• Title/Summary/Keyword: $PM_{2.1}$ & $PM_{10}$

Search Result 14,823, Processing Time 0.052 seconds

Hematological and Serum Chemical Values in Pere David′s Deer and Wapiti (사불상 및 와피티 사슴의 혈액 및 혈청화학치)

  • Shin Nam-Sik;Kwon Soo-Wahn;Han Duk-Hwan;Lee Heung-Shik
    • Journal of Veterinary Clinics
    • /
    • v.11 no.1
    • /
    • pp.471-478
    • /
    • 1994
  • The hematologic values and serum chemistry were examined healthy male 12 Pere David's Deer and 8 Wapiti at the Farmland Zoological Garden. In wapiti, the blood values collected from horn and jugular vein were compared. The results were as follows: 1. There were not any significant differences in hematologic values and serum chemistry of blood col. looted from horn and jugular vein in wapiti. 2. In Pere David's Deer, Mean$\pm$SD Values of White Blood Cell(WBC) count were 4673.50$\pm$1893.42/${mu}ell$, of Neutrophils 65.42$\pm$12.7%, of Lymphocytes 31.50$\pm$8.68%, of Monocytes 0.25$\pm$0.43%, of Eosinophils 0.17$\pm$0.37%. of Basophils, of Red Blood Cell(RBC) 9.93$\pm$1.38$\times$10/${mu}ell$, of PCV 54.25$\pm$6.25%, of Hb 16.89$\pm$2.43g/㎗, of Tot protein 7.63$\pm$0.6g/㎗, of Cholesterol 87.25$\pm$10.76mg/㎗, of Glucose 109.36$\pm$43.7mg/㎗, of SGOT 85.17$\pm$33IU/$\ell$, of SGPT 102.92$\pm$31.49IU/$\ell$, of BUN 21.00$\pm$5.18mg/㎗, of Creatinine 2.1$\pm$0.43mg/㎗, of ALKP 156$\pm$32.72IU/$\ell$, of Ca 11.28$\pm$1.04mg/㎗, of Na 127.92$\pm$10.04mmo1/$\ell$, of NH3 102.83$\pm$42.25mmo1/$\ell$, of Cl 105.91$\pm$3.45mmo1/$\ell$, respectively. 3. In wapiti, Mean$\pm$SD Values of White Blood Cell(WBC) count were 3450.00$\pm$1040.73/${mu}ell$, of Neutrophils 53.88$\pm$7.42%, of Lymphocytes 36.00$\pm$5.72%, of Monocytes 1.13$\pm$1.05%, of Eosinophils 1.38$\pm$1.93%, of Basophils 7.63$\pm$4.15%, of Red Blood Cell 10.09$\pm$1.3$\times$10/${mu}ell$, of PCV 46.88$\pm$3.33%, of H 15.09$\pm$1.48g/㎗, of Total protein 7.15$\pm$0.73g/㎗, of Cholesterol 78.63$\pm$12.27mg/㎗, of Glucose 75.63$\pm$33.22mg/㎗ , of SGOT 79.25$\pm$18.43IU/$\ell$, of SGPT 36.50$\pm$19.20IU/$\ell$, of BUN 29.63$\pm$4.15mg/㎗, of Creatinine 1.35$\pm$0.21mg/㎗ , of ALKP 283.50$\pm$88.13IU/$\ell$, of Ca 9.78$\pm$0.43mg/㎗ , of Na 120.00$\pm$10.02mmol/$\ell$, of NH3 261.50$\pm$ 103.46mmol/$\ell$, of Cl 92.00$\pm$9.19mmol/$\ell$, respectively.

  • PDF

A Study of the Insulin and the C-Peptide Responses to Oral Glucose Load in Nondiabetic and Diabetic Subjects (정상인(正常人) 및 당뇨병환자(糖尿病患者)에서의 경구당부하시(經口糖負荷時) 혈중(血中) Insulin과 C-Peptide의 변동(變動))

