• Title/Summary/Keyword: $SF_{6}$ Gas Gap

Search Result 66, Processing Time 0.037 seconds

Study on The Small-Gap Measuring System for Gas Velocity Measurement of $SF_6$ Gas Circuit Breaker ($SF_6$ 가스차단기에서 가스 속도측정을 위한 Small-Gap 측정시스템에 관한 연구)

  • Kim Hong-Kyu;Dong Song-Ki;Lee Woo-Young;Park Kyong-Yop;Chong Jin-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.3
    • /
    • pp.139-144
    • /
    • 2005
  • [ $SF_6$ ] gas circuit breakers are widely used short circuit current interruption in EHV or UHV power system. For a $SF_6$ gas circuit breaker development, the $SF_6$ gas velocity measurement is necessary during $SF_6$ circuit breaker's trip operation. Small-gap flashover characteristics are used for this measurement. So, small-gap measuring system which will be used to develope GCB should be developed. This study shows the characteristic analysis and experimental results of small-gap measuring system.

A Study on the Flashover along the Spacer Surface SF6-N2 Gas Mixtures Stressed by D.C (SF6및 SF6-N2 가스 중에서 직류전동에 \ulcorner나 스페이서 연면간락에 관한 연구)

  • 김정달;정재길;이동인
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.11
    • /
    • pp.796-805
    • /
    • 1987
  • The flashover voltages have been investigated for spacer and unbridged-gap in SF6-N2 gas mixtures up to the value of 760(torr. cm), The gap was stressed by DC source The results obtained are as follows` 1) The flashover voltages for an unbridged gap and for a spacer in SF6, N2 and SF6-N2 gas mixtures follow the Paschen's curve. 2) The polarity effects was not observed in both unbridged gap and a spacer which had per ect contact with an electrode. The flashover voltages for negative polatity are lower than those for positive polarity in case of imperfect contact. 3) 3%flashover voltage is decreased by putting a spacer which had perfect contact with an electrode. The spacer which has a gap void shows the lowest flashover voltage. 4) The lowest spacer efficiency was obtained with higher gas pressure & large amount of N2 content. The flashover voltages depend on the gas pressure rather than the spacer efficienty at low value of pd. 5) The flashover voltages of gas mixtures of N2 with SF6 are relatively high, even though the amount of SF6 gas content is small.

  • PDF

A Study on A Hot Gas Velocity Measurement in GCB Using Small-Gap (Small-Gap을 이용한 가스차단기에서의 열가스 속도측정에 관한 연구)

  • Kim, Hong-Kyu;Song, Ki-Dong;Park, Kyong-Yop;Hong, Jung-Pyo;Chong, Jin-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.3
    • /
    • pp.155-158
    • /
    • 2006
  • $SF_6$ gas circuit breakers we widely used for short circuit current interruption in EHV or UHV power system. For a $SF_6$ gas circuit breaker development, the hot gas velocity measurement is necessary during $SF_6$ gas circuit breaker's trip operation. Small-gap flashover characteristics are used for this hot gas velocity measurement. This study sho was the hot gas velocity measurement results during $SF_6$ gas circuit breaker' trip operation.

Characteristics of lightning impulse breakdowns in inhomogeneous $SF_6$ gas gap (불평등전장에서 $SF_6$ 기체의 뇌임펄스 절연파괴특성)

  • Lee, B.H.;Choi, H.S.;Oh, S.K.;Li, F.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1921-1923
    • /
    • 2004
  • V-p characteristics and the discharge luminous characteristics in inhomogeneous $SF_6$ gas gap under the positive and negative lightning impulse voltages are presented. The test gap was composed of the plane-to-plane with a needle-shaped protrusion. The applied voltage and the predischarge current were measured by the electric field sensor and the shunt of 50 ${\Omega}$, respectively. The light emission signals were observed by a photomultiplier tube, and a high-speed camera. In a consequence, the dielectric strengths of $SF_6$ gas gap under positive lightning impulse voltages were independent of the gas pressure. In the presence of the positive polarity, the branches of discharge channel were created and the directions of the discharge paths were random. On the other hands, the discharge paths of the negative polarity were more thicker and brighter.

  • PDF

Partial Discharge Phenomenon with $SF_6$ Gas Pressures in Insulation consisting of Insulation Paper and $SF_6$ Gas (SF_6 가스와 절연지의 절연계에서 가스압력에 따른 부분방전현상)

  • 선종호;김광화;박정후;조정수
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.65-71
    • /
    • 2001
  • This paper describes partial discharge phenomenon with SF6gas pressures in insulation consisting of insulation paper and SF6 gas. We made the specimens with SF6 gas gaps which exist between aramid papers and electrodes and calculated the electric field intensity in the these gaps. We measured the partial discharge inception voltages and the AC breakdown voltages with the test method of IEC 60060-2 and did the partial discharge degradation experiments with a constant voltage. According to gas pressures, the breakdown voltages in SF6gas gaps were calculated by Paschen's law. And these results showed the ability applying partial discharge inception voltages evaluation to Paschen's law and the relationship between the PD quantities occurring insulation breakdown and PD occurring area.

