서울市 一部 水道栓水中 重金屬에 관한 調査硏究 (A Study on Heavy Metals at the Consumer s Tap in Seoul)

  • Lee, Byung Mu
    • 한국환경보건학회지
    • /
    • 제10권2호
    • /
    • pp.41-51
    • /
    • 1984
  • This study was performed using samples collected at Myungryundong and at Reservoirs. The purpose of this study was to investigate the differences of water quality between tap and raw water, and to analyse drinking water quality by Fe, Zn from corroded galvanized steel pipe. Results were as follows 1. The older the pipe was, the higher the concentration of Ferrum and Zinc was (t-test : p<0.05). Ferrum and Zinc also exceeded the limits in the older galvanized steel pipe. I think that this comes from the corrosion of pipe. 2. Mercury, Arsenic, Cadmium, Lead, Chomium, Argentum and Aurum not detected in raw water were not detected in tap water. Cobalt, Bismuth and Molybudenum detected in raw water were not detected in tap water. I think that this comes from the quality of raw water, the result of water treatment and the improbability of detection of above metals in water delivery system. 3. Silicon measured 2.4698ppm in raw water, but it ranged from 0.4769ppm to 1.982 ppm in tap water. Manganese measured 0.0638ppm in raw water, but it ranged from 0.0026ppm to 0.0198ppm in 17cases(31%) out of 55samples in tap water. I think that this comes from the water treatment. 4. Aluminium not detected in raw water was found in 17 cases (31%) out of the samples (55cases). It may be considered as the use of coagulants $Al_2(SO_4)_3$. $18H_2O$ and PAC (Poly Aluminium Chloride). The concentration of copper in tap water was much higher in 2 cases(3.6%) out of the samples(55) than that of copper in raw water. I think that this may come from the use of ${CuSO}_4$, the preventive of algae growth, and the result of chlorination, but further study must be necoessary to support the proof.

  • PDF

초초 임계 화력 발전소용 밸브 소재의 산화 거동 (A Study on the Oxidation Behaviors of Power Plant Valve Materials under the Ultra Super Critical Condition)

  • 이준섭;조동율;윤재홍;주윤곤;송기오;조재영;강진호;이선호;엄기원;이종욱
    • 한국표면공학회지
    • /
    • 제42권1호
    • /
    • pp.26-33
    • /
    • 2009
  • Recently ultra-supercritical steam power plants operate at $1000^{\circ}F$ ($538^{\circ}C$) and 3500 psi (24.1 MPa). Thermal efficiency of power plant will be increased about 2% if steam temperature increases from $1000^{\circ}F$ to $1150^{\circ}F$ ($621^{\circ}C$). In this study valve materials Incoloy901 (IC901) and Inconel718 (IN718) were nitrided to improve the surface hardness and solid lubrication function of the valve materials. The hardness of both IC901 and IN718 increased about two times by ion nitriding. IC901, IN718 and their nitrided specimens were corroded under ultra super-critical condition (USC) of $621^{\circ}C$. and 3600 psi (24.8 MPa) for 2000 hours. Oxidations of both IC901 and IN718 were very small due to the formation of protective oxide layer on the surface. But the corrosion resistance of both nitrided specimens decreased because of the formation of non-protective nitride layer of $Fe_{4}N$, $Fe_{2}N$ and CrN on the surface layer. The hardness of both nitrided IC901 and IN718 at $20{\mu}m$ depth from the surface decreased about 30% and 20% respectively by USC 2000 hours.

