• Title/Summary/Keyword: $SO_2$ measurement

Search Result 1,949, Processing Time 0.037 seconds

Evaluation of the Usefulness of Restricted Respiratory Period at the Time of Radiotherapy for Non-Small Cell Lung Cancer Patient (비소세포성 폐암 환자의 방사선 치료 시 제한 호흡 주기의 유용성 평가)

  • Park, So-Yeon;Ahn, Jong-Ho;Suh, Jung-Min;Kim, Yung-Il;Kim, Jin-Man;Choi, Byung-Ki;Pyo, Hong-Ryul;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.123-135
    • /
    • 2012
  • Purpose: It is essential to minimize the movement of tumor due to respiratory movement at the time of respiration controlled radiotherapy of non-small cell lung cancer patient. Accordingly, this Study aims to evaluate the usefulness of restricted respiratory period by comparing and analyzing the treatment plans that apply free and restricted respiration period respectively. Materials and Methods: After having conducted training on 9 non-small cell lung cancer patients (tumor n=10) from April to December 2011 by using 'signal monitored-breathing (guided- breathing)' method for the 'free respiratory period' measured on the basis of the regular respiratory period of the patents and 'restricted respiratory period' that was intentionally reduced, total of 10 CT images for each of the respiration phases were acquired by carrying out 4D CT for treatment planning purpose by using RPM and 4-dimensional computed tomography simulator. Visual gross tumor volume (GTV) and internal target volume (ITV) that each of the observer 1 and observer 2 has set were measured and compared on the CT image of each respiratory interval. Moreover, the amplitude of movement of tumor was measured by measuring the center of mass (COM) at the phase of 0% which is the end-inspiration (EI) and at the phase of 50% which is the end-exhalation (EE). In addition, both observers established treatment plan that applied the 2 respiratory periods, and mean dose to normal lung (MDTNL) was compared and analyzed through dose-volume histogram (DVH). Moreover, normal tissue complication probability (NTCP) of the normal lung volume was compared by using dose-volume histogram analysis program (DVH analyzer v.1) and statistical analysis was performed in order to carry out quantitative evaluation of the measured data. Results: As the result of the analysis of the treatment plan that applied the 'restricted respiratory period' of the observer 1 and observer 2, there was reduction rate of 38.75% in the 3-dimensional direction movement of the tumor in comparison to the 'free respiratory period' in the case of the observer 1, while there reduction rate was 41.10% in the case of the observer 2. The results of measurement and comparison of the volumes, GTV and ITV, there was reduction rate of $14.96{\pm}9.44%$ for observer 1 and $19.86{\pm}10.62%$ for observer 2 in the case of GTV, while there was reduction rate of $8.91{\pm}5.91%$ for observer 1 and $15.52{\pm}9.01%$ for observer 2 in the case of ITV. The results of analysis and comparison of MDTNL and NTCP illustrated the reduction rate of MDTNL $3.98{\pm}5.62%$ for observer 1 and $7.62{\pm}10.29%$ for observer 2 in the case of MDTNL, while there was reduction rate of $21.70{\pm}28.27%$ for observer 1 and $37.83{\pm}49.93%$ for observer 2 in the case of NTCP. In addition, the results of analysis of correlation between the resultant values of the 2 observers, while there was significant difference between the observers for the 'free respiratory period', there was no significantly different reduction rates between the observers for 'restricted respiratory period. Conclusion: It was possible to verify the usefulness and appropriateness of 'restricted respiratory period' at the time of respiration controlled radiotherapy on non-small cell lung cancer patient as the treatment plan that applied 'restricted respiratory period' illustrated relative reduction in the evaluation factors in comparison to the 'free respiratory period.