  • Lee, Myung-Chul;Choi, Sung-Jae;Kim, Eung-Jin;Min, Hun-Ki;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.11 no.1
    • /
    • pp.17-32
    • /
    • 1977
  • The present study was undertaken to evaluate the significance of the insulin and the C-peptide rseponse to oral glucose loads in normal and diabetic subjects and to establish the effects of the obesity. In this study, the authors have measured plasma insulin and C-peptide by means of radioimmunoassay in 10 nonobese normal, 5 obese normal, 13 nonobese moderate diabetic patients, 9 obese moderate diabetic patients and 9 severe diabetic patients. The results obtained were as follows; 1. In 10 nonobese normal subjects, the plasma insulin level at fasting state and at 30, 60, 90, and 120 min after oral glucose loads were $15.7{\pm}3.4,\;48.3{\pm}9.8,\;40.4{\pm}6.7,\;37.4{\pm}6.5\;and\;26.0{\pm}4.2uU/ml(Mean{\pm}S.E.)$ and C-peptide were $1.9{\pm}0.3,\;3.9{\pm}0.6,\;6.3{\pm}0.6,\;5.7{\pm}0.5\;and\;4.0{\pm}0.5ng/ml$. The change of C-peptide was found to go almost parallel with that of insulin and the insulin value reaches to the highest level at 30 min whereas C-peptide reaches to its peak at 60min. 2. The plasma insulin level in 5 obese normal subjects were $38.9{\pm}12.3,\;59.5{\pm}12.3,\;59.2{\pm}17.1,\;56.1{\pm}20.0\;and\;48.4{\pm}17.2uU/ml$ and the C-peptide were $5.5{\pm}0.4,\;6.8{\pm}0.5,\;7.9{\pm}0.8,\;7.9{\pm}0.8\;and\;7.8{\pm}2.0ng/ml$. The insulin response appeared to be greater than nonobese normal subjects. 3. In 13 nonobese moderate diabetic patients, the plasma insulin levels were $27.1{\pm}4.9,\;44.1{\pm}6.0,\;37.3{\pm}6.6,\;35.5{\pm}8.1\;and\;34.7{\pm}10.7uU/ml$ and the C-peptide levels were $2.7{\pm}0.4,\;4.9{\pm}0.7,\;6.5{\pm}0.5,\;7.0{\pm}0.3\;and\;6.7{\pm}1.0ng/ml$. There was little significance compared to nonobese normal groups but delayed pattern is noted. 4. In 9 obese moderated diabetic patients, the plasma insulin levels were $22.1{\pm}7.9,\;80.0{\pm}19.3,\;108.0{\pm}27.0,\;62.0{\pm}17.6\;and\;55.5{\pm}10.1uU/ml$ and the C-peptide levels were $5.2{\pm}0.4,\;8.0{\pm}1.0,\;10.4{\pm}1.6,\;10.4{\pm}1.7\;and\;10.1{\pm}1.0ng/ml$ and its response was also greater than that of nonobese moderate diabetic patients. 5. The plasma insulin concentrations in 9 severe diabetic subjects were $8.0{\pm}3.8,\;12.1{\pm}3.5,\;16.8{\pm}4.6,\;19.6{\pm}5.2\;and\;15.0{\pm}5.0uU/ml$ and the C-peptide levels were $1.6{\pm}0.3,\;2.4{\pm}0.4,\;4.1{\pm}0.6,\;4.0{\pm}0.8\;and\;4.5{\pm}0.7ng/ml$ and the insulin and C-peptide responses were markedly reduced in severe diabetic groups. 6. There were-significant differences between each groups of patients on the magnitude of total insulin or C-peptide areas, the insulinogenic index and the C-peptide index.

  • PDF

Regional Analysis of Particulate Matter Concentration Risk in South Korea (국내 지역별 미세먼지 농도 리스크 분석)

  • Oh, Jang Wook;Lim, Tea Jin
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.157-167
    • /
    • 2017
  • Millions of People die every year from diseases caused by exposure to outdoor air pollution. Especially, one of the most severe types of air pollution is fine particulate matter (PM10, PM2.5). South Korea also has been suffered from severe PM. This paper analyzes regional risks induced by PM10 and PM2.5 that have affected domestic area of Korea during 2014~2016.3Q. We investigated daily maxima of PM10 and PM2.5 data observed on 284 stations in South Korea, and found extremely high outlier. We employed extreme value distributions to fit the PM10 and PM2.5 data, but a single distribution did not fit the data well. For theses reasons, we implemented extreme mixture models such as the generalized Pareto distribution(GPD) with the normal, the gamma, the Weibull and the log-normal, respectively. Next, we divided the whole area into 16 regions and analyzed characteristics of PM risks by developing the FN-curves. Finally, we estimated 1-month, 1-quater, half year, 1-year and 3-years period return levels, respectively. The severity rankings of PM10 and PM2.5 concentration turned out to be different from region to region. The capital area revealed the worst PM risk in all seasons. The reason for high PM risk even in the yellow dust free season (Jun. ~ Sep.) can be inferred from the concentration of factories in this area. Gwangju showed the highest return level of PM2.5, even if the return level of PM10 was relatively low. This phenomenon implies that we should investigate chemical mechanisms for making PM2.5 in the vicinity of Gwangju area. On the other hand, Gyeongbuk and Ulsan exposed relatively high PM10 risk and low PM2.5 risk. This indicates that the management policy of PM risk in the west side should be different from that in the east side. The results of this research may provide insights for managing regional risks induced by PM10 and PM2.5 in South Korea.