플라즈마 이온질화 처리된 오스테나이트계 스테인리스강의 해수 내 내식성 평가 (Evaluation of corrosion resistance for plasma ion nitrided austenitic stainless steel in seawater)

  • 정상옥;정광후;양예진;박일초;김성종
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.117-117
    • /
    • 2017
  • 오스테나이트계 스테인리스강의 기계적 특성 향상을 위해 열화학적 표면처리 방법으로 공정 후 재료의 변형이 없고 친환경적인 플라즈마 이온질화 기술이 널리 사용되고 있다. 특히 대략 $450^{\circ}C$이하에서 플라즈마 이온질화 처리 시 S상이라 불리는 expanded austenite 생성에 기인하여 내식성이 향상시키는 것으로 알려져 있다. 그러나 이전의 연구 결과 증류수, HCl, $H_2SO_4$ 등의 실험 용액에 따라 동일한 공정 온도에 대하여 다른 부식 특성을 나타냈으며, 내식성이 확보되는 온도 또한 다른 결과를 얻었다. 이처럼 적용 환경에 따라 다른 부식 경향을 보이고 있으나, 해양 환경에 사용될 해수에서의 부식 저항성에 대한 명확한 규명은 이루어지지 않고 있다. 따라서 본 연구는 해양환경에 보편화되어 있는 오스테나이크계 스테인리스강을 선정하여 다양한 온도에서 플라즈마 이온질화 처리 후 전기화학실험을 통해 온도 변화에 따른 부식 특성을 분석하였다. 플라즈마 이온질화는 25% 질소와 75% 수소의 비율로 $350{\sim}500^{\circ}C$의 온도 조건에서 10시간 동안 처리하였다. 플라즈마 이온질화 처리 후 마이크로 경도 계측과 X-선 회절(X-ray diffraction, XRD) 분석을 통해 온도 변화에 따른 금속 표면에 형성된 질화물의 기계적 조직학적 특성을 분석하였다. 또한 모재 및 다양한 온도에서 플라즈마 이온질화 처리된 재료에 대하여 $2{\times}2cm$(노출면적 $1cm^2$) 시편을 제작하여 전기화학적 부식 실험을 수행하여 부식 특성을 상호 비교 분석하였다. 전기화학적 부식 실험은 침적실험, 동전위 양극 음극 분극 실험을 실시하여 전위 변화에 따른 전류밀도 추이를 분석하여 부식 경향을 파악하였다. 그리고 전기화학 실험 후 손상부의 SEM 관찰과 손상 깊이 분석 및 무게 감소량 계측을 통한 종합적인 분석을 통해 온도-부식 경향의 상관관계를 규명하였다. 또한 분극 실험 후 타펠 외삽법으로 부식전위와 부식전류밀도를 구하여 미처리된 재료 및 플라즈마 이온질화 온도 변화에 따른 상대적 부식 속도를 예측하였다.

  • PDF

증기발생기 2차측 제철화학세정액의 고온적용 (High Temperature Application of Iron Removal Chemical Cleaning Solvent in the Secondary Side of Nuclear Steam Generators)

  • 허도행;이은희;정한섭;김우철
    • Nuclear Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.140-148
    • /
    • 1994
  • 원전 증기발생기 2차측 제철 화학세정을 기존의 93$^{\circ}C$ 표준공정보다 고온인 1$25^{\circ}C$에서 검증시험을 수행하였다. 원전 증기발생기를 1$25^{\circ}C$에서 화학 세정한다는 가정아래 현장세정 조건을 결정하고 이를 다시 모사하여 3l 용량의 소형 검증시험 조건을 결정하였다. 1 gallon 용량의 316 스텐레스강 압력용기를 반응용기로 사용하는 화학세정 시험장치에서 검증시험을 수행하여 스러지 용해거동, 모재 부식률, 세정제 화학조성 변화거동 등을 측정하였다. 1$25^{\circ}C$ 검증시험 결과에서 93$^{\circ}C$ 표준공정보다 세정시간을 절반이하로 단축시키고도 더 효율적인 세정효과를 얻을 수 있을 뿐만이 아니라 2차측 모재의 부식률도 감소함을 확인할 수 있었다. 그러나 고온 세정공정은 아직 현장적용 경험이 없고, 별도의 외부순환 세정 장치를 이용하는 93$^{\circ}C$ 표준공정과는 달리 주냉각재의 잠열로 2차측을 가열하므로 세정이 완료될 때까지 주냉각 펌프를 계속 가동하여야 하는 단점이 있다. 가동중인 증기발생기에 대한 화학세정을 수행할 때 93$^{\circ}C$ 표준공정과 고온공정의 장 단점을 신중히 검토하여 최적공정을 적용하여야 할 것이다.