  • PDF

Breakdown Characteristics of $SF_6/CF_4$ Mixtures under AC Voltages in Uniform, Nonuniform Field (평등, 불평등 전계에서 AC전압의 $SF_6/CF_4$ 혼합가스 절연내력 특성)

  • Sung, Heo-Gyung;Hwang, Cheong-Ho;Kim, Nam-Ryul;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1334-1335
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in uniform and nonuniform field was performed. The experiments were carried out under AC voltages. The sphere-sphere electrode whose gap distance was 1 mm was used and the point-plane electrode whose gap distance was 3 mm was used in a test chamber. $SF_6/CF_4$ mixture contained 20% $SF_6$ and 80% $CF_4$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The results show that addition of $SF_6/CF_4$ mixtures increase AC breakdown voltages. In uniform field the breakdown voltages of gas were linearly increased according to the pressure. However in nonuniform field the breakdown voltages of gas were increased nonlinearly.

  • PDF

부성기체 $SF_6$Gas의 방전특성과 고기압 $SF_6$Gas중에서의 impulse corona에 관한 소고

  • 서국철
    • 전기의세계
    • /
    • v.25 no.6
    • /
    • pp.45-48
    • /
    • 1976
  • 과거 수십년간 전력계통의 절연에 쓰여 온 공기에 대치하여 근년 고기압 SF$_{6}$gas에 의한 gas절연 방식이 급속도로 진전되고 있으며 거기에 수반하여 SF$_{6}$gas의 방전특성 해명이 초고압 장 gap영역에서 급선무로 되어 있다. 또한 초고압송전에 대응하는 각종 전력기기 cable등의 고기압 절연이 실용화 하게 되었으며 신뢰도가 높고 합리적인 gas 절연기기의 설계를 목표로 부성기체 특히 고기압 SF$_{6}$gas의 절연파괴 특성의 연구가 진행되고 있다. 고기압 SF$_{6}$gas는 높은 파괴 전체를 가지므로 극히 적은 원인으로도 절연 특성에 영향을 미치며 공기, 질소등 기체와는 매우 다른 방전 특성을 나타낸다. 여기서는 SF$_{6}$gas의 특이한 방전 특성과 고기압 SF$_{6}$gas 중에서의 impulse corona의 특성을 고찰하려고 한다.

  • PDF

Dielectric Characteristics of $SF_6$ Gas in Inhomogeneous Field (불평등 전계중에서 $SF_6$가스의 절연특성)

  • Lee, Chang-Jun;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1870-1872
    • /
    • 1996
  • This paper presents dielectric characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The propose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane and two needles-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was 22 mm and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

Dielectric Characteristics of $SF_6$ Gas Stressed by VFTO in inhomogeneous Field (불평등전계중에서 VFTO에 의한 $SF_6$가스의 방전특성)

  • Lee, B.H.;Lee, C.J.;Ahn, C.H.;Lee, K.O.;Ha, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.282-284
    • /
    • 1996
  • This paper presents prebreakdown characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The purpose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was22 mm, and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

Partial Discharge Phenomena with $SF_{6}$ Gas Pressures in Insulation Consisted of Insulation Paper and $SF_{6}$ Gas(II) ($SF_{6}$가스와 절연지의 절연계에서 가스압력에 따른 부분방전 현상(II))

  • Seon, Jong-Ho;Kim, Gwang-Hwa;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.430-435
    • /
    • 2002
  • The $SF_{6}$ gas insulated power equipments have the insulation systems which are composed of $SF_{6}$ gas and insulation paper. It is repored that their insulation abilities are influenced by the $SF_{6}$ gas gaps in those insulation systems and gas pressures. This paper describes partial discharge phenomena with $SF_{6}$ gas pressures in insulation system of $SF_{6}$ gas-insulation paper Specimens of $SF_{6}$ gas-insulation paper were prepared and aramid paper was used as insulation paper. Partial discharge inception voltages(PDIV) and breakdown voltages for the existence of $SF_{6}$ gas gaps were measured by short term tests with gas pressures. Also, average PD quantities and pulse counts, life times of each specimens were calculated from the results of long term aging tests with gas pressures. It was found that the $SF_{6}$ gas gaps decrease increasing rates of PDIV and brealdown voltages according to gas pressure increase and the insulation breakdown caused by the smaller PD quantities than 1[pC] at the high gas pressure of 300kPa is due to the increase of energy density with increase of gas pressure.