• 제목/요약/키워드: $HgI_2$

검색결과 392건 처리시간 0.023초

허혈전후 적출 가토 심근내의 구성 효소의 변화 (Pre-and Post-ishemic Changes of the Constituent Enzymes in Isolated Rabbit's Myocardium)

  • 천수봉;전도환;이재성;김송명
    • Journal of Chest Surgery
    • /
    • 제33권2호
    • /
    • pp.117-124
    • /
    • 2000
  • Background: Nucleoside transport inhibitor(NTI) Keeps AMP, ADP, ATP levels high in myocytes by inhibiting adenosine cataboilsm so that it may preserve the myocardial contractability during ischemia In this study we investigated the effects of cyclic AMP phosphodiesterase inhibor(C-AMP PDSI) and S-P-nitrobenzyl-6 -thioniosine(NBT; a sort of NIT) on myocadial preservation and changes of constituent enzyme. Material and method: Twenty-six isolated rabbit hearts were perfused with Krebs-Henseleit buffer solution for 20 minutes arrested for 20 minutes and ten reperfused for 30 minutes. The following four groups were prepared and hemodynamic changes coronary effluent lactate dehydrogenase (LDH) a-hydroxybutylic accid(a-HBD) levels and myocardial LDH creatine kinase-MB (CK-MB) adenosine deaminase(ADA) a-HBD levels and myocardial LDH creatine kinase-MB (CK-MB) adenosine deaminase(ADA) a-HBD levels were analysed before and after cardiac arest ; Group I(control) ; the heart was only perfused with K-H ; Group II ; the heart was perfused with K-H including C-AMP PDSI(Amrinone 25mg/L); Group III ; the heart was perfused with K-H including NBT(4.19mg/L) ; Group IV ; the heart was perfused with K-H including C-AMP PDSI + NBT. Result : Left venticular developed pressure(LVDP) at 10 minutes of the equilibrium was significantly higher in group III(72.1$\pm$5.3 mmHg p<0.01) and group III(72$\pm$5.6 mmHg P<0.025) as compared with group I (40.8$\pm$4.7mmHg) and LVDP at 20 minutes of the reperfusion was significantly higher in group II(74$\pm$5.3mmHg p<0.01) and group III(72$\pm$5.6mmHg p<0.025) as compared with group I (44.2$\pm$4.6mmHg). Percentage recovery of LVDP at the reperfusion was the highest in group II(123.3%) Percentage recovery of coronary flow at the equilibrium reperfusion were higher in group II(310%, 270%) group III(230%, 290%) group IV(310%, 280%) as compared with group I (100%) respectively. Myocadial LDH level was significant lower in group IV(33495$\pm$1802 IU/gm p<0.04) as compared with group I(48767$\pm$1421 IU/gm) Myocadial CK-MB level was significant higher in group II(74820$\pm$1421 IU/gm) compared with group I (45450$\pm$1737 IU/gm) Myocadial ADA level was significant higher group IV(1215$\pm$8 IU/gm p<0.05) compared with group I(125$\pm$15 IU/gm) but there was no significant difference between group I and group II ,III, IV in changes of coronary effluent LDH, a-HBD levels. Conclusion: C-AMP PDSI solely appears to have a better effect on myocardial preservation after ischemia than NBT but with no synergistic effect and it could keep CK-MB leve high in myocardial tissues.

  • PDF

Determination of Hg22+ Ions Using a Modified Glassy Carbon Electrode with 2,2':6':2''-Terpyridine

