• Title/Summary/Keyword: $PM_{2.5}$ concentrations

Search Result 1,711, Processing Time 0.028 seconds

A Study on Spatial Differences in PM2.5 Concentrations According to Synoptic Meteorological Distribution (종관 기상 분포에 따른 PM2.5 농도의 공간적 차이에 관한 연구)

  • Da Eun Chae;Soon-Hwan Lee
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.999-1012
    • /
    • 2022
  • To investigate the reason for the spatial difference in PM2.5 (Particulate Matter, < 2.5 ㎛) concentration despite a similar synoptic pattern, a synoptic analysis was performed. The data used for this study were the daily average PM2.5 concentration and meteorological data observed from 2016 to 2020 in Busan and Seoul metropolitan areas. Synoptic pressure patterns associated with high PM2.5 concentration episodes (greater than 35 ㎍/m3) were analyzed using K-means cluster analysis, based on the 900 hPa geopotential height of NCEP (National Centers for Environmental Prediction) FNL (Final analysis) data. The analysis identified three sub-groups related to high concentrations occurring only in Busan and Seoul metropolitan areas. Although the synoptic patterns of high PM2.5 concentration episodes that occur independently in Busan and Seoul metropolitan areas were similar, there was a difference in the intensity of pressure gradient and its direction, which tends to be an important factor determining the movement time of pollutants. The spatial difference in PM2.5 concentration in the Korean Peninsula is due to the difference and direction of the atmospheric pressure gradient that develops from southwest to northeast direction.

Mass Size Distribution of Atmospheric Aerosol Particles Collected at 865 m High of Jirisan National Park (지리산 국립공원 해발 865 m 지점에서 대기에어로졸입자의 입경별 질량농도 특성)

  • Ryu, Hye-Ji;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.26 no.1
    • /
    • pp.29-36
    • /
    • 2017
  • Aerosol mass size distributions were investigated at 865 m high the of Jirisan national park. A nanosampler cascade impactor was used to collect aerosols. The atmospheric aerosol particles had a unimodal mass size distribution, which peaked at $0.5-1.0{\mu}m$, and a mass aerodynamic diameter of $1.13{\mu}m$. The annual average concentrations of TSP, $PM_{10}$, $PM_{2.5}$, $PM_1$, $PM_{0.5}$ and $PM_{0.1}$ were $20.9{\mu}g/m^3$, $19.3{\mu}g/m^3$, $14.9{\mu}g/m^3$, $10.7{\mu}g/m^3$, $5.3{\mu}g/m^3$, $1.2{\mu}g/m^3$, respectively. TSP concentrations were below $30{\mu}g/m^3$ during the sampling period. On average $PM_{10}$, $PM_{2.5}$, $PM_1$, $PM_{0.5}$ and $PM_{0.1}$ made up 0.91, 0.70, 0.41, 0.19 and 0.07 of TSP, respectively. The annual average of PM2.5/PM10 ratio was 0.77.

Effect of Suckling Systems on Serum Oxytocin and Cortisol Concentrations and Behavior to a Novel Object in Beef Calves

  • Chen, Siyu;Tanaka, Shigefumi;Ogura, Shin-ichiro;Roh, Sanggun;Sato, Shusuke
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.11
    • /
    • pp.1662-1668
    • /
    • 2015
  • We investigated differences between effects of natural- and bucket-suckling methods on basal serum oxytocin (OT) and cortisol concentrations, and the effect of OT concentration on affiliative and investigative behavior of calves to a novel object. Ten Japanese Black calves, balanced with birth order, were allocated evenly to natural-suckling (NS) and bucket suckling (BS) groups. Blood samples were collected at the ages of 1 and 2 months (1 week after weaning) calves, and serum OT and cortisol concentrations were measured using enzyme-linked immunosorbent assay and enzymeimmunoassay tests, respectively. Each calf at the age of 2 months (2 weeks after weaning) was released into an open-field with a calf decoy, and its investigative and affiliative behaviors were recorded for 20 minutes. In 1-month-old calves, the basal serum OT concentration ($25.5{\pm}4.9$ [mean${\pm}$standard deviation, pg/mL]) of NS was significantly higher than that of BS ($16.9{\pm}6.7$) (p<0.05), whereas the basal cortisol concentration ($5.8{\pm}2.5$ [mean${\pm}$standard deviation, ng/mL]) of NS was significantly lower than that in BS ($10.0{\pm}2.8$) (p<0.05). Additionally, a negative correlation was noted between serum OT and cortisol concentrations in 1-month-old calves (p = 0.06). Further, the higher serum OT concentration the calves had at 1 month old, the more investigative the calves were at 2 months old but not affiliative in the open-field with a calf decoy. Thus, we concluded that the natural suckling method from a dam elevates the basal serum OT concentration in calves, and high serum OT concentrations induce investigative behavior and attenuate cortisol concentrations.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals - (대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 -)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Lee, Jun-Jung;Oh, In-Bo;Shon, Byung-Hyun;Lee, Hyung-Don;Yoon, Mi-Ra;Kim, Geun-Bae;Yu, Seung-do;Min, Young-Sun;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

