• 제목/요약/키워드: $SO_{2}$ Removal Efficiency

검색결과 370건 처리시간 0.03초

DeSOx/DeNOx 효율 개선을 위한 펄스 코로나 방전하에서 기체미립자 전환반응의 적용 (Application of Gas to Particle Conversion Reaction to increase the DeSOx/DeNOx Efficiency under Pulsed Corona Discharge)

  • 최유리;김동주;김교선
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.249-258
    • /
    • 1998
  • In this paper, we investigated the post-combustion removal of nitrogen oxide($NO_x$) and sulfur oxide($SO_x$) which is based on the gas to particle conversion process by the pulsed corona discharge. Under normal pressure, the pulsed corona discharge produces the energetic free electrons which dissociate gas molecules to form the active radicals. These radicals cause the chemical reactions that convert $SO_x$ and $NO_x$ into acid mists and these mists react with $NH_3$ to form solid particles. Those particles can be removed from the gas stream by conventional devices such as electrostatic precipitator or bag filter. The reactor geometry was coaxial with an inner wire discharge electrode and an outer ground electrode wrapped on a glass tube. The simulated flue gas with $SO_x$ and $NO_x$ was used in the experiment. The corona discharge reactor was more efficient in removing $SO_x$ and $NO_x$ by adding $NH_3$ and $H_2O$ in the gas stream. We also measured the removal efficiency of $SO_x$ and $NO_x$ in a cylinder type corona discharge reactor and obtained more than 90 % of removal efficiency in these experimental conditions. The effects of process variables such as the inlet concentrations of $SO_x$, $NH_3$ and $H_2O$, residence time, pulse frequencies and applied voltages were investigated.

  • PDF

알루미나에 의한 수용액 중의 산성이온 제거 특성 (Removal Characteristic of Acidic Ion in Aqueous Solution by Alumina)

  • 홍영호
    • 공업화학
    • /
    • 제18권5호
    • /
    • pp.454-458
    • /
    • 2007
  • 본 연구는 알루미나를 이용하여 수용액 중에 존재하는 $Ca^{2+}$, $Mg^{2+}$, $Sr^{2+}$, $SO{_4}^{2-}$, $NO{_3}^-$, $Cl^-$ 이온의 제거 특성을 분석하기 위하여 실시하였다. 알루미나는 $Al(NO_3)_3{\cdot}9H_2O$$NH_4OH$를 사용하여 합성한 수화물을 $450{\sim}750^{\circ}C$로 5 h 동안 열처리하고 FT-IR과 Brunauer-Emmett-Teller (BET)법으로 물성을 분석하였다. 실험결과에 의하면 알루미나의 비표면적은 열처리 온도가 증가하면 감소하는 특성을 나타내었다. 알루미나에 의한 흡착능은 $SO{_4}^{2-}$$NO{_3}^-$가 각각 23 mg/g와 12.4 mg/g의 값을 보였다. 반면에 $Cl^-$는 4 mg/g으로 비교적 낮은 값을 보였다. 일반적으로 음이온 제거 효율은 알루미나의 제조를 위한 열처리 온도가 증가할수록 감소하였으며, $450^{\circ}C$로 처리한 알루미나의 경우에 가장 좋은 처리 효율을 나타내었다. 양이온인 $Ca^{2+}$, $Mg^{2+}$, $Sr^{2+}$의 제거 효율은 알루미나의 열처리 온도에 비례하여 증가하는 경향을 보였다.

The Investigation of Treatment of Pistachio Processing Industrial Wastewater by Electrochemical Methods in Terms of Chemical Oxygen Demand and Total Phenol Removal

  • Alper Erdem Yilmaz;Baybars Ali Fil;Murat Tolga Yilmaz;Serkan Bayar;Zuhal Koksal
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.178-189
    • /
    • 2024
  • This work aims to investigate the efficiency of electrocoagulation (EC) of pistachio processing industrial wastewater (PPIW) using the continuous EC process. The tubular reactor made of stainless steel with an internal diameter of 60 mm was used as a cathode electrode. The effect of some parameters was examined on the removal of chemical oxygen demand (COD) and total phenols (TP) removal efficiency. The influences of the initial pH of wastewater (from 4 to 8), flow rate (from 25 to 125 mL/min), current density (from 7 to 21 mA/cm2), and supporting electrolyte type (NaCl, NaNO3, and Na2SO4), supporting electrolyte concentration (from 10 to 100 mg/L NaCl) on removal efficiency were investigated to determine the best experimental conditions. The examination of the physico-chemical parameters during the EC treatment showed that the best removal efficiency was obtained under conditions where the flow rate was 25 mL/min (20 min reaction time), the pH value was 5.2, and the current density was 21 mA/cm2 has set. Under these experimental conditions, COD and TP removal efficiency were found to be 75% and 97%, respectively, while energy consumption was 18.5 kW h/m3. The study results show that the EC can be applied to PPIW pre-treatment.