  • PDF

Effect of xylazine hydrochloride on histamine release (Xylazine이 histamine 유리에 미치는 영향)

  • 김영환;박준형
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2002
  • It has been reported that degranulation of mast cells in rats, rabbits and dog was observed after dosing xylazine hydrochloride(Xh) which has been widely used as sedative, analgesic and muscular relaxant. Therefore, this experiment was conducted to examine the relations between Xh and histamine release and to identify the action of ${\alpha}$-adrenoceptors which exists on the suface of mast cells. 1. The content of histamine within serum was measured with HPLC by performing the O-phthalaldehyde(OPA) fluorescent derivation. The pretreatment method had a little modification from the conventional method. The pretreament was carried out in the following method. 0.2$m\ell$ of serum and 1$m\ell$ of butanol were added to mixed together and then the liquid was centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 3 minutes. 0.4$m\ell$ of 0.1N HCl and 1.6$m\ell$ of heptane were added to 0.8$m\ell$ of supernatant taken from the liquid, and they were mixed together. This mixture was also centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 5 minutes. The supernatant was thrown away and the OPA fluorescent derivation was carried out with 0.2$m\ell$ of the lower liquid then, 5 minutes after mixing 400${\mu}\ell$ of 0.1N HCl, 120${\mu}\ell$ of 1N NaOH and 40${\mu}\ell$ of 0.1% OPA in the 0.2$m\ell$ of the lower liquid,120${\mu}\ell$ of 3.57N H$_3$PO$_4$ was added to the mixed liquid, and the liquid, was mixed again and syringe-filtered. Then, the measurement was done with HPLC in the 30 : 70(ν/ν) ratio of 0.004M KH$_2$PO$_4$: CH$_3$CN, flow rate of 1.0$m\ell$/min., and a wavelength of λex= 350nm and λem=444nm at the column temperature of 27$^{\circ}C$, using the fluorescence detector. 2. The content of histamine in each laboratory animal appeared to be higher in such an order as rabbit, rat, guinea pig, dog, Korean indigenous goat, swine, Korean indigenous cattle, Holstein, and mouse, of which the individual mean values${\pm}$standard deviation were 2.0668 ${\pm}$ 0.6049. 0.4999 ${\pm}$ 0.2278, 0.4241 ${\pm}$ 0.1974, 0.1054 ${\pm}$ 0.0556, 0.1028 ${\pm}$ 0.0276, 0.0972 ${\pm}$ 0.0513, 0.0872 ${\pm}$ 0.0373, 0.0717 ${\pm}$ 0.0379, and 0.0706 ${\pm}$ 0.0366, respectively. 3. The content of histamine was measured at the moments of 15-, 30-, 60-, 120-minutes after inoamuscular injection of 20mg/100kg Xh into two to 4 years old Holstein weighing 600∼700kg. The result showed that there was a significant increase at the times of 30- and 90-minutes after injection(p<0.05). 4. Intramuscular injection of 3mg/10kg Xh was given to crossbred pug dogs weighing 2.5∼4.3kg. The content of histamine was measured at the times of 30-, 60-, 90- and 120-minutes after injection. The result revealed that there was a significant increase at the times of 60-and 90-minutes after injection(p<0.05). 5. Intramuscular injection of 10mg/$m\ell$∼25mg/$m\ell$ Xh in concentration of 0.1$m\ell$ was applied to Korean indigenous goat over 5 months old. Then, the content of histamine was measured at the times of 15-, 30-, 60- and 90-minutes after injection. A significant increase was shown at the times of 30- and 60-minutes after injection(p<0.05). 6. The content of histamine was measured at the moments of 30- and 60-minutes after intramuscular injection of 0.1-0.2$m\ell$ Xh (20mg/$m\ell$) into male rabbits weighting 2.5-4kg. A significant increase was found at the moment of 60 minutes after injection(p<0.001). 7. After administering Xh to the mast cell taken from the abdominal cavity of mouse, the content of histamine was measured. The result showed that the higher the concentration, the more significantly the content of histamine was increased(p<0.05). 8. Compound 48/80 was administered in concentration of 5$\mu\textrm{g}$/$m\ell$ and 10$\mu\textrm{g}$/$m\ell$ to the mast cell picked from the abdominal cavity of mouse. The result showed that there was a significant increase in the content of histamine in case of the concentration of 10$\mu\textrm{g}$/$m\ell$(p<0.05). It was found to be about 10,000 to 500,000 times stronger than the Xh. 9. After premedication of 1mg/kg of yohimbine hydrochloride as ${\alpha}$$_2$-adrenergic antagonist to rabbits, the Xh was administered to them. The result was that the value of histamine within serum was decreased significantly(p<0.001). 10. After premeditation of 1mg/kg of prazosin hydrochloride as ${\alpha}$$_1$-adrenergic antagonist to rabbits, the Xh was administered to them. It was found that the value of histamine within serum was decreased significantly(p<0.005). 11, Prazosin hydrochloride and yohimbine hydrochloride as ${\alpha}$$_1$-adrenergic antagonist, respectively, and ${\alpha}$$_2$-adrenergic antagonist were administerd. In this case, the value of histamine within serum was decreased significantly(p<0.0001). As the results, when the Xh is administered to various kinds of animals, the amount of histamine release within serum is increased. In view of the results so far achieved, it is concluded that Xh acted on both a$_1$-adrenoreceptor and ${\alpha}$$_2$-adrenoreceptor induces the degranulation of mast cell.

