• 제목/요약/키워드: $PM_{10}$$PM_{2.5}$$PM_1$

검색결과 10,795건 처리시간 0.041초

Polysomnographic Results before and after Uvulopalatopharyngoplasty

  • Kim, Cheon-Sik;Kim, Dae-Sik;Lee, Yong-Seok;Cho, Cheon-Ung;Pae, Sang-Ho;Kim, Won-Tae
    • 대한임상검사과학회지
    • /
    • 제45권2호
    • /
    • pp.73-76
    • /
    • 2013
  • Uvulopalatopharyngoplasty (UPPP) is one possibility for the treatment of Obstructive Sleep Apnea (OSA). The aim of this study was study the analysis of polysomnography of pre-UPPP and post-UPPP. All patients were evaluated by means of a physical examination, the epworth sleepiness scale (ESS), the beck depression inventory (BDI) and the nocturnal polysomnography (PSG) before surgery, and 6~12 months after surgery. A total of 15 patients were investigated. All underwent UPPP. The patients were between 26 and 62 years old ($mean{\pm}SD$; $39.7{\pm}10.9$) with a lean body mass index (BMI) of $mean{\pm}SD$; $26.2{\pm}3.0kg/m^2$. The comparison of sleep questionnaires showed that after UPPP, the patients had a significantly lower BMI ($26.2{\pm}3.0kg/m^2$ vs $26.0{\pm}3.4kg/m^2$, p=0.241), ESS ($10.0{\pm}5.4$ vs $6.9{\pm}3.2$, p=0.022), BDI ($9.2{\pm}8.2$ vs $4.2{\pm}4.3$, p=0.343) and higher blood pressure ($127.5{\pm}12.1$ vs $123.7{\pm}12.0$, p=0.272) compared to before UPPP. The comparison of sleep parameters showed that after UPPP, patients had a significantly lower stage N1 ($108.8{\pm}53.1$ vs $82.2{\pm}48.9$, p=0.016), lower sleep latency ($4.9{\pm}4.4$ vs $2.0{\pm}1.7$, p=0.083), a lower total arousal number ($210.6{\pm}90.3$ vs $147.1{\pm}87.3$, p=0.019), lower oxygen desaturation index (ODI) ($30.2{\pm}20.9$ vs $10.2{\pm}15.1$, p=0.006), lower apnea-hypopnea index (AHI) ($31.6{\pm}22.4$ vs $10.9{\pm}15.4$, p=0.005), and a lower respiratory disturbance index (RDI) ($37.4{\pm}21.3$ vs $18.5{\pm}16.5$, p=0.008) compared to after UPPP. The comparison of sleep parameters showed that after UPPP, patients had a significantly higher stage N2 ($154.0{\pm}39.9$ vs $180.5{\pm}49.5$, p=0.017), higher REM ($58.5{\pm}29.7$ vs $72.6{\pm}34.0$, p=0.249), higher $meanSaO_2$ ($94.3{\pm}2.0$ vs $95.9{\pm}0.9$, p=0.043), and higher $meanSaO_2$ ($79.3{\pm}8.5$ vs $83.1{\pm}7.9$, p=0.116) than before UPPP. After UPPP, 6 patients were cured, 2 showed marked improvement, and 7 did not improve. After surgery, the success of the treatment was at 53%. The subjective patient satisfaction was higher than before the surgery.

  • PDF

진주시 대기중 PM10 및 PM2.5의 질량농도 특성 (Characterization of PM10 and PM2.5 Mass Concentrations in Jinju)

  • 박정호;박기형;서정민
    • 한국환경과학회지
    • /
    • 제23권12호
    • /
    • pp.1963-1970
    • /
    • 2014
  • Ambient particulate matters($PM_{10}$ and $PM_{2.5}$) were investigated at GNTECH university in Jinju city. Samples were collected using a dichotomous sampler(series 240, Andersen Corp.) and a TEOM(Tapered Element Oscillating Microbalance) monitor period from November 2012 to October 2013. For the dichotomous sampler measurements, daily 24-h integrated $PM_{2.5}$ and $PM_{10-2.5}$ ambient air samples were collected at a total flow rate of 16.7 L /min. For the TEOM monitor measurements, daily 1-h integrated $PM_{10}$ ambient air samples were collected at a flow rate of 16.7 L /min. The annual average concentrations of $PM_{10-2.5}$ and $PM_{2.5}$ by a dichotomous sampler were $10.0{\pm}6.1{\mu}g/m^3$ and $22.6{\pm}9.3{\mu}g/m^3$, respectively. And $PM_{10}$ concentration by dichotomous sampler were similar to TEOM monitor by $32.7{\pm}12.9{\mu}g/m^3$ and $31.7{\pm}11.3{\mu}g/m^3$, respectively. And good correlation ($R^2=0.964$) between the two methods was observed. The annual average of $PM_{2.5}/PM_{10}$ ratio was $0.70{\pm}0.12$.

