• 제목/요약/키워드: $LiBr-H_2O$ Solution

검색결과 62건 처리시간 0.027초

$H_2$O/(LiBr+$CaC1_2$) 3성분계 작동매체의 용해도, 증기압측정 및 듀링 선도, 엔탈피-농도 선도 작성 (Solubility, vapor pressure, duhring and enthalpy-concentration charts of$H_2$O/(LiBr+$CaC1_2$) solution as a new working fluid)

  • 이형래;구기갑;정시영
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.666-673
    • /
    • 1998
  • Solubilities (LiBr+$CaC1_2$) in water were measured at temperatures form 267.51 to 306.17K for $CaC1_2$ (LiBr+$CaC1_2$)=0.24 by mole. Experimental data were correlated with polynomial equations. Average absolute deviations between the measured and calculated values were 0.31% at concentration smaller than 60wt% and 0.41% at concentration larger than 60wt%, respectively. Vapor pressures were measured at temperatures from 296.75 to 436.75K and concentrations from 40 to 70wt%. Vapor pressure data were fitted to a Antoine-type equation and average absolute deviation was 2.98%. The P-T-X chart and H-T-X chart of $H_2O$/(LiBr+$CaC1_2$) system were constructed by using the correlation equations of solubility, vaper pressure, and heat capacity. The P-T-X chart indicates that $H_2O$/(LiBr+$CaC1_2$) system has potential as a possible working fluid for air-cooled absorption chillers.

  • PDF

수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구 (An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube)

  • 설신수;이상용
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.

$LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 LiBr 농도의 영향 (The Effect of LiBr Concentration on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids)

  • 임우조;정기철
    • 한국가스학회지
    • /
    • 제5권4호
    • /
    • pp.33-39
    • /
    • 2001
  • 흡수식냉동기의 작동매체로 사용되고 있는 LiBr수용액 중에서 각 구성재료인 일반구조용 압연강재, 동 및 동합금재인 Ai-Ni bronze의 부식거동에 관한 연구를 하기 위하여, 여러 가지 농도의 LiBr 수용액 중에서 각 재료에 대한 분극실험을 실시하여 부식거동을 고찰한 결과 다음과 같은 결론을 얻었다. 1) 수용액의 LiBr 농도가 증가할수록 각 재료의 분극저항은 낮아지고, 개로전위는 비전 위화되면서 부식전류밀도는 높게 배류된다. 2) 일반구조용 압연강재의 개로전위는 동 및 Al-Ni bronze의 개로전위보다 비전위화되면서 부식전류밀도는 더 높게 배류된다. 3) 동 및 Al-Ni bronze에 대한 $62\%$ LiBr 수용액 중에서의 양극분극은 활성태로 지속되지만, 천연해수 중에서의 양극분극은 활성태가 지속되다가 부동태화전류가 나타난다.

  • PDF

좁은 휜이 달린 경사면을 흐르는 리튬브로마이드 수용액 흡수기에서의 열 및 물질전달 (Coupled Heat and Mass Transfer in Absorption of Water Vapor into LiBr-$H_2O$ Solution Flowing over a Finned Inclined Surface)

  • 조은준;서태범
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.860-867
    • /
    • 2001
  • Absorption of water vapor into LiBr-$H_2O$ O solution flowing over a finned inclined surface is numerically investigated. The momentum, energy, and diffusion equation are numerically solved using a finite difference method. The four different shapes of the wall surfaces are considered to find the best surface for absorption assuming that the wall temperature and the surface tension are constant. The effects of the fin interval and Reynolds number are investigated. Based on the numerical results, it is known that the parabolic surface shows better absorption performance than the other surfaces, and that water vapor absorption increases gradually with decreasing the fin interval.

  • PDF

수평원관상의 LiBr-H$_{2}$O 액막흡수현상 해석 (Analysis of LiBr-H$_{2}$O Film Absorption on a Horizontal Tube)

  • 박일석;최도형
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.670-679
    • /
    • 1996
  • A numerical study for vapor absorption into LiBr-H$_{2}$O solution film flowing over horizontal circular tubes has been carried out. The momentum, energy and diffusion equations, which are parabolized by the boundary- layer approximation, are solved simultaneously for various mass-flow rates and inlet conditions. The results for the velocity, temperature and concentration fields, as well as the heat and mass flux at the free surface are presented. The effects of inlet conditions, i.e., flow rate, temperature and concentration, on the absorption process are also examined and discussed.

