• Title/Summary/Keyword: $H_2S$ removal

Search Result 779, Processing Time 0.027 seconds

Isolation and Characteristics of a Bacterium Removing Chemical Softener, Organo-polysiloxane (화학유연제, Organopolysiloxane 분해세균의 분리 및 특성)

  • Lee, Jung-Hun;Son, Dong-Chul;Kim, Jung;Kim, Hyun-Soo;Yu, Tae-Shick
    • Korean Journal of Microbiology
    • /
    • v.36 no.2
    • /
    • pp.119-124
    • /
    • 2000
  • Thirty three strains of bacteria were isolated from the wastewater and soil contaminated a chemical softener, nrganopolysiloxane. Of these, five strains which showed higher activities for removal this chemical were finally selected for further study. By five strains the 2,500 mgll chemical softener was removed 65.2-67.9% at $37^{\circ}C$ for 5 days by shaking. The pH optimum for growth of W3721, S3712, and S3723 strain were at around pH 7.0-7.5, and W2811, and W2823 strain were at pH 6.5-7.0, respectively. The temperature optimum for growth of W3712 strain was at $37^{\circ}C$ and the other four strains were at TEX>$30^{\circ}C$. The optimal pH and temperature for removal by W3712 strain was initial pH 7.0 and $37^{\circ}C$ respechvely. The W3712 strain was identified and named as Corynebacterium pseudodiphtheriticum W3712 based on its morphological and physiological characteristics.

  • PDF

Enhancement of HF Gas Removal Efficiency of a Scrubber in Semiconductor Manufacturing Process by using ANCOVA Technique (ANCOVA를 이용한 반도체공정 스크러버 HF 가스 제거 개선)

  • Kim, S.J.;Lee, M.;Xu, J.;Lim, S.;Lee, H.;Koo, J.
    • Journal of ILASS-Korea
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2013
  • To comply with the regulation of the reinforcing Clean Air Conservation Act, it is necessary for the semiconductor manufacturers to develop effective low-concentration acid gas abatement system to treat the flue gas. The low-concentration acid gas was found to be harder to deal with than the high-concentration one. In this study, the effect of various potential treatments such as air-assist nozzle spraying, magnetizing the scrubbing water, and adding surfactants to spraying and scrubbing water were investigate through the application of the statistical ANCOVA method, which was proved to be very useful tool when the inlet concentration of acid gas could not be controlled precisely and it affected the removal efficiency of the abatement system.

Adsorption Characteristics of Propylamine on Acid Treated Activated Carbon Fiber (산처리된 활성탄소섬유의 Propylamine의 흡착특성)

  • 양범호;김병구;이영택;김시몽;조시형
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.25 no.2
    • /
    • pp.111-119
    • /
    • 2003
  • In this work, Rayon-based activated carbon fiber(KF-1500) was treated by HN $O_3$ and $H_2$S $O_4$ with different conditions. Specific surface areas(SSA, $S_{BET}$) of the treated activated carbon fibers were decreased by acidic treatment but, total surface acidities and surface functional groups were increased. In spite of the decrease of SSA, propylamin(PPA) adsorption and removal ability by activated carbon fiber(ACF) were increased by nitric acid treatment compared with the raw-ACF(KF-1500) and coconut based activated carbon. However, acidic treated activated carbon fibers were available to removal for various amines and contaminants by adsorption.n.

Comparions of Removal Performances of Divalent Heavy Metals by Natural and Pretreated Zeolites (천연 및 전처리 제올라이트에 의한 2가 중금속 이온 제거능의 비교.검토)