서울 초등학교 교실의 PM2.5 및 PM10 제거를 위한 학교용 공기청정기 실증 (Field tests of indoor air cleaners for removal of PM2.5 and PM10 in elementary school's classrooms in Seoul, Korea)

  • 한방우;홍기정;신동호;김학준;김용진;김상복;김상우;황청하;노광철
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.79-90
    • /
    • 2019
  • It is important to control fine particles in children care centers, elementary schools, elderly care facilities and so on where vulnerable children and the aged stay during most of their time. This study has investigated $PM_{2.5}$ and $PM_{10}$ concentrations in two classrooms equipped with an air cleaner and two air cleaners, respectively and they were compared to those in a classroom without an air cleaner as well as those outdoors. Eight air cleaners which have various clean air delivery rates (CADRs) between 9.9 and $21.3m^3/min$ were tested in classrooms in two elementary schools in Seoul. Average $PM_{2.5}$ and $PM_{10}$ were $7.3{\pm}0.7$ and $45.5{\pm}4.1{\mu}g/m^3$ in classrooms equipped with an air cleaner and $4.2{\pm}0.6$ and $24.6{\pm}2.5{\mu}g/m^3$ in classrooms with two air cleaners, whereas they were $22.1{\pm}2.6$ and $109.1{\pm}9.6{\mu}g/m^3$ in classrooms without an air cleaner and $36.9{\pm}5.1$ and $74.1{\pm}10.6{\mu}g/m^3$ outdoors, respectively. $PM_{2.5}$ in classrooms could be reduced effectively by using an air cleaner or two air cleaners, because $PM_{2.5}$ was mainly infiltrated from outdoors, however $PM_{10}$ could not because $PM_{10}$ was mainly caused indoors by students' activities. Air cleaners were more effective for removal of $PM_{2.5}$ and $PM_{10}$ in classrooms with a high airtightness than those in classrooms with a relatively low one. Average $CO_2$ in classrooms was about 1500 to 2000 ppm for class hours dependent on the student number per a classroom, which was about 1.5 to 2 times higher than the standard, regardless of the use of air cleaner.

서울시 미세먼지(PM10)와 초미세먼지(PM2.5)의 단기노출로 인한 사망영향 (Effects of Short-term Exposure to PM10 and PM2.5 on Mortality in Seoul)

  • 배현주
    • 한국환경보건학회지
    • /
    • 제40권5호
    • /
    • pp.346-354
    • /
    • 2014
  • Objectives: Although a number of epidemiologic studies have examined the association between air pollution and mortality, data limitations have resulted in fewer studies of particulate matter with an aerodynamic diameter of ${\leq}2.5{\mu}m$ ($PM_{2.5}$). We conducted a time-series study of the acute effects of particulate matter with an aerodynamic diameter of ${\leq}10{\mu}m$($PM_{10}$) and $PM_{2.5}$ on the increased risk of death for all causes and cardiovascular mortality in Seoul, Korea from 2006 to 2010. Methods: We applied the generalized additive model (GAM) with penalized splines, adjusting for time, day of week, holiday, temperature, and relative humidity in order to investigate the association between risk of mortality and particulate matter. Results: We found that $PM_{10}$ and $PM_{2.5}$ were associated with an increased risk of mortality for all causes and of cardiovascular mortality in Seoul. A $10{\mu}g/m^3$ increase in the concentration of $PM_{10}$ corresponded to 0.44% (95% Confidence Interval [CI]: 0.25-0.63%), and 0.95% (95% CI: 0.16-1.73%) increase of all causes and of cardiovascular mortality. A $10{\mu}g/m^3$ increase in the concentration of $PM_{2.5}$ corresponded to 0.76% (95% CI: 0.40-1.12%), and 1.63% (95% CI: 0.89-2.37%) increase of all causes and cardiovascular mortality. Conclusion: We conclude that $PM_{10}$ and $PM_{2.5}$ have an adverse effect on population health and that this strengthens the rationale for further limiting levels of $PM_{10}$ and $PM_{2.5}$ in Seoul.

