• Title/Summary/Keyword: $In(OH)_xS_y$

Search Result 593, Processing Time 0.027 seconds

One Alpha-hydroxycholecalciferol Improves Growth Performance, Tibia Quality, and Meat Color of Broilers Fed Calcium- and Phosphorus-Deficient Diets

  • Han, J.C.;Wang, Y.L.;Qu, H.X.;Liang, F.;Zhang, J.L.;Shi, C.X.;Zhang, X.L.;Li, L.;Xie, Q.;Wang, C.L.;Yan, Y.Y.;Dong, X.S.;Cheng, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.2
    • /
    • pp.267-271
    • /
    • 2012
  • An experiment was conducted to evaluate the effects of one alpha-hydroxycholecalciferol ($1{\alpha}$-OH $D_3$) on growth performance, tibia quality, and skin and meat color in broilers fed calcium (Ca)- and phosphorus (P)-deficient corn-soybean meal diets. A total of 288 male Ross broilers, at 21 days of age, were randomly assigned to three treatments with eight cages per treatment. Three levels of $1{\alpha}$-OH $D_3$ (0, 5, and 10 ${\mu}g$/kg) were added to a basal diet (0.50% Ca, 0.13% non-phytate phosphorus (NPP), and 0.35% total phosphorus (tP)) without vitamin $D_3$. As a result of this study, the addition of $1{\alpha}$-OH $D_3$ increased body weight gain (p<0.001), feed intake (p = 0.007), feed efficiency (p<0.001), tibia weight (p = 0.002), length (p<0.001), breaking-strength (p = 0.012), ash (p<0.001), Ca (p<0.001), and P content (p = 0.004). Dietary $1{\alpha}$-OH $D_3$ enhanced breast meat yellowness (p = 0.015) and the length and weight of the small intestine of the broilers. Moreover, $1{\alpha}$-OH $D_3$ decreased serum Ca concentration (p = 0.074) and breast meat redness (p = 0.010). These results indicate that the $1{\alpha}$-OH $D_3$ improves growth, tibia quality, and meat color in broilers fed Ca- and P-deficient corn-soybean meal diets.

Survey on ultrafast time resolved X-ray diffraction measurements of crystal structure (X선의 초고속 결정구조 측정법)

  • Koo, Y.D.;Kim, Y.C.;Oh, C.S.
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.13-16
    • /
    • 2014
  • We have surveyed on significant progress in recent developments of accelerator-based pulsed X-ray sources has offered the opportunity for time-resolved studies on fast structure dynamics on the nanometer scale. The required and currently available techniques for time resolved X-ray diffraction measurements using the third-generation synchrotron radiation sources are summarized. Ultrafast X-ray experimental techniques are discussed for femtosecond studies at future synchrotron radiation sources.

Synthesis and Characterization of Tetrathiafulvalene (TTF) and 7,7,8,8-Tetracyanoquinodimethane (TCNQ) Compounds with PdX2(X=CI, NO3and Hexafluoroacetylacetonate)

  • Kim, Young-Inn;Jeong, Chan-Kyou;Lee, Yong-Min;Choi, Sung-Nak
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.12
    • /
    • pp.1754-1758
    • /
    • 2002
  • Tetrathiafulvalene(TTF) reacts with $PdCl_2,Pd(NO_3)_2$ and $Pd(hfacac)_2$(hexafluoroacetylacetonate) in ethanol to give $(TTF)_{1.5}PdCl_2$ (1a), $(TTF)_3Pd(NO_3)_2$ (1b) and $(TTF)_4Pd(hfacas)_2$ nd (1c), respectively. $PdCl(TCNQ)_{2.5}{\cdot}CH_3OH(2a)$was obtained from the reaction of $PdCl_2$ with LiTCNQ in methanol via the partial replacement of $Cl^-$ in $PdCl_2$ by $TCNQ^-$anion, whereas the total substitution of the labile $NO_3^-$ in $Pd(NO_3)_2$ yielded pd(TCNQ)·$CH_3OH$ (2b). $Pd(hfacac)_2(TCNQ)_2\cdot3CH_3OH$ (2c) was obtained from $Pd(hfacac)_2$ and LiTCNQ in methanol. The prepared compounds were characterized by spectroscopic (IR, UV, XPS) methods and magnetic (EPR, magnetic susceptibility) studies. The powdered electrical conductivities (${\sigma}_{rt}$) of the prepared compounds at room temperature were about~$10^{-7}S{\cdot}cm^{-1}$. The effective magnetic moments were lass than the spin-only value of one unpaired electron and no EPR signals from Pd metal ions were observed in any of the compounds, indicating that the Pd ions were diamagnetic and the magnetic moments arose from$(TTF)_n$ or $(TCNQ)_n$ moieties. The experimental evidences revealed that the charge transfer had occurred form $(TTF)_n$ moiety to the central Pd metal ion in 1a, 1b and 1c. Thus the TTF donors were ions in 2a and 2b were diamagnetic Pd(II) oxidation state. In contrast, the Pd metal ion was oxidized to Pd(IV) state in 2c as a result of an addition of $TCNQ^-$anion to $Pd(hfacac)_2$ in methanol. The oxidation states of the Pd metal ions were confirmed using the x-ray photoelectron spectroscopy.