  • 감상규;김덕수;이민규
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.399-409
    • /
    • 1999
  • The three domestic natural zeolites(Yong dong-ri (Y), Daesin-ri (D), Seogdong-ri (S)) harvested in Kyeongju-shi and Pohang-shi, Kyungsangbug-Do, were pretreatd with each of the NaOH, $Ca(OH)_2$ and NaOH following HCl solutions, and the removal performances of divalent haevy metals(Cu, Mn, Pb, and Sr) for natural and pretreated zeolites were investigated and compared in the single and mixed solutions. The natural zeolite-heavy metal system attained the final equilibrium plateau within 20 min, irrespective of initial heavy metal concentration. The heavy metal uptakes increased with increasing initial heavy metal concentration and pH. The heavy metal uptakes for natural zeolites decreased in the following sequences : D>Y>S among the natural zeolites; Pb>Cu>Sr>Mn among the heavy metals. The pretreated zeolites showed higher heavy metal removal performances than natural zeolites and decreased in the order of NaOH, NaOH following HCl, $Ca(OH)_2$ treatment among the pretreatment methods. The heavy metal ion exchange capacity by natural and pretreated zeolites was described either by Freundlich equation or Langmuir equation, but it followed the former better than the latter. The heavy metal uptakes for natural zeolites decreased in the mixed solution, in comparing with those in the single solution and especially, the manganese uptake decreased greatly in the mixed solution. The pretreated zeolites showed the improved removal performances of heavy metals in the mixed solution than in the single solution and the heavy metal uptakes by those in the mixed solution showed the same trends in the single solution among the chemical treatment methods and heavy metals.

  • PDF

Adsorption of Cesium and Strontium Ions in Aqueous Phase Using Porous Metal Organic Frameworks Connected with Functional Group (작용기 적용 다공성 금속 유기골격체를 이용한 수중 세슘 및 스트론튬 이온의 흡착 제거)

  • Lee, Joon Yeob;Choi, Jeong-Hak
    • Journal of Environmental Science International
    • /
    • v.30 no.1
    • /
    • pp.97-108
    • /
    • 2021
  • In the current study, MIL-101(Cr)-SO3H[HCl] as metal-organic frameworks (MOFs) was fabricated via a hydrothermal method. The physicochemical properties of the synthesized material were characterized using XRD, FT-IR, FE-SEM, TEM, and BET surface area analysis. The XRD diffraction pattern of the prepared MIL-101(Cr)-SO3H[HCl] was similar to previously reported patterns of MIL-101(Cr) type materials, indicating successful synthesis of MIL-101(Cr)-SO3H[HCl]. The FT-IR spectrum revealed the molecular structure and functional groups of the synthesized MIL-101(Cr)-SO3H[HCl]. FE-SEM and TEM images indicated the formation of rectangular parallelopiped structures in the prepared MIL-101(Cr)-SO3H[HCl]. Furthermore, the EDS spectrum showed that the synthesized material consisted of the elements of Cr, O, S, and C. The fabricated MIL-101(Cr)-SO3H[HCl] was then employed as an adsorbent for the removal of Sr2+ and Cs+ from aqueous solutions. The adsorption kinetics and adsorption isotherm models were studied in detail. The maximum adsorption capacities of MIL-101(Cr)-SO3H[HCl] for Sr2+ and Cs+ according to pH (3, 5.3~5.8, 10) were 35.05, 43.35, and 79.72 mg/g and 78.58, 74.58, and 169.74 mg/g, respectively. These results demonstrate the potential of the synthesized MOFs, which can be effectively applied as an adsorbent for the removal of Sr2+ and Cs+ ions from aqueous solutions and other diverse applications.

Treatment of palm oil mill effluent using 2 stage reactors combined anaerobic hybrid reactor and anaerobic attached growth reactor (혼합공정과 부착성장공정을 조합한 2단계 혐기 조합공정에서 palm oil mill effluent의 처리)