서울시 지하철 객차 내 PM과 CO2의 농도 분포 (A Survey of Particulate Matters and CO2 Levels in Seoul Subway Carriages)

  • 이철민;박화미;노영만;김윤신;박동선
    • 한국환경보건학회지
    • /
    • 제34권1호
    • /
    • pp.34-41
    • /
    • 2008
  • The objective of this study is to provide the research data on the actual concentrations of $PM_{10},\;PM_{2.5},\;PM_1\;and\;CO_2$ in Seoul subway carriages. Mean concentrations of $PM_{10},\;PM_{2.5}\;and\;PM_1,\;and\;CO_2$ in subway carriages were investigated at levels of $215.1{\pm}101.4{\mu}g/m^3,\;86.9{\pm}38.6{\mu}g/m^3,\;27.0{\pm}11.4{\mu}g/m^3,\;and\;1,588{\pm}714ppm$, respectively. The mean concentrations in subway carriages were higher when the train ran on an underground track rather than on an above ground track. The measured concentration of particulate matter varied with the time of day and was highest in the morning, followed by noon and evening while the $CO_2$ concentration was highest in the morning, followed by evening and noon. In relation to correlation among the pollutants: the correlation between $PM_{10}\;and\;PM_{2.5}$ was 0.92, and that between $PM_{2.5}\;and\;PM_1$ was 0.94. The inclusion rate of $PM_{2.5}\;to\;PM_{10}$ was $41{\pm}7%$ and that of $PM_1\;to\;PM_{2.5}\;was\;32{\pm}4%$. In addition, the $CO_2$ concentration had a positive relation with the number of people in a carriage, whereas the concentration of $PM_{10}$ had negative correlation to the number of people. In relation to these two pollutants we calculated using a regression equation (34.06+0.04$CO_2$(ppm)-0.09 PM10$({\mu}g/m^3)$($R^2$=0.30, p<0.01, n=707), that a maximum number of 61 persons would ensure that each pollutant is maintained below the criteria level, applicable to subway stations.

대구지역 대기 중 PM-10과 PM-2.5의 농도분포 특성 (Distribution Characteristics of the Concentration of Ambient PM-10 and PM-2.5 in Daegu Area)

  • 도화석;최수진;박민숙;임종기;권종대;김은경;송희봉
    • 대한환경공학회지
    • /
    • 제36권1호
    • /
    • pp.20-28
    • /
    • 2014
  • 대구지역의 13개 대기오염측정소 중 PM-10과 PM-2.5를 동시에 측정하는 3개 측정소 즉, 공업지역에 위치한 이현동, 주거지역에 위치한 만촌동, 도로변에 위치한 평리동 측정소를 대상으로 최근 2년간(2011~2012)의 자료를 이용하여 PM-10과 PM-2.5의 농도분포 특성을 연구하였다. PM-10 농도는 이현동($52.5{\mu}g/m^3$)과 평리동($60.9{\mu}g/m^3$) 모두 연평균 기준치인 $50{\mu}g/m^3$을 초과하였고, 만촌동($44.9{\mu}g/m^3$)은 기준치를 만족하였다. PM-2.5 농도는 세 지점 모두 미국의 EPA 연간기준치($15{\mu}g/m^3$)를 초과하였으며, 우리나라에서 2015년부터 시행되는 PM-2.5의 연평균기준치($25{\mu}g/m^3$)도 초과하는 수준이었다. 계절별 변화를 보면, PM-10은 봄철 > 겨울철 > 가을철 > 여름철 순이었고, PM-2.5는 겨울철 > 봄철 > 가을철 > 여름철 순으로 나타나는 특성을 보였다. 월변화 특성을 보면, PM-10과 PM-2.5 모두 겨울철인 2월에 가장 높고 여름철인 9월경에 가장 낮은 농도를 보였다. 일변화 특성을 보면, PM-10과 PM-2.5 모두 오전 7시부터 증가하여 10시~11시경에 최고 농도를 기록하고 오후 6시까지 하강하여 저녁과 새벽까지 일정한 농도를 나타내는 경향을 보였다. 또한, 주중의 미세먼지 농도는 주말보다 높은 농도를 보였으며, 그 변동 폭은 공업지역이 주거지역보다 크게 나타났다. PM-2.5/PM-10 비는 여름철이 높고 봄철이 가장 낮게 나타났고, 황사발생시 PM-2.5/PM-10 비는 비황사시 0.54~0.64에 비해 0.32~0.42로 매우 낮은 특성을 보였다. 본 자료는 대구지역의 미세먼지(PM-10, PM-2.5)의 현황과 특성에 대한 연구로써 향후 미세먼지의 연구 및 대기오염 관리에 유용하게 사용될 것으로 사료된다.

