전기 인버터 구동 수압 피스톤 펌프 시스템의 효율 성능에 관한 실험적 연구 (An Experimental Study on the Efficiency of the Water Hydraulic Piston Pump System driven by an Electric Inverter)

  • 함영복;박준형;김성동
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.1-7
    • /
    • 2006
  • A water hydraulic pump is likely to have serious problems of high leakage, friction and low energy efficiency. A water hydraulic pump has commonly a fixed displacement type and its outlet flow is adjusted by controlling rotation speed of the pump, which can be implemented by using an electric inverter. This study aims to investigate energy efficiency of the water hydraulic pump system which is driven by an electric inverter. The study is based on the experimental results. The pump which is used in the study shows relatively good efficiency and low leakage, low friction as well. The reasons for the good performance of pump is also investigated.

  • PDF

펌프장내 흡수정 설계 기준 (The Standard of Sump Design in Pump Station)

  • 노형운;오상현;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.589-592
    • /
    • 2005
  • In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Unfortunately in order to design the sump station, the reasonable code or the standards weren't presented yet in Korea. Thus, some researchers had often referred the HI code, JSME code or CEN code to design the sump station. This study aims to prescribe the standard of sump design which were matched well the Korean pump station. Thus, the HI code and TSJ code would be interpreted fully to Korean language, the part of interpreted clauses of the western codes would be selected to compose the standard.

  • PDF

해양심층수 취수를 위한 기포펌프의 적용성 연구 (A Study on Applicability of Air-lift Pump for Deep Seawater pumping)

  • 신필권;김현주;홍석원;최학선
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.13-16
    • /
    • 2004
  • Deep sea water has mid temperature, abundant nutrients and minerals, and good tooter quality. For the purpose of drawing up deep sea water without pump pit construction, tile authors are considering to use air-lift pump. This report describes fundamental experimental investigation for air-lift pump characteristic and improvement in efficiency.

  • PDF

Synthetic Jet 마이크로 에어펌프의 개발 (Development of Synthetic Jet Micro Air Pump)

  • 최종필;김광수;서영호;구보성;장재혁;김병희
    • 소성∙가공
    • /
    • 제17권8호
    • /
    • pp.594-599
    • /
    • 2008
  • This paper presents a micro air pump based on the synthetic jet to supply reactant at the cathode side for micro fuel cells. The synthetic jet is a zero mass flux device that converts electrical energy into the momentum. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. Therefore, it is very important that the design parameters are optimized because of the simple configuration. To design the synthetic jet micro air pump, a numerical analysis has been conducted for flow characteristics with respect to various geometries. From results of numerical analysis, the micro air pump has been fabricated by the PDMS replication process. The most important design factors of the micro air pump in micro fuel cells are the small size and low power consumption. To satisfy the design targets, we used SP4423 micro chip that is high voltage output DC-AC converter to control the PZT. The SP4423 micro chips can operate from $2.2{\sim}6V$ power supply(or battery) and is capable of supplying up to 200V signals. So it is possible to make small size controller and low power consumption under 0.1W. The size of micro air pump was $16{\times}13{\times}3mm^3$ and the performance test was conducted. With a voltage of 3V at 800Hz, the air pump's flow rate was 2.4cc/min and its power consumption was only 0.15W.

초전도 마그네트용 고출력 플럭스 펌프의 특성 (The Characteristics of High Voltage Output Flux Pump for Superconducting Magnet)

  • 최경달;한송엽;츠키지히로시;호시노토모노리;무타이쯔야
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.86-88
    • /
    • 1996
  • Using superconducting magnetic flux pump, thick power leads for a superconducting magnet could be replaced with thin string leads for the excitation magnet to the superconducting flux pump. We have developed a new type flux pump with high voltage output to shorten the charge and discharge time of the load magnet. The test of four stacked disks as the excither for the load magnet has been carried out. This disk type flux pump yielded 70 mV of voltage across its terminal and 10 A of current through 85 mH load magnet which was the field winding of 20 kVA class fully superconducting generator within 12 seconds. This output voltage of the new superconducting flux pump is about 10 times larger than that of the previous work Moreover since it is easy to stack the disks for the superconduction flux pump, the high voltage exciter for the 1H class superconducting magnet would be expected to be made easily.

  • PDF

전기히터식 및 지열원 히트펌프식 농산물 열풍건조기의 에너지 성능 비교 (Energy Performance Comparison of Electric Heater and Geothermal Source Heat Pump type Agricultural Hot Air Dryers)

  • 양원석;김영일;박승태
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.7-12
    • /
    • 2018
  • Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.

Numerical Study of Inlet and Impeller Flow Structures in Centrifugal Pump at Design and Off-design Points

  • Cheah, Kean Wee;Lee, Thong-See;Winoto, S.H.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.25-32
    • /
    • 2011
  • The objective of present work is to use numerical simulation to investigate the complex three-dimensional and secondary flow structures developed at the inlet and impeller in a centrifugal pump at design and off-design points. The pump impeller is shrouded with 6 backward swept blades and with a specific speed of 0.8574. The characteristic of the pump is measured experimentally with straight and curved intake sections. Numerical computation is carried out to investigate the pump inlet flow structures and subsequently the flow field within the centrifugal pump. The numerical results showed that strong interaction between the impeller eye and intake section. Secondary flow structure occurs upstream at the pump inlet has great influence on the pump performance and flow structure within the impeller.

잔열 제거용 40 I/min급 환단면 선형유도전자펌프의 설계 (Design of ALIP with Flowrate of 40 I/min for the Removal of Residual Heat)

  • 김희령;남호윤;김용균;최병해;김종만;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.13-15
    • /
    • 1998
  • EM(Electro Magnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). In the present study. pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.

  • PDF