Study on the Radial Variation of Structural Element in the Diffuse-Porous Woods (주요산공재(主要散孔材) 구성요소(構成要素)의 방사방향(放射方向) 변동(變動)에 관한 연구(硏究))

  • Han, Cheol-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.26-52
    • /
    • 1987
  • Among the diffuse-porous woods which arc dominant in Korea and used as construction materials due to their wood quality, ten species of six genus involving seven species of three genus in Betulaceae were studied on the radial variation of structural demenb. The species studied were Betula platyphylla var. japonica, B. ermanii, B. davurica, B. scstata, B. schmidtii, Carpinus laxifora, Alnus japonica, Prunus sargentii. Acer mono and Diospyros kaki. Wood fiber, vessel elements and ray increased rapidly in size from pith to a certain annual ring. After then the radial variation in size of the main structural elements seemed to be divided into three types; levelled off curve pattern indicating constant size(type I), continuously increasing curve pattern showing ever increase in size (type II) and parabolic curve pattern showing the gradual decrease after the maximum (type III), but the variation types by structural dements were different even in the same species. Based on the results from this study, it appears to be reasonable to consider the stabilized age of wood fiber, vessel elements and ray rather than considering wood fiber length in distinguishing mature woods from juvenile woods.

  • PDF

The Metallic Elements of PM10 and PM2.5 in Western Region of Busan in the Springtime of 2005 (2005년 봄철 부산 서부지역 PM10, PM2.5의 금속성분 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.5
    • /
    • pp.327-340
    • /
    • 2007
  • The $PM_{10}$ and $PM_{2.5}$ aerosols were collected at Busan from March to May, 2005, and the concentrations of some metallic elements were analysed to study their characteristics. The mean concentration of $PM_{10}$ was $66.5{\pm}23.0{\mu}g/m^3$ with a range of 22.2 to $118.1{\mu}g/m^3$. The mean concentration of $PM_{2.5}$ was $46.1{\pm}17.2{\mu}g/m^3$ with a range of 9.7 to $83.3{\mu}g/m^3$. The ratio of $PM_{2.5}/PM_{10}$ was 0.69 at Busan. The distribution of metallic elements for $PM_{10}$ and $PM_{2.5}$ were Cd${\ldots}$ ${\ldots}$ $PM_{10}$ were $94.9{\mu}g/m^3$ and $63.7{\mu}g/m^3$, respectively. And The mean mass concentrations of Asian dust and non Asian dust in $PM_{2.5}$ were $56.9{\mu}g/m^3$ and $45.1{\mu}g/m^3$, respectively. The mean values of crustal enrichment factors for five elements (Cd, Cu, Pb, V and Zn) were all higher than 10, possibly suggesting the influence of anthropogenic sources. The soil contribution ratios for $PM_{10}$ and $PM_{2.5}$ were 20.5% and 19.4, respectively.

Effect of Daily Mean PM10 and PM2.5 on Distribution of Excessive Mortality Risks from Respiratory and Cardiovascular Diseases in Busan (부산지역 PM10, PM2.5 일평균에 의한 호흡기 및 심혈관질환 초과위험도 분포)

