• Title/Summary/Keyword: $R_max$

Search Result 925, Processing Time 0.037 seconds

Development of shielding device for bremsstrahlung radiation from Y-90 microspheres (Y-90 microsphere 로부터 생성되는 제동복사선의 차폐를 위한 차폐체 개발 연구)

  • Park, Jun Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.50-53
    • /
    • 2019
  • Purpose Yttrium-90 (Y-90) is high-energy beta emitters ($E{\beta}$, max = 2.28 MeV) with the mean penetration depth of 2.5 mm in tissue. Radioactive microspheres containing Y-90 is widely used for the transarterial radioembolization of hepatocellular carcinoma. However, bremsstrahlung radiation from Y-90 can cause the external radiation exposure to medical staff who handle the Y-90 microspheres. In this study, shielding device for Y-90 microspheres was developed to minimize the external radiation exposure. Materials and Methods Y-90 microsphere shielding device was made from 6 mm thicknesses of tungsten including the lead glass window. Radiation shielding ability of Y-90 microsphere shielding device was evaluated using 4 GBq of $SIR-Spheres^{(R)}$ Y-90 microspheres. The bremsstrahlung radiation was measured using radiation survey meter. Results The mean radiation dose of Y-90 microspheres in acrylic shield was $261.7{\pm}2.3{\mu}Sv/h$ (n=5) at 10 cm away from the shield. With the additional tungsten shielding device, it was $23.7{\pm}1.3{\mu}Sv/h$ (n=5). Thus, the bremsstrahlung radiation dose was decreased by 90.9%. At 50 cm away from the shield, bremsstrahlung radiation was reduced by 89.2% after using tungsten shielding device. Conclusion During the preparation and radioembolization of Y-90 microsphere, medical staff are exposed to external radiation. In this study, we demonstrated that the use of tungsten shielding device devices significantly reduced the amount of bremsstrahlung radiation. Y-90 microsphere tungsten shielding device can be highly effective in reducing the bremsstrahlung radiation.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Molecular Properties of Excitation-Contraction Coupling Proteins in Infant and Adult Human Heart Tissues

  • Jung, Dai Hyun;Lee, Cheol Joo;Suh, Chang Kook;You, Hye Jin;Kim, Do Han
    • Molecules and Cells
    • /
    • v.20 no.1
    • /
    • pp.51-56
    • /
    • 2005
  • Excitation-contraction coupling (ECC) proteins in the human heart were characterized using human atrial tissues from different age groups. The samples were classified into one infant group (Group A: 0.2-7 years old) and three adult groups (Group B: 21-30; Group C: 41-49; Group D: 60-66). Whole homogenates (WH) of atrial tissues were assayed for ligand binding, $^{45}Ca^{2+}$ uptake and content of ECC proteins by Western blotting. Equilibrium [$^3H$]ryanodine binding to characterize the ryanodine receptor (RyR) of the sarcoplasmic reticulum (SR) showed that the maximal [$^3H$]ryanodine binding ($B_{max}$) to RyR was similar in all the age groups, but the dissociation constant ($k_d$) of ryanodine was higher in the infant group than the adult groups. Oxalate-supported $^{45}Ca^{2+}$ uptake into the SR, a function of the SR SERCA2a activity, was lower in the infant group than in the adult groups. Similarly, [$^3H$]PN200-110 binding, an index of dihydropyridine receptor (DHPR) density, was lower in the infant group. Expression of calsequestrin and triadin assessed by Western blotting was similar in the infant and adult groups, but junctin expression was considerably higher in the adult groups. These differences in key ECC proteins could underlie the different $Ca^{2+}$ handling properties and contractility of infant hearts.

Accelerated Degradation Stress of High Power Phosphor Converted LED Package (형광체 변환 고출력 백색 LED 패키지의 가속 열화 스트레스)

  • Chan, Sung-Il;Jang, Joong-Soon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.4
    • /
    • pp.19-26
    • /
    • 2010
  • We found that saturated water vapor pressure is the most dominant stress factor for the degradation phenomenon in the package for high-power phosphor-converted white light emitting diode (high power LED). Also, we proved that saturated water vapor pressure is effective acceleration stress of LED package degradation from an acceleration life test. Test conditions were $121^{\circ}C$, 100% R.H., and max. 168 h storage with and without 350 mA. The accelerating tests in both conditions cause optical power loss, reduction of spectrum intensity, device leakage current, and thermal resistance in the package. Also, dark brown color and pore induced by hygro-mechanical stress partially contribute to the degradation of LED package. From these results, we have known that the saturated water vapor pressure stress is adequate as the acceleration stress for shortening life test time of LED packages.

Regeneration of Plants from EMS-treated Immature Embryo Cultures in Soybean [Glycine max(L.) Merr.]