  • Shin, Chang-Ha;Son, Sung-Min;Jeong, Joo-Young;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.21-29
    • /
    • 2013
  • Present study was conducted to evaluate the performance of Anaerobic Hybrid Reactor (AHR) combined with two types of anaerobic attached growth reactors at mesophilic temperature ($37^{\circ}C$). The reactor was operated at the influent substrate condition of 19,400 mg/L soluble chemical oxygen demand (sCOD). The organic loading rate (OLR) and flow rate were varied in the range of $9.5{\sim}22.5kg/m^3$. day and 10.6 ~ 26.0 L/day respectively since start-up was done. The COD removal efficiency of 93 % was measured at the OLR of $14kg/m^3$. day in AHR. However a reduction in removal efficiency to as low as 85 % could have been related to a combined effect of high concentration suspended solids (SS) concentration over 3,800 mg/L. On the other hand the total COD removal efficiencies were measured to be 96.3 % and 96.2 % for AHR+APF and AHR+ADF respectively. The pH of the POME was adjusted to neutral range by using sodium bicarbonate at the initial stages of the reactor feed, later stages pH adjustment was not required as the pH was maintained in the desired neutral range due to self-buffering capacity of the reactor. The reactor proved to be economically acceptable and operationally stable. The biogas was measured to have $CH_4$ and $CO_2$ with a ratio of 35:65, and methane gas production rate was estimated to be $0.17{\sim}10.269L\;CH_4/g\;COD_{removed}$.

Characterization and Feasibility Study of the Soil Washing Process Applying to the Soil Having High Uranium Concentration in Korea (우라늄 함량이 높은 국내 토양에 대한 토양학적 특성 규명 및 토양세척법의 적용성 평가)

  • Chang, See-Un;Lee, Min-Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.5
    • /
    • pp.8-19
    • /
    • 2008
  • The physicochemical properties of soils having high uranium content, located around Duckpyungri in Korea, were investigated and the lab scale soil washing experiments to remove uranium from the soil were preformed with several washing solutions and on various washing conditions. SPLP (Synthetic Precipitation Leaching Procedure), TCLP (Toxicity Characteristic Leaching Procedure), and SEP (Sequential Extraction Procedure) for the soil were conducted and the uranium concentration of the extracted solution in SPLP was higher than Drinking Water Limit of USEPA (30 ${\mu}g$/L), suggesting that the continuous dissolution of uranium from soil by the weak acid rain may generate the environmental pollution around the research area. For the soil washing experiments, the uranium removal efficiency of pH 1 solution for S2 soil was about 80 %, but dramatically decreased as pH of solution was > 2, suggesting that strong acidic solutions are available to remove uranium from the soil. For solutions with 0.1M of HCl and 0.05 M of ${H_2}{SO_4}$, their removal efficiencies at 1 : 1 of soil vs. washing solution ratio were higher than 70%, but the removal efficiencies of acetic acid, and EDTA were below 30%. At 1 : 3 of soil vs. solution, the uranium removal efficiencies of 0.1M HCl, 0.05 M ${H_2}{SO_4}$, and 0.5M citric acid solution increased to 88%, 100%, and 61% respectively. On appropriate washing conditions for S2 soil such as 1 : 3 ratio for the soil vs. solution ratio, 30 minute for washing time, and 2 times continuous washing, TOC (Total Organic Contents) and CEC (Cation Exchange Capacity) for S2 soil were measured before/after soil washing and their XRD (X-Ray Diffraction) and XRF (X-Ray Fluorescence) results were also compared to investigate the change of soil properties after soil washing. TOC and CEC decreased by 55% and 66%, compared to those initial values of S2 soil, suggesting that the soil reclaimant may need to improve the washed soils for the cultivated plants. Results of XRF and XRD showed that the structural change of soil after soil washing was insignificant and the washed soil will be partially used for the further purpose.

A study of improvement of river water quality(T-P) in pilot-scale operation (파일롯 규모의 운영에 따른 하천수질(T-P) 개선에 관한 연구)