Kinetics and Mechanism of Alkaline Hydrolysis of [(Methoxy)(p-substituted styryl)-carbene] Pentacarbonyl Chromium(0) Complexes in Aqueous Acetonitrile

  • Shin, Gap-Cheol;Hwang, Jae-Young;Yang, Ki-Yull;Koo, In-Sun;Lee, Ik-Choon
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.1981-1985
    • /
    • 2005
  • Kinetic studies have been performed for alkaline hydrolysis of a series of [(methoxy)(p-substituted styryl)carbene]pentacarbonyl chromium(0) complexes ($(CO)_5$Cr=$C(OCH_3)CH=CHC_6H_4X$, X = p-$OCH_3$, p-$CH_3$, H, p-Cl, p-$NO_2$). Second-order rate constants $(k_{{OH}^-})$ for the alkaline hydrolysis in 50% acetonitrile-water(v/v) were determined spectrophotometrically at various temperatures. At a low pH region (pH < 7.5), the observed rate constant $(k_{obs})$ remained constant with a small value, while in a high pH region (pH > 9.5), $k_{obs}$ increases linearly with increasing the pH of the medium. The second-order rate constants $(k_{{OH}^-})$ increase as the substituent X changes from a strong electron donating group to a strong electron withdrawing group. The Hammett plot obtained for the alkaline hydrolysis is consisted of two intersecting straight lines. The nonlinear Hammett plot might be interpreted as a change in the rate-determining step. However, the fact that the corresponding Yukawa-Tsuno plot is linear with $\rho$ and r values of 0.71 and 1.14, respectively indicates that the nonlinear Hammett plot is not due to a change in the rate-determing step but is due to ground-state stabilization through resonance interaction. The positive $\rho$ value suggests that nucleophilic attack by $OH^-$ to form a tetrahedral addition intermediate is the rate-determining step. The large negative ${\Delta}S^\neq$ value determined in the present system is consistent with the proposed mechanism.

Photoluminescence of Nanocrystalline CdS Thin Films Prepared by Chemical Bath Deposition

  • Park, Wug-Dong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.4
    • /
    • pp.170-173
    • /
    • 2010
  • Nanocrystalline cadmium sulfide (CdS) thin films were prepared using chemical bath deposition in a solution bath containing $CdSO_4$, $SC(NH_2)_2$, and $NH_4OH$. The CdS thin films were investigated using X-ray diffraction (XRD), photoluminescence (PL), and Fourier transform infrared spectroscopy (FTIR). The as-deposited CdS thin film prepared at $80^{\circ}C$ for 60 min had a cubic phase with homogeneous and small grains. In the PL spectrum of the 2,900 A-thick CdS thin film, the broad red band around 1.7 eV and the broad high-energy band around 2.7 eV are attributed to the S vacancy and the band-to-band transition, respectively. As the deposition time increases to over 90 min, the PL intensity from the band-to-band transition significantly increases. The temperature dependence of the PL intensity for the CdS thin films was studied from 16 to 300 K. The $E_A$ and $E_B$ activation energies are obtained by fitting the temperature dependence of the PL intensity. The $E_A$ and $E_B$ are caused by the deep trap and shallow surface traps, respectively. From the FTIR analysis of the CdS thin films, a broad absorption band of the OH stretching vibration in the range $3,000-3,600\;cm^{-1}$ and the peak of the CN stretching vibration at $2,000\;cm^{-1}$ were found.

Evaluation of the Beam Quality of Intraoral X-ray Equipments Using Intraoral Standard Films (구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가)

  • Lee Sang-Sub;Kwon Hyok-Rak;Sim Woo-Hyoun;Oh Seung-Hyoun;Lee Ji-Youn;Jeon Kug-Jin;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.183-188
    • /
    • 2000
  • Purpose: This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X -ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results: Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANP AS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. Conclusion: HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X -ray equipment should be managed in the planned and organized fashion.

  • PDF

Fabrication and Dielectric Properties of $(Sr_{1-x}Ca_x)TiO_3$ Ceramic Thin Films (($Sr_{1-x}Ca_x)TiO_3$ 세라믹 박막의 제조 및 유전특성)

  • Kim, J.S.;Cho, C.N.;Oh, Y.C.;Shin, C.G.;Kim, C.H.;Song, M.J.;So, B.M.;Choi, W.S.;Lee, J.U.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1496-1498
    • /
    • 2003
  • The $(Sr_{0.85}Ca_{0.15})TiO_3$(SCT) thin films were deposited on Pt-coated electrode (Pt/TiN/$SiO_2$/Si) using RF sputtering method according to the deposition condition. The optimum conditions of RF power and Ar/$O_2$ ratio were 140[W] and 80/20, respectively. Deposition rate of SCT thin films was about 18.75[${\AA}/min$] at the optimum condition. The capacitance characteristics had a stable value within ${\pm}4[%]$. The drastic decrease of dielectric constant and increase of dielectric loss in SCT thin films were observed above 200[kHz].