폐수내 질소 및 인 제거를 위한 struvite 결정화 최적조건 도출 (Estimation of the Optimum Factor of the Struvite Crystalization for the Nitrogen and Phosphorus Removal in WWTP)

  • 김지연;문용택;서인석;김병군
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.745-753
    • /
    • 2007
  • By struvite and hydroxyapatite crystallization, was high concentration of nitrogen and phosphorus in wastewater simultaneously. Particularly, removal of nitrogen and phosphate for crystallization have been applied to landfill leachates and animal wastewater. The purpose of this study is to decide the optimum struvite crystallization factors, sequence of $Mg^{2+}$ addition, pH control and the molar ratio of $Mg^{2+}$ over $PO_4^{3-}$. In conclusion, dosage of the magnesium followed by pH control formed magnesium hydroxide, so pH was decreased. Therefore, pH adjustment should followed by after magnesium dosage and then pH should be adjusted to 11. Over pH 10, it was not good for struvite crystallization efficiency by side reaction. Following of the $Mg^{2+}$ and the $PO_4^{3-}$ are dosed excessively, the removal efficiency of the $NH_4^+$ increased. A molar ratio of $Mg^{2+}:NH_4^+:PO_4^{3-}$, 1.3:1:1.3 was the most on effective for $NH_4^+$ removal at pH 9.5. But for the perfect removal $NH_4^+$, it is thought to be that molar ratio should be 2:1:2.

펜톤 산화반응에 의한 염색폐수처리 연구 (Treatment Study of Textile Wastewater by Fenton's Oxidation)

  • 박영규
    • 환경위생공학
    • /
    • 제15권4호
    • /
    • pp.20-25
    • /
    • 2000
  • The wastewater treatment for the purpose of water-recycling was performed using Fenton's & ozone's methods. These methods were used to increase the treatment efficiency of textile wastewater and to search for the optimal operating conditions. The optimal conditions by Fenton process were determined so that input amounts of $FeSO_4{\cdot}7H_2O$ and $H_2O_2$ were $7.2mM/{\;}{\ell}$ and $49.0m/{\;}{\ell}$ respectively, treatment by ozone process had 92% removal efficiency at ozone concentration of 9.73g/min and $130mM/{\;}{\ell}$ of $H_2O_2$.

  • PDF

도시폐기물매립지침출수의 병합처리에 관한 연구 (A Study on the Combined Treatment of Municipal Solid Waste Landfill Leachate)

  • 김동민;이병인
    • 환경위생공학
    • /
    • 제11권1호
    • /
    • pp.45-55
    • /
    • 1996
  • An experimental research was conducted in order to study the combined treatment o of municipal landfill leachate and municipal sewage. The landfill leachate was that of Nanjido landfill site, and the municipal sewage was that of Chungnang municipal sewage treatment plant in Seoul. Several sets of bench~scale sequencing batch reactor(SBR) were used as e experimental apparatus. Specially investigated items in this experiment were the removal efficiency of substrate and the influence of treatment time. The experiment lasted for about 2 years. The result are as follows ; 1. The characteristics of leachate were pH 7.5~8.2, BOD 80~336mg/L, COD 908~1,460mg/L, NH3-N 1,409~2,330mg/L, T~P 2.7~7.lmg/L, Cl~3,540~4,085mg/L, a and heavy metals are a very small amount. And the characteristics of sewage were pH 6.9~7.3, BOD 78.4~129.3mg/L, COD 121.2~305.0mg/L, T~N 14.9~36.4mg/L, T-P 2.3~8.9mg/L. 2. The treatability of leachate alone was not treat well. So for the good treatment of leachate, it was necessary to deal with the pretreatment before bi이ogical treatment and a combined treatment of municipal sewage. 3. The various contents of the leachate were 5%, 10%, 30%, and 50%, and the removal efficiency of COD was 86.0%, 82.8%, 60.6%, and 31.7%. The maximum content of the leachate which could be sucessfully treated by SBR in the combined treatment was 10% of that of sewage. And the removal efficiency of COD increased n notably, as its treatment time increased. 4. The various contents of the electrolytic treated leachate were 5%, 10%, 30%, and 50%, and the removal efficiency of COD was 89.9%, 86.1%, 79.2%, and 69.8%. The maximum content of the leachate which could be sucessfully treated by SBR in the combined treatment was 30 % of that of sewage. And the removal efficiency of C COD increased notably, as its treatment time increased.

  • PDF

순산소연소 조건에서 석회석의 소성특성 및 로내탈황에 관한 연구 (Study on Calcination Characteristics of Limestones for In-Furnace Desulfurization in Oxy-Fuel Combustion)

  • 안영모;조항대;최원길;박영성;길상인;이형근
    • 대한환경공학회지
    • /
    • 제31권5호
    • /
    • pp.371-377
    • /
    • 2009
  • 순산소연소 배가스 중 $CO_2$ 농도는 가스의 재순환으로 인해 95%까지 농축 가능하며, $CO_2$ 농도가 높은 조건에서 석회석의 소성특성은 기존의 공기 연소와 다르게 나타난다. 본 연구에서는 흡수제로 특성이 다른 세 종류의 국내산 석회석을 이용하여, 소성온도에 따른 석회석의 소성특성에 대해 알아보았다. 또한 흡수제 종류, 반응온도 등의 운전변수가 $SO_2$ 제거효율에 미치는 영향에 대하여 알아보고, 반응생성물을 포집하여 황 함량을 측정하였다. 소성온도가 증가함에 따라 석회석의 소성율 및 비표면적은 증가하는 경향을 보였으며, 반응온도가 증가함에 따라 $SO_2$ 제거효율은 증가하였으며 석회석의 종류에 따라 $SO_2$ 제거효율이 뚜렷한 차이를 보였다. 최고효율 나타낸 석회석 시료에 대한 반응생성물 분석결과 시료 내 황 함량은 약 10% 정도인 것으로 나타났다.

