• Title/Summary/Keyword: $PM_10$

검색결과 22,838건 처리시간 0.049초

PSCF 모델을 활용한 부산지역 PM10의 발생원 추정 (Estimation of PM10 source locations in Busan using PSCF model)

  • 도우곤;정우식
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.793-806
    • /
    • 2015
  • The purpose of this study is to find out the air flow patterns affecting the PM10 concentration in Busan and the potential sources within each trajectory pattern. The synoptic air flow trajectories are classified into four clusters by HYSPLIT model and the potential sources of PM10 are estimated by PSCF model for each cluster from 2008 to 2012. The potential source locations of PM10 are compared with the distribution of PM10 anthropogenic emissions in east Asia developed in 2006 for the NASA INTEX-B mission. The annual mean concentrations of PM10 in Busan decreased from $51ug/m^3$ in 2008 to $43ug/m^3$ in 2012. The monthly mean concentrations of PM10 were high during a spring season, March to May and low during a summer season, August and September. The cluster2 composed of the air trajectories from the eastern China to Busan through the west sea showed the highest frequency, 44 %. The cluster1 composed of the air trajectories from the inner Mongolia region to Busan through the northeast area of China showed the second high frequency, 26 %. The cluster3 and 4 were composed of the trajectories originated in the southeast sea and the east sea of Busan respectively and showed low frequencies. The concentrations of in each cluster were $47ug/m^3$ in cluster1, $56ug/m^3$ in cluster2, $42ug/m^3$ in cluster3 and $37ug/m^3$ in cluster4. From these results, it was proved that the cluster1 and 2 composed of the trajectories originated in the east and northeast area of China were the causes of high PM10 concentrations in Busan. The results of PSCF and CWT model showed that the potential sources of the high PM10 concentrations were the areas of the around Mongolia and the eastern China having high emissions of PM10 from Beijing, Hebei to Shanghai through Shandong, Jiangsu.

부산지역 미세먼지에 대한 건강 취약성 평가 (Health Vulnerability Assessment for PM10 in Busan)

  • 이원정;황미경;김유근
    • 한국환경보건학회지
    • /
    • 제40권5호
    • /
    • pp.355-366
    • /
    • 2014
  • Objectives: This study seeks to evaluate the vulnerability assessment of the human health sector for $PM_{10}$, which is reflected in the regional characteristics and related disease mortality rates for $PM_{10}$ in Busan over the period of 2006-2010. Methods: According to the vulnerability concept suggested by the Intergovernmental Panel on Climate Change (IPCC), vulnerability to $PM_{10}$ is comprised of the categories of exposure, sensitivity, and adaptive capacity. The indexes of the exposure and sensitivity categories indicate positive effects, while the adaptive capacity index indicates a negative effect on vulnerability to $PM_{10}$. Variables of each category were standardized by the rescaling method, and each regional relative vulnerability was computed through the vulnerability index calculation formula. Results: The regions with a high exposure index are Jung-Gu (transportation region) and Saha-Gu (industrial region). Major factors determining the exposure index are the $PM_{10}$ concentration, days of $PM_{10}{\geq}50$, ${\mu}g/m^3$, and $PM_{10}$ emissions. The regions that show a high sensitivity index are urban and rural regions; these commonly have a high mortality rate for related disease and vulnerable populations. The regions that have a high adaptive capacity index are Jung-Gu, Gangseo-Gu, and Busanjin-Gu, all of which have a high level of economic/welfare/health care factors. The high-vulnerability synthesis of the exposure, sensitivity, and adaptive capacity indexes show that Dong-Gu and Seo-Gu have a risk for $PM_{10}$ potential effects and a low adaptive capacity. Conclusions: This study presents the vulnerability index to $PM_{10}$ through a relative comparison using quantitative evaluation to draw regional priorities. Therefore, it provides basic data to reflect environmental health influences in favor of an adaptive policy limiting damage to human health caused by vulnerability to $PM_{10}$.