Analysis on Factors Influencing Welfare Spending of Local Authority : Implementing the Detailed Data Extracted from the Social Security Information System (지방자치단체 자체 복지사업 지출 영향요인 분석 : 사회보장정보시스템을 통한 접근)

  • Kim, Kyoung-June;Ham, Young-Jin;Lee, Ki-Dong
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.2
    • /
    • pp.141-156
    • /
    • 2013
  • Researchers in welfare services of local government in Korea have rather been on isolated issues as disables, childcare, aging phenomenon, etc. (Kang, 2004; Jung et al., 2009). Lately, local officials, yet, realize that they need more comprehensive welfare services for all residents, not just for above-mentioned focused groups. Still cases dealt with focused group approach have been a main research stream due to various reason(Jung et al., 2009; Lee, 2009; Jang, 2011). Social Security Information System is an information system that comprehensively manages 292 welfare benefits provided by 17 ministries and 40 thousand welfare services provided by 230 local authorities in Korea. The purpose of the system is to improve efficiency of social welfare delivery process. The study of local government expenditure has been on the rise over the last few decades after the restarting the local autonomy, but these studies have limitations on data collection. Measurement of a local government's welfare efforts(spending) has been primarily on expenditures or budget for an individual, set aside for welfare. This practice of using monetary value for an individual as a "proxy value" for welfare effort(spending) is based on the assumption that expenditure is directly linked to welfare efforts(Lee et al., 2007). This expenditure/budget approach commonly uses total welfare amount or percentage figure as dependent variables (Wildavsky, 1985; Lee et al., 2007; Kang, 2000). However, current practice of using actual amount being used or percentage figure as a dependent variable may have some limitation; since budget or expenditure is greatly influenced by the total budget of a local government, relying on such monetary value may create inflate or deflate the true "welfare effort" (Jang, 2012). In addition, government budget usually contain a large amount of administrative cost, i.e., salary, for local officials, which is highly unrelated to the actual welfare expenditure (Jang, 2011). This paper used local government welfare service data from the detailed data sets linked to the Social Security Information System. The purpose of this paper is to analyze the factors that affect social welfare spending of 230 local authorities in 2012. The paper applied multiple regression based model to analyze the pooled financial data from the system. Based on the regression analysis, the following factors affecting self-funded welfare spending were identified. In our research model, we use the welfare budget/total budget(%) of a local government as a true measurement for a local government's welfare effort(spending). Doing so, we exclude central government subsidies or support being used for local welfare service. It is because central government welfare support does not truly reflect the welfare efforts(spending) of a local. The dependent variable of this paper is the volume of the welfare spending and the independent variables of the model are comprised of three categories, in terms of socio-demographic perspectives, the local economy and the financial capacity of local government. This paper categorized local authorities into 3 groups, districts, and cities and suburb areas. The model used a dummy variable as the control variable (local political factor). This paper demonstrated that the volume of the welfare spending for the welfare services is commonly influenced by the ratio of welfare budget to total local budget, the population of infants, self-reliance ratio and the level of unemployment factor. Interestingly, the influential factors are different by the size of local government. Analysis of determinants of local government self-welfare spending, we found a significant effect of local Gov. Finance characteristic in degree of the local government's financial independence, financial independence rate, rate of social welfare budget, and regional economic in opening-to-application ratio, and sociology of population in rate of infants. The result means that local authorities should have differentiated welfare strategies according to their conditions and circumstances. There is a meaning that this paper has successfully proven the significant factors influencing welfare spending of local government in Korea.

