• Title/Summary/Keyword: $PaO_2$

Search Result 515, Processing Time 0.03 seconds

The Etching Characteristics of $TiO_2$ ThinFilms Using the Inductively Coupled Plasma (유도 결합 플라즈마를 이용한 $TiO_2$ 박막의 식각 특성)

  • Joo, Young-Hee;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.385-385
    • /
    • 2010
  • In this work, we have investigated the etching characteristics of $TiO_2$ and selectivity of $TiO_2$ over $SiO_2$ thin films as resistance in ReRAM using the inductively coupled plasma. The etch rate and selectivity were measured by varying the $BCl_3$ addition into Ar plasma. The maximum etchrate was obtained at 110.1nm/min at $BCl_3$/Ar=5sccm/10sccm, 500W for RFpower, -100v for DC-bias voltage, and 2Pa for the process pressure. The etched $TiO_2$ surface was investigated with X-ray photo electron spectroscopy. We explained the etching mechanism in two etch mechanisms, physiclas puttering and chemical reaction.

  • PDF

Development of Protein Delivery System using Pullulan Acetate Microspheres (PAM) (플루란 아세테이트 미립구를 이용한 단백질 전달 시스템 개발)

  • Na, Kun;Choi, Hoo-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.115-121
    • /
    • 2006
  • The aim of this study was to develop new protein/peptide depot system instead of poly(DL-lactic acid-coglycolic acid) (PLGA) microspheres. Pullulan was chemically modified by the addition of acetic anhydride (pullulan acetate; PA) and then investigated as new depot system for protein/peptide delivery. PA microspheres (PAM) with lysozyme as a model protein were prepared by w/o/w double emulsion method. The microspheres had a mean size of 10-50 mm with a spherical shape. The size distributions reduced with increasing the degree of acetylation. The loading efficiency of lysozyme was also increased. Lysozyme aggregation behavior in the microsphere was monitored to estimate the change of protein stability during preparation step. The ratios of protein aggregation in PAMs are lower than that of PLGA microsphere, in particular, PA 5 showed lowest as about 16%. The result indicated that the increase of acetylation suppressed the aggregation of protein. The release profiles of lysozyme from PAMs were significantly different. High acetylation effectively improved lysozyme release kinetics by reducing initial burst release and extending continuous release over a period of time. To check the effect of preservation for structural stability of lysozyme, the activity of lysozyme released from PA 5 was also observed. The activity of lysozyme was maintained almost 100% for 25 day. Therefore, PAM may become to a useful carrier for delivery of protein/peptide drugs, if it will be supported by biocompatibility and biodegradability results.

Pool Boiling Performance of Enhanced Tubes for the Generator of an Absorption Chiller (흡수식 냉동기 재생기용 고성능 전열관의 풀비등 성능)

  • Sim, Yong-Sub;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1684-1691
    • /
    • 2015
  • For performance improvement and compactness, usage of enhanced tube is inevitable. However, studies on enhanced tubes for generator is very limited. In this study, pool boiling tests were conducted for 7 heat transfer tubes. Test range covered pressure 7.38~101.3 kPa and heat flux $20{\sim}40kW/m^2$. Results show that boiling heat transfer coefficient increases as pressure or heat flux increases. Under atmospheric condition, high heat transfer coefficients were obtained for notched fin and low fin tubes(225% and 202% of the 19.0 mm smooth tube, which yielded the lowest heat transfer coefficient). As pressure decreased, high heat transfer coefficients were obtained for a low fin tube(290% and 288% of the 19.0 mm smooth tube at 12.34 and 7.38 kPa).

Enhancing the Reproducibility of a Photoacoustic Signal Using a Minimum-volume Cell (최소 부피 광음향 셀의 광음향 신호 재현성 향상에 관한 연구)

  • Kim, Kyong-Seok;Lee, Kew-Seung;Ahn, Hong-Gyu;Lee, Eung-Jang;Kim, Dae-Kyu;Park, Seung-Han
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.2
    • /
    • pp.77-82
    • /
    • 2011
  • Reproducibility obtained by a minimum-volume cell for photoacoustic (PA) signals is strongly dependent upon the sealing materials and sealing efficiency. Therefore, we have proposed, designed, and constructed an apparatus to enhance the sealing efficiency, and we have examined the reproducibility of amplitude and phase of PA signals with a minimum-volume cell. In particular, we have measured the PA signal as a function of modulation frequency for various rubber O-rings by using our apparatus. The results show that a silicon rubber O-ring can improve the reproducibility of the PA signal and phase by up to 53.4% and 80.4%, respectively, compared to that obtained by using the conventional sealing material, vacuum grease.

