<0.05). 결론적으로 두 기기에 대한 데이터 분석 결과 정량적 평가부분 에서는 3.0 T 장비가 높게 나타났고 정성적 평가 부분에서는 1.5 T가 높게 나타났다. 따라서 각 장비에 대한 장단점을 고려할 때 상호보완적으로 장비를 선택하여 환자에게 적용한다면 최적의 정보를 제공할 것이라고 사료된다.
Hae Young Kim;Seung Hyun Cho;Jong Keon Jang;Bohyun Kim;Chul-min Lee;Joon Seok Lim;Sung Kyoung Moon;Soon Nam Oh;Nieun Seo;Seong Ho Park
Korean Journal of Radiology
/
제25권4호
/
pp.351-362
/
2024
Objective: To measure inter-reader agreement and identify associated factors in interpreting complete response (CR) on magnetic resonance imaging (MRI) following chemoradiotherapy (CRT) for rectal cancer. Materials and Methods: This retrospective study involved 10 readers from seven hospitals with experience of 80-10210 cases, and 149 patients who underwent surgery after CRT for rectal cancer. Using MRI-based tumor regression grading (mrTRG) and methods employed in daily practice, the readers independently assessed mrTRG, CR on T2-weighted images (T2WI) denoted as mrCRT2W, and CR on all images including diffusion-weighted images (DWI) denoted as mrCRoverall. The readers described their interpretation patterns and how they utilized DWI. Inter-reader agreement was measured using multi-rater kappa, and associated factors were analyzed using multivariable regression. Correlation between sensitivity and specificity of each reader was analyzed using Spearman coefficient. Results: The mrCRT2W and mrCRoverall rates varied widely among the readers, ranging 18.8%-40.3% and 18.1%-34.9%, respectively. Nine readers used DWI as a supplement sequence, which modified interpretations on T2WI in 2.7% of cases (36/1341 [149 patients × 9 readers]) and mostly (33/36) changed mrCRT2W to non-mrCRoverall. The kappa values for mrTRG, mrCRT2W, and mrCRoverall were 0.56 (95% confidence interval: 0.49, 0.62), 0.55 (0.52, 0.57), and 0.54 (0.51, 0.57), respectively. No use of rectal gel, larger initial tumor size, and higher initial cT stage exhibited significant association with a higher interreader agreement for assessing mrCRoverall (P ≤ 0.042). Strong negative correlations were observed between the sensitivity and specificity of individual readers (coefficient, -0.718 to -0.963; P ≤ 0.019). Conclusion: Inter-reader agreement was moderate for assessing CR on post-CRT MRI. Readers' varying standards on MRI interpretation (i.e., threshold effect), along with the use of rectal gel, initial tumor size, and initial cT stage, were significant factors associated with inter-reader agreement.
망간은 체내 필수원소의 하나이며 주로 간과 뇌의 기저핵게 축적되며 간을 통하여 배설된다. 망간은 체내 대사가 매우 빠르기 때문에 직업적 망간 폭로를 측정하는데 어려움이 있다. 특히 용접공과 같이 망간 폭로가 간헐적이거나 불규칙한 경우에는 혈중 및 요중 망간과 같은 기존 생체폭로지표로는 장기간에 걸친 폭로량을 정확하게 반영하기 힘들다. 뇌자기공명영상이 대두됨에 따랄 뇌내에 축적된 망간을 영상으로 확인하는 것이 가능하게 되었다. 초기에는 만성간부전 및 장기간에 걸친 정맥영양주입환자 등에서 뇌기저부의 고신호간도 소견이 보고되었다. 망간은 상자성 물질로 뇌자기공명영상에서 T1 이완시간을 단축시켜 T1 강조영상에서 고신호강도를 나타난다. 망간축적에 따른 고신호강도는 주로 담창구, 흑질, 피간 및 뇌하수체 등에서 나타난다. 저자들은 최근까지 국내 및 국외에서 직업적 및 비직업적으로 망간에 폭로된 사람에서 보고된 뇌자기공명영상소견을 수집하여 분석하였다. 우선 T1강조영상에서 관찰되는 고신호 강도와 연령, 성별, 직업적 망간 폭로 및 신경학적 이상 유무간의 관계를 분석하였다. 생물학적 폭로지표와 고신호강도간의 관계도 분석하였다. 고신호강도와 뇌내 망간축적, 신경세포손상 및 신경학적 이상간의 관계에 대한 문헌들을 분석하였다. T1강조영상에서 나타나는 고신호강도는 뇌내 망간축적 정도를 반영한다. 이러한 관계를 이용하여 신호강도를 분석하므로써 뇌내 망간축적 정도를 추정할수 있다. 뇌내 망간축적은 기저핵의 신경세포손상을 초래한다. 그러나 신경학적 이상은 비교적 단기간에 걸친 망간 축적과는 무관하게 보인다. 이는 신경학적 이상소견은 마간의 누적축적량과 관련되어 있기 때문인것으로 추정된다. 뇌자기 공명영사에서 관찰되는 고신호강도 소견은 표적 장기의 망간적 축적량을 반영하는데는 충분하지 못한 것으로 보인다. 따라서이러한 놔자기공명영상의 특성 및 비용-효과적인 측면을 고려할 대 망간폭로집안에서의 망간폭로정도를 추정하기 위하여 놔자기공명영상을 사용하는 것은 바람직하지 않다고 보인다. 그러나 망간과 관련된 건강장해가 의심되는 파킨슨증 환자에서 망간폭로를 확인 및 추정하는 데에는 매우 유용하게 활용할 수 있다.