A Study on the Status of Antioxidant Vitamins and Serum Lipids in Korean Adults

  • Jang, Hyun-Suk;An, Kyung-Choon;Kwon, Chong-Suk
    • Preventive Nutrition and Food Science
    • /
    • 제4권1호
    • /
    • pp.62-69
    • /
    • 1999
  • The present study was aimed at investigating whether there are sex-related differences in serum levels of lipids, retinol , $\alpha$-tocopherol and ascorbic acid in Korean adults. Serum levels of antioxidant vitamins and lipids were determined algon with anthropometric measurements in 53 healthy male subjects with mean age 42.7$\pm$12.2 years and 44 female subjects with mean age 46.7$\pm$10.3 years. from Taegu in Korea. BMI and W/H ration of the men were 22.66$\pm$2.47, 0.88$\pm$0.04 and those fo thewomen were 23.36$\pm$3.44, 0.84$\pm$0.05 respectively. Systolic and diastolic blood pressures were 121.67$\pm$14.8, 79.3$\pm$12.4 in the men and 123.1 $\pm$17.5 , 78.8$\pm$10.9 in the women respectively. Average serum levels of total cholesterol, LDL-and HDL-cholesterol and triglyceride were 165.8$\pm$36.4, 102.6$\pm$31.2, 41.1$\pm$10.5 and 110.2$\pm$57.8mg/dl in the and 169.1$\pm$39.1, 113.7$\pm$36.2, 38.1 $\pm$8.6, and 85.2$\pm$37.7mg/dl in the women respectively. Thirteen percent of menans thirtyeight percent of women had LDL-cholesterol over 130mg/dl. Serum levels of retinol, $\alpha$tocopherol, ad ascorbic acid were 43.25 $\pm$15.51, 17.93$\pm$7.07, 115.24$\pm$63.25ug/dl in the men and 31.80$\pm$15.39, 17.41$\pm$6.12, an d144.99$\pm$89.87ug/dl in the women respectively. Serum vitamin E showed positive correlations with total cholesterol and LDL-cholesterol and triglyceride.

  • PDF

진주지역 시정과 미세먼지(PM10) 농도와의 상관관계 (A Correlation Analysis between Visibility and PM10 in Jinju)

  • 김형갑;서정민;박정호
    • 한국환경과학회지
    • /
    • 제26권4호
    • /
    • pp.535-542
    • /
    • 2017
  • This study was conducted to investigate how $PM_{10}$ concentration and Relative Humidity (RH) affected visibility in Jinju, Korea. A 9-yr dataset of 1 h averages for visibility, $PM_{10}$, and RH data was analyzed to examine the correlation between these variables. On average, visibility decreased by 1.4 km for every $10{\mu}g/m^3$ increase in $PM_{10}$ and by 2.1 km for every 10% increase in RH. In general, a negative correlation was observed between visibility and and $PM_{10}$ concentration. However, under conditions of low $PM_{10}$ concentration(< $15{\mu}g/m^3$) and visibility(< 2 km), there was a positive correlation between these two variables. In this case, RH levels were high (> 75%). A high correlation analysis between two variables need to be under control conditions with RH < 75%, $PM_{10}$ $15{\sim}100{\mu}g/m^3$, and visibility > 2 km.

서울.아산지역 호흡성먼지의 금속함량에 관한 연구 (Comparison of Metal Contents in Respirable Particulate Mass by Particle Size and Season in Seoul and Asan City)