  • PDF

Ti-6Al-4V 합금에 2nd ATO 처리 후 플라즈마 전해 산화법에 의한 생체활성표면형성 (Formation of Bioactive Surface by PEO-treatment after 2nd ATO Technique of Ti-6Al-4V Alloy)

  • Lim, Sang-Gyu;Cho, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.74-74
    • /
    • 2018
  • Ti-6Al-4V alloys have been widely used as orthopedic materials because of their excellent corrosion resistance and mechanical properties. However, it does not bind directly to the bone, so it requires a surface modification. This problem can be solved by nanotube and micropore formation. Plasma electrolytic oxidation (PEO) treatment for micropore, which combines high-voltage spark and electrochemical oxidation, is a new way of forming a ceramic coating on light metals such as titanium and its alloys. This method has excellent reproducibility and can easily control the shape and size of the Ti alloy. In this study, formation of bioactive surface by PEO-treatment after $2^{nd}$ ATO technique of Ti-6Al-4V alloy was invesgated by various instrument. Nanotube oxide surface structure was formed on the surface by anodic oxidation treatment in 0.8 wt.% NaF and 1M $H_3PO_4$ electrolytes. After nanotube formation, nanotube layer was removed by ultrasonic cleaning. PEO-treatment was carried out at 280V for 3 minutes in the electrolytic solution containing the bioactive substance (Mg, Zn, Mn, Sr, and Si). The surface of Ti-6Al-4V alloy was observed by field emission scanning electron microscopy (FE-SEM, S-4800 Hitachi, Japan). An energy dispersive X-ray spectrometer (EDS, Inca program, Oxford, UK) was used to analyze the spectra of physiologically active Si, Mn, Mg, Zn, and Sr ions. The PEO film formed on the Ti-6Al-4V alloy surface was characterized using an X-ray diffractometer (TF-XRD, X'pert Philips, Netherlands). It is confirmed that bioactive ions play an essential role in the normal bone growth and metabolism of the human skeletal tissues.

  • PDF

전침 시술시 침 재료에 따른 부식성 평가 (The Corrosiveness Evaluation according to the Needle Material in the Electroacupuncture Operation)

  • 권오상;최광호;조성진;류연희;최선미;이상훈
    • Korean Journal of Acupuncture
    • /
    • 제29권2호
    • /
    • pp.216-223
    • /
    • 2012
  • Objectives : Electroacupuncture is widely used because of its diverse curative influence. However, its electrical safety is not guaranteed when applied on the human body. Therefore, in this study, we did research on the corrosiveness of electroacupuncture when applied on the body fluid. Methods : We did research using acupuncture needles which were made of STS304 or STS316 and which were coated or not coated in silicone. They were 0.25 mm in diameter and 40 mm in length. We immersed them to the depth of about 1cm in Hank's Solution and gave a stimulus in 120 Hz for 60 minutes. Then, we measured the pH of Hank's solution and mass of needles and observed their shape. Results : Acupuncture needles which were made of STS304 corroded more easily than those which were made of STS316 when they were applied on the human body. Acupuncture needles which were coated in silicone corroded much more easily than those which were not coated in silicone when they were applied on the body fluid. Conclusions : In this study, we did research on the corrosiveness of electroacupuncture when it is applied on the body fluid using several acupuncture needles. We made a conclusion that when acupuncture needles were applied on the body fluid, the coated one made of STS304 corrodes more easily than the uncoated one made of STS316. We hope that additional further researches on the effect of the corrosiveness of an acupuncture needle will be carried out.