고도단계유입폭기법과 표준활성슬러지법의 처리특성 비교 (A Study of the comparison of the treatment characteristics between ASA system and CAS system)

  • 강용태;조용현;한상윤
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2007년도 춘계학술발표논문집
    • /
    • pp.112-115
    • /
    • 2007
  • Currently an increase in domestic sewage and industrial wastewater causes serious water pollution in Korea. To solve water pollution problems, conventional activated sludge (CAS) system is generally used in wastewater treatment plant but this process is so ineffective in nitrogen and phosphorus. Even if CAS system is the major process, it must be improved instantly so as to remove nitrogen and phosphorus. Otherwise, the serious water pollution problems can't be resolved with CAS system. Therefore this study focused on the comparison of the treatment characteristics between ASA system and CAS system. And also the mass balance of each process of ASA system. The results from operating advanced step aeration (ASA) system indicated that the removal efficiency of BOD, COD, and SS was 89.9%, 74.5%, and 89.0% respectively. In comparison, the removal efficiency of BOD, COD, and SS for CAS system was 89.5%, 71.8%, and 89.5% respectively. In addition to the results, the TN removal efficiency of ASA system was 76.5% comparing to 32.7% of CAS system. It was concluded that the TN removal efficiency of ASA system was 44% higher than CAS system. And the TP removal efficiency was 81.4% in ASA system comparing to 25.2% in CAS system. It also means that over 56% of TP was removed in ASA system comparing to CAS system.

  • PDF

SO2 제거를 위한 중공사막 기-액 접촉기의 모사 및 분리막 물질 전달 계수 추정 (The Computer Simulation and Estimation of Membrane Mass Transfer Coefficients of Hollow Fiber Membrane G-L Contactors for SO2 Removal)

  • 김용국;송희열;이형근;김인원
    • Korean Chemical Engineering Research
    • /
    • 제45권1호
    • /
    • pp.81-86
    • /
    • 2007
  • 산업 시설에서 발생하는 $SO_2$를 제거하기 위해 중공사막 기-액 접촉기를 사용하고 있다. 본 연구에서는 기-액 접촉기 내의 중공사막에서의 $SO_2$ 흡수거동 대하여 수학적으로 모델링하고, 그 모델을 유한 요소 분석법을 이용하여 모사하였다. $SO_2$의 분리에 영향을 주는 변수인 기체 유량, 분리막의 물질 전달 계수 및 접촉기의 물리적 특성에 따른 $SO_2$의 분리 효율 및 물질 전달 특성을 알아보았다. 기체의 유속 변화에 따른 중공사막을 통한 $SO_2$ 제거 효율 실험값으로부터 분리막의 물질 전달 계수를 추정하였다. 또한 중공사막 설계에 도움이 되는 자료를 계산할 수 있는 방법을 제시하였다.

축산폐수의 후처리공정으로서 SBR 적용시 운전인자에 따른 질소와 인의 제거특성에 관한 연구 (A Study on the Removal of Nitrogen and Phosphorus by Operation Mode for Livestock Wastewater Treatment Post-process Using SBR)

  • 최건열;이영신
    • 한국환경보건학회지
    • /
    • 제35권3호
    • /
    • pp.214-219
    • /
    • 2009
  • This study examined the removal efficiency of the nitrogen and phosphorus in order to compensate for the combined process of ATAD(Autothermal Thermophilic Aaerobic Digestion) and EGSB(Expended Granular Sludge Bed), which are treatment methods for livestock wastewater, by introducing SBR(Sequencing Batch Reactor) as post-treatment process. The analysis on the treatment efficiency of each operation mode showed that, in the case of T-N, the treatment efficiency were 67.1% and 74.2% for Run-1 and Run-2, respectively, and in the case of T-P, the values were 71.2 and 74.1, respectively, which are indicating that the treatment efficacy is higher in the condition of Run-1, in which the time period of Anoxic and Aerobic segments were increased. In addition, the result of analyzing removal characteristics of nitrogen and phosphorus by Influx load showed that removal efficiency of nitrogen was better in the case of high influx load than in the case of low influx load. Regardless of Influx load, phosphorus showed constant influx concentration, so that removal efficiency of phosphorus was influenced littler by Influx load than that of nitrogen. This study also fed methanol as an external carbon source and performed experiment to induce denitrification under anoxic condition by using nitrate among nitrogen compounds of SBR reactor, and the results showed that intermittent feeding was more effective in Nitrogen Removal than composite feeding.