• 제목/요약/키워드: $Q_{10}$ coefficient

검색결과 382건 처리시간 0.021초

Accuracy Assessment of Global Land Cover Datasets in South Korea

  • Son, Sanghun;Kim, Jinsoo
    • 대한원격탐사학회지
    • /
    • 제34권4호
    • /
    • pp.601-610
    • /
    • 2018
  • The national accuracy of global land cover (GLC) products is of great importance to ecological and environmental research. However, GLC products that are derived from different satellite sensors, with differing spatial resolutions, classification methods, and classification schemes are certain to show some discrepancies. The goal of this study is to assess the accuracy of four commonly used GLC datasets in South Korea, GLC2000, GlobCover2009, MCD12Q1, and GlobeLand30. First, we compared the area of seven classes between four GLC datasets and a reference dataset. Then, we calculated the accuracy of the four GLC datasets based on an aggregated classification scheme containing seven classes, using overall, producer's and user's accuracies, and kappa coefficient. GlobeLand30 had the highest overall accuracy (77.59%). The overall accuracies of MCD12Q1, GLC2000, and GlobCover2009 were 75.51%, 68.38%, and 57.99%, respectively. These results indicate that GlobeLand30 is the most suitable dataset to support a variety of national scientific endeavors in South Korea.

Dynamic Magneto-mechanical Behavior of an Iron-nickel-based Ferromagnetic Alloy with Constant Elasticity

  • Bian, Leixiang;Wen, Yumei;Li, Ping;Gao, Qiuling;Liu, Xianxue
    • Journal of Magnetics
    • /
    • 제14권2호
    • /
    • pp.66-70
    • /
    • 2009
  • The dynamic magneto-mechanical behaviors in a type of iron-nickel-based ferromagnetic alloy with constant elasticity were investigated as a function of both the DC bias magnetic field ($H_{dc}$) and the frequency. The rectangular plate-like samples were excited to vibrate at a half-wavelength, longitudinal resonance by an AC magnetic field superimposed with various $H_{dc}$. The experimental results found that the strain coefficient at resonance reached 819.34 nm/A and the effective mechanical quality factor ($Q_m$) was greater than 2000. The ratio of the maximum variation of the Young's modulus over $H_{dc}$ to the value of the Young's modulus at a zero bias field was only ${\sim}0.83%o$ because of the so-called constant elasticity. The resonant strain coefficients and $Q_m$ are strongly dependent on $H_{dc}$, which indicates a promising potential for use in DC and quasistatic magnetic field sensing.

(1-x)ZnWO4-xTiO2 세라믹스의 마이크로파 유전특성 (Microwave Dielectric Properties of (1-x)ZnWO4-xTiO2 Ceramics)

  • 윤상옥;김대민;심상흥;강기성
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.397-403
    • /
    • 2003
  • Microwave dielectric properties of (1-x)ZnW $O_4$-xTi $O_2$ ceramic systems were investigated with calcination temperatures and Ti $O_2$ contents. The ZnW $O_4$ ceramic could be suitably sintered at 1075$^{\circ}C$ and showed the dielectric constant of 13.6, quality factor(Q$\times$ $f_{O}$value) of 22,000 and temperature coefficient of resonant frequency($\tau$$_{f}$) of -65$\pm$2ppm/$^{\circ}C$. Increasing the amount of Ti $O_2$ in the range of 0.25 to 0.45 mol, the dielectric constant and $\tau$$_{f}$ increased due to the role of Ti $O_2$ but the quality factor decreased due to the increase of phase boundaries. The 0.7ZnW $O_4$-0.3Ti $O_2$ ceramic showed the dielectric constant of 19.8, qualify factor(Q$\times$ $f_{0}$) of 20,000 and $\tau$$_{f}$ of -3$\pm$1ppm/$^{\circ}C$.>.EX>.>.>.

