• 제목/요약/키워드: $NO_2$gas

검색결과 2,394건 처리시간 0.033초

플라즈마 방전에 의한 $SO_x, NO_x$의 분해 (Decomposition of $SO_x, NO_x$ by Plasma Discharge)

  • 우인성;강현춘
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.73-77
    • /
    • 1999
  • In this study, $SO_2$ and $NO_2$ reduction have been investigated by using coil type plasma reactor. The experiments have been carried out changing discharge power, gas flow rate frequency and electrode style to obtain the decomposition rate. Decomposition rates of $SO_2$ and $NO_2$ were obtained 20~98% at gas flow rate 100ml/min~1,000ml/min and discharge power 5~25w respectively. The energy efficiency is very good at the high frequency power. The decomposition rate of $SO_2$ for 5kHz power supply is only 90%, but for 10kHz power supply is very high, more than 98% for 15w. The decomposition rate is increasing according to the residence time or the power consumption of the discharge. About 15W discharge power for 17$cm^2$ reactor is necessary to obtain the decomposition rate of $SO_2$ and $NO_2$ of more than 85% or 98%. From these experiments, the consumption power of the decomposition rate of 98% in 300ppm $NO_2$ gas in nitrogen gas proved to be 18W and 300ppm $SO_2$ gas to be 15w.

  • PDF

주택특성에 관련된 실내 이산화질소 농도에 관한 연구 (A Study on Concentration of Indoor Nitrogen Dioxide in Relation to House Characteristics)

  • 양원호;배현주;김현용;정문식;정문호
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.85-92
    • /
    • 1999
  • Indoor air quality tends to be the dominant contributor to personal exposure because most people spend over 90% of their time indoors. For some contaminants, exposure to indoor air poses a potentially greater health threat than outdoor air exposures. Indoor nitrogen dioxide ($NO_2$) levels are mainly affected gas range, flue gas spillage, kerosene heaters, wood-burning appliances and cigarette smoke. In addition, indoor $NO_2$ levels are influenced by such house characterization as surface reaction and air exchange rate. In this study, the measurements of indoor and outdoor $NO_2$ concentrations were taken using identical protocols, and information was collected on housing characteristics using identical questionnaires in 14 houses out of 15 houses for daily 30 daily 30 days in Brisbane, Australia.The usage of gas range was the most contributing factor in indoor $NO_2$ concentration in relation to house characteristics. Average indoor and outdoor ratios of NO2 concentration in electronic and gas cooking houses were $0.6{\pm}0.1$ and $0.9{\pm}0.2$, respectively. The frequency distributions of $NO_2$ concentration in each house were approximately log-normal Geometric mean of indoor $NO_2$ concentrations of electronic and gas cooking houses for daily 30 days ranged from 2.5 ppm to 11.5 ppm with a mean 6.8 and from 4.7 ppm to 28.6 ppm with a mean 15.6 ppm, respectively. The $NO_2$ concentrations between electronic and gas cooking houses were significantly different (p<0.05). Since each house has different life-style and house characteristics, sampling interval to measure the $NO_2$ levels was recommended above 7 days.

  • PDF

Fabrication and characteristics of NOx gas sensors using WO3 and In2O3 thick films to monitor air pollution

  • 손명우;최정범;황학인;유광수
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.263-268
    • /
    • 2009
  • With the increasing number of automobiles, the problem of air pollution from the exhaust gases of automobiles has become a critical issue. The principal gases that cause air pollution are nitrogen oxide or NO$_x$(NO and NO$_2$), and CO. Because NO$_x$ gases cause acid rain and global warming and produce ozone(O$_3$) that leads to serious metropolitan smog from photochemical reaction, they must be detected and reduced. Mixtures of WO$_3$ and $In_2O_3$(WO$_3$:$In_2O_3$=10:0, 7:3, 5:5, 3:7, and 0:10 in wt.%), which are NO$_x$ gas-sensing materials, were prepared, and thick-film gas sensors that included a heater and a temperature sensor were fabricated. Their sensitivity to NO$_x$ was measured at 250$\sim$400$^{\circ}C$ for NO$_x$ concentrations of 1$\sim$5 ppm. The $In_2O_3$ thick-film sensor showed excellent sensitivity($R_{gas}/R_{air}$=10.22) at 300$^{\circ}C$ to 5-ppm NO. The response time for 70 % saturated sensitivity was about 3 seconds, and the sensors exhibited very fast reactivity to NO$_x$.

