• Title/Summary/Keyword: $FEV_{1.0}$

Search Result 366, Processing Time 0.024 seconds

Right Ventricular Ejection Fraction using ECG-Gated First Pass Cardioangiography (방사성동위원소 심조영술상 심전도게이트 일회통과법을 이용한 우심실 박출계수)

  • Moon, Young-Hee;Lee, Hae-Giu;Lee, Sung-Yong;Park, Suk-Min;Chung, Soo-Kyo;Yim, Jeong-Ik;Bahk, Yong-Whee;Shinn, Kyung-Sub;Kim, Young-Gyun;Kwon, Soon-Seog
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.135-139
    • /
    • 1993
  • Radionuclide cardioangiography has been widely applied and has played major roles in non-invasive assessment of cardiac function. Three techniques, first-pass, gated first and gated equilibrium methods, have commonly been used to evaluate right ventricular ejection fraction which usually abnormal in the patients with cardiopulmonary disease. It has been known that the gated first pass method is the most accurate method among the three techniques in assessment of right ventricular ejection fraction. The radionuclide right ventricular ejection fraction values were determined in 13 normal subjects and in 15 patients with chronic obstructive pulmonary disease by the gated first pass method and compared with those of the first pass method because there ha,j been no published data of right ventricular ejection fraction by the gated first pass method in Korea. The values of right ventricular ejection fraction by the gated first pass method were compared with the detas from the pulmonary function test performed in the patients with chronic obstructive pulmomary disease. The results were as follows: 1) The values of right ventricular ejection fraction by the gated first pass method were $50.1{\pm}6.1%$ in normal subjects and $38.5{\pm}8.5$ in the patients with chronic obstructive pulmonary disease. There was statistically significant difference between the right ventricular ejection fraction of each of the two groups (p < 0.05). 2) The right ventricular ejection fraction by the gated first pass method was not linearly correlated with $FEV_1$, VC, DLCO, and FVC as well as $P_aO_2$ and $P_aCO_2$ of the patients with chronic obstructive pulmonary disease. We concluded that right ventricular ejection fraction by the gated first pass method using radionuclide cardioangiography may be useful in clinical assessment of the right ventricular function.

  • PDF

Differences of Foot Plantar Pressure Balance and Lung Capacity According to Change of Cervical Posture in Adults (경추 자세변화에 따른 성인의 족저압력 균형 및 폐활량의 차이)

  • Joo, Ha Young;Yang, Jeong Ok;Lee, Joong Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 2020
  • Objective: The purpose of this study was to differences of foot plantar pressure balance and lung capacity according to cervical posture in adults. Method: The subjects consisted of 33 adults in their 20s and 50s who use M centers in B-gu and H-gu, B-City, and they measured foot plantar pressure balance and lung capacity according to cervical posture (cervical normal curvature posture, cervical flexural posture) in adults. Results: In this study, the difference of foot plantar pressure balance according to cervical posture were analyzed. In the difference between left and right foot pressure balance. It was 1.50% increased in the cervical flexural posture than in the cervical normal curvature posture, and a statistically significant difference was observed. In the difference between the anterior and posterior foot pressure balance. It was 4.28% increased in the cervical flexural posture than in the cervical normal curvature posture, and a statistically significant difference was observed. The difference of lung capacity according to cervical posture were analyzed. In the PEF, It was 58.63 l/min decreased in the cervical flexural posture than in the cervical normal curvature posture, and a statistically significant difference was observed. In the FEV1, It was 0.15 ℓ decreased in the cervical flexural posture than in the cervical normal curvature posture, and a statistically significant difference was observed. Conclusion: The results of this study suggest that had a positive effect on differences of foot plantar pressure balance and lung capacity at cervical normal curvature posture in adults. In future research, itis believed that research on the elderly who have collapsed the normal curvature posture due to aging, as well as teenagers whose normal curvature posture due to the use of smartphones, will contribute to the balance of foot pressure and improvement of the right cervical habits. In future studies, it is also believed that it will be necessary to measure lung capacity after performing exercise according to the cervical posture, thereby providing sufficient oxygen during exercise to enhance the persistence and efficiency of the movement.

Thoracoscopic Lung Biopsy for Diffuse Interstitial Lung Disease (미만성 간질성 폐질환에서 흉강경폐생검)

  • Son, Dong-Seop;Jo, Dae-Yun;Yang, Ki-Min
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1232-1236
    • /
    • 1997
  • Diffuse lung disease is amenable to diagnosis by means of clinical evaluation, bronchoalveolar lavage, transbronchial biopsy, and lung biopsy. The recently introduced technique of thoracoscopic wedge biopsy provides the potential advantages of greater selection of biopsy sites and reduced postoperative pain compared with those associated with standard open lung biopsy. Video assisted thoracoscopic lung biopsy was performed in 22 patients for the diagnosis of diffuse lung disease during the period from August 1994 to December 1996, and the following results were obtained: 1. The patients were 14 men and 8 women. The average age was 54.6 years. 2. 13 lung biopsy specimens were obtained from the right lower lobe, 4 from he right upper lobe, 3 from the right middle lobe, 3 from the left upper lobe, and 3 from the left lower lobe. 3. A comparison of pulmonary function tests between preoperative and postoperative values showed no significant differences in FVC, FEVI, and FEVl/FVC(p>0.05). All patients were pathologically diagnosed and the most common disease was usual interstitial pneumonia(8/22). In conclusion, thoracoscopic lung biopsy was a safe and effective diagnostic method of diffuse lung disease.