  • 최윤나;전용택;장봉기;양원호;염윤기;손부순
    • 환경위생공학
    • /
    • 제23권1호
    • /
    • pp.33-48
    • /
    • 2008
  • The purpose of this study was to characterize background mass concentration of $PM_{10},\;PM_{2.5}$ and metallic composition from June 2004 to June 2005 in comparison with Seoul and Asan city. The results were as follows: 1. Annual mean of $PM_{10}$ concentrations in Seoul and Asan were $56.95({\pm}25.63){\mu}g/m^3,\;57.02({\pm}27.22){\mu}g/m^3$ respectly. 2. Annual mean of $PM_{2.5}$ concentrations in Seoul and Asan were $46.97({\pm}40.36){\mu}g/m^3,\;42.16({\pm}21.79){\mu}g/m^3$ respectly. 3. The average $PM_{2.5}/PM_{10}$ ratio was 0.82 in Seoul and 0.74 in Asan city. 4. The concentration of $PM_{10},\;PM_{2.5}$ were the highest in spring and the lowest in summer. Asan was higher than Seoul in spring and summer. 5. The results showed that average $PM_{10}$ composition order as Si>Fe>Pb>Zn>Mn in Seoul and Si>Fe>Zn>Pb>Mn in Asan. The concentration of metals in $PM_{10}$ of Seoul that Cr, Cu, Fe, Mn were high in spring and Zn was low in Fall. Fe, Mn were high in spring of Asan. 6. The results showed that average $PM_{2.5}$ composition order as Si>Pb>Fe>Zn>Mn in Seoul and Si>Fe>Pb>Zn>Cr in Asan. The concentration of metals in $PM_{2.5}$ of Seoul that Cr was high in spring. 7. The result showed that relation between Cr and Cu, Cu and Fe, Fe and Mn, Mn and Zn, Zn and Si in Seoul, Cr and Zn, Cu and Pb, Zn and Pb, Pb and Mn in Asan. The result showed that $PM_{10}$ concentration exceeding $50{\mu}g/m^3$(US-EPA Standard) and $PM_{2.5}$ concentration exceeding $15{\mu}g/m^3$(US-EPA Standard). In urban area, the monitoring of $PM_{2.5}$ permits the anthropogenic sources and the interference of natural sources with respect to $PM_{10}$ measurements.

한국재래오골계의 혈액상 및 혈액화학치에 관한 연구 - 1. 오골계의 혈액상에 관하여 (Studies on the Hematologic Values and Blood Chemistry Values of Korean Native Ogolgye 1. Hematologic Values for Korean Native Ogolgye)

  • 이한기;박옥윤
    • 대한수의사회지
    • /
    • 제20권4호
    • /
    • pp.233-238
    • /
    • 1984
  • 본 시험은 천연기념물 제265호인 182일령 한국재래종 오골계 20수(남 ; 10, 여 ; 10수)를 대상으로 정상혈액상을 구명하고 성별로 비교하여 유의성을 검정했던 바 다음과 같은 성적을 얻었기에 보고하는 바이다. 1. 적혈구치, 혈색소치 및 적혈구용적은 각각평균 $3.23\pm0.29\times10^6/{\mu}{\iota}$, 11.75$\pm$2.27g/100m1 및 33.41$\pm$4.85ml/100m1를 나타냈으며 이들은 공히 수컷이 암컷에 비해 그 수치가 다소 높았으나 성별 간에 유의성은 없었다. 2. 평균적혈구용적, 평균적혈구혈색소양 및 평균적혈구혈색소농도의 평균치는 각각 102.65$\pm$17.45f1, 36.36$\pm$6.20pg, 및 34.44$\pm$0.63g/100m1을 나타냈으며 성별간에 비슷한 경향이었다. 3. 백혈구수는 평균 $16.33\pm4.75\times10^3/{\mu}{\iota}$ 이고 성별간의 유의성은 없었으며 동요범위는 매우 넓었다. 4. 혈소판수의 평균치는 $2.85\pm0.43\times10^5/{\mu}{\iota}$ 이고 남; 2.79$\pm$0.55, 여 $2.95\pm0.37\times10^5/{\mu}{\iota}$ 으로서 남이 여에 비하여 다소 높았으나 성별간에 유의차는 인정되지 않았다. 5. 백혈구감별계수의 평균치는 Neutrophile $25.8\pm5.32\%$, Lymphocyte $59.1\pm6.48\%$, Eosinophile $3.0\pm1.50\%$, Basophile $2.6\pm1.14\%$ 및 Monocyte $9.5\pm2.95\%$로 성별간에 비슷한 수치를 보였다. 6. 적혈구의 크기는 장경$\times$단경$\times$두께가 남 $13.06\pm0.53{\mu}{\times}8.66\pm0.22{\mu}{\times}3.49\pm0.07{\mu}$, 여 $12.71\pm0.51{\mu}{\times}8.55\pm0.24{\mu}{\times}3.44\pm0.06{\mu}$을 나타내었다. 7. 각 측정치에 있어서 성별간에 대체적으로 차이를 보였으나 유의차는 인정되지 않았다.

