Effect of $NH_3$/NOx ratio and Catalyst Temperature on DeNOx Performance in the $NH_3$-SCR reactor ($NH_3$-SCR 반응기 내에서의 $NH_3$/NOx 및 SCR 촉매 온도가 DeNOx 성능에 미치는 영향)

  • Hong, Kil-Hwa;Gong, Ho-Jeong;Hwang, In-Goo;Park, Sim-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3096-3101
    • /
    • 2008
  • Selective Catalytic Reduction (SCR) technology is well-known to be effective for the reduction of NOx emission. So car manufacturers has adopted Ures-SCR system to be satisfied with emission regulation. This paper discusses the effective of $NH_3/NOx$ ratio and SCR catalyst temperature in the $NH_3$-SCR reactor on DeNOx performance. So it is shown the characteristic of NOx conversion and ammonia slip using the $NH_3$ instead of Urea-Solution. From the result of this study, it is found to optimize $NH_3/NOx$ ratio to have the best case of high NOx conversion and low ammonia slip at variable SCR catalyst temperatures. Lastly, it is also found the characteristics of NOx conversion and ammonia slip with compared with Urea.

  • PDF

A Study on the Injection Characteristics of Urea Solution to Improve deNOx Performance of Urea-SCR Catalyst in a Heavy Duty Diesel Engine (대형 디젤 엔진용 요소분사 SCR촉매의 deNOx 성능향상을 위한 요소수용액의 분사특성 연구)

  • Jeong, Soo-Jin;Lee, Chun-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.165-172
    • /
    • 2008
  • Urea-SCR, the selective catalytic reduction using urea as reducing agent, has been investigated for about 10 years in detail and today is a well established technique for deNOx of stationary diesel engines. In the case of the SCR-catalyst a non-uniform velocity and $NH_3$ profile will cause an inhomogeneous conversion of the reducing agent $NH_3$, resulting in a local breakthrough of $NH_3$ or increasing NOx emissions. Therefore, this work investigates the effect of flow and $NH_3$ non-uniformities on the deNOx performance and $NH_3$ slip in a Urea-SCR exhaust system. From the results of this study, it is found that flow and $NH_3$ distribution within SCR monolith is strongly related with deNOx performance of SCR catalyst. It is also found that multi-hole injector shows better $NH_3$ uniformity at the face of SCR monolith face than one hole injector.

Performance Prediction of SCR-DeNOx System for Reduction of Diesel Engine NOx Emission (디젤엔진의 NOx 저감을 위한 SCR-DeNOx 후처리 시스템 성능 예측)

  • 김만영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.71-76
    • /
    • 2003
  • A numerical simulation of selective catalytic reduction (SCR) for NO with $NH_3$ is conducted over the $V_2O_5/TiO_2$ and $WO_3-V_2O_5/TiO_2$ catalysts. The governing $NH_3$ and NO transport equations are considered by using the time-dependent FCT (Flux-Corrected Transport) algorithm. After a validating simulation for $NH_3$ step feed and shut-off experiments is analyzed, transient behavior of $NH_3$ and NO concentration in a SCR catalyst is investigated by changing such parameters as inflow $NH_3$ concentration, temperature of the catalyst, and $NH_3$/NOx ratios.

Experimental Study on DeNOx Characteristics of Urea-SCR System (Urea-SCR 시스템의 DeNOx 특성에 관한 실험적 연구)

  • Ham, Yun-Young;Lee, Seong-Ho;Jung, Hong-Seok;Shin, Dong-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.180-186
    • /
    • 2009
  • To meet the NOx limit without a penalty of fuel consumption, urea SCR system is currently regarded as promising NOx reduction technology for diesel engines. SCR system has to achieve maximal NOx conversion in combination with minimal $NH_3$ slip. In this study, as a basic research to develop an algorithm for urea injection control, the characteristics of engine out NOx emission and behavior of NOx reduction during steady-state and transient conditions were investigated using 2L DI diesel engine. Test results show that on increasing the catalyst temperature the variations in the outlet NOx concentration are faster and maximal allowable $NH_3$ storage exponentially decreases. For change from a low to high engine load, it can be seen that a few seconds after load-step is required to reach full NOx conversion and the adsorbed amount of $NH_3$ at lower temperature desorb during the next temperature increase, causing $NH_3$ slip. Engine out NOx emission needs to be corrected because NOx emissions just after step load is lower than that of steay state condition.

The Development and Implementation of Model-based Control Algorithm of Urea-SCR Dosing System for Improving De-NOx Performance and Reducing NH3-slip (Urea-SCR 분사시스템의 DeNOx 저감 성능 향상과 NH3 슬립저감을 위한 모델 기반 제어알고리즘 개발 및 구현)

  • Jeong, Soo-Jin;Kim, Woo-Seung;Park, Jung-Kwon;Lee, Ho-Kil;Oh, Se-Doo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.95-105
    • /
    • 2012
  • The selective catalytic reduction (SCR) system is a highly-effective aftertreatment device for NOx reduction of diesel engines. Generally, the ammonia ($NH_3$) was generated from reaction mechanism of SCR in the SCR system using the liquid urea as the reluctant. Therefore, the precise urea dosing control is a very important key for NOx and $NH_3$ slip reduction in the SCR system. This paper investigated NOx and $NH_3$ emission characteristics of urea-SCR dosing system based on model-based control algorithm in order to reduce NOx. In the map-based control algorithm, target amount of urea solution was determined by mass flow rate of exhaust gas obtained from engine rpm, torque and $O_2$ for feed-back control NOx concentration should be measured by NOx sensor. Moreover, this algorithm can not estimate $NH_3$ absorbed on the catalyst. Hence, the urea injection can be too rich or too lean. In this study, the model-based control algorithm was developed and evaluated on the numerical model describing physical and chemical phenomena in SCR system. One channel thermo-fluid model coupled with finely tuned chemical reaction model was applied to this control algorithm. The vehicle test was carried out by using map-based and model-based control algorithms in the NEDC mode in order to evaluate the performance of the model based control algorithm.