LiBr-$H_2O$계 흡수식냉동기의 부식에 미치는 온도의 영향 (The Effect of Temperature on Corrosion of Absorption Refrigeration Systems Using LiBr-$H_2O$ Working Fluids)

  • 임우조;정기철;윤병두;강성수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.92-97
    • /
    • 2001
  • This paper was studied on the effect of temperature on corrosion of absorption refrigeration systems using LiBr-$H_2O$ working fluids. In the fresh water and 62 %lithium bromide solution at $70^{\circ}C$, polarization test of SS 400, Cu(Cl220T-OL) and Ni-Al bronze was carried out. And Polarization behavior, polarization resistance characteristics, corrosion rate(mmpy) and corrosion sensitivity of materials forming absorption refrigeration systems was considered. The main results are as following: As the experimental temperature increase, the change of corrosion rate of Ni-Al bronze become duller than SS 400 and Cu in 62 % lithium bromide solution. Open circuit potential of SS 400 is less noble than that of Cu and Ni-Al bronze in fresh water, but that becomes noble than Cu and Ni-Al bronze in 62 % lithium bromide solution. The corrosion sensitivity of Ni-Al bronze was controlled than that of Cu and SS 400 in 62% LiBr solution.

  • PDF

LiBr/$H_2O$계 흉수기의 흡수촉진에 관한 실험적 연구 (Experimental investigation of enhanced heat and mass transfer toy LiBr/$H_2O$ absorber)

  • 설원실;권오경;윤정인
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.581-588
    • /
    • 1998
  • An experimental study of the absorption process of water vapor into Lithium Bromide solution was performed. For the purpose of development of high performance absorption chiller-heater utilizing Lithium Bromide solution as working fluid, the absorber is the most effective to improve the performance of an absorber because it requires the largest heat transfer area in an absorption chiller-heater system. This paper introduces bare tube and floral tube for the absorber of absorption chiller-heaters. floral tube has higher heat and mass transfer performance than bare tube conventionally used in absorbers and the it is expected to perform high heat and mass transfer. This paper will provide important information on the selection of absorber tubes in commercial absorption chiller -heaters.

  • PDF

Simulation of $H_2O/LiBr$ Triple Effect Absorption Systems with a Modified Reverse Flow

  • Jo, Young-Kyong;Kim, Jin-Kyeong;Kang, Yang-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.114-121
    • /
    • 2007
  • In this study, a modified reverse flow type, one of the triple effect absorption cycles, is studied for performance improvement. The cycle simulation is carried out by using EES(Engineering Equation Solver) program for the working fluid of $H_2O/LiBr$ solution. The split-ratios of solution flow rate, UA of each component, pumping mass flow rate of solution are considered as key parameters. The results show that the optimal SRH (split ratio of high side) and SRL (split ratio of low side) values are 0.596 and 0.521, respectively. Under these conditions, the COP is maximized to 2.1. The optimal pumping mass flow rate is selected as 3 kg/s and the corresponding UAEV A is 121 kW/K in the present system. The present simulation results are compared to the other literature results from Kaita's (2002) and Cho's (1998) triple effect absorption systems. The present system has a lower solution temperature and a higher COP than the Kaita's modified reverse flow, and it also gives a higher COP than the Cho's parallel flow by adjusting split ratios.

헬리컬 흡수기의 열ㆍ물질전달 특성에 관한 실험적 연구 (An Experimental Study on Beat and Mass Transfer Characteristics of Helical Absorber)

  • 권오경;윤재호;윤정인
    • 대한기계학회논문집B
    • /
    • 제28권1호
    • /
    • pp.81-88
    • /
    • 2004
  • In this study, heat and mass transfer characteristics of five components solution (LiBr+Lil+LiNO$_3$+LiCl+$H_2O$) which could be substituted for commonly used LiBr solution are tested using a helical absorber. The arrangement of helical-typed heat exchangers allows to make the system more compact as compared to conventional one. The effects of experimental parameters, such as the solution flow rate, cooling water, solution temperature, solution concentration and surfactant have been investigated in view of the heat and mass transfer. The results of the experiment of heat and mass transfer performance show that five components solution should have 2% higher concentration fur equal absorption capacity of LiBr solution. But considering that five components solution have higher solubility than LiBr solution about 4% high concentration, five components solution could be applied to a small sized water cooled or air cooled absorption chiller/heater. The increase of heat and mass transfer coefficient by surfactant addition is about 25∼30% and 23∼40% respectively.

수평원관상의 LiBr-수용액에 수증기가 흡수될때의 열 및 물질전달 (Coupled Heat and Mass Transfer during the Absorption of Water Vapor into LiBr-H2O Liquid Solution Flowing down the Outside of the Horizontal Cylinder)

  • 이관수;서석청;김영인;박동규
    • 대한설비공학회지:설비저널
    • /
    • 제17권2호
    • /
    • pp.140-149
    • /
    • 1988
  • The problem of heat and mass transfer accompanying the absorption of water vapor into LiBr-$H_2O$ liquid solution flowing over the outside of the horizontal cylinder was theoretically studied to understand the absorption process occuring in the absorber of the absorption heat pump. Numerical results are presented for various quantities of interest relating to temperature, concentration, heat flux and mass flux. Also, the effects of mass flowrate, initial average velocity, and the radius of the cylinder were investigated.

  • PDF