  • Choi, Kyoungsoo;Lee, Chaeyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.5
    • /
    • pp.323-334
    • /
    • 2021
  • Pilot-scale coagulation and sedimentation processes were operated to investigate the T-P (Total phosphorus) removal efficiency. A multiple regression model was also derived to predict the water quality improvement effect with river water characteristics. The inflow rates for the pilot-scale facility were 157-576 m3/day, and the coagulant doses were in the range of 13.7-58.5 mg/L (average 38.9 mg/L) for PAC (Poly alum chloride) and 16.5-62.1 mg/L (average 36.0 mg/L) for alum. The results found that the influent BOD (Biochemical oxygen demand) and T-P concentrations were 4.9 mg/L and 0.115 mg/L, and the removal efficiencies were 52.7% and 59.4%, respectively. T-P removal efficiencies on wet weather days were higher by 10% than dry weather days because influent solids influenced T-P's coagulation process. The pH of river water was 6.9-7.8, and the average pH was 7.3. Although the pH variation was not significant, the trend showed that the treatment efficiency of T-P and PO4-P removal increased. Thus, the pH range considered in this study seems to be appropriate for the coagulation process, which is essential for phosphorous removal. The T-P removal efficiencies were 19.6-93.3% (average 59.2%) for PAC and 16.4-98.5%(average 55.9%) for alum; thus, both coagulants showed similar results. Furthermore, the average coagulant doses were similar at 42.4 mg/L for PAC and 41.3 mg/L for alum. When the T-P concentration of the effluent was compared by the [Al]/[P] ratio, the phosphorus concentration of the treated water decreased with an increasing [Al]/[P] ratio, and the lowest T-P concentration range appeared at the [Al]/[P] ratio of 10-30. A seasonal multiple regression analysis equations were derived from the relationships between 10 independent and dependent variables (T-P concentration of effluent). This study could help lake water quality maintenance, reduce eutrophication, and improve direction settings for urban planning, especially plans related to developing waterfront cities.

Characterization of Coagulation on Synthetic Polymerization Al(III) Inorganic Coagulants for Water Treatment (상수처리용 합성 무기고분자 Al(III)계 응집제의 응집특성)

  • Han Seung-Woo;Jung Chul-Woo;Kang Lim-Seok
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.717-724
    • /
    • 1999
  • This experiment was performed on three parts with prepared coagulants. (1) The characterization of coagulation for PACI coagulants. (2) Comparison of the characterization of coagulation with PAS and PACI coagulants. And (3) Comparison of the characterization of coagulation for the addition of calcium with PACI. Coagulation experiments were conducted with several dosages and pH for each coagulants. For the characterization of coagulation with PACI coagulants, coagulation of Nakdong river waters with three PACls (r=2.0, 2.2, 2.35) showed that the effectiveness of the three coagulants can be considered as r=2.2 > 2.0 > 2.35 which are also the order of higher polymeric aluminum contents. For the comparison of the characterization of coagulation for PAS and PACI coagulants, PAS (r=0.75) coagulants was more effective than other coagulant for the removal of organic matters by sweep floc mechanism with $A;(OH)_{3(S)}$. For comparison of the characterization of coagulation for the addition of calcium with PACI, the presence of divalent cation like $Ca^{2+}$ was supposed to influence the complex formation of organic anions. From the result of test on coagulation at various pH ranges, the PACI was least affected by the coagulation pH, and the addition of calcium to PACI was very effective for the removal of turbidity and organic materials over broader pH range (pH 4-9).

  • PDF

Effect of Calcium Sources for the Treatment of Wastewater Containing High Fluoride (고농도의 불소함유폐수 처리시 칼슘원에 따른 영향)

  • Kim, Seung-Ha;Kim, Keum-Yong;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.307-313
    • /
    • 2011
  • As production of LCD increases, it has become necessary to find an economically efficient way of treating LCD wastewater with high concentration of fluoride. This study focuses on the calcium sources : $CaCl_2$, $Ca(OH)_2$ and $CaCO_3$ for the treatment of the LCD wastewater including high concentration of fluoride. Of course considering removal efficiency and economical aspect, study is continued. Then this study have objective giving aid to field. Consequently, each calcium source's removal efficiency was measured in various pH, calcium dosage, reaction time, and mixing intensity. The optimum operational conditions for $CaCl_2$ were found to be pH of 7, calcium dosage of 0.4[Ca]/[F] (mol / mol), 1 hr of operation and 200 rpm of mixing intensity. For $Ca(OH)_2$, they were pH of 7, calcium dosage of 30 mL/L, 1 hr of operation, and 200 rpm of mixing intensity. While $CaCO_3$ had operational conditions of pH of 4, calcium dosage of 30 mL/L, 1 hr operation and 200 rpm of mixing intensity. But it is recommended to use calcium sources according to various field conditions.