• Title/Summary/Keyword: $L^*a^*b^*$ Color System

Search Result 234, Processing Time 0.024 seconds

Effect of coloring agent dryness on zirconia color (치과용 지르코니아 착색제의 건조정도가 지르코니아 색조에 미치는 영향)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Hae-Jung;Moon, Yun Hee;Kim, Woong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.176-182
    • /
    • 2018
  • One of the most important factor of esthetic prosthesis is the color of the teeth. Zirconia is produced in the process of design, milling, coloring, drying, and sintering. The effect of the drying degree of zirconia colorant on the color tone is examined. For the experiment, a total of 45 zirconia specimens(15 for each) were fabricated by using cad/cam system. The zirconia specimens(L block(LAZOR), Z block(Zircos-E block posterior), A block(AlphaZ)) were then subjected to zirconia sintering in accordance with the manufacturer's instructions, using a chemical coloring agent to Non-drying(0sec), intermediate (10sec), and completely dried (10min) temperature holding times. The color tone was measured using a spectrophotometer. The results were analyzed with a One-way analysis of variance and the Tukey post-hoc test (${\alpha}=.05$) The $L^*$ values of L, A specimens, $a^*$ values of A specimens, and $b^*$ values of Z specimens were not statistically different according to the degree of drying (p>0.05), While the $L^*$ value of Z specimen, $a^*$ value of L, Z specimen, $b^*$ values of L, A specimens were statistically different according to the degree of drying(p <0.05). In conclusion, the drying of zirconia colourants improves zirconia brightness and increases the optical properties of the enamel.

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.

Tooth color changes associated with the bracket bonding and debonding (교정치료 시 브라켓 부착 및 제거에 따른 치아색 변화)

  • Kim, Seok-Pil;Hwang, In-Nam;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.114-124
    • /
    • 2006
  • The purpose of this study was to evaluate the tooth color changes of resin bonding sites and their adjacent sites on orthodontic bracket bonding. Sixty extracted sound premolars were used and the tooth color was recorded according to the CIE $L^*a^*b^*$ color system using a spectrophotometer. The tooth colors of the twenty premolars were measured and compared before bracket bonding and after removal. On a further twenty premolars, the tooth color was measured before and after only primer application. In the change of $L^*$ values, according to the bracket bonding and primer application, the lightness was decreased, and in the change of $a^*\;and\;b^*$ values, the color was changed into a more yellowish color The color differences $({\Delta}E^*)$ were calculated from the $L^*a^*b^*$ values and compared with the standard value of clinical detection $({\Delta}E^*=3.7)$. The color differences between before the bracket bonding and after removal noted exceeded the standard value and those of between before and after the primer application were not larger than the standard value. Toothbrushing was performed after application of the primer to evaluate the color changes according to the primer abrasion. As a control, toothbrushing was performed on the last twenty premolars. The color differences noted were larger than the standard value after toothbrushing. Also, to evaluate the color changes of the tooth which is exposed to sun irradiation after bracket removal, additional photoaging was performed and the color was measured for all teeth. The additional color differences after photoaging were smaller than the standard value. The above results suggest that the tooth color changes after fixed orthodontic treatment.

A Study on Clustering and Color Difference Evaluation of Color Image using HSV Color Space (HSV색공간을 이용한 칼라화상의 클러스터링 및 색차평가에 관한 연구)

  • Kim, Young-Il
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.2
    • /
    • pp.20-27
    • /
    • 1998
  • This paper describes color clustering method based on color difference in the uniform Munsell color space obtained from hue, saturation, and value. The proposed method operates in the uniform HSV color space which is approximated using ${L^*}{a^*}{b^*}$ coordinate system based on the RGB inputs. A clustering and color difference evaluation are proposed by thresholding NBS unit which is likely to Balinkin color difference equation. Region segmentation and isolation process are carried out ISO DATA algorithm which is a self iterative clustering technique. Through the clustering of 2 input images according to the threshold value, satisfactory results are obtained. So, in conclusion, it is possible to extract result of better region segmentation using human color perception of the objects.

  • PDF

COMPARATIVE EVALUATION OF LIGHT-CURED COMPOSITE RESINS BASED ON VITA SHADE BY SPECTROCOLORIMETER (분광색채계측기를 이용한 Vita Shade 광중합형 복합레진의 색상 비교)

