• Title/Summary/Keyword: $H^1$-space

Search Result 2,141, Processing Time 0.027 seconds

Variations of SCN Space in Metabolic Acidosis and Alkalosis in Rabbits (대사성 산증 및 알칼리증에 있어서 SCN 공간의 변화)

  • Earm, Yung-E;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.41-44
    • /
    • 1971
  • Thiocyanate space was determined in 23 bilaterally nephrectomized rabbits in acute metabolic acidosis and alkalosis. Acid-base disturbances were induced by the infusion of 0.3 N HCI or 0.3 N NaOH solution intravenously with the rate of 1 ml/min for 40 to 60 minutes. The blood pressure was monitored throughout the experiment and no changes in blood pressure was confirmed. The following results were obtained. 1. In the saline infused control rabbits, PH was 7.385 with negligible change in pH after the infusion, SCN space was 23.6% of body weight. 2. In the metabolic acidosis group, pH dropped from 7.417 to 7 130 and SCN space was 22.8% of body weight and suggested a negligible change in the extracellular space volume. 3. In the metabolic alkalosis group, pH increased from 7.393 to 7.478 and SCN space was 25.7% of body weight which confirmed a significant increase in the extracellular space volume.

  • PDF

Interim Results of Simultaneous Time Monitoring of SiO and $H_2O$ Masers Toward Water Fountain Sources

  • Kim, Jaeheon;Cho, Se-Hyung;Yoon, Dong-Hwan;Yun, Youngjoo;Byun, Do-Young
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.77.2-77.2
    • /
    • 2013
  • We present the interim results of simultaneous time monitoring observations of $^{28}SiO$ v = 1, 2, J = 1-0, $^{29}SiO$ v = 0, J = 1-0 and $H_2O$ $6_{16}-5_{23}$ maser lines toward 10 known water fountain sources at a post-AGB stage. The observations have been carried out from 2009 June to 2013 September using the 21m single dish radio telescopes of the Korean VLBI Network. From six sources, we detected well separated red- and blue-shifted $H_2O$ maser features with large velocity ranges more than 100 km $s^{-1}$. From four sources, we detected red- and/or blue-shifted $H_2O$ maser features depended on observational epochs. However, we could not detected SiO maser emission from any sources and any epochs. For a representative water fountain source W43A, we obtained $H_2O$ maser spectra at 17 epochs which show a clear bipolar and discontinuous mass ejections. They also showed a periodic change between red-shifted and blue-shifted peaks. However, we need a more regular and short-time interval monitoring observations in order to fix the period and peak intensity variation interval.

  • PDF

Poisson integrals contained in harmonic bergman spaces on upper half-space

  • Yi, Heung-Su
    • Communications of the Korean Mathematical Society
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 1997
  • On the setting of the upper half-space, H of the euclidean n-space, we consider the question of when the Poisson integral of a function on the boundary of H is a harmonic Bergman function and here we give a partial answer.

  • PDF

Synthesis and Molecular Structures of $2-SC_4H_3CH=NN(H)C_6H_5 and (GaMe_2)_2(2-SC_4H_3CH=NNC_6H_5)_2$ ($2-SC_4H_3CH=NN(H)C_6H_5$$(GaMe_2)_2(2-SSC_4H_3CH=NNC_6H_5)_2$의 합성과 분자 구조)

  • 박권일;김용기;조성일
    • Korean Journal of Crystallography
    • /
    • v.11 no.1
    • /
    • pp.46-51
    • /
    • 2000
  • The molecular structures of 2-SC₄H₃CH=NN(H)C/sub 6/H/sub 5/(C/sub 11/H/sub 10/N₂S) and (GaMe₂)₂(2-SC₄H₃CH=NNC/sub 6/H/sub 5/)₂(C/sub 26/H/sub 30/Ga₂N₄S₂) have been determined by X-ray diffraction. Crystallographic data for 2-SC₄H₃CH=NN(H)C/sub 6/H/sub 5/:orthorhombic space group P2₁2₁2₁, a=6.108(1)Å, b=7.593(1)Å, c=22.356(2)Å, V=1037.1(3)ų, Z=4, R=0.0613. Crystallographic data for (GaMe₂)₂(2-SC₄H₃CH=NNC/sub 6/H/sub 5/)₂:monoclinic space group P2₁/n, a=15.996(2) Å, c=9.879(3)Å, β=100.07.(2)°, V=2764.599)ų, Z=4, R=0.0503.

  • PDF

ABSTRACT RELATIVE FOURIER TRANSFORMS OVER CANONICAL HOMOGENEOUS SPACES OF SEMI-DIRECT PRODUCT GROUPS WITH ABELIAN NORMAL FACTOR

  • Farashahi, Arash Ghaani
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.1
    • /
    • pp.117-139
    • /
    • 2017
  • This paper presents a systematic study for theoretical aspects of a unified approach to the abstract relative Fourier transforms over canonical homogeneous spaces of semi-direct product groups with Abelian normal factor. Let H be a locally compact group, K be a locally compact Abelian (LCA) group, and ${\theta}:H{\rightarrow}Aut(K)$ be a continuous homomorphism. Let $G_{\theta}=H{\ltimes}_{\theta}K$ be the semi-direct product of H and K with respect to ${\theta}$ and $G_{\theta}/H$ be the canonical homogeneous space (left coset space) of $G_{\theta}$. We introduce the notions of relative dual homogeneous space and also abstract relative Fourier transform over $G_{\theta}/H$. Then we study theoretical properties of this approach.

Development of 80cm Telescope for Muju County Public Astronomical Observatory

  • Min, S.W.;Kim, S.J.;Jang, M.;Mun, B.S.;Lee, D.H.;Lee, T.H.;Moon, K.S.;Seol, K.H.
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.37.1-37.1
    • /
    • 2008
  • Space Science and Technology Laboratory at Kyung Hee University developed an 80cm Nasmyth telescope with the joint work of Space & Astronomy, Inc. It was set up at Muju county public astronomical observatory in Jeonlabuk-Do. Nasmyth focus system was selected for the telescope to use two focal points by a rotatable tertiary mirror. Focal ratios of the telescope are f10, f5 respectively. Support of the main mirror is made with Lasalle-system. This system uses 24-points in the back side of the mirror that are all resting on small counter-weights and side support is 10-points Boll link Flexible type with 2 Lasalle type. The mount is wheel & disk type Alt-Azimuth design using DC-servo motors. External high accuracy encoder has 47,600 sine-waves/rot. These encoders are used to make real-time corrections on all gearing errors.

  • PDF