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

Association of osteoarthritis and bone mineral density in women -The health and nutritional examination survey in Kuri- (여성의 골관절염과 골밀도간의 관련성 분석 -구리시민 건강.영양진단 조사결과를 바탕으로-)

  • Sheen, Seung-Soo;Lee, Soon-Young;Min, Byung-Hyun;Suh, Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.669-685
    • /
    • 1997
  • Previous studies, reporting the inverse relationship between osteoarthritis and osteoporosis suggest the existence of possible pathophysiologic mechanisms between them. To examinine the hypothesis that 'bone mineral densities of women with osteoarthritis are significantly higher than that of women without osteoarthritis in Korea', subjects from the health and nutritional examination survey in Kuri city were sampled. Samples were selected through multi-stage sampling frame using established clusters in Kuri city. From August 18 to September 10,1997, the survey was conducted. Among the. total number of selected sample population (1,656 people), response .ate was 52.4 percent (348 men and 519 women). 420 women who took BMD measurement, radiologic exam, and anthropometric exam were selected for the analysis. The analytic results are as follows. 1. General characteristics: Mean BMD was $0.493g/cm^2$, mean age was 43.0, mean BMI was $23.9kg/m^2$. The number of women who experienced menopause was 106, hysterectomy was 19. There were 0 case of osteoarthritis of hip, 64 cases of osteoarthritis of knee, and 2 cases of osteoarthritis of hand. 2. Univariate analysis results: Mean BMD of women with the osteoarthritis of knee was significantly lower than that of women without the osteoarthritis of knee(0.4269 vs. $0.5057g/cm^2$). But, there were too few cases of osteoarthritis of hip and hand, so comparative studies of BMD in osteoarthritis of hip and hand could not be conducted. There were significant differences of BMD among pre-menopause group(0.5204), post-menopause group(0.4206), and hysterectomy group(0.4881). Additionally, there were significant differences of BMD among diabetes group(0.4297), impaired glucose tolerance group(0.4874), and normal group(0.5057). Furthermore, age, parity, BMI, bioimpedance were significantly related with BMD. 3. Multivariate analysis results: To examinine the relationship between osteoarthritis and BMD while controlling the other variables' effects which were significant in the univariate analyses, multiple linear regression analysis was done. But, it was found that osteoarthritis of knee was not a significant variable to BMD anymore. While age and menopause had significant negative relationship with BMD. Diabetes, parity, BMI, and bioimpedance did not have significant relationships with BMD. After stratification of subjects according to menopause, multiple linear regression analyses were done to each strata. Consequently, age in post-menopause group, age and osteoarthritis of knee in hysterectomy group showed significant negative relationship with BMD. The results did not support the many results of other previous studies done with white men and women. further studies of biological plausibility to Korean women are recommended. Also it is suggested that longitudinal study to verify the relationship between osteoarthritis and BMD will be valuable.