  • Do, Woo-gon;Jung, Woo-sik
    • Journal of Environmental Science International
    • /
    • v.30 no.7
    • /
    • pp.573-584
    • /
    • 2021
  • To analyze the effects of PM10 and PM2.5 on daily mortality cases, the relations of death counts from natural causes, respiratory diseases, and cardiovascular diseases with PM10 and PM2.5 concentrations were applied to the generalized additive model (GAM) in this study. From the coefficients of the GAM model, the excessive mortality risks due to an increase of 10 ㎍/m3 in daily mean PM10 and PM2.5 for each cause were calculated. The excessive risks of deaths from natural causes, respiratory diseases, and cardiovascular diseases were 0.64%, 1.69%, and 1.16%, respectively, owing to PM10 increase and 0.42%, 2.80%, and 0.91%, respectively, owing to PM2.5 increase. Our result showed that particulate matter posed a greater risk of death from respiratory diseases and is consistent with the cases in Europe and China. The regional distribution of excessive risk of death is 0.24%-0.81%, 0.34%-2.6%, and 0.62%-1.94% from natural causes, respiratory diseases, and cardiovascular diseases, respectively, owing to PM10 increase, and 0.14%-1.02%, 1.07%-3.92%, and 0.22%-1.73% from natural causes, respiratory diseases, and cardiovascular diseases, respectively, owing to PM2.5 increase. Our results represented a different aspect from the regional concentration distributions. Thus, we saw that the concentration distributions of air pollutants differ from the affected areas and identified the need for a policy to reduce damage rather than reduce concentrations.

The Effects of Exopolysaccharide Produced by Streptococcus thermophilus BODY1 on Infection of Rotavirus in MA-104 Cell (Streptococcus thermophilus BODY1이 생성하는 Exopolysaccharide가 Rotavirus의 MA-104 세포감염에 미치는 영향)

  • Song, Jin-Ook;Kim, Yong-Hui
    • Food Science of Animal Resources
    • /
    • v.26 no.4
    • /
    • pp.532-539
    • /
    • 2006
  • This study was conducted to evaluate the inhibitory effects of exopolysaccharide(EPS) produced by Streptococcus thermophilus BODY1 on rotavirus(RV). EPS was isolated from a commercial lactic acid bacteria, Str. thermophilus BODY1. The results obtained were as follows : At 0.1% of EPS, inhibitory effects of EPS on the MA-104 cell using MTT assay were, $Wa\;51.58{\pm}8.08%,\;KU \;63.09{\pm}7.58%,\;S2\;51.23{\pm}5.43%,\;YO\; 51.45{\pm}5.67%,\;K-21\;52.84{\pm}5.49%,\;NCDV\;57.50{\pm}10.85%,\;UK\;51.64{\pm}4.74%,\;KK3\;54.53{\pm}8.44%,\;JBR\;58.67{\pm}7.51%,\;S97\;50.63{\pm}5.17%,\;OSU\;55.48{\pm}5.75%,\;and\;RRV\;54.36{\pm}8.72%$, respectively. At 0.1/128%, the effects were $Wa\;5.5{\pm}6.45%,\;KU\;10.33{\pm}8.39%,\;S2\;0.98{\pm}8.39%,\;YO\;4.25{\pm}2.86%,\;K-21\;4.25{\pm}6.60%,\;NCDV\;4.01{\pm}4.12%,\;UK\;6.55{\pm}7.09%,\;KK3\;5.19{\pm}4.86%,\;JBR\;11.11{\pm}8.11%,\;S97\;6.75{\pm}6.95%,\;OSU\;10.14{\pm}8.54%,\;and\;RRV\;3.66{\pm}8.57%$, respectively. These results indicate that EPS have inhibitory effects on various serotype and sources of RV from different animals.

PRODUCTION PERFORMANCE AND MILK PRODUCING EFFICIENCY IN DIFFERENT FILIAL GROUPS OF H. FRIESIAN × SAHIWAL HALFBREDS

  • Chaudhry, M.Z.;Tahir, M.J.;Rafique, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.7 no.3
    • /
    • pp.383-387
    • /
    • 1994
  • Six heifers each of $F_1$, $F_2$, $F_3$, $F_4$ H. Friesian $\times$ Sahjwal halfbreds and pure Sahiwal with overall average initial age and live weight of $315.6{\pm}134.8 days$ and $143.8{\pm}48.5kg$, respectively were used for this study. The under trial animals were fed according to N.R.C. (1978). The overall average age at maturity, first conception and first calving was $563.8{\pm}116.8$, $675.8{\pm}135.6$ and $956.8{\pm}149.8days$ with live weights as $302.2{\pm}58.6$, $342.6{\pm}41.5$ and $433.9{\pm}38.1kg$, respectively. The overall 305 days and total milk yield for 1st lactation was $2,729.0{\pm}669.3$ and $2,992.7{\pm}377.5litre$ while the FCM (at 4%) was $2,934.2{\pm}410.8litre$. The lactation length was $336.6{\pm}69.6days$. The fat and solids not fat contents were $4.5{\pm}0.2$ and $8.2{\pm}0.3percent$, respectively. The milk production in Sahiwal cows was significantly lower than crossbred cows. The services per conception were $2.5{\pm}1.3$. The overall per head per day consumption of DM, TCP and ME was $10.9{\pm}1.2kg$, $1,399{\pm}199gm$ and $22.6{\pm}2.4 M.Cal.$, respectively. The overall milk producing efficiency for the production of one litre of FCM was $1.12{\pm}0.15kg$ of DM, $142.2{\pm}17.76gm$ of TCP and $2.31{\pm}0.27M.Cal.$ of energy while the feeding cost was Rs. $1.46{\pm}0.22$ per litre of FCM produced. The feeding cost per litre FCM was significantly higher in Sahiwal and $F_2$ than in other genetic groups.