Pt-$WO_3-Si_3N_4-SiO_2$-Si-Al 캐패시터를 이용한 $NO_2$ 가스 센서 ($NO_2$ Gas Sensor Utilizing Pt-$WO_3-Si_3N_4-SiO_2$-Si-Al Capacitor)

  • 김창교;이주헌;이영환;유광수;김영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.105-108
    • /
    • 1998
  • Pt-WO$_3$-Si$_3$N$_4$-SiO$_2$-Si-Al 캐패시터를 이용한 NO$_2$ 가스 센서를 개발하였다. 표준 실리콘 MNOS구조에 촉매 게이트로 Pt와 가스 흡착층으로 WO$_3$를 이용함으로서 전통적인 세라믹 가스 센서보다 낮은 온도에서 NO$_2$ 가스를 감지할 수 있었다. 은도 변화와 NO$_2$ 가스 농도의 변화에 따라서 디바이스의 NO$_2$ 가스 감도를 조사하였다. Pt-WO$_3$ 계면에서 NO$_2$ 이온농도의 변화에 기초로 한 가스 감지 모델을 제시하였다. 제시된 가스 감지 모델을 계면에서의 가스 반응 속도론에 의하여 분석함으로서 확인하였다.

  • PDF

휴대용 가스렌지 연소에 의한 공기오염물질의 발생량 및 실내환경의 필요 환기량 (Source Emission Rate on Air Pollutants from Portable Gas Range and Optimal Ventilation Rate in Indoor Environment)

  • 임성국;김영희;양원호
    • 한국환경보건학회지
    • /
    • 제33권2호
    • /
    • pp.92-97
    • /
    • 2007
  • A series of source tests were conducted to characterize emissions of nitrogen oxide(NOx, NO, $NO_2$), carbon mon oxide(CO), carbon dioxide$(CO_2)$ and total VOCs from portable combustion devices in steady-state using well-mixed chamber. Since use of portable gas range is widespread in houses and restaurants in Korea, it is important to characterize the emission of air pollutants and suggest optimum ventilation rate. Ranges of emission rates of air pollutants from portable gas ranges were $NO \;0.551\sim0.939mg/hr,\;NO_2\;0.354\sim1.080mg/hr,\;NO_x\;1.207\sim1.631mg/hr,\;CO\;1.389\sim4.21mg/hr,\;CO_2\;2426.823\sim2973.495mg/hr$, and VOCs $0\sim0.119mg/h$. Mean of personal exposure and indoor environment level of $NO_2$ by combustion of portable gas range were 74.7 ppb and 65.4 ppb, respectively, suggesting persons using portable gas range in houses and restaurants might be highly exposed. Required ventilation rate to control the air pollutants emitted from portable gas range was maximumly $3.131m^3/hr$ on the basis of $NO_2$ indoor air quality standard.

수열합성법으로 합성된 산화구리 나노막대의 일산화질소 가스 감지 특성 (Nitrogen Monoxide Gas Sensing Properties of CuO Nanorods Synthesized by a Hydrothermal Method)

  • 박수정;김효진;김도진
    • 한국재료학회지
    • /
    • 제24권1호
    • /
    • pp.19-24
    • /
    • 2014
  • We report the nitrogen monoxide (NO) gas sensing properties of p-type CuO-nanorod-based gas sensors. We synthesized the p-type CuO nanorods with breadth of about 30 nm and length of about 330 nm by a hydrothermal method using an as-deposited CuO seed layer prepared on a $Si/SiO_2$ substrate by the sputtering method. We fabricated polycrystalline CuO nanorod arrays at $80^{\circ}C$ under the hydrothermal condition of 1:1 morality ratio between copper nitrate trihydrate [$Cu(NO_2)_2{\cdot}3H_2O$] and hexamethylenetetramine ($C_6H_{12}N_4$). Structural characterizations revealed that we prepared the pure CuO nanorod array of a monoclinic crystalline structure without any obvious formation of secondary phase. It was found from the gas sensing measurements that the p-type CuO nanorod gas sensors exhibited a maximum sensitivity to NO gas in dry air at an operating temperature as low as $200^{\circ}C$. We also found that these CuO nanorod gas sensors showed reversible and reliable electrical response to NO gas at a range of operating temperatures. These results would indicate some potential applications of the p-type semiconductor CuO nanorods as promising sensing materials for gas sensors, including various types of p-n junction gas sensors.