  • PDF

GPU Based Feature Profile Simulation for Deep Contact Hole Etching in Fluorocarbon Plasma

  • Im, Yeon-Ho;Chang, Won-Seok;Choi, Kwang-Sung;Yu, Dong-Hun;Cho, Deog-Gyun;Yook, Yeong-Geun;Chun, Poo-Reum;Lee, Se-A;Kim, Jin-Tae;Kwon, Deuk-Chul;Yoon, Jung-Sik;Kim3, Dae-Woong;You, Shin-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.80-81
    • /
    • 2012
  • Recently, one of the critical issues in the etching processes of the nanoscale devices is to achieve ultra-high aspect ratio contact (UHARC) profile without anomalous behaviors such as sidewall bowing, and twisting profile. To achieve this goal, the fluorocarbon plasmas with major advantage of the sidewall passivation have been used commonly with numerous additives to obtain the ideal etch profiles. However, they still suffer from formidable challenges such as tight limits of sidewall bowing and controlling the randomly distorted features in nanoscale etching profile. Furthermore, the absence of the available plasma simulation tools has made it difficult to develop revolutionary technologies to overcome these process limitations, including novel plasma chemistries, and plasma sources. As an effort to address these issues, we performed a fluorocarbon surface kinetic modeling based on the experimental plasma diagnostic data for silicon dioxide etching process under inductively coupled C4F6/Ar/O2 plasmas. For this work, the SiO2 etch rates were investigated with bulk plasma diagnostics tools such as Langmuir probe, cutoff probe and Quadruple Mass Spectrometer (QMS). The surface chemistries of the etched samples were measured by X-ray Photoelectron Spectrometer. To measure plasma parameters, the self-cleaned RF Langmuir probe was used for polymer deposition environment on the probe tip and double-checked by the cutoff probe which was known to be a precise plasma diagnostic tool for the electron density measurement. In addition, neutral and ion fluxes from bulk plasma were monitored with appearance methods using QMS signal. Based on these experimental data, we proposed a phenomenological, and realistic two-layer surface reaction model of SiO2 etch process under the overlying polymer passivation layer, considering material balance of deposition and etching through steady-state fluorocarbon layer. The predicted surface reaction modeling results showed good agreement with the experimental data. With the above studies of plasma surface reaction, we have developed a 3D topography simulator using the multi-layer level set algorithm and new memory saving technique, which is suitable in 3D UHARC etch simulation. Ballistic transports of neutral and ion species inside feature profile was considered by deterministic and Monte Carlo methods, respectively. In case of ultra-high aspect ratio contact hole etching, it is already well-known that the huge computational burden is required for realistic consideration of these ballistic transports. To address this issue, the related computational codes were efficiently parallelized for GPU (Graphic Processing Unit) computing, so that the total computation time could be improved more than few hundred times compared to the serial version. Finally, the 3D topography simulator was integrated with ballistic transport module and etch reaction model. Realistic etch-profile simulations with consideration of the sidewall polymer passivation layer were demonstrated.

  • PDF

IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS (2종 전자근관장측정기의 일관성에 관한 in vitro 연구)

  • Hwang, Gyu-Young;Roh, Byoung-Duck;Kim, Eui-Sung;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.

A Study on a Effect of Product Design and a Primary factor of Qualify Competitiveness (제품 디자인의 파급효과와 품질경쟁력의 결정요인에 관한 연구)