  • Van, Kyu-Jung;Jang, Hyun-Ju;Jang, Young-Eun;Lee, Suk-Ha
    • Journal of Crop Science and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.119-126
    • /
    • 2008
  • Since somatic embryogenesis combined with ethylmethane sulfonate(EMS) treatments is the most efficient technique for mutagenesis, the embryogenic capacity of four soybean cultivars was evaluated at different EMS concentrations, treatment times, and preculture durations. Two to 4 mm long immature cotyledons were placed in induction medium after EMS treatment, and the numbers of somatic embryos formed per explant were counted four weeks after culture initiation. We observed genotypic differences in the efficiency of somatic embryogenesis from immature embryos among four cultivars treated with different concentrations of EMS for six hours. Cultivars, Sinpaldalkong 2 and Jack, displayed highly efficient somatic embryogenesis regardless of EMS concentration, whereas very low efficiency or no survival was observed in Jinju 1 and Iksannamulkong cultivars. Preculture duration did not influence the efficiency of somatic embryogenesis. Because Sinpaldalkong 2 exhibited the best somatic embryogenesis, much higher concentrations of EMS were used to test somatic embryo formation under different periods of time in this cultivar. Three and six hour treatments with both 1 and 2 mM EMS yielded higher embryo formation than longer periods of time. Increasing the time with embryos in 2 mM EMS caused a reduction in somatic embryogenesis in Sinpaldalkong 2, but many chlorophyll-deficient soybean variants were identified in the $M_1R_0$ and $M_2R_1$ generations. In addition to Jack, Sinpaldalkong 2 is a good genotype for plant regeneration from EMS-treated immature embryo cultures.

  • PDF

Processing of an Intracellular Immature Pullulanase to the Mature Form Involves Enzymatic Activation and Stabilization in Alkaliphilic Bacillus sp. S-1

  • Lee, Moon-Jo;Kang, Bong-Seok;Kim, Dong-Soo;Kim, Yong-Tae;Kim, Se-Kwon;Chung, Kang-Hyun;Kim, Jume-Ki;Nam, Kyung-Soo;Lee, Young-Choon;Kim, Cheorl-Ho
    • BMB Reports
    • /
    • v.30 no.1
    • /
    • pp.46-54
    • /
    • 1997
  • Alkaliphilic Bacillus sp. S-1 secretes a large amount (approximately 80% of total pullulanase activity) of an extracellular pullulanase (PUL-E). The pullulanase exists in two forms: a precursor form (PUL-I: $M_r$ 180,000), and a processed form (PUL-E: $M_r$ 140,000). Two forms were purified to homogeneity and their properties were compared. PUL-I was different in molecular weight, isoelectric point, $NH_2$-terminal amino acid sequence, and stabilities over pH and temperature ranges. The catalytic activities of PUL-I were also distinguishable in the $K_m$ and $V_{max}$ values for various substrates, and in the specific activity for pullulan hydrolysis. PUL-E showed 10-fold higher specific activities than PUL-I. However. PUL-I is immunologically identical to PUL-E, suggesting that PUL-I is initially synthesized and proteolytically processed to the mature form of PUL-E. Processing was inhibited by PMSF, but not by pepstatin, suggesting that some intracellular serine proteases could be responsible for processing of the PUL-I. PUL-I has a different conformational structure for antibody recognition from that of PUL-E. It is also postulated that the translocation of alkaline pullulanase(AP) in the bacterium possibly requires processing of the $NH_2$-terminal region of the AP protein. Processing of the precursor involves a conformational shift. resulting in a mature form. Therefore. precursor processing not only cleaves the signal peptide, but also induces conformational shift. allowing development of active form of the enzyme.

  • PDF

Biokinetics of Protein Degrading Clostridium cadaveris and Clostridium sporogenes in Batch and Continuous Mode of Operations

  • Koo, Taewoan;Jannat, Md Abu Hanifa;Hwang, Seokhwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.4
    • /
    • pp.533-539
    • /
    • 2020
  • A quantitative real-time polymerase chain reaction (QPCR) was applied to estimate biokinetic coefficients of Clostridium cadaveris and Clostridium sporogenes, which utilize protein as carbon source. Experimental data on changes in peptone concentration and 16S rRNA gene copy numbers of C. cadaveris and C. sporogenes were fitted to model. The fourth-order Runge-Kutta approximation with non-linear least squares analysis was employed to solve the ordinary differential equations to estimate biokinetic coefficients. The maximum specific growth rate (μmax), half-saturation concentration (Ks), growth yield (Y), and decay coefficient (Kd) of C. cadaveris and C.sporogenes were 0.73 ± 0.05 and 1.35 ± 0.32 h-1, 6.07 ± 1.52 and 5.67 ± 1.53 g/l, 2.25 ± 0.75 × 1010 and 7.92 ± 3.71 × 109 copies/g, 0.002 ± 0.003 and 0.002 ± 0.001 h-1, respectively. The theoretical specific growth rate of C. sporogenes always exceeded that of C. cadaveris at peptone concentration higher than 3.62 g/l. When the influent peptone concentration was 5.0 g/l, the concentration of C.cadaveris gradually decreased to the steady value of 2.9 × 1010 copies/ml at 4 h Hydraulic retention time (HRT), which indicates a 67.1% reduction of the initial population, but the wash out occurred at HRTs of 1.9 and 3.2 h. The 16S rRNA gene copy numbers of C. sporogenes gradually decreased to steady values ranging from 1.1 × 1010 to 2.9 × 1010 copies/ml. C. sporogenes species was predicted to wash out at an HRT of 1.6 h.