  • PDF

Spatial analysis of $PM_{10}$ and cardiovascular mortality in the Seoul metropolitan area

  • Lim, Yu-Ra;Bae, Hyun-Joo;Lim, Youn-Hee;Yu, Seungdo;Kim, Geun-Bae;Cho, Yong-Sung
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.5.1-5.7
    • /
    • 2014
  • Objectives Numerous studies have revealed the adverse health effects of acute and chronic exposure to particulate matter less than $10{\mu}m$ in aerodynamic diameter ($PM_{10}$). The aim of the present study was to examine the spatial distribution of $PM_{10}$ concentrations and cardiovascular mortality and to investigate the spatial correlation between $PM_{10}$ and cardiovascular mortality using spatial scan statistic (SaTScan) and a regression model. Methods From 2008 to 2010, the spatial distribution of $PM_{10}$ in the Seoul metropolitan area was examined via kriging. In addition, a group of cardiovascular mortality cases was analyzed using SaTScan-based cluster exploration. Geographically weighted regression (GWR) was applied to investigate the correlation between $PM_{10}$ concentrations and cardiovascular mortality. Results An examination of the regional distribution of the cardiovascular mortality was higher in provincial districts (gu) belonging to Incheon and the northern part of Gyeonggi-do than in other regions. In a comparison of $PM_{10}$ concentrations and mortality cluster (MC) regions, all those belonging to MC 1 and MC 2 were found to belong to particulate matter (PM) 1 and PM 2 with high concentrations of air pollutants. In addition, the GWR showed that $PM_{10}$ has a statistically significant relation to cardiovascular mortality. Conclusions To investigate the relation between air pollution and health impact, spatial analyses can be utilized based on kriging, cluster exploration, and GWR for a more systematic and quantitative analysis. It has been proven that cardiovascular mortality is spatially related to the concentration of $PM_{10}$.

휴대용 실내 미세먼지 농도 측정 장치 개발 (Development of a portable system for monitoring indoor particulate matter concentration)

  • 김유진;최현슬;고태식
    • 한국가시화정보학회지
    • /
    • 제20권1호
    • /
    • pp.45-51
    • /
    • 2022
  • Airborne particulate matter(PM) has been a global environmental problem. PM whose diameter is smaller than 10 ㎛ can permeate respiratory organs and has harmful effects on human health. Therefore, PM monitoring systems are necessary for management of PM and prevention of PM-induced negative effects. Conventional PM monitoring techniques are expensive and cumbersome to handle. In the present study, two types of PM monitoring devices were designed for measuring indoor PM concentration, portably. We experimentally investigated the performance of three commercial PM concentration measurement sensors in a closed test chamber. As a result, PM2008 sensor showed the best PM concentration measurement accuracy. Linear regression method was applied to convert PM concentration value acquired from PM2008 sensor into ground truth value. A mobile application(app.) was also created for users to check the PM concentration, easily. The mobile app. also provides safety alarm when the PM10 concentration exceeds 81 ㎛/m3. The developed hand-held system enables the facile monitoring of surrounding air quality.

제주마 정액의 일반성상에 관한 연구 (Study on the Characteristics of Semen in Jeju Horse)