A Study on the Compensation of the Inductance Parameters of Interior Permanent-Magnet Synchronous Motors Affected by the Magnet Size

  • Jang, Ik-Sang;Lee, Hyung-Woo;Kim, Won-Ho;Cho, Su-Yeon;Kim, Mi-Jung;Lee, Ki-Doek;Lee, Ju
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.74-76
    • /
    • 2011
  • Interior permanent-magnet synchronous motors (IPMSMs) produce both magnetic and reluctance torques. The reluctance torque is due to the difference between the d- and q-axis inductances based on the geometric rotor structure. The steady-state performance analysis and precise control of the IPMSMs greatly depend on the accurate determination of the parameters. The three essential parameters of the IPMSMs are the armature flux linkage of the permanent magnet, the d-axis inductance, and the q-axis inductance. In the basic design step of an IPMSM, the inductance parameters are very important for determining the motor characteristics, such as the input voltage, torque, and efficiency. Thus, it is very important to accurately estimate the values of the motor inductances. The inductance parameters of IPMSMs have nonlinear characteristics along the magnet size because the iron core is saturated by the magnet and armature reaction fluxes. In this study, the inductance parameters were calculated using both the magnetic-equivalent-circuit method and the finite-element method (FEM). Then the calculated parameters were compensated by the saturation coefficient function, which was also calculated via the magnetic-equivalent-circuit method and FEM.

무선 전력 전송용 High-Q 스파이럴 영차 공진기 (High-Q Spiral Zeroth-Order Resonators for Wireless Power Transmission)

  • 박병철;박재현;이정해
    • 한국전자파학회논문지
    • /
    • 제23권3호
    • /
    • pp.343-354
    • /
    • 2012
  • 본 논문에서는 무선 전력 전송을 위한 다양한 스파이럴 구조의 영자 공진기들을 설계하였다. 메타 물질 전송 선로의 영차 공진은 무한 파장의 특징을 가지기 때문에 공진기의 크기에 상관없이 디자인이 가능한 장점을 가진다. 또한, 무선 전력 전송에서 고효율의 전송 효율을 얻기 위해서는 공진기의 Q-factor와 공진기간의 결합 계수가 커야 한다. 따라서 제안된 영차 공진기들은 영차 공진을 유도하기 위해 스파이럴 형태의 인덕터와 집중 캐패시터 소자를 사용하였고, parametric study와 R, L, C 회로 분석을 통해 높은 Q-factor를 얻기 위한 최적의 디자인을 찾고자 하였다. 최적화된 공진기들은 기존의 스파이럴 공진기와 모의 실험을 통해 비교되었으며, 최적화된 공진기들 중 제작된 공진기의 크기는 $20cm{\times}20cm{\times}8cm$($0.009{\lambda}_0{\times}0.009{\lambda}_0{\times}0.004{\lambda}_0$)이고, 13.56 MHz 대역의 주파수와 40 cm 거리에서 80 %의 전송 효율이 측정되었다.

ON THE SCALED INVERSE OF (xi - xj) MODULO CYCLOTOMIC POLYNOMIAL OF THE FORM Φps (x) OR Φpsqt (x)

  • Cheon, Jung Hee;Kim, Dongwoo;Kim, Duhyeong;Lee, Keewoo
    • 대한수학회지
    • /
    • 제59권3호
    • /
    • pp.621-634
    • /
    • 2022
  • The scaled inverse of a nonzero element a(x) ∈ ℤ[x]/f(x), where f(x) is an irreducible polynomial over ℤ, is the element b(x) ∈ ℤ[x]/f(x) such that a(x)b(x) = c (mod f(x)) for the smallest possible positive integer scale c. In this paper, we investigate the scaled inverse of (xi - xj) modulo cyclotomic polynomial of the form Φps (x) or Φpsqt (x), where p, q are primes with p < q and s, t are positive integers. Our main results are that the coefficient size of the scaled inverse of (xi - xj) is bounded by p - 1 with the scale p modulo Φps (x), and is bounded by q - 1 with the scale not greater than q modulo Φpsqt (x). Previously, the analogous result on cyclotomic polynomials of the form Φ2n (x) gave rise to many lattice-based cryptosystems, especially, zero-knowledge proofs. Our result provides more flexible choice of cyclotomic polynomials in such cryptosystems. Along the way of proving the theorems, we also prove several properties of {xk}k∈ℤ in ℤ[x]/Φpq(x) which might be of independent interest.