Evaluating the Influence of Liquid Organic Polymer on Soil Aggregation and Growth of Perennial Ryegrass (유기중합물이 토양의 입단화와 페레니얼 라이그래스의 성장에 미치는 영향)

  • Lee, Sang-Kook;Minner, David
    • Asian Journal of Turfgrass Science
    • /
    • v.25 no.1
    • /
    • pp.69-72
    • /
    • 2011
  • Soil aggregate is a vigorous procedure including soil physical, chemical, and biological processes. Pore space created by binding these particles together improves retention and exchange of air and water. Various researches have reported that the benefits of organic polymers that may increase aggregate stability. The purpose of the study was to determine if a liquid organic polymer mixture has any influence on perennial ryegrass quality or soil aggregation. $Turf2Max^{(R)}$ was applied to two soils as a source of liquid organic polymer. Fine-loamy soil from local Iowa topsoil with 4.0% organic matter was screened and dried. Commercial baseball infield clay, $QuickDry^{(R)}$, was used as the second soil There were three rates of liquid organic polymer (0, 2, and 4%). there was no visual improvement in turf grass color, quality, or growth by using organic polymer. It is possible that aggregate stability increases with use of organic polymer. The aggregate stability study needs to be repeated in the greenhouse and then substantiated under field conditions for these preliminary observations.

A Study on Design of the Electrical Down Tilting Antenna with Shaped Beam Pattern (성형 빔 패턴을 갖는 전기적인 다운 틸팅 안테나의 설계에 관한 연구)

  • Lee Chang Eun;Hur Jung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.1
    • /
    • pp.111-118
    • /
    • 2005
  • The shape of vertical pattern of base station antenna affects greatly quality of the communication of not only a service zone but also adjacent cells and then it is an important point to be considered in designing cell coverage. Currently type of vertical patterns to be applied to base station antenna are divided into five classes. In designing antenna, these five classes are applied solely or compositely according to the environment to be used antenna. In this paper, the dual polarized antenna for base station that is with a continuous electrical down tilting and with a shaped beam pattern, that an upper side lobe is suppressed and a lower null is filled, is designed and fabricated for synthesizing of the shape beant the pattern synthesis methods proposed by R. S. Elliott is used sequentially and for the electrical don tilting, the phased array theory is applied. Measured results show the down tilting range from 0° to 14°, the gain of Min. 13.3dBi and the upper side lobe of Max. -23dB. And we verified that upper side lobe is not to vary greatly and null filling performance is favorable overall.

A study on characteristics of the autonomic nervous system in students with Keongke - Using Heart Rate Variability and Pupil Size Variability - (경계(驚悸) 증상을 지닌 학생 집단의 자율 신경 기능 특성에 대한 연구 - 심박변이도와 동공크기 변이도를 중심으로 -)

  • Lee, Seung-Gi;Lee, Jeong-Chan;Kim, Ji-Eun;Park, Kyung-Mo;Kang, Hee-Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.17 no.2
    • /
    • pp.133-145
    • /
    • 2006
  • Objective : The purpose of this experimental-controlled study was to investigate the characteristics of the autonomic nervous system in students with Keongke by using HRV(Heart rate variability) and PSV(Pupil size variability). Method : The study group was consisted of 11 students with self recognition as the experimental group, and 25 normal students as the control group. Informations on gender and age were obtained by medical charts and personal interviews. By using heart rate variability and pupil size variability, we measured the value of HRT(Heart rate), SDNN(Standard deviation of NN intervals), LFnorm(Low frequency normalization), HFnorm(High frequency normalization), LF/HF ratio, Pupil area, B.S.(Basic size), C.R.(Max Constriction Rate) and 1s.d.(1sec Dilation Rate). I compared the degrees of the sympathetic and parasympathetic activity. Result : 1. In the result of heart rate variability between experimental and control group, none of the parameters of experimental group were significantly different from control group. And even though there were no statistical significance, there were some numerical differences in SDNN, LF norm, HF norm. 2. In pupil size variability, C.R. and 1s.d. of the experimental group were increased compared to control group. Conclusion : The study results suggest that the group with Keongke has differences of autonomic nervous system as compared to those in normal state. Measurement value of PSV is a new technical approach to estimate the autonomic nervous system.

  • PDF