Characteristic comparison of sensing materials in mixed potential type NH3 gas sensors for urea-SCR DeNOx system in diesel engine (디젤 엔진 Urea-SCR DeNOx 시스템용 혼합전위 방식 암모니아 가스 센서의 감지물질 특성 비교)

  • Choi, An-Gi;Yang, Young-Chang;Koo, Bon-Chul;Park, C.O.
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.176-183
    • /
    • 2010
  • It is considered that the urea injection DeNOx SCR(selective catalytic reduction) system is the only promising method to satisfy the worldwide NOx emission standards. As for the theoretical aspect, reactants of NO and $NO_2$ with $NH_3$ produce $H_2O$, $N_2$ and $O_2$ which do not harm human beings and environmental as well. The realization of maximum NOx conversion (without using a post oxidation catalyst) is only possible with closed loop controlled urea dosing. It means built-in $NH_3$ gas sensor have to be developed for detecting accurate $NH_3$ concentration for the feedback system. Using YSZ(yttria-stabilized zirconia) as a solid state electrolyte and $In_2O_3$ as a sensing material, this paper aims to study dependable $NH_3$ gas sensor for the promising solution of DeNOx technology, which have a reproducible electric output signal, a high sensitivity and fast response.

A development of reactor design software for De-NOx system using the selective catalytic reduction method (선택적 촉매 환원법을 이용한 De-NOx 시스템의 반응로 설계 전산프로그램 개발)

  • 정경열;오상훈;동은석;이수태;류길수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.187-191
    • /
    • 2002
  • The exhaust gas from electric power stations, incinerators and industrial boilers contains considerable amount of harmful nitric oxide which causes air pollution. Selective catalytic reduction system with ammonia as a reductant(NH$_{3}$ SCR) have been applied to remove NOx since 1970. it is widely accepted that the NH$_{3}$ SCR process is the best method for the removal of NOx. In this paper the design of SCR reactor based on the NOx displacement is considered and the design program of SCR reactor is developed. The newly developed design program for de-NOx system maybe used in practice.

  • PDF

A Study on a Combined DeNOx Process of Plasma Oxidation and $NH_3$ SCR for Diesel Engine (플라즈마 산화와 암모니아 SCR 복합탈질공정의 엔진적용 연구)

  • Song, Young-Hoon;Lee, Jae-Ok;Cha, Min-Suk;Kim, Seock-Joon;Ryu, Jeong-In
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.4
    • /
    • pp.39-46
    • /
    • 2007
  • The technique of $NH_3$ SCR (selective catalytic reduction) assisted by plasma oxidation has been applied to a 2,000 cc diesel engine. The present combined $deNO_x$ process consists of two steps. The first step is that about 50% of emitted NO from the engine is oxidized to $NO_2$ in a plasma oxidation process. The second step is that NO and $NO_2$ are simultaneously reduced to $N_2$ in the $NH_3$ SCR process. The engine test results showed that the $deNO_x$ rates of the present combined process are higher than those of conventional SCR process by 20%. Such a high performance of the combined process is noticeable especially, when the exhaust temperature are relatively low, i.e., $170-220^{\circ}C$. To provide a feasibility of the present technique the effects of operating conditions, such as an electrical input energy, an exhaust gas temperature, an initial NO concentration, and the amount of hydrocarbon addition, were discussed.

  • PDF

De-NOx Characteristics of V2O5 SCR according to the Ratio of TiO2 Crystal Structures

  • Seo, Choong-Kil;Bae, Jaeyoung
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.26-32
    • /
    • 2015
  • The purpose of this study is to investigate the de-NOx performance characteristics according to the $TiO_2$ crystal structures ratio of $V_2O_5$ SCR catalysts. The anatase(100%) SCR catalyst showed the highest desorption peak of 80ppm at about $250^{\circ}C$, and $NH_3$ was not desorbed at $500^{\circ}C$. It can be confirmed that there was many $NH_3$ desorbed at a high temperature among other various crystal structures, which is because the catalyst was more acidized to increase the intensity of acid sites as the content of subacid sulfate ions($NH_2SO_4$) in the rutile phase increases. The anatase/rutile(7%/93%) SCR had the smallest width of de-NOx performance drop according to thermal aging, and had strong durability against thermal aging.

DeNOx Characteristics of Hybrid SNCR-SCR Process in a Pilot Scale Flow Reactor (파일럿 규모 반응기에서 Hybrid SNCR-SCR 공정의 질소산화물 저감 특성)

  • Eom, Won-Hyun;Yoo, Kyung-Seun;Kim, Sung-June
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.89-94
    • /
    • 2011
  • DeNOx characteristics of hybrid SNCR-SCR process have been investigated in a pilot scale flow reactor. DeNOx efficiency of SNCR reaction was about 80% at $970^{\circ}C$ and hybrid SNCR-SCR process showed 92% at $940^{\circ}C$ with NSR = 2.0. Compared to SNCR process alone, hybrid SNCR-SCR process was more effective at cool side, which is lower than $940{^{\circ}C}$. It should be also noted that ammonia slip from hybrid SNCR-SCR process was below 1ppm at the condition of higher space velocity and the required catalyst volume can be decreased to 2/3 of SCR process. Key factors for DeNOx efficiency of hybrid SNCR-SCR process were found to be $NH_3$ concentration and NOx selectivity of urea injected in SNCR process.