  • 양보석;강승률;이성수;조인철;정진관
    • 한국수정란이식학회지
    • /
    • 제16권2호
    • /
    • pp.127-131
    • /
    • 2001
  • 본 연구는 천연기념물로 지정되어 있는 제주마의 유전자원 보존과 증식을 위한 인공수정 기술의 실용화를 위한 기초자료를 제공하고자 제주도 축산진흥원에서 사육되고 있는 제주마 종마 4두를 공시하여 Missouri style 인공질을 이용 정액을 채취하여 사정 특성 및 정액의 일반 성상을 조사하였다. 제주마는 교미를 위하여 발정 중인 암말에 사정당 2.3$\pm$1.8회 승가를 하며 사정시간은 27.0$\pm$12.5초였다. 정액의 일반성상을 조사한 결과 총 정액량은 47.8$\pm$26.7ml, gel-free 양은 42.7$\pm$27.4ml, 정자농도는 270.7$\pm$112.9$\times$$10^{6}$ml로 사정당 총 정자수는 7.6$\pm$3.9$\times$$10^{9}$ ml였다. 또한 원정액중 생존 정자의 비율은 75.0$\pm$18.2%로 사정당 생존 정자수는 6.1$\pm$3.4$\times$$10^{9}$ ml였으며 gel-free 정액의 pH는 7.3$\pm$0.2이었다. 정자의 기형율은 평균 31.5%로서 부위별로는 미부가 15.0$\pm$15.0%, 두부가 9.5$\pm$11.7% 그리고 경부가 7.0$\pm$4.0%였다.

  • PDF

Polysomnographic Results before and after Uvulopalatopharyngoplasty

  • Kim, Cheon-Sik;Kim, Dae-Sik;Lee, Yong-Seok;Cho, Cheon-Ung;Pae, Sang-Ho;Kim, Won-Tae
    • 대한임상검사과학회지
    • /
    • 제45권2호
    • /
    • pp.73-76
    • /
    • 2013
  • Uvulopalatopharyngoplasty (UPPP) is one possibility for the treatment of Obstructive Sleep Apnea (OSA). The aim of this study was study the analysis of polysomnography of pre-UPPP and post-UPPP. All patients were evaluated by means of a physical examination, the epworth sleepiness scale (ESS), the beck depression inventory (BDI) and the nocturnal polysomnography (PSG) before surgery, and 6~12 months after surgery. A total of 15 patients were investigated. All underwent UPPP. The patients were between 26 and 62 years old ($mean{\pm}SD$; $39.7{\pm}10.9$) with a lean body mass index (BMI) of $mean{\pm}SD$; $26.2{\pm}3.0kg/m^2$. The comparison of sleep questionnaires showed that after UPPP, the patients had a significantly lower BMI ($26.2{\pm}3.0kg/m^2$ vs $26.0{\pm}3.4kg/m^2$, p=0.241), ESS ($10.0{\pm}5.4$ vs $6.9{\pm}3.2$, p=0.022), BDI ($9.2{\pm}8.2$ vs $4.2{\pm}4.3$, p=0.343) and higher blood pressure ($127.5{\pm}12.1$ vs $123.7{\pm}12.0$, p=0.272) compared to before UPPP. The comparison of sleep parameters showed that after UPPP, patients had a significantly lower stage N1 ($108.8{\pm}53.1$ vs $82.2{\pm}48.9$, p=0.016), lower sleep latency ($4.9{\pm}4.4$ vs $2.0{\pm}1.7$, p=0.083), a lower total arousal number ($210.6{\pm}90.3$ vs $147.1{\pm}87.3$, p=0.019), lower oxygen desaturation index (ODI) ($30.2{\pm}20.9$ vs $10.2{\pm}15.1$, p=0.006), lower apnea-hypopnea index (AHI) ($31.6{\pm}22.4$ vs $10.9{\pm}15.4$, p=0.005), and a lower respiratory disturbance index (RDI) ($37.4{\pm}21.3$ vs $18.5{\pm}16.5$, p=0.008) compared to after UPPP. The comparison of sleep parameters showed that after UPPP, patients had a significantly higher stage N2 ($154.0{\pm}39.9$ vs $180.5{\pm}49.5$, p=0.017), higher REM ($58.5{\pm}29.7$ vs $72.6{\pm}34.0$, p=0.249), higher $meanSaO_2$ ($94.3{\pm}2.0$ vs $95.9{\pm}0.9$, p=0.043), and higher $meanSaO_2$ ($79.3{\pm}8.5$ vs $83.1{\pm}7.9$, p=0.116) than before UPPP. After UPPP, 6 patients were cured, 2 showed marked improvement, and 7 did not improve. After surgery, the success of the treatment was at 53%. The subjective patient satisfaction was higher than before the surgery.

  • PDF