  • Kong, Young-Tae;Bae, Yun-Jung;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.346-350
    • /
    • 2002
  • A glassy carbon electrode (GCE) modified with 2,2':6':2”-terpyridine (2,2':6':2”-TPR) using a spin coating method was applied for the highly selective and sensitive analysis of a trace amount of $Hg_2^{2+}$ ions. Various experimental parameters, which influenced the response of the 2,2':6':2”-TPR modified electrode to $Hg_2^{2+}$ ions, were optimized. The linear sweep and differential pulse voltammograms for the 2,2':6':2”-TPR modified electrode deposited with Hg show a well-defined anodic peak at +0.65 V (vs. Ag|AgCl). After a 25 min preconcentration time in an $Hg_2^{2+}$ ion solution (0.1 M acetate buffer, pH 5.0), differential pulse voltammetry(DPV) with 2,2':6':2”-TPR modified electrode shows a linear response between $1.0\;{\times}\;10^{-6}M\;and\;2.0\;{\times}\;10^{-7}M$. The least-square treatment of these data produce an equation of I[${\mu}A$] = 0.031 + 0.005C with r = 0.980(n = 5). The detection limit of this electrode with linear sweep voltammetry and differential pulse anodic voltammetry were $2.0\;{\times}\;10^{-6}M\;and\;8.0\;{\times}\;10^{-8}M$, respectively. The presence of Pb, Fe, Cd, Ti, Ni, Co, Mg, Al, Mn, and Zn did not interfere in the analysis of the $Hg_2^{2+}$ ion. The 2,2':6':2”-TPR modified GCE has been successfully applied in determination trace amounts of Hg in a human urine sample.

Low Systolic Blood Pressure and Mortality From All Causes and Vascular Diseases Among Older Middle-aged Men: Korean Veterans Health Study

  • Yi, Sang-Wook;Ohrr, Heechoul
    • Journal of Preventive Medicine and Public Health
    • /
    • 제48권2호
    • /
    • pp.105-110
    • /
    • 2015
  • Objectives: Recently, low systolic blood pressure (SBP) was found to be associated with an increased risk of death from vascular diseases in a rural elderly population in Korea. However, evidence on the association between low SBP and vascular diseases is scarce. The aim of this study was to prospectively examine the association between low SBP and mortality from all causes and vascular diseases in older middle-aged Korean men. Methods: From 2004 to 2010, 94 085 Korean Vietnam War veterans were followed-up for deaths. The adjusted hazard ratios (aHR) were calculated using the Cox proportional hazard model. A stratified analysis was conducted by age at enrollment. SBP was self-reported by a postal survey in 2004. Results: Among the participants aged 60 and older, the lowest SBP (<90 mmHg) category had an elevated aHR for mortality from all causes (aHR, 1.9; 95% confidence interval [CI], 1.2 to 3.1) and vascular diseases (International Classification of Disease, 10th revision, I00-I99; aHR, 3.2; 95% CI, 1.2 to 8.4) compared to those with an SBP of 100 to 119 mmHg. Those with an SBP below 80 mmHg (aHR, 4.5; 95% CI, 1.1 to 18.8) and those with an SBP of 80 to 89 mmHg (aHR, 3.1; 95% CI, 0.9 to 10.2) also had an increased risk of vascular mortality, compared to those with an SBP of 90 to 119 mmHg. This association was sustained when excluding the first two years of follow-up or preexisting vascular diseases. In men younger than 60 years, the association of low SBP was weaker than that in those aged 60 years or older. Conclusions: Our findings suggest that low SBP (<90 mmHg) may increase vascular mortality in Korean men aged 60 years or older.

청국장으로부터 Angiotensin I 전환효소 저해 Peptide의 분리 (Isolation of Angiotensin I-Converting Enzyme Inhibitory Peptide from Chungkookjang)

  • 송정이랑;유형재;황재성;이동석;김한복
    • 미생물학회지
    • /
    • 제40권4호
    • /
    • pp.355-358
    • /
    • 2004
  • 한국의 전통 대두 발효식품 청국장이 정장, 혈액순환 개선 둥의 기능성식품으로 부각되고 있다. 청국장은 발효가 되면서 미생물, 효소, 다양한 생리활성물질이 크게 증가하며, 그 중에는 peptide류도 포함된다. 청국장 Peptide류의 형성은 SDS-PAGE 분석을 통해 확인할 수 있었다. 청국장의 수용성 아미노산중, Tyr, Gln-Lys, Trp, Gln, Lys-Pro 등이 주요성분으로 발견되었고, Lys-Pro (0.083 mg/100 g 시료)가 HPLC에 의해 분리되었다. Lys-Pro은 angiotensin I-converting enzyme (ACE)저해효과 $(IC_{50}=32.1{\mu}m)$를 지니고 있었다. 고혈압군이 분말청국장 20 g을 복용하고 2시간 지났을 때, 수축기 혈압은 15 mmHg, 이완기 혈압은 8 mmHg떨어지는 강하효과가 있었다. 청국장은 ACE 저해제와 혈압강하효과를 갖고 있기 때문에 혈액순환개선에 상당한 도움을 주는 기능성 식품으로 개발될 수 있을 것이다.