  • PDF

Magnetism in Ni-W textured substrates for coated conductors

  • Song K. J.;Park Y. M.;Yang J. S.;Kim S. W.;Ko R. K.;Kim H. S.;Ha H. S;Oh S. S.;Park C.;Joo J. H.;Kim C. J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.7-10
    • /
    • 2005
  • The magnetic properties of a series of both annealed (biaxially textured) and as-rolled (non-textured) Ni-xW alloy tapes with compositions x = 0,1,3, and 5 at.$\%$, were studied. Characterization methods included XRD analyses to investigate the biaxial cube texturing of the annealed Ni-W alloy tapes and studies of the magnetization M for both annealed and as-rolled Ni-W alloy tapes. Both the isothermal mass magnetizations M(H) of a series of samples at different fixed temperatures and M(T) in fixed field, employing a PPMS-9 (Quantum Design), were measured. The Ni-W alloys have shown much reduced ferromagnetism as W-content x increases. Both the saturation magnetization Msat and Curie temperature Tc decrease linearly with W-content x, and both Msat and Tc go to zero at critical concentration of Xc - 9.50 at. $\%$ W.

A Study of Co-Combustion Characteristics of North Korean Anthracite and Bituminous Coal in 2 MWe CFBC Power Plant (2 MWe 순환유동층 발전 플랜트에서 유연탄과 북한 무연탄 혼소시험 특성 연구)

  • Han, Keun-hee;Hyun, Ju-soo;Choi, Won-kil;Lee, Jong-seop
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.580-586
    • /
    • 2009
  • In this study, co-combustion characteristics of Chinese bituminous coal and North Korean anthracite were investigated using a 2 MWe scale circulating fluidized bed power plant. At first, the combustion efficiency of bituminous coal of China and Australia as a function of excess air ratio and temperature were observed. The results showed that the combustion efficiency was influenced by particle size and volatile content of coal, the combustion efficiency of Chinese bituminous coal was over 99.5%. The unburned carbon particles from fly ash and bottom ash were a content 5~7% and 0.3%, respectively. The combustion efficiency with the mixture ratio 20% of bituminous coal and anthracite decreased over 5% because of the increase of entrained particles by a small average particle size of anthracite in the combustor. However, the outlet concentration of $SO_2$ and $NO_x$ was not changed remarkably. The concentrations of the typical air pollutants such as $NO_x$ and $SO_2$ were 200~250 ppm($O_2$ 6%), 100~320 ppm($O_2$ 6%) respectively. The outlet concentration of $NO_x$ was decreased to 30~65% with $NH_3$ supplying rate of 2~13 l/min in SCR process. The $SO_x$ removal efficiency was up to 70% by in-furnace desulfurization using limestone with Ca/S molar of approximately 6.5. With wet scrubbing using $Mg(OH)_2$ as absorbent, the $SO_x$ removal efficiency reached 100% under near pH 5.0 of scrubbing liquid.

Method for Rapid Determination and Removal of Nitrogen Oxides in Flue Gases (Ⅰ). Rapid Determination on Nitrogen Oxides (배기가스중 질소산화물의 신속측정법과 그 제거에 관한 연구 (제1보). NO$_x$의 신속 정량법)

  • Yong Keun Lee;Tong Oh Seo;Kee Jung Paeng;Man Koo Kim;Kyu Ja Whang
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.52-60
    • /
    • 1985
  • Oxides of nitrogen (NO$_x$) in exhaust gases was determined by absorbing the gas in alkaline peroxide solution containing 0.03${\%}$ H2O2 and 0.1N NaOH. About 100 ppm of NO$_x$ was rapidly oxidized to NO$_2$ or N$_2$O$_5$ by H$_2$O$_2$ and required a contact time of 2 minutes with the absorbing solution for complete absorption. With vigorous shaking including air or oxygen gas, high concentration of NO$_x$ (>200 ppm) can be absorbed within 30 minutes. The remaining H$_2$O$_2$ affect the absorbance of color solution strongly. However, the excess H$_2$O$_2$ was completely decomposed by zinc powder 0.5g and the sample solution should be adjusted to the pH range 6.1∼6.6 before the reduction so that conversion of nitrate to nitrite ion is possible. The absorbed NO$_x$ is determined colorimetrically by the diazotization-coupling method with sulfonilamide and NEDA as the coupling agent. The sensitivity of the new method was 4.48 ${\times}$ 10$^4$ as molar absorptivity which was high sensitive compared with that obtained for the usual zinc reduction NEDA method with O$_3$. This method was far more rapid, brief and accurate than previously published O$_3$-NEDA method in Korean industrial standard.

  • PDF