  • Cho, Kyoung-Yee;Hwang, In-Nam;Choi, Hong-Ran;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.424-432
    • /
    • 1998
  • To get a satisfactory result in the composite resin restorations, it is necessary to choose correct shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guide or Bioform shade guide, but color differences might be expected even using the same shade in various materials. In this study, five kinds of light-cured composite resins with A2 and B3 shade were used to measure and compare the color each other while one porcelain served as a control. All composite resins (Spectrum TPH (SP), VeridonFil- Photo (VE), Z100 (Z100), Charisma (CH), Prodigy (PRO)) were filled in to the metal mold (12 mm diameter, 2 mm depth), followed by compression, polymerization and polishing with wet sandpaper. The specimens of porcelain were fabricated by using the refractory mold for porcelain. After 24 hours, the specimens were placed on the spectrocolorimeter and spectral reflectance were measured under CIE illuminant D65. After measuring the values of $L^*$, $a^*$, $b^*$ and ${\Delta}E^*$, following results were obtained; 1. The $L^*$, $a^*$ and $b^*$ values of both shade of porcelain specimens showed significantly higher than those of resin specimens(p<0.05). 2. In comparing the resin specimens of the A2 shade, differences were significant except $L^*$ values of SP-CH and PRO-VE, $a^*$ values of the VE-SP and $b^*$ values of the VE-Z100 and SP-PRO(p<0.05), 3. In comparing the resin specimens of the B3 shade, differences were significant except $L^*$ values of PRO-SP, $a^*$ values of the SP-PRO and Z100-VE and b* values of the PRO-SP(p<0.05). 4. In comparing the resin specimens of the A2 shade, color differences between materials (${\Delta}E^*$) showed the lowest value of 1.66, and the highest was 5.16. ${\Delta}E^*$ values of the materials of VE-PRO, CH-PRO, SP-PRO, SP-Z100 and SP-CH were lower than 3.3. 5. In comparing the resin specimens of the B3 shade, the lowest value of the ${\Delta}E^*$ was 0.57 and the highest was 5.92. ${\Delta}E^*$ values of Z100-CH and SP-PRO were lower than 3.3. The present study revealed there was perceptible color difference between materials even if they have the same designated shade based on Vita shade guide. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

  • PDF

INFLUENCE OF THE SURFACE ROUGHNESS ON TRANSLUCENCY AND SURFACE COLOR OF THE DENTAL COMPOSITE RESINS (복합레진의 표면 거칠기에 따른 투명도와 표면 색상의 차이에 관한 연구)

  • Cho Kyu-Jeong;Park Su-Jung;Cho Hyun-Gu;Kim Dong-Jun;Hwang Yun-Chan;Oh Won-Mann;Hwang In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.312-322
    • /
    • 2006
  • The objectives of this study were to evaluate the effect of surface roughness on the surface color and translucency of the composite resins. Two composite resins (Esthet-X, Dentsply, Milford, USA and Charisma, Kulzer, Domagen, Germany) were used to investigate the surface color. Charisma was used to investigate the translucency. 40 disc samples (diameter: 8 mm, thickness: 5 mm) were made by each product to measure the surface color. Polymerized each sample's one side was treated by Sof-Lex finishing and polishing system (Group C, M, F, SF). 40 disc samples (diameter: 6 mm, thickness: 1 mm) were prepared to measure the opacity. 1 mm samples were ground one side with #600, #1000, #1500 and #2000 sandpapers. CIE $L^{*}a^{*}b^{*}$ values of each 5 mm thickness samples, and XYZ values of 1 mm thickness samples on the white and black background were measured with spectrophotometer (Spectrolino, GretagMacbeth, Regensdorf, Switzerland). Mean surface roughness (Ra) of all samples before and after surface treatment was measured using the Surface Roughness Tester SJ-301 (Mytutoyo, Tokyo, Japan). Regardless of type and shade of the composite resin, $L^{*}$ values measured in group C were higher than others (p < 0.05), and $L^{*}$ value decreased as the Ra value decreased except B3 shade of Esthet-X. But there were no significant difference in $a^{*}$ values among groups. In control group and SF, highest $b^{*}$ values were measured (p < 0.05), except B1 shade of Esthet-X. Contrast ratio decreased as the Ra value decreased (p < 0.05). With the above results, difference of surface roughness has influence on surface color and translucency of dental composite resins.

Demosaicing Algorithm by Gradient Edge Detection Filtering on Color Component (컬러 성분 에지 기울기 검출 필터링을 이용한 디모자이킹 알고리즘)

  • Jeon, Gwan-Ggil;Jung, Tae-Young;Kim, Dong-Hyung;Kim, Seung-Jong;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12C
    • /
    • pp.1138-1146
    • /
    • 2009
  • Digital cameras adopting a single CCD detector collect image color by subsampling in three color planes and successively interpolating the information to reconstruct full-resolution color images. Therefore, to recovery of a full-resolution color image from a color filter array (CFA) like the Bayer pattern is generally considered as an interpolation issue for the unknown color components. In this paper, we first calculate luminance component value by combining R, G, B channel component information which is quite different from the conventional demosaicing algorithm. Because conventional system calculates G channel component followed by computing R and B channel components. Integrating the obtained gradient edge information and the improved weighting function in luminance component, a new edge sensitive demosaicing technique is presented. Based on 24 well known testing images, simulation results proved that our presented high-quality demosaicing technique shows the best image quality performance when compared with several recently presented techniques.