Selective Etching of Magnetic Layer Using CO/$NH_3$ in an ICP Etching System

  • Park, J.Y.;Kang, S.K.;Jeon, M.H.;Yeom, G.Y.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.448-448
    • /
    • 2010
  • Magnetic random access memory (MRAM) has made a prominent progress in memory performance and has brought a bright prospect for the next generation nonvolatile memory technologies due to its excellent advantages. Dry etching process of magnetic thin films is one of the important issues for the magnetic devices such as magnetic tunneling junctions (MTJs) based MRAM. CoFeB is a well-known soft ferromagnetic material, of particular interest for magnetic tunnel junctions (MTJs) and other devices based on tunneling magneto-resistance (TMR), such as spin-transfer-torque MRAM. One particular example is the CoFeB - MgO - CoFeB system, which has already been integrated in MRAM. In all of these applications, knowledge of control over the etching properties of CoFeB is crucial. Recently, transferring the pattern by using milling is a commonly used, although the redeposition of back-sputtered etch products on the sidewalls and the low etch rate of this method are main disadvantages. So the other method which has reported about much higher etch rates of >$50{\AA}/s$ for magnetic multi-layer structures using $Cl_2$/Ar plasmas is proposed. However, the chlorinated etch residues on the sidewalls of the etched features tend to severely corrode the magnetic material. Besides avoiding corrosion, during etching facets format the sidewalls of the mask due to physical sputtering of the mask material. Therefore, in this work, magnetic material such as CoFeB was etched in an ICP etching system using the gases which can be expected to form volatile metallo-organic compounds. As the gases, carbon monoxide (CO) and ammonia ($NH_3$) were used as etching gases to form carbonyl volatiles, and the etched features of CoFeB thin films under by Ta masking material were observed with electron microscopy to confirm etched resolution. And the etch conditions such as bias power, gas combination flow, process pressure, and source power were varied to find out and control the properties of magnetic layer during the process.

  • PDF

알칼리형 연료전지의 수소극용 Co-Mo 및 Ni-Mo 금속간화합물 전극의 전기화학적 안정성 (Electrochemical Stability of Co-Mo and Ni-Mo Intermetallic Compound Electrodes for Hydrogen Electrode of Alkaline Fuel Cell)

  • 이창래;강성군
    • 전기화학회지
    • /
    • 제2권3호
    • /
    • pp.150-155
    • /
    • 1999
  • [ $H_2-O_2$ ] 알칼리형 연료전지용 수소극으로서 아크융해법으로 제조된 Brewer-Engel type의 Co-Mo$(35\;wt\%)$ 및 Ni-Mo$(35\;wt\%)$ 금속간화합물 전극의 전기화학적 안정성이 조사되었다. $N_2$가스로 용존산소를 제거한 $80^{\circ}C$ 6N KOH 전해질 내에서 금속간화합물 전극의 전기화학적 안정성에 미치는 전해질의 농도 및 온도의 영향이 조사되었다. 또한, AFC의 정상 작동조건하에서는 Co-Mo및 Ni-Mo전극의 전기화학적 안정성에 대한 분극전압(과전압)의 영향이 논의되었다. Co-Mo전극은 Ni-Mo전극에 비하여 낮은 전기화학적 안정성을 보였다. 수소가스 평형전위로부터 낮은 양분극 과전압 하에서 Co-Mo전극에서는 Co와 Mo의 용해가 동시에 일어났다. 그러나, Co는 Mo에 비하여 급격히 용해되었다 높은 양분극 과전압에서는 전극표면에 $Co(OH)_2$ 부동태 피막이 형성되었다. Ni-Mo전극의 경우에는 Mo의 용해반응이 치밀한 $Ni(OH)_2$, 부동태 피막형성에 의하여 억제되어 우수한 전기화학적 안정성을 보였다.