Aerosol Density Determined Using Micro-orifice Uniform Deposit Impactor and Aerosol Dust Monitors Data at Seoul (다단입자채집기와 입자계수기 자료를 이용한 서울 에어러솔 밀도 계산)

  • Kim, Jeong-Eun;Lee, Hae-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.298-304
    • /
    • 2010
  • In order to calculate the aerosol bulk densities of $PM_{1.0}$ and $PM_{10}$, aerosol mass and number concentrations were measured for the period of December 2008~April 2009. $PM_{1.0}$ and $PM_{10}$ mass concentrations were measured using a cascade impactor (Micro-Orifice Uniform Deposit Impactor, MOUDI) while their volume concentrations were calculated based on number concentrations from an environmental dust monitor (EDM). Normal aerosol size distribution fitting functions were retrieved for number size distribution since aerosols < $2.5{\mu}m$ were measured from the EDM. Strong correlation was found between $PM_{1.0}$ mass and volume concentrations obtained with a $R^2$ of 0.95. The calculated average bulk densities of $PM_{1.0}$ and $PM_{10}$ were $1.97{\pm}0.33g/cm^3$ and $2.15{\pm}0.18g/cm^3$, respectively.

Indoor to Outdoor Ratio of Fine Particulate Matter by Time of the Day in House According to Time-activity Patterns (시간활동양상에 따른 주택의 시간대별 실내·실외 초미세먼지 농도비)

  • Park, Jinhyeon;Kim, Eunchae;Choe, Youngtae;Ryu, Hyoensu;Kim, Sunshin;Woo, Byung Lyul;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.504-512
    • /
    • 2020
  • Objective: The purpose of this study was to evaluate the indoor to outdoor ratio (I/O ratio) of time activity patterns affecting PM2.5 concentrations in homes in Korea through a simulation. Methods: The time activity patterns of homemakers were analyzed based on the 'Time-Use Survey' data of the National Statistical Office in 2014. From September 30 to October 2, 2019, the experimenter lived in multifamily housing located in Guro-gu, Seoul. The I/O ratio of PM2.5 concentration was measured by installing sensor-based instruments. Results: The average indoor and outdoor PM2.5 concentrations during the three days were 33.1±48.9 and 45.9±25.3 ㎍/㎥, respectively. The average I/O ratio was 0.75±0.60. The indoor concentration tended to increase when PM2.5 source activity such cooking and cleaning was present and outdoor PM2.5 was supplied through ventilation. Conclusions: This study could be used as basic data for estimating indoor PM2.5 concentrations with personal activity pattern and weather conditions using outdoor concentrations.

Ionic Compositions and Carbonaceous Matter of PM2.5 at Ieodo Ocean Research Station (이어도 해양과학기지 PM2.5의 이온과 탄소 조성 특성)

  • Han, Jihyun;Kim, Jahan;Kang, Eunha;Lee, Meehye;Shim, Jae-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.701-712
    • /
    • 2013
  • The purpose of this study is to determine concentrations and compositions of $PM_{2.5}$ and their characteristic variations at Ieodo Ocean Research Station in the East China Sea and to examine the influence of air pollutants transported from Asia continents. $O_3$ and meteorological parameters were measured since June 2003 and $PM_{2.5}$ filter samples were collected from June 2004 to June 2008. In total, 244 samples were analyzed for water soluble ions and carbonaceous compounds. The mean mass concentration of $PM_{2.5}$ and $O_3$ were $21.8{\pm}14.9{\mu}g/m^3$ and $51.6{\pm}16.1$ ppb, respectively. The average concentrations (mass fractions) of sulfate and ammonium were $6.26{\mu}g/m^3$ (28.74%) and $1.59{\mu}g/m^3$ (7.31%), respectively. Nitrate was considered to be lost through evaporation due to long stay at the station. The mean concentrations of EC and OC were $1.01{\mu}g/m^3$ and $2.34{\mu}g/m^3$, respectively, from June 2006 to June 2008. The average OC/EC ratio was 2.31. The organic matter converted from OC by multiplying 2.1 and elemental carbon constituted 22.60% and 4.66% of $PM_{2.5}$ mass, respectively.