  • Lim, Chae-Suk;Yoon, Jong-Young
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.95-104
    • /
    • 2005
  • The purpose of this study is to estimate the determinants of product design and analyze the impacts of product design on quality competitiveness, product reliability, and consumer satisfaction in an attempt to provide a foundation for the theory of design management. For this empirical analysis, this study has derived the relevant measurement variables from a survey on 400 Korean manufacturing firms during the period of $August{\sim}October$ 2003. The empirical findings are summarized as follows: First, the determinants of product design are very significantly (at p<0.001) estimated to be the R&D capability, the level of R&D expenditure, the level of innovative activities(5S, TQM, 6Sigma, QC, etc.). This empirical result can support Pawar and Driva(1999)'s two principles by which the performance of product design and product development can be simultaneously evaluated in the context of CE(concurrent engineering) of NPD(newly product development) activities. Second, the hypothesis on the causality: product design${\rightarrow}$quality competitiveness${\rightarrow}$customer satisfaction${\rightarrow}$customer loyalty is very significantly (at p<0.001) accepted. This implies that product design positively affects consumer satisfaction, not directly but indirectly, by influencing quality competitiveness. This empirical result of this study can also support the studies of for example Flynn et al.(1994), Ahire et at.(1996), Afire and Dreyfus(2000) which conclude that design management is a significant determinant of product quality. The aforementioned empirical results are important in the following sense: the empirical result that quality competitiveness plays a bridging role between product design and consumer satisfaction can reconcile the traditional debate between QFD(quality function development) approach asserted by product developers and conjoint analysis maintained by marketers. The first empirical result is related to QFD approach whereas the second empirical result is related to conjoint analysis. At the same time, the empirical results of this study can support the rationale of design integration(DI) of Ettlie(1997), i.e., the coordination of the timing and substance of product development activities performed by the various disciplines and organizational functions of a product's life cycle. Finally, the policy implication (at the corporate level) from the empirical results is that successful design management(DM) requires not only the support of top management but also the removal of communication barriers, (i.e. the adoption of cross-functional teams) so that concurrent engineering(CE), the simultaneous development of product and process designs can assure product development speed, design quality, and market success.

  • PDF

GROWTH AND DEVELOPMENT OF ARCH FORM (치열궁의 성장 변화)

  • Sohn, Byung-Wha;Baik, Hyoung-seon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.17-27
    • /
    • 1998
  • Study on growth change of dental arch is considered to both an important data in orthodontic diagonsis and treatment planning as well as analysis of treatment results , also, arch form is important in anthropology and dentistry, even more so in prosthodontics and orthodontics. In the field of orthodontics, studies on the functional aspect of upper and lower teeth and maintenance of stability of dentition and occlusion were carried out from the early days. Some of the early studies include explanation of growth change in dental arch from measuring directly fom human stroll, and afterwards, cephalometrics x-rays were introduced; accordingly, studies using cephalometric measurement and linear measurements of study models were often performed. By this method, arch width, arch depth and perimeters were measured, and growth change or dental arch was studied. The subject ror this study were sn children(boys and girls or ages from 3 yens to 12 years from Kang-won district and Seoul, who has no history of orthodontic treatment and who show healthy status and normal growth and development. Cephalometric x-ray, panoramic x-ray, and study model were taken for each subject consecutively for 2 years, and the subjects are still followed up. 400 pairs of study models from the past two years were used in this study; mesio-distal diameater of each tooth, intercanine width, intermolar width, canine depth, molar depth and arch perimeters were measured. Afterwards, mean value and each standard deviation of each age group and each gender were obtained, and representation graph were drawn. The following conclusion were obtained. 1. Intercanine width showed gradual increase until the age of 10-years and after that, showed no increase. 2. Intermolar width in upper arch showed gradual increase : intermolar width in lower arch showed no significant chang, and after the age of 9-years, showed increase. 3. Cainine arch depth showed relatively rapid increase after the age of 6-years, and this pattern was more obvious in lower arch. 4. Molar arch depth increased gradually in both archs and it decrease after the age of 10-years : this phenomenon was more prominent in the lower arch. 5. Arch perimeter showed gradual inerease and convert to plateau at the age of 10-years, after that, it decreased. this pattern was more prominent in lower arch.

  • PDF

Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL) (전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로)

  • Lee, Seoyoung;Kim, Kyunglee;Ha, Hyekyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 2013
  • In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were $1.0058{\pm}0.0074$. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.