Preparation and Permeation of La2Ce2O7 Membrane

  • Park, Jihye;Jung, Miewon
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.4
    • /
    • pp.269-272
    • /
    • 2015
  • $La_2Ce_2O_7$ and $CeO_2$ membranes were fabricated from the corresponding powders derived from sol-gel process with polyvinyl alcohol binder. These powders and membranes were characterized by XRD, BET, and FE-SEM analysis. Hydrogen and CO gas permeation experiments were performed using Sievert's type equipment. Both fluxes on these membranes were found to decrease with increase of the temperature. This phenomenon was followed by the surface and Knudsen diffusion mechanism. The hydrogen permeability of the $La_2Ce_2O_7$ membrane was found to be $7.27{\times}10^{-5}mol/m^2sPa$, with perm-selectivity of 7.24 at 303 K.

Rebound Pulmonary Hypertension After Nitric Oxide Withdrawal (산화질수(Nitric Oxide) 중단 후의 반동성폐고혈압)

  • 이현우;이재웅;현성열;박철현;박국양;이경천
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.132-138
    • /
    • 2000
  • Background: Inhaled nitric oxide therapy causes selective pulmonary vasodilation in congenital heart diseases with pulmonary hypertension. However discontinuation of inhaled nitric oxide therapy may be complicated by abrupt life-threatening rebound pulmonary hypertension(RPH) The purpose of this study was to prevent by comparing group I(without RPH n=13) and group II(with RPH n=6) to determine the risk factors involved inthe development of the RPH. Material and Method: Between Januarty 6, 1998 and April 14, 1999. we studied 19 consecutive children who were treated with inhaled nitric oxide for clinically significant pulmonary hypertension after an open heart surgery for congenital heart disease. the ratio of males and females was 12:7 ranging in age from 10 days to 6040 days(16 years) To identify the effects of nitric oxide between two groups we measured heart rate mean and systolic pulmonary arterial pressure mean and systolic systemic arterial pressure central venous pressure pH paO2/FiO2 and O2 saturation before and after the initiation and just before the withdrawal of the inhaled nitric oxide. result: In 6 of 19 patients(32%) withdrawal of inhaled nitric oxide caused RPH. In the two groups inhaled nitrix oxide decreased in pulmonary arterial pressure(PAP) without decreasing the systemic arterial pressure(SAP) and increased PaO2/FiO2 Compared with patients who had no RPH(group I) patients who had RPH(group II) were older in age (1204$\pm$1688 versus 546$\pm$1654 days p<0.05) received less nitric oxide therapy(34$\pm$18 versus 67$\pm$46 hours p<0.05) has shorter weaning process(5$\pm$3 versus 15一13 hours p<0.05) and received lowerconcentration of initial nitric oxide supply(11$\pm$8 versus 17$\pm$8 ppm p>0.05) and lower concentration just before the withdrawal nitric oxide(4.2$\pm$2.6 versus 5.6$\pm$2.6 ppm, p>0.05) Conclusion : We speculate that older age shorter of nitric oxide therapy shorter weaning process are the risk factors of RPH.

  • PDF

Synthesis and Application of Nanoparticulate Aluminosilicate Sols (II) Mixed Al_2O_3-SiO_2$ Sols (극미세 입자 Aluminosilicate계 졸의 합성 및 응용 (II) Al_2O_3-SiO_2$계 혼합졸)

  • 현상훈;김승구;이성철
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.1
    • /
    • pp.63-70
    • /
    • 1995
  • A crack-free ceramic composite membrane with micropores has been synthesized by the pressurized sol-gel coating technique using the mixed Al2O3-SiO2 sols. The mixed sols were prepared by mixing nanoparticulate SiO2 and boehmite sols. These sols were more stable at lower pH, but very unstable when their copositions were in the range of 50~75mol% of SiO2 at the same pH. The mixed Al2O3-SiO2 membrane prepared from the mixed sol (0.2mol/$\ell$ of solid content and pH=2) containing 40mol% of SiO2 had the mean pore radius of 0.80nm and the specific surface area of 280$m^2$/g. The nitrogen permeability through the coated Al2O3-SiO2 layer was 42$\times$107mol/$m^2$.s.Pa. It was found that the thermal stability of aluminosilicate membranes, even through similar to that of SiO2 membranes, was much improved in comparison with ${\gamma}$-alumina membranes.