Correlation Between Total Mercury and Methyl Mercury-In Whole Blood of South Korean

  • Jung, Seon A;Chung, Dayoung;On, Jiwon;Moon, Myeong Hee;Lee, Jeongae;Pyo, Heesoo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1101-1107
    • /
    • 2013
  • In this study, total mercury and methyl mercury in whole blood of Korean was analyzed so as to investigate the correlation between total mercury (T-Hg) and methyl mercury (Me-Hg). 4000 whole blood samples were divided in four groups, according to T-Hg concentration in percentile: group I (p25-p50), group II (p50-p75), group III (p75-p95) and group IV (p95-p100). 100 samples were randomly selected from the each group, and Me-Hg concentration was measured. T-Hg concentration in whole blood was analyzed using a Direct Mercury Analyzer-80 and obtained limit of detection (LOD) was $0.2{\mu}gL^{-1}$. Me-Hg concentration was analyzed with ethylate derivatization using headspace-gas chromatography-mass spectrometry, and obtained LOD of methyl mercury was $0.5{\mu}gL^{-1}$. The geometric means of T-Hg and Me-Hg were $6.35{\mu}gL^{-1}$ and $4.44{\mu}gL^{-1}$, respectively, and 71.91% of T-Hg was presented as Me-Hg.

Soaking method & Particle In Binder method를 적용한 Photoconductor materials의 제작방식에 따른 X-ray Detector film 제작 및 전기적 특성평가

  • 이영규;윤민석;김민우;김윤석;정숙희;전승표;박근우;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.72-72
    • /
    • 2009
  • 본 연구에서는 Photoconductor materials 기반의 평판형 X-ray Detector film 제작에 관한 연구를 수행하였다. 기존의 광도전성 물질로 사용되어 오던 비정질 셀레늄(Amorphous seleinum; a-Se) 기반의 디지털 방사선 검출기 보다 높은 신호 및 동작 특성을 가지는 Mercury Iodide(HgI2)와 열적, 전기적 특성이 안정적이며, 소자의 동작특성이 우수한 Lead Oxide(PbO) 기반의 X-ray Detector film의 개발에 있어서 각각 HgI2 및 PbO 두 물질 층을 적정비율에 맞추어 제작함으로써 최적의 X-ray Detector를 구현하고자 하였다. 이는 빠른 영상획득을 통해 기존의 방식이 가지는 문제점을 해결하고 의료기기 디지털화를 구현할 수 있는 차세대 시스템을 개발하고자 하는 것이다. 본 연구에서는 기존의 진공증착법의 두꺼운 대면적 필름의 제조가 어려운 문제점을 해결하고자 Particle In Binder method(PIB) 방법을 이용하여 $3"{\times}3"$사이즈의 두께 $200{\mu}m$의 다결정의 Photoconductor 필름을 제조하여 전기적 특성을 평가하였다. 제작된 필름의 전기적 특성을 dark current, X-선 sensitivity와 SNR(Signal to -Noise Rate) 등을 측정하여 정량적으로 평가 하였다. 기준 실험으로 진행한 DG 2.1 바인더를 사용한 single-HgI2 층에서 보다 높은 sensitivity 값을 보였지만 높은 dark current로 인해 SNR이 떨어지는 결과를 볼 수 있었다. 본 연구에서 제시하는 두 Photoconductor material의 Soaking method를 이용한 실험에서는 single-HgI2에 해당하는 높은 sensitivity 및 저감된 dark current로 인해 높은 SNR 값을 획득하였다. 하지만 습도와 같은 주변 환경에 의한 재현성 문제로 인한 신호값의 불안정성에 대한 문제점도 남아 있으므로, 차후 최적화된 material 제작 공정을 위한 연구가 꾸준히 진행 되어져야 할 것이다.