건강기능식품에서 LC-MS/MS를 이용한 코엔자임Q10 분석법 연구 (Analytical Method Development for Determination of Coenzyme Q10 by LC-MS/MS in Related Health Functional Foods)

  • 이진희;오미현
    • 한국식품위생안전성학회지
    • /
    • 제34권6호
    • /
    • pp.519-525
    • /
    • 2019
  • 건강기능식품의 경우 단성분보다는 복합제품 개발이 우선시되고, 12가지 기본제형이외에도 일반식품형태의 제품으로 범위가 확대되고 있다. 이러한 제품에서 기능성(지표)성분을 효율적으로 분석할 수 있는 방법에 대한 연구가 필요한 실정이다. 복합제품 등에서 정성·정량 가능한 코엔자임Q10을 효과적으로 분석할 수 방법을 확립하기 위하여 본 연구를 수행하였다. 액체크로마토그라프-질량분석기(LC-MS/MS)를 이용하여 건강기능식품 중 코엔자임Q10의 정성·정량시험법을 확립하였다. 확립된 시험법에 대해 특이성, 검출한계, 정량한계, 정확도, 정밀도에 대한 검증을 통하여 유효성을 확인하였다. 또한 시중 유통검체 14건을 확보하여 시험의 적용가능성도 검토하였다. 직선성에서는 R2>0.999 이상임을 확인하였고, 검출한계 및 정량한계는 각각 26.0 및 78.9 ㎍/L이었다. 또한 평균 회수율은 98.6-107.0%로 나타났으며, 반복정밀도는 상대표준편차 4.0%이하, 실험실간 재현성은 2.4%로 나타나 정확성, 재현성이 우수하였으며 이는 AOAC 가이드라인에서 제시한 기준에 모두 적합한 수준이었다. 시중 유통 제품에 대하여 실험한 결과 84.0-118.7%로 모두 적합하였다. 따라서 본 연구에서 개발된 분석법은 건강기능식품 중 코엔자임Q10의 정성·정량분석에 이용될 수 있으며, 우수한 품질의 건강기능식품유통에 기여할 것으로 판단된다.

Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model

  • Xuee Zhu;Jichen Wang;Dan Zhou;Chong Feng;Zhiwen Dong;Hanxiao Yu
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.641-648
    • /
    • 2019
  • Objective: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption. Materials and Methods: We used 20 freshly harvested goat spine samples with 60 segments and intact surrounding soft tissue. The animals were aged 1-1.5 years and consisted of 8 males and 12 females, which were sexually mature but had not reached adult weights. We created a paraspinal contusion model by percutaneously injecting 10 mL saline into each side of the interspinous ligament (ISL). All segments underwent T2-weighted sagittal and coronal short inversion time inversion recovery (STIR) scans as well as coronal and sagittal 3D proton density-weighted spectrally selective inversion recovery (3D-PDW-SPIR) scans acquired at 1.5T. Following scanning, some ISLs were cut and then the segments were rescanned using the same magnetic resonance (MR) techniques. Two radiologists independently assessed the MR images, and the reliability of ISL tear interpretation was assessed using the kappa coefficient. The chi-square test was used to compare the diagnostic accuracy of images obtained using the different MR techniques. Results: The interobserver reliability for detecting ISL disruption was high for all imaging techniques (0.776-0.949). The sensitivity, specificity, and diagnostic accuracy of the coronal 3D-PDW-SPIR technique for detecting ISL tears were 100, 96.9, and 97.9%, respectively, which were significantly higher than those of the sagittal STIR (p = 0.000), coronal STIR (p = 0.000), and sagittal 3D-PDW-SPIR (p = 0.001) techniques. Conclusion: Compared to other MR methods, coronal 3D-PDW-SPIR provides a more accurate diagnosis of ISL disruption. Adding coronal 3D-PDW-SPIR to a routine MR protocol may help to identify PLC disruptions in cases with nearby contusion.