부산지역 PM10, PM2.5 일평균에 의한 호흡기 및 심혈관질환 초과위험도 분포 (Effect of Daily Mean PM10 and PM2.5 on Distribution of Excessive Mortality Risks from Respiratory and Cardiovascular Diseases in Busan)

  • 도우곤;정우식
    • 한국환경과학회지
    • /
    • 제30권7호
    • /
    • pp.573-584
    • /
    • 2021
  • To analyze the effects of PM10 and PM2.5 on daily mortality cases, the relations of death counts from natural causes, respiratory diseases, and cardiovascular diseases with PM10 and PM2.5 concentrations were applied to the generalized additive model (GAM) in this study. From the coefficients of the GAM model, the excessive mortality risks due to an increase of 10 ㎍/m3 in daily mean PM10 and PM2.5 for each cause were calculated. The excessive risks of deaths from natural causes, respiratory diseases, and cardiovascular diseases were 0.64%, 1.69%, and 1.16%, respectively, owing to PM10 increase and 0.42%, 2.80%, and 0.91%, respectively, owing to PM2.5 increase. Our result showed that particulate matter posed a greater risk of death from respiratory diseases and is consistent with the cases in Europe and China. The regional distribution of excessive risk of death is 0.24%-0.81%, 0.34%-2.6%, and 0.62%-1.94% from natural causes, respiratory diseases, and cardiovascular diseases, respectively, owing to PM10 increase, and 0.14%-1.02%, 1.07%-3.92%, and 0.22%-1.73% from natural causes, respiratory diseases, and cardiovascular diseases, respectively, owing to PM2.5 increase. Our results represented a different aspect from the regional concentration distributions. Thus, we saw that the concentration distributions of air pollutants differ from the affected areas and identified the need for a policy to reduce damage rather than reduce concentrations.

Characteristics of PM10, PM2.5 and PM2.5/PM10 Ratio in Air Monitoring Stations in Gyeongnam

  • Park, Jeong-Ho;Suh, Jeong-Min
    • 한국환경과학회지
    • /
    • 제27권10호
    • /
    • pp.925-931
    • /
    • 2018
  • The characteristics of $PM_{10}$, $PM_{2.5}$ and Ratio($PM_{2.5}/PM_{10}$) of 11 urban air monitoring stations in Gyeongnam were analyzed for the last 3 years('15~'17). The average of the all stations was $PM_{10}\;45{\mu}g/m^3$, $PM_{2.5}\;24{\mu}g/m^3$ and Ratio 0.54, and annual reduction rates were $PM_{10}-2.9%$, $PM_{2.5}-2.7%$ and Ratio -1.2%, respectively. The seasonal characteristics of $PM_{10}$ were spring $54{\mu}g/m^3$ > winter $48{\mu}g/m^3$ > summer/autumn $40{\mu}g/m^3$, $PM_{2.5}$ were spring/winter $26{\mu}g/m^3$ > summer 23 > autumn $22{\mu}g/m^3$ and Ratio were summer 0.56 > winter 0.55 > autumn 0.54 > spring 0.51, respectively. The hourly characteristics of $PM_{10}$ were $11{\mu}g/m^3$ higher than 09:00~12:00 at 03:00~06:00, $PM_{2.5}$ were $6{\mu}g/m^3$ higher than 09:00~12:00 at 17:00~18:00 and Ratio were 0.07 higher than 04:00~06:00 at 19:00. By site, the highest concentration of $PM_{10}$ was YJ site $53{\mu}g/m^3$ and $PM_{2.5}$ was HW site $28{\mu}g/m^3$. And Ratio at HD site showed the largest reduction from '15 0.62 to '17 0.52.