  • PDF

디메틸술폭시드 속에서 1,5-디페닐카르보히드라지드의 카드뮴 (II) 및 구리 (II) 착물에 대한 폴라로그래피적 거동 (Polarographic Behavior of Cadmium (II) and Copper (II) Complexes of 1,5-Diphenylcarbohydrazide in Dimethylsulfoxide)

  • 최칠남
    • 대한화학회지
    • /
    • 제30권1호
    • /
    • pp.51-56
    • /
    • 1986
  • 디메틸술폭시드 속에서 카드뮴(II)과 구리(II)의 1,5-diphenylcarbohydrazide 錯物의 性質을 直流 폴라로그래프로 調査한 結果 各 錯物의 電極過程은 다음과 같이 생각된다. Cd(II)${\cdot}$DPH Complex$\frac{e^-}{(E_{\frac{1}{2}}=-0.12V)}$${\to}$Cd(I)${\cdot}$DPH Complex. Cd(I)${\cdot}$DPH Complex$\frac{e^-}{(E_{\frac{1}{2}}=-0.74V)}$${\to}$ Cd(Hg) + nDPH. Cu(II)${\cdot}$DPH Complex$\frac{e^-}{(E_\frac{1}{2}=-0.44V)}$${\to}$Cu(I)${\cdot}$DPH Complex. Cu(I)${\cdot}$DPH Complex$\frac{e^-}{(E_{\frac{1}{2}}=-0.84V)}$${\to}$Cu(Hg) + nDPH. 모든 波는 擴散에만 依存하고, 또 Cd(I)${\cdot}$DPH 착물의 ligand의 자리수는 2이며, 錯物의 解離常數 Kd는 5.12 ${\times}10^{-8}$이었다. 이들 各 錯物의 還元波는 非可逆的이었으며, 디메틸 술폭시드 溶液속에서 錯物들의 還元波는 1電子 2段階임을 알 수 있다.

  • PDF

Two New closo- or nido-Carborane Diphosphine Complexes: Synthesis, Characterization and Crystal Structures

  • Kong, Lingqian;Zhang, Daopeng;Su, Fangfang;Li, Dacheng;Dou, Jianmin
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권7호
    • /
    • pp.2249-2252
    • /
    • 2011
  • Two new carborane complexes containing closo- or nido-carborane diphosphine ligands with the formula: complex $[Hg(7,8-(PPh_2)_2-7,8-C_2B_9H_{10})_2]$ $CH_2Cl_2$ (1) and $[Ag_2({\mu}-Cl)_2(1,2-(P^iPr_2)_2-1,2-C_2B_{10}H_{10})_2]$ (2) have been synthesized and characterized by elemental analysis, 1H and 13C NMR spectroscopy and X-ray structure determination. The X-ray structure analyses revealed that the carborane diphosphine ligand was degraded from closo-1,2-$(PPh_2)_2-1,2-C_2B_{10}H_{10}$ to nido-[$7,8-(PPh_2)_2-7,8-C_2B_9H_{10}]^-$ in complex 1, while the closo nature of the starting ligand $1,2-(P^iPr_2)_2-1,2-C_2B_{10}H_{10}$ was retained in complex 2. In either of the two complexes, the carborane diphosphine ligand was coordinated bidentately to the Hg(II) or Ag(I) center through its two phosphorus atoms, therefore forming a five-member cheating ring between the carborane ligand and the metal center. The coordination geometry of the metal atom is distorted tetrahedron formed by $P_4$ unit in complex 1 and $P_2Cl_2$ unit in complex 2, respectively.