간호대학생의 KCUE-Q1(Korean College & University Education Questionnaire)에 따른 비인지적 학습성과 (Affective Outcome According to KCUE-Q1(Korean College and University Education Questionnaire) in Nursing Students)

  • 김옥현;최은주
    • 한국콘텐츠학회논문지
    • /
    • 제14권10호
    • /
    • pp.862-872
    • /
    • 2014
  • 본 연구의 목적은 대학의 특성을 반영하고 비용 면에서 경제적이며 간편한 KCUE-Q1을 활용하여 간호학생의 비인지적 학습성과 수준을 파악하기 위함이다. 본 연구는 2013년 12월 2일부터 12월 20일까지 4개교의 전문대학 졸업예정자인 3, 4학년 간호대학생 중 연구목적을 이해하고 참여에 동의한 424명을 연구대상으로 편의표집하였다. 연구 결과 간호대학생의 비인지적 학습성과 성취수준은 평균 2.69점이었으며, 대상자의 일반적 특성 중 성별, 학년, 소속 대학의 2주기 간호교육 인증평가 및 동아리 활동에 따라 통계적으로 유의한 차이가 있었다. 또한 학습열의가 높을수록 학습경험이 높아지고 교육성과도 높은 것으로 나타났다. 따라서 간호학 전공 학생들의 학습성과 향상을 위한 전략으로 교육과정과 비교과활동을 통합할 수 있는 프로그램 개발 및 운영이 필요하며, 이는 간호대학생의 간호학 학습성과 성취수준 향상에 기여할 수 있으리라 생각된다.

다목적 PSO 알고리즘을 활용한 SWAT의 자동보정 적용성 평가 (Evaluation of multi-objective PSO algorithm for SWAT auto-calibration)

  • 장원진;이용관;김성준
    • 한국수자원학회논문집
    • /
    • 제51권9호
    • /
    • pp.803-812
    • /
    • 2018
  • 본 연구는 다목적함수를 고려한 입자군집최적화(Particle Swarm Optimization, PSO) 알고리즘을 Python으로 개발하고, Soil and Water Assessment Tool (SWAT) 모형에 적용하여 자동보정 알고리즘의 적용 가능성을 평가하였다. SWAT 모형의 유출 해석은 안성천의 공도 수위 관측소 상류유역($364.8km^2$)을 대상으로 하였으며, 공도 지점의 2000년부터 2015년까지의 일 유량 자료를 이용하였다. PSO 자동보정은 결정계수(coefficient of determination, $R^2$), 평균제곱근오차(RMSE), NSE 모형효율계수(Nash-Sutcliffe Efficiency, $NSE_Q$), 특히 중간유출과 기저유출의 보정을 위해 $NSE_{INQ}$ (Inverse Q)를 활용하여 SWAT을 보정하였다. PSO을 통한 SWAT 모형의 자동보정과 수동보정의 유출해석 결과, 각각 $R^2$는 0.64, 0.55, RMSE는 0.59, 0.58, $NSE_Q$는 0.78, 0.75, $NSE_{INQ}$는 0.45, 0.09의 상관성 분석결과를 보였다. PSO 자동보정 알고리즘은 수동보정에 비하여 높은 향상을 보였는데 특히 유출의 감수곡선을 개선시켰으며 적절한 매개변수 추가(RCHRG_DP)와 매개변수 범위의 설정으로 수동보정의 한계를 보완하였다.