플라즈마 반응기구조에 따른 코로나방전 및 NO-NO$_2$ 전환특성에 관한 실험적 연구 (Experimental Study on the Effect of Plasma Reactor Type on Corona Discharge and NO-NO2 Conversion Characteristics)

  • 박용성;전광민
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.65-71
    • /
    • 2002
  • Characteristics of corona discharge of the different types of the plasma reactors which are cone-hole and cone-plate is investigated experimentally. The discharge starts at lower voltage for the cathode corona than the anode corona and spark occurs at higher voltage for the cathode corona. And the cathode corona makes more stable discharge than the anode corona. The effect of the base gas in corona discharge for different O$_2$/N$_2$ concentrations is related with the gas molecular weight. The discharge for the smaller molecular weight gas occurs easier than for the high molecular weight gas. The discharge current decreases with the increase of oxygen concentration and it increases more sharply for anode corona than for cathode corona as discharge voltage increases after corona onset voltage. NO-NO$_2$ conversion increases with the energy density of corona discharge and the addition of O$_2$ in a base N$_2$ gas.

고온 배기가스의 산소농도가 배기가스이용 확산화염의 $NO_{x}$ 발생에 미치는 영향 (The Effect of Oxygen Concentration in Hot Exhaust Gas on the $NO_{x}$ Emission of Diffusion Flame in Exhaust Gas)

  • 손화승;장시웅;최동수;김호영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.115-120
    • /
    • 2001
  • The present study examined the possibility of $NO_{x}$ reduction in the high temperature industrial furnaces. duct burner of gas turbine cogeneration and two-stage gas turbine combustor. The experimental study was carried out for the diffusion flame of second stage combustor with the variations of oxygen concentration and supplying rate of hot exhaust gas from first stage combustor. It also examined the flammability range and $NO_{x}$ formation of the second stage combustor in which the fuel is supplying into the mixture of oxygen hot exhaust gas from first stage combustor. The results show that the enrichment of oxygen and increase of exhaust gas lead to increase the $NO_{x}$ up to 50 ppm with 23% $O_{2}$ condition.

  • PDF

MEMS 공정으로 제작한 $NO_2$ 마이크로 가스센서의 열전달 해석 (Heat Transfer Analysis for $NO_2$ Micro Gas Sensor Fabricated by MEMS Technology)

  • 주영철;이창훈;김창교
    • 한국산학기술학회논문지
    • /
    • 제5권2호
    • /
    • pp.132-136
    • /
    • 2004
  • 대기중의 NO₂ 가스 농도를 측정하기 위한 마이크로 가스센서를 MEMS 공정을 이용하여 제작하였다. WO₃와 같은 가스 감응물질을 목표 온도까지 가열하기 위해서 마이크로 핫플레이트를 가스센서에 장착하였다. 마이크로 가스센서의 열전달 현상을 상용 열유동 해석 전용 프로그램인 FLUENT를 이용하여 해석하였다. 해석 결과 실리콘 웨이퍼 기판의 온도가 거의 상온에 가까워 핫플레이트에서 발생한 열이 가스 감응물질을 효과적으로 가열하여서 가스감응물질의 열적 고립상태를 유지하고 있는 것을 알 수 있었다. 마이크로 핫플레이트의 형상을 변경함으로써 가스 감지물질의 온도 균일도를 높일 수 있다.

  • PDF

Copper-tetra-tert-butylphthalocyanine(CuTBP) LB 막의 NO$_2$ 가스탐지 특성에 관한 연구 (A study on the NO$_2$gas detection characteristics of the Copper - tetra - tert -butylphthatsocyanine (CuTBP ) LB Film)

  • 김형석;유병호;조형근;한영재;김태완;김정수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.118-121
    • /
    • 1994
  • The NO$_2$ gas-detection characteristics were investigated using the functional organic Langmuir-Blodgett(LB) film of Copper-tetra-tert-butylphalocyanine(CUTBP). The optimum conditions for a film deposition were obtained through a study of $\pi$-A isotherm and the deposited film status was confirmed by ellipsometry measurements. In the NO$_2$ response experiments, first of all, the proper number of layer was obtained by a change of the electrical conductivities depending on the number of layer when the film is exposed to the gas. And response time, recovery time, and reproducibility were measured on it. On the other hand, how the NO$_2$ gas interacts to the LB film was studied by UV/visible absorption spectra.