목적 : 평행영상(Parallel imaging)기법의 개발로 긴 촬영시간 때문에 종종 사용되지 못하던 삼차원 영상기법이 최근 들어 환자 병을 진단하는데 새로이 사용되고 있다. 이 연구의 목적은 최근에 뇌 영상에서 개발되어 이용되고 있는 삼차원 자기공명영상을 사람의 뇌에서 짧은 시간 내에 얻을 수 있도록 2차원 평행영상 기법을 사용한 최적화 방법을 연구하는데 있다. 대상 및 방법 : 검사 장비는 3.0T 자기공명영상장치를 이용하였으며 8-채널 SENSE(sensitivity encoding) 머리 코일을 이용하였다. 팬텀 및 3명의 사람 머리에서 영상을 얻었다. 세 가지의 삼차원 영상법인 3D T1WI, 3D T2WI 및 3D FLAIR 영상 방법에 대하여 평행인자(SENSE factor)의 변화에 따른 팬텀 영상을 얻었다. 각각의 영상법에서 영상획득에 적당한 SENSE 인자를 찾기 위해 Phase encoding 방향과 Slice encoding 방향을 조합한 SENSE 인자를 변화시키면서 영상을 얻었다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 신호대 잡음비 (Signal-to-noise ratio, SNR), 감소분율(Percent Signal Reduction Rate, %R), 대조도(contrast-to-noise ratio, CNR)를 계산하였다. 결과 : 팬텀을 이용한 SENSE 인자 변화에 따른 SNR 및 %R 값의 변화 결과 3D T1WI 방법에서 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 총 3인 경우 약 0.2%의 신호 감소가 나타났고 영상시간은 5분 이내였다. 3D T2WI 방법의 경우 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 총 3인 경우에 약 1.0% 신호 감소가 나타났고 영상 시간은 약 5분 이내였다. 3D FLAIR 방법의 경우 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 4를 사용한 경우에 약 0.2% 신호 감소가 나타났고 영상시간은 약 6분이었다. 사람을 대상으로 할 경우 3D T1W 및 3D T2W영상에서 SNR 및 CNR은 SENSE 인자를 3으로 한 경우에서 SENSE 인자를 4로 한 경우 보다 높게 나타났다. 3D FALIR 영상의 경우 CNR은 SENSE 4에서는 SENSE 3에 비하여 낮았다. 결론 : 본 연구에서는 3가지 3차원 영상법을 실제 임상적용이 가능한 시간 영역에서 SENSE 인자를 변화 시키면서 치적의 영상을 얻도록 하는 연구를 실시한 결과 SNR 감소를 최소화 하면서 영상획득 시간을 약 5분에서 6분 정도 소요되는 2차원 SENSE 인자를 찾았다. 이를 뇌 영상에 적용하였을 경우 SENSE 인자를 적용하지 않은 경우와 비교하면 신호 감소는 최소화 하면서 영상의 질은 큰 영향을 주지 않은 것으로 나타났다. 3D T1W및 3D T2W는 SENSE 인자를 3으로 3D FLAIR인자는 SENSE 인자를 4로 하는 것이 환자를 대상으로 한 뇌 영상에 적합하다고 생각된다. 앞으로는 이들 영상법이 뇌 영상뿐만 아니라 다른 영역의 영상에 적용을 위한 최적화가 필요하다고 생각된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.