익산지역에서 황사발생시 PM2.5, PM10 TSP의 농도 특성 (Concentration Characteristics of Atmospheric PM2.5, PM10 and TSP during the Asian Dust Storm in Iksan Area)

  • 강공언;김남송;김경숙;김미경;이현주
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.408-421
    • /
    • 2007
  • The concentration characteristics of atmospheric particle matters (PM) including $PM_{2.5},\;PM_{10}$, and TSP were evaluated through the measurement data of PM_{2.5}$ (fine particulate), PM_{10-2.5}$ (coarse particulate), and PM_{over-10}$ collected using a MCI (multi-nozzle cascade impactor) sampler of a three-stage filter pack in spring of 2006 in Iksan area. During the sampling period of 10-15 March and 24 days from 8 April to 2 May, 32 samples for PM of each size fractions were collected, and then measured for PM mass concentrations and water-soluble inorganic ion species. Average concentrations of $PM_{2.5},\;PM_{10}$, TSP were $57.9{\pm}44.1mg/m^3$, $96.6{\pm}89.1mg/m^3$, and $114.8{\pm}99.7mg/m^3$, respectively. Water-soluble inorganic ion fractions to PM mass were found to be 36.5%, 18.0%, and 11.1% for $PM_{2.5}$, $PM_{10-2.5}$ and $PM_{over-10}$, respectively. By showing the high concentrations of PM samples during Asian dust events, those three fractions of PM were distinguished between the samples of Asian dust event and the samples of no event. However, the increase of PM concentrations observed during Asian dust events showed a different pattern for some Asian dust events. The differences of those three fractions in the size distribution may depend on differences on place of occurrence of Asian dust storm and course of transport from China continent to Iksan area in Korea. However, the extent of PM mass contribution during Asian dust events was generally dominated by the coarse particles rather than the fine fraction of PM. The variations of water-soluble inorganic ion species concentration in those three PM fractions between the samples of Asian dust event and the samples of no event were also discussed in this study.

한국 아동의 에너지 소비량에 관한 연구 (A Study on Energy Expenditure in Korean Children)

  • 오승호
    • 한국식품영양과학회지
    • /
    • 제22권5호
    • /
    • pp.531-538
    • /
    • 1993
  • 본 연구는 8-12세의 남녀 국민학생 각각 8명씩을 대상으로 4주간 평상시와 같은 생활양식과 식생활 환경하에서 에너지 섭취량(GE)과 체내 에너지 보류량 (BE)의 변동을 측정하므로서(에너지 평형법) 에너지 소비량을 산출하였다. 에너지 섭취량과 대변으로의 에너지 손실량(FE)은 열량계로 측정하였고 소변으로의 에너지 손실량(UE)은 질소 배설량으로부터 환산하였다. 체내 지방조직량(FM)은 피부두께를 측정하여 산출한 신체 밀도법에 의하였다. 총 에너지 섭취량에 대한 당질, 단백질 및 지방질의 구성비는 남자 아동이 각각 70.0$\pm$0.5%, 10.2$\pm$0.3% 및 19.9$\pm$0.5%이었으며 여자 아동이 각각 74.0$\pm$1.7%, 10.7$\pm$0.3%및 15.3$\pm$0. 5%이었다. 총 에너지 섭취량에 대한 대변으로의 에너지 손실율은 남자 및 여자 아동별로 각각 5.1%및 4. 5%이었다. 대변과 소변으로의 에너지 손실량을 감하여 산출한 1일 1인당 평균 대사에너지량(ME)은 남자 및 여자 아동별 각각 1862$\pm$15kca1 및 1627$\pm$20kca1 이었다. 28일 동안의 체성분 변동량으로부터 산출한 체내 총 에너지 변동량(BE)은 남자 및 여자 아동별로 각각 평균 +1524$\pm$539kcal 및 +3622$\pm$718kcal가 증가하였다. 1일 1인당 평균 에너지 소비량은 남자 아동이 1812$\pm$37kca1이고 여자 아동이 1487$\pm$25kcal로서 체중 kg당 에너지 소비량은 남자 및 여자 아동별로 각각 62 $\pm$2kcal 및 52 $\pm$2kcal이었다.

  • PDF