Characterization of Annual PM2.5 and PM10 Concentrations by Real-time Measurements in Cheonan, Chungnam (실시간 측정을 통한 천안시 대기 중 연간 PM2.5, PM10 농도 특성 조사)

  • Heo, Jung-Hyuk;Oh, Se-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.445-450
    • /
    • 2012
  • From 2015, PM2.5 standards will be added to Korean national ambient air quality standards. To characterize PM2.5 levels in Cheonan, annual PM2.5 concentrations along with PM10 concentrations were investigated between February 2010 and January 2011 using a dust monitor. The annual PM2.5 concentration was $40.45{\mu}g/m^3$ and over the standards($25{\mu}g/m^3$). The daily average PM2.5 concentrations ranged from 2.43 to $178.84{\mu}g/m^3$, and 26% days exceeded the daily PM2.5 standard($50{\mu}g/m^3$). During the same periods, only 11% days exceeded the daily PM10 standard, showing that PM2.5 were more concerning levels than PM10. Seasonal variations showed the highest concentrations in spring and winter, and lowest concentration in summer due to heavy rain fall. Changes in PM2.5 concentrations during the day were remarkable and showed the highest concentrations in commuting periods. The results indicated that the concentrations of PM2.5 in Cheonan were at the concerning level, and mainly from the mobile sources.

Field tests of indoor air cleaners for removal of PM2.5 and PM10 in elementary school's classrooms in Seoul, Korea (서울 초등학교 교실의 PM2.5 및 PM10 제거를 위한 학교용 공기청정기 실증)

  • Han, Bangwoo;Hong, Keejung;Shin, Dongho;Kim, Hakjoon;Kim, Yongjin;Kim, Sangbok;Kim, Sangwoo;Hwang, Cheongha;Noh, Kwangchul
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.79-90
    • /
    • 2019
  • It is important to control fine particles in children care centers, elementary schools, elderly care facilities and so on where vulnerable children and the aged stay during most of their time. This study has investigated $PM_{2.5}$ and $PM_{10}$ concentrations in two classrooms equipped with an air cleaner and two air cleaners, respectively and they were compared to those in a classroom without an air cleaner as well as those outdoors. Eight air cleaners which have various clean air delivery rates (CADRs) between 9.9 and $21.3m^3/min$ were tested in classrooms in two elementary schools in Seoul. Average $PM_{2.5}$ and $PM_{10}$ were $7.3{\pm}0.7$ and $45.5{\pm}4.1{\mu}g/m^3$ in classrooms equipped with an air cleaner and $4.2{\pm}0.6$ and $24.6{\pm}2.5{\mu}g/m^3$ in classrooms with two air cleaners, whereas they were $22.1{\pm}2.6$ and $109.1{\pm}9.6{\mu}g/m^3$ in classrooms without an air cleaner and $36.9{\pm}5.1$ and $74.1{\pm}10.6{\mu}g/m^3$ outdoors, respectively. $PM_{2.5}$ in classrooms could be reduced effectively by using an air cleaner or two air cleaners, because $PM_{2.5}$ was mainly infiltrated from outdoors, however $PM_{10}$ could not because $PM_{10}$ was mainly caused indoors by students' activities. Air cleaners were more effective for removal of $PM_{2.5}$ and $PM_{10}$ in classrooms with a high airtightness than those in classrooms with a relatively low one. Average $CO_2$ in classrooms was about 1500 to 2000 ppm for class hours dependent on the student number per a classroom, which was about 1.5 to 2 times higher than the standard, regardless of the use of air cleaner.