  • PDF

Disappearance of Hypoxic Pulmonary Vasoconstriction and $O_2$-Sensitive Nonselective Cationic Current in Arterial Myocytes of Rats Under Ambient Hypoxia

  • Yoo, Hae Young;Kim, Sung Joon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.5
    • /
    • pp.463-468
    • /
    • 2013
  • Acute hypoxia induces contraction of pulmonary artery (PA) to protect ventilation/perfusion mismatch in lungs. As for the cellular mechanism of hypoxic pulmonary vasoconstriction (HPV), hypoxic inhibition of voltage-gated $K^+$ channel (Kv) in PA smooth muscle cell (PASMC) has been suggested. In addition, our recent study showed that thromboxane $A_2$ ($TXA_2$) and hypoxia-activated nonselective cation channel ($I_{NSC}$) is also essential for HPV. However, it is not well understood whether HPV is maintained in the animals exposed to ambient hypoxia for two days (2d-H). Specifically, the associated electrophysiological changes in PASMCs have not been studied. Here we investigate the effects of 2d-H on HPV in isolated ventilated/perfused lungs (V/P lungs) from rats. HPV was almost abolished without structural remodeling of PA in 2d-H rats, and the lost HPV was not recovered by Kv inhibitor, 4-aminopyridine. Patch clamp study showed that the hypoxic inhibition of Kv current in PASMC was similar between 2d-H and control. In contrast, hypoxia and $TXA_2$-activated $I_{NSC}$ was not observed in PASMCs of 2d-H. From above results, it is suggested that the decreased $I_{NSC}$ might be the primary functional cause of HPV disappearance in the relatively early period (2 d) of hypoxia.

The Effect of Hypocarbic Priming Solutions on Extracorporeal Circulation during Open Heart Surgery (개심술시 충전액의 저이산화탄소 분압이 체외순환에 미치는 영향)

  • Song, Sun-Ok;Suh, Jung-Kook;Kim, Heung-Dae
    • Journal of Yeungnam Medical Science
    • /
    • v.1 no.1
    • /
    • pp.101-106
    • /
    • 1984
  • Before beginning the extracorporeal circulation, perfusionists should supply oxygen into the oxygenator and establish blood flow through the blood line of the heart-lung machine. But these manipulation can induce severe hypocarbic state of priming solutions due to wash out of $CO_2$ gas in the solution. This study was carried out to examine the relationship of blood gas changes between hypocarbic priming solutions and body circulation in 15 patients undergoing open heart surgery with extracorporeal circulation. $PaCO_2$, pH, buffer base and $PaO_2$ were measured from priming solutions before and 15 minutes after the extracorporeal circulation. The results were as follows; 1) Before the extracorporeal circulation, mean $PaCO_2$ level was $12.1{\pm}7.8mmHg$ in the priming solution. However, 15 minutes after extracorporeal circulation, the $PaCO_2$ level was maintained at $35.7{\pm}5.7mmHg$. 2) pH in the priming solution was variable from 6.93 to 7.99 (mean $7.45{\pm}0.29$), but after 15 minutes it was ranged from 7.28 to 7.42 (mean $7.35{\pm}0.05$). 3) Mean buffer base level in the priming solution was $7.9{\pm}3.5mmol/l$, but after 15 minutes, it was $19.6{\pm}1.2mmol/l$. 4) Mean $PaO_2$ level in the priming solution was $667.1{\pm}45.6mmHg$, but after 15 minutes, it was $280.7{\pm}131.7mmHg$.

  • PDF

The Fabrication and Electrical Properties of PMS-PZT Ceramics using a Tape Casting Method (Tape Casting법에 의한 PMS-PZT계 세라믹스 제조 및 전기적 특성)

  • Jung, Hyun-Jae;Na, Eun-Sang;Choi, Sung-Churl
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.9
    • /
    • pp.860-865
    • /
    • 2001
  • After manufacturing 2mol% CdO substitute $0.05Pb(Mn_{1/3}Sb_{2/3})O_3-0.95Pb(Zr_{0.52}Ti_{0.48})O_3$ piezoelectric ceramics powder as starting material, to manufacture green sheets using Doctor Blade method. The optimum composition of slurry was studied. Moreover, the sintering properties and the dielectric and piezoelectric properties with variation a thickness of the manufactured sheets were investigated. The optimum of slurry was investigated by the rheology with addition of additives, the sintering condition was decided by TGA. And the properties of sheet were investigated through SEM. XRD. The optimum of slurry was the stablest at dispersant 3.0 wt% to solid loading 30vol%. After, at addition of binder/plasticizer(0.75/0.25) 3.0wt%, viscosity was 7.55Pa${\cdot}$s. The dielectric and piezoelectric properties of the sheet were increased a little with the increasing of sintering temperature but were not variable with variation of sheet thickness.

  • PDF