• Title/Summary/Keyword: $Shadepilot^{TM}$

Search Result 6, Processing Time 0.029 seconds

Clinical Color Match using ShadepilotTM (ShadepilotTM을 이용한 색조 선택)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.219-225
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

Clinical Color Match using ShadepilotTM (ShadepilotTM을 이용한 색조 선택)

  • Shin, Soo-yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.131-137
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.

CLINICAL STUDY OF SHADE IMPROVEMENT AND SAFETY OF POLYMER-BASED PEN TYPE BlancTis Forte WHITENING AGENT CONTAINING 8.3% CARBAMIDE PEROXIDE (8.3% Carbamide Peroxide 함유 펜 형 자가미백제인 BlancTis Forte의 색조개선 및 안전성에 관한 임상연구)

  • Lee, Jin-Kyung;Min, Sun-Hong;Hong, Sung-Tae;Oh, So-Ram;Chung, Shin-Hye;Hwang, Young-Hye;You, Sung-Yeop;Bae, Kwang-Shik;Baek, Seung-Ho;Lee, Woo-Cheol;Son, Won-Jun;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.154-161
    • /
    • 2009
  • This clinical study evaluated the whitening effect and safety of polymer based-pen type BlancTis Forte (NIBEC) containing 8.3% carbamide peroxide. Twenty volunteers used the BlancTis Forte whitening agent for 2 hours twice a day for 4 weeks. As a control. Whitening Effect Pen (LG) containing 3% hydrogen peroxide was used by 20 volunteers using the same protocol. The change in shade (${\Delta}E^*$, color difference) was measured using $Shadepilot^{TM}$ (DeguDent) before, during, and after bleaching (2 weeks, 4 weeks, and post-bleaching 4 weeks). A clinical examination for any side effects (tooth hypersensitivity or soft tissue complications) was also performed at each check-up. The following results were obtained. 1. Both the experimental and control groups displayed a noticeable change in shade (${\Delta}E$) of over 2. No significant differences were found between the two groups (p > 0.05), implying that the two agents have a similar whitening effect.2. The whitening effect was mainly due to changes in a and b values rather than in L value (brightness). The experimental group showed a significantly higher change in b value, thus yellow shade, than the control (p < 0.05). 3. None of the participants complained of tooth hypersensitivity or soft tissue complications, confirming the safety of both whitening agents.

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.