• Title/Summary/Keyword: $NO_x$ gas

Search Result 562, Processing Time 0.022 seconds

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.

The effect of Postural Changes on Pleural Fluid Constituents (흉수 구성 성분의 체위에 따른 차이)

  • Park, Byung-Kyu;Lee, Hyo-Jin;Kim, Yun-Seong;Heo, Jeong;Yang, Yong-Seok;Seoung, Nak-Heon;Lee, Min-Ki;Park, Soon-Kew;Shin, Young-Kee;Han, Kyeong-Moon;Choi, Pil-Sun;Soon, Choon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.221-227
    • /
    • 1996
  • Background : Measurement of pleural fluid constituents are of value in the diagnosis of pleural effusions and in the seperation of exudates from transudates. The position of the patient(sitting or lying) prior to thoracentesis may result in difference in the measurement of these constituents. The purpose of this study is to determine whether postural differences in pleural fluid constituents exist, and if so, whether they are of any clinical significance. Method : 41 patients with pleural effusions on chest roentgenography were prospectively studied. The fluid cell counts, partial gas tension, and concentrations of chemical constituents were compared in the supine and upright positions. Results : 1) A total of 10 patients were found to have an transudative effusion. In the transudates there was no significant difference in pleural fluid constituents according to posture change. 2) A total of 31 patients were found to have an exudative effusion. Statistically significant postural changes were noted in pH, WBC counts, protein, and LDH concentrations in the exudates. It may be due to postural sedimentary effect in the pleural space. 3) The PCO2 measurements and glucose concentration were not affected by changes in position in exudates or transudates. Conclusion : Postural sedimentary effect occurs in the pleural space with reference to the measurement of certain pleural fluid constituents when an inflammatory process is present. Therefore it is recommended that thoracentesis after 30 minutes in the sitting position should be performed.

  • PDF