COLORIMETRIC ANALYSIS OF EXTRACTED HUMAN TEETH AND FIVE SHADE GUIDES (발거된 자연치와 5종 Shade Guide의 색채 계측기를 이용한 색상 비교)

  • Hwang, In-Nam;Oh, Won-Man
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.769-781
    • /
    • 1997
  • The tristimulus values of 180 extracted maxillary and mandibular anterior teeth were measured by colorimeter. And it were colnverted to Munsell color order system(Hue, Value, Chroma) and CIE $L^*a^*b^*$ color coordinates. The commonly used Vita, and Bioform shade guides, 2 composite resin shade guides(Prisma APH and Z-100), and a glass-ionomer shade guide(Fuji II) were compared with these teeth. At the middle facial surface, color distributions of teeth were Hue(0.56YR to 9.77Y), Value(2.46 to 7.9), and Chroma(0.14 to 2.02). And the aberaged values and standard deviations for $L^*a^*b^*$ were $63.18{\pm}10.44$, $1.11{\pm}1.66$, and $5.79{\pm}2.36$. The shade guide did not match well with the color space of the human teeth. Especially, the lacks of the Yellow-red Hues and higher values were prominent. Compare with other measurements, the Hues of the teeth measured in this study were broadly distributed(most of ranges in Y and YR were included), while the Value and chroma were shown to the lower.

  • PDF

Assessment of Seawater Color by Digital Photographic Imaging (수색표준액과 해면의 디지털 화상 분석에 의한 수색판정)

  • Choi, Sok-Jin;Arakawa, Hisayuki
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.2
    • /
    • pp.171-178
    • /
    • 2009
  • The purpose of this study was the development of a digital water color measurement system using a CCD optical device. Photographs of the standard medium of Forel and Ule water color scales in the laboratory, and one of sea surface above a Secchi disc (Z=SD/2) immersed in seawater were taken. The colors of these pictures were estimated with the value of CIE $L^*a^*b^*$. Water color assessment was conducted with a digital photo-image. In the case of the Forel scale (No. 1-11), the $b^*$ value was so high that the water color number was large. In the Ule scale (No.11-21), the $a^*$ value became high, which is why the number on the water color scale was large. The color of these pictures showed that the $a^*$ value in the Forel scale and the $b^*$ value in the Ule scale increase with the increase of the F value. The $a^*$ value of seawater color was always lower than the one on the Forel and Ule water color scales. This indicates that the color of the scales differs from actual seawater color. It was concluded that water color number can more effectively be assessed by estimating the ${\Delta}Eab^*$ color difference between the water scales and actual seawater color.

EFFECT OF GOLD ELECTRODEPOSIT OF PD-AG, NI-CR ALLOYS ON THE COLOR OF VENERRED RESIN (Pd-Ag 및 Ni-Cr 합금의 금 전착이 전장 레진의 색채에 미치는 영향)

  • Yang, Hong-So;Park, Yeong-Joon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.645-661
    • /
    • 1995
  • As the mechanical property of composite resin improved, composite resin has been widely used esthetic dentistry. In the field of esthetic dentistry, the color of prosthetic material is very important. The purpose of this study was to evaluate the color difference of specimens, by the types of alloys and gold electrodeposit. Experimental groups were as follows : Group Prec : Au-Pt alloy with no gold coating and no resin veneer. Group Semi : Pd-Ag alloy with no gold coating and no resin veneer. Group BAse : Ni-Cr alloy with no gold coating and no resin veneer. Group Gsem : Pd-Ag alloy with no gold coating and no resin veneer. Group Gbas : Ni-Cr alloy with no gold coating and no resin veneer. Group PreR : Resin veneer on the Pd-Ag alloy without gold coating. Group SemR : Resin veneer on the Pd-Ag alloy without gold coating. Group GbsR : Resin veneer on the Ni-Cr alloy with gold coating Group BasR : Resin veneer on the Ni-Cr alloy without gold coating. In this study, colors of metal surfaces and veneered resins were evaluated by the CIE $L^{*}a^{*}b$ system. The results obtained were as follows : 1. different alloy types and gold coating make the $L^{*}a^{*}b$ system. 2. The ${\Delta}E^*$ab value between groups semi and Base was less than 1.5 and there was no $a^*$ and $b^*$ value difference between groups Gsem and Gbas 3. The values of $L^*$ and $a^*$ ain groups GsemR and GbasR were so similar that the ${\Delta}E^*$ab value was as small as 0.58. 4. In resin specimens with gold coated semiprecious or base alloys showed yellower and redder deviation than the resin specimens with precious alloy. 5. The ${\Delta}E^*$ab values between goups PreR-GsemR and groups PreR-GbasR were as small as 2.68 and 2.22 respectively.

  • PDF