하수처리장 바이오가스를 이용한 발전시 가스엔진의 고장원인 분석 (Analysis of cause of engine failure during power generation using biogas in sewage treatment plant)

  • 김길정;김래현
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.13-29
    • /
    • 2016
  • 본 연구에서는 실제 난지 하수처리장에서 바이오가스를 연료로 사용하여 발전할 때, 가스엔진에서 발생하는 고장 사례에 대한 조사와 분석을 통해 바이오가스 플랜트의 주요 고장원인을 분석하고, 그 대책을 제시하였다. 바이오 가스엔진에 유입되는 바이오 가스 속의 황화수소와 수분 제거설비의 간헐적인 오작동으로 인한 수분이 바이오 가스엔진의 인터쿨러 부식을 초래하였다. 또한 바이오가스 속의 실록산이 이산화규소와 규산염 화합물을 형성하여 피스톤 표면 및 실린더라이너 내벽의 긁힘과 마모 등의 손상을 유발하였다. 연소실과 배기가스 설비에 부착된 물질들은 황화수소와 다른 불순물질이 결합한 것으로 분석되었다. 이러한 원인으로는 바이오 가스 속의 고함량(50ppm이상)의 황화수소가 탈황설비에 장기간 공급되었고, 탈황설비내 활성탄의 파과점 도달에 따른 제거효율 저하 때문에 황화수소가 엔진으로 유입됨으로써 발생한 것으로 사료된다. 또한, 황화수소는 흡착탑의 실록산 제거용 활성탄 기능을 저하시킴으로써 제거되지 않은 실록산 화합물이 엔진으로 유입되어 다양한 형태의 엔진고장을 유발한 것으로 판단된다. 따라서, 황화수소와 실록산, 수분은 바이오 가스엔진 고장의 주요 원인으로 볼 수 있으며, 이 중 황화수소는 고장을 일으키는 다른 물질과 반응하며, 전처리 공정에 중대한 영향을 미치는 물질로 볼 수 있다. 결과적으로, $H_2S$ 제거방법의 최적화가 안정적인 바이오 가스엔진 운영을 위한 필수적인 대책으로 사료된다.

효율적인 양식 모니터링을 향하여: YOLOv7 및 SORT를 사용한 실시간 물고기 감지 및 추적을 위한 지상 기반 카메라 구현 (Towards Efficient Aquaculture Monitoring: Ground-Based Camera Implementation for Real-Time Fish Detection and Tracking with YOLOv7 and SORT)

  • 노태경;하상현;김기환;강영진;정석찬
    • 한국빅데이터학회지
    • /
    • 제8권2호
    • /
    • pp.73-82
    • /
    • 2023
  • 현재 수산업 종사자의 78%를 차지하고 있는 인력 고령화에 따른 노동력 부족 문제를 해결하기 위해 객체 검출 및 추적 알고리즘을 주요 내용으로 하는 스마트 양식 기술에 대한 연구가 활발히 진행되고 있다. 이러한 기술들은 어류의 크기 분석, 행동 패턴 예측 등의 작업이 가능하여 실시간 모니터링 및 자동화 시스템의 구축이 용이할 것으로 기대된다. 본 연구에서는 양식 시설 외부에 설치된 카메라로부터 수집된 영상 데이터를 기반으로 어류 검출 및 추적 알고리즘을 활용하였다. 수중 조건, 암모니아, pH 농도에 따른 카메라 부식 문제로 인한 높은 유지보수 비용 문제를 극복하는 것을 목표로 하였다. 어류 객체 검출을 위해 YOLOv7 모델을 활용한 실시간 모니터링 시스템의 성능을 분석하였고, 어류의 움직임을 추적하기 위해 SORT 알고리즘을 활용하였다. YOLOv7 훈련 결과 PR Curve 기반의 Recall과 Precision 값의 상충 관계를 밝혀내 조명에 의한 물줄기와 그림자의 오검출을 최소화하였음을 알 수 있다. 어류 추적을 위해 우리는 재식별화를 통해 효과적인 추적을 확인하였다. 이러한 연구 결과는 스마트 양식 산업의 운영 효율성을 높이고 양식 시설의 어류 관리 개선을 용이하게 할 것으로 기대된다.