Characterization of PM10 and PM2.5 Mass Concentrations in Jinju (진주시 대기중 PM10 및 PM2.5의 질량농도 특성)

  • Park, Jeong-Ho;Park, Gee-Hyeong;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.1963-1970
    • /
    • 2014
  • Ambient particulate matters($PM_{10}$ and $PM_{2.5}$) were investigated at GNTECH university in Jinju city. Samples were collected using a dichotomous sampler(series 240, Andersen Corp.) and a TEOM(Tapered Element Oscillating Microbalance) monitor period from November 2012 to October 2013. For the dichotomous sampler measurements, daily 24-h integrated $PM_{2.5}$ and $PM_{10-2.5}$ ambient air samples were collected at a total flow rate of 16.7 L /min. For the TEOM monitor measurements, daily 1-h integrated $PM_{10}$ ambient air samples were collected at a flow rate of 16.7 L /min. The annual average concentrations of $PM_{10-2.5}$ and $PM_{2.5}$ by a dichotomous sampler were $10.0{\pm}6.1{\mu}g/m^3$ and $22.6{\pm}9.3{\mu}g/m^3$, respectively. And $PM_{10}$ concentration by dichotomous sampler were similar to TEOM monitor by $32.7{\pm}12.9{\mu}g/m^3$ and $31.7{\pm}11.3{\mu}g/m^3$, respectively. And good correlation ($R^2=0.964$) between the two methods was observed. The annual average of $PM_{2.5}/PM_{10}$ ratio was $0.70{\pm}0.12$.

Emission Characteristics of PM10 and PM2.5 in Thermal Power Plants Using Different Fuel Types (연료별 화력발전시설의 미세먼지(PM10 및 PM2.5) 배출특성)

  • Park, Hyun-Soo;Lee, Duk-An;Yang, Jeong-Go;Jang, Seong-Guk;Kim, Hwan-Beom;Kim, Deug-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.534-541
    • /
    • 2018
  • Concentrations of total particulate matter (TPM), $PM_{10}$ and $PM_{2.5}$ were measured at three different sites based on each different fuel type (solid, liquid and gas) used in thermal power plants operating in Yeosu and Gwangyang National Industrial Complexes during 2017. The highest concentrations of TPM, $PM_{10}$, and $PM_{2.5}$ were observed at the solid fuel facility, and these values were $3.356mg/Sm^3$, $2.342mg/Sm^3$ and $1.834mg/Sm^3$, respectively. The ratio of $PM_{2.5}$ to TPM was the highest value of 54.6% in solid fuel case, and the lowest was 35.7% found in liquid fuel case. As a result of analyzing 9 kinds of metal compound with respect to each particle size, the metal concentration of TPM is higher than those of $PM_{10}$ and $PM_{2.5}$ in all fuel types. Total concentrations of metal elements in TPM by fuel difference are $1.2702mg/Sm^3$ in solid fuel, 0.0603 mg/Sm3 in liquid fuel, and $0.0733mg/Sm^3$ in gas fuel, respectively. Relatively higher total metal concentration in gas fuel than in liquid fuel was found; and this could be higher Cr and Al concentrations in use of gas fuel. As a result of estimating the emission factors of each facility, in case of solid fuel, TPM emissions per electricity production were found to be 0.7080 kt/PJ, followed by liquid fuel and gas fuel. $PM_{10}$ and $PM_{2.5}$ emissions per hour of electricity production were similar to those of TPM.

Iodine Concentrations in Commercial Milks and Bulk Tank Milks of Dairy Farms Performed Different Teat Dipping Methods (젖소 목장의 유두침지소독 방법에 따른 집합유와 시판 우유 내 요오드 농도)

  • Jeong, Jihyeok;Kim, Danil;Kim, Doo
    • Journal of Veterinary Clinics
    • /
    • v.33 no.5
    • /
    • pp.274-277
    • /
    • 2016
  • To determine the concentrations of commercial milks and the effect of different teat dipping methods on iodine concentrations of bulk tank milk, iodine concentration was analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The 59 bulk tank milk samples were collected. The 8 brands of commercial whole milk and 5 brands of commercial organic milk were purchased. The iodine concentrations of bulk tank milks of 59 dairy farms were in the range from 42.7 to $562.5{\mu}g/L$. The iodine levels of 4 different teat dipping methods with pre-dipping, post-dipping, pre & post-dipping, and non-dipping were $138.9{\pm}41.1$, $200.6{\pm}106.9$, $205.1{\pm}93.2$, and $110.9{\pm}70.4{\mu}g/L$, respectively. No significant difference (P > 0.05) was observed among 4 different teat dipping methods. Iodine concentrations of commercial whole milks were in the range from 149.1 to $210.4(178.8{\pm}22.0){\mu}g/L$, and iodine concentrations of commercial organic milks were in the range from 85.0 to $356.9(214.2{\pm}123.3){\mu}g/L$. Iodine concentrations of commercial milk in Korea are relatively low comparing with those of other countries.