• 제목/요약/키워드: $Ru_{dpp}$

검색결과 5건 처리시간 0.015초

The Concentration-Dependent Distribution of Tris(4,7'-diphenyl-1,10'-phenanthroline) Ruthenium (II) within Sol-Gel-Derived Thin Films

  • Lee, Joo-Woon;Cho, Eun-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2765-2770
    • /
    • 2011
  • Organic dye-doped glasses, viz., ruthenium (II) tris(4,7'-diphenyl-1,10'-phenanthroline) $[Ru(dpp)_3]^{2+}$ incorporated into thin silica xerogel films produced by the sol-gel method, were prepared and their $O_2$ quenching properties investigated as a function of the $[Ru(dpp)_3]^{2+}$ concentration (3-400 ${\mu}M$) within the xerogel. The ratio of the luminescence from the $[Ru(dpp)_3]^{2+}$-doped films in the presence of $N_2$ and $O_2$ ($I_{N2}/I_{O2}$) was used to describe the film sensitivity to $O_2$ quenching. ($I_{N2}/I_{O2}$ changed three-fold over the $[Ru(dpp)_3]^{2+}$ concentration range. Time-resolved intensity decay studies showed that there are two discrete $[Ru(dpp)_3]^{2+}$ populations within the xerogels (${\tau}_1$ ~ 300 ns; ${\tau}_2$ ~ 3000 ns) whose relative fraction changes as the $[Ru(dpp)_3]^{2+}$ concentration changes. The increased $O_2$ sensitivity that is observed at the higher $[Ru(dpp)_3]^{2+}$ concentrations is a manifestation of a greater fraction of the 3000 ns $[Ru(dpp)_3]^{2+}$ species (more susceptible to $O_2$ quenching). A model is presented to describe the observed response characteristics resulting from $[Ru(dpp)_3]^{2+}$ distribution within the xerogel.

HPTS, Rudpp를 활용한 pH 및 용존산소 모니터링 시스템 연구 (Development of a pH/dissolved- oxygen Monitoring System Using HPTS and Rudpp)

  • 정동혁;정대웅
    • 센서학회지
    • /
    • 제32권2호
    • /
    • pp.82-87
    • /
    • 2023
  • This study proposes a pH-dissolved-oxygen monitoring system using 8-HydroxyPyrene-1,3,6-trisulfonic acid Trisodium Salt (HPTS) and tris(4,7-diphenyl-1,10-phenanthroline)Ruthenium(II) chloride (Rudpp). Commercial water-quality sensors are electrochemical devices that require frequent calibration and cleaning, are subject to high maintenance costs, and have difficulties conducting measurements in real-time. The proposed pH-dissolved-oxygen monitoring system selects a thin-film sensing layer to measure the change in fluorescence intensity. This change in fluorescence intensity is based on reactions with hydrogen ions in an aqueous solution at a given pH and specific amount of dissolved oxygen. The change in fluorescence intensity is then measured using light-emitting diodes and photodiodes in response to HPTS and Rudpp. This method enables the development of a relatively small, inexpensive, and real-time measureable water-quality measurement system.

생물공정 모니터링을 위한 광섬유 포도당 및 젖산 센서의 개발 (Development of Optical Fiber Glucose and Lactate Biosensors for Bioprocess Monitoring)

  • 정창환;손옥재;이종일
    • KSBB Journal
    • /
    • 제32권1호
    • /
    • pp.35-45
    • /
    • 2017
  • In this work the optical fiber glucose and lactate biosensors were developed by using fluorescent dye and enzyme immobilized on the end tip of an optical fiber. 3-Glycidyloxypropyl)methyldiethoxysilane (GPTMS), (3-Aminopropyl) trimethoxysilane (APTMS) and Methyltrimethoxysilane (MTMS) were used to immobilize glucose oxidase (GOD), lactate oxidase (LOD) and ruthenium(II) complex (tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II), $Ru(dpp)_3^{2+}$) as oxygen sensitive fluorescent dye. MTMS sol-gel was an excellent supporting material for the immobilization of $Ru(dpp)_3^{2+}$, GOD, and LOD on the optical fiber. Storage stability of the optical fiber glucose sensor was kept constant over 20 days, while the optical fiber lactate sensor had constant storage stability over 17 days. The optical fiber glucose and lactate biosensors also maintained good operational stability for 20 hours and 14 hours, respectively. The activities of the immobilized enzymes were most excellent at pH 7 and at $25^{\circ}C$. On-line monitoring of glucose and lactate in a simulated process was performed with the optical fiber glucose and lactate biosensors. On-line monitoring results were agreed with those of off-line data measured with high performance liquid chromatography (HPLC).

형광검출기반 광학식 용존산소 측정센서 개발 및 특성 분석 (Development and Characterization of Optical Dissolved Oxygen Sensor based on the Fluorescence Detection)

  • 곽현민;권명회;최계운;정윤석;정창환;박규하;손옥재;김준형
    • 한국산학기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.569-574
    • /
    • 2014
  • 오폐수 처리에 있어서 용존산소량을 장기간, 연속측정이 가능한 DO 센서의 개발이 요구되어, 형광검출 특성을 이용한 광학식 DO 센서를 개발하고 특성을 분석하였다 (OS-100, 글로벌광통신주식회사). 형광 센서막은 GA를 이용하여 졸-겔 방법을 이용하여 $Ru(Dpp)_3{^{2+}}$(tris(4,7diphenyl-1, 10-phenanthroline) ruthenium(II)) 형광물질을 제작하였고, 용액과 혼합하여 스프레이 방법으로 석영기판위에 증착하였다. 증착된 형광막은 용존산소 농도 3 mg/L에서 10 mg/L 사이의 넓은 영역에서 ${\pm}1%$ 이하의 오차를 보였다. 제작된 광학식 DO 센서의 성능평가를 위하여 대구염색단지의 오폐수처리장 폐수의 실시간 용존산소를 장기간 측정하였다. 6개월간의 장기간에 걸쳐 실시간 측정된 용존산소의 결과는 염색공단 폐수의 악조건 하에서도 ${\pm}2%$ 이하의 오차를 나타내었다.

마이크로플레이트 기반 생물반응기 시스템 (MABOOMSTM)을 이용한 대장균 배양공정에서 용존산소, pH 및 세포농도의 온라인 모니터링 연구 (Study on Online Monitoring of Dissolved Oxygen, pH and Cell Concentration in E. coli Cultivation Processes Using MABOOMSTM)

  • 손옥재;이종일
    • KSBB Journal
    • /
    • 제28권1호
    • /
    • pp.24-30
    • /
    • 2013
  • Dissolved oxygen, pH and cell concentration have been online monitored in cultivation processes with Escherichia coli by using a $MABOOMS^{TM}$ (microplate-based bioreactor with optical online monitoring systems). Fluorescent sensing membranes containing Ru ${(dpp)_3}^{2+}$ or HPTS were prepared with GA sol-gel matrix and coated into a well of a 24-well microplate. Fluorescence intensity was measured and correlated to the dissolved oxygen or pH. Cell concentrations were also online monitored by measuring optical reflectance at 650 nm. A well of a 24-well microplate could also be divided into 4 parts, each of which was coated with fluorescent sensing membranes for the detection of dissolved oxygen or pH. The 24-well microplate coated with fluorescent sensing membranes or a 4-divided sensing membrane. was used to online monitor the dissolved oxygen, pH and cell concentration during E. coli cultivations. The online monitoring results showed the characteristics of cell growth in cultivation processes very well.