  • PDF

The Findings of Pulmonary Function Test in Patients with Inhalation Injury (흡입화상 환자에서의 폐기능검사 소견)

  • Kim, Jong Yeop;Kim, Cheol Hong;Shin, Hyun Won;Chae, Young Je;Choi, Chul Young;Shin, Tae Rim;Park, Yong Bum;Lee, Jae Young;Bahn, Joon-Woo;Park, Sang Myeon;Kim, Dong-Gyu;Lee, Myung Goo;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.653-662
    • /
    • 2006
  • Background: The changes in the pulmonary function observed in burn patients with an inhalation injury are probably the result of a combination of airway inflammation, chest wall and muscular abnormalities, and scar formation. In addition, it appears that prolonged ventilatory support and an episode of pneumonia contribute to the findings. This study investigated the changes in the pulmonary function in patients with inhalation injury at the early and late post-burn periods. Methods: From August 1, 2002, to August 30, 2005, surviving burn patients who had an inhalation injury were enrolled prospectively. An inhalation injury was identified by bronchoscopy within 48hours after admission. Spirometry was performed at the early phase during admission and the recovery phase after discharge, and the changes in the pulmonary function were compared. Results: 37 patients (M=28, F=9) with a total burn surface area (% TBSA), ranging from 0 to 18%, were included. The initial $PaO_2/$FiO_2$ratio and COHb were $286.4{\pm}129.6mmHg$ and $7.8{\pm}6.6%$. Nine cases (24.3%) underwent endotracheal intubation and 3 cases (8.1%) underwent mechanical ventilation. The initial X-ray findings revealed abnormalities in, 18 cases (48.6%) with 15 (83.3%) of these being completely resolved. However, 3 (16.7%) of these had residual sequela. The initial pulmonary function test, showed an obstructive pattern in 9 (24.3%) with 4 (44.4%) of these showing a positive bronchodilator response, A restrictive pattern was also observed in 9 (24.3%) patients. A lower DLco was observed in only 4 (17.4%) patients of which 23 had undergone DLco. In the follow-up study, an obstructive and restrictive pattern was observed in only one (2.7%) case each. All the decreased DLco returned to mormal. Conclusions: Most surviving burn patients with an inhalation injury but with a small burn size showed initial derangements in the pulmonary function test that was restored to a normal lung function during the follow up period.

Comparison of Serum Osteopontin Levels in Patients with Stable and Chronic Obstructive Pulmonary Disease and Exacerbation (안정된 만성 폐쇄성 폐질환환자와 급성 악화상태의 혈중 Osteopontin 농도 비교)

  • Ma, Jeong-Eun;Lee, Seung-Hun;Kim, Yu-Eun;Lim, Su-Jin;Lee, Seung-Jun;Jeong, Yi-Yeong;Kim, Ho-Cheol;Lee, Jong-Deog;Hwang, Young-Sil;Cho, Yu-Ji
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.3
    • /
    • pp.195-201
    • /
    • 2011
  • Background: Osteopontin (Opn) is recognized as an important adhesive bone matrix protein and a key cytokine involved in immune cell recruitment and tissue repair and remolding. However, serum levels of osteopontin have not been evaluated in patients with chronic obstructive pulmonary disease (COPD). Thus, the aim of this study was to evaluate and compare the serum levels of osteopontin in patients experiencing COPD exacerbations and in patients with stable COPD. Methods: Serum samples were obtained from 22 healthy control subjects, 18 stable COPD patients, and 15 COPD with exacerbation patients. Serum concentrations of osteopontin were measured by the ELISA method. Results: Serum levels of osteopontin were higher in patients with acute exacerbation than with stable COPD and in healthy control subjects ($62.4{\pm}51.9ng/mL$, $36.9{\pm}11.1ng/mL$, $30{\pm}11ng/mL$, test for trend p=0.003). In the patients with COPD exacerbation, the osteopontin levels when the patient was discharged from the hospital tended to decrease compared to those at admission ($45{\pm}52.1ng/mL$, $62.4{\pm}51.9ng/mL$, p=0.160). Osteopontin levels significantly increased according to patient factors, including never-smoker, ex-smoker and current smoker ($23{\pm}5.7ng/mL$, $35.5{\pm}17.6ng/mL$, $58.6{\pm}47.8ng/mL$, test for trend p=0.006). Also, osteopontin levels showed a significantly negative correlation with forced expiratory volume in one second ($FEV_1$%) predicted in healthy controls and stable COPD patients (r=-0.389; p=0.013). C-reactive protein (CRP) was positively correlated with osteopontin levels in patients with COPD exacerbation (r=0.775; p=0.002). Conclusion: The serum levels of osteopontin increased in patients with COPD exacerbation and tended to decrease after clinical improvement. These results suggest the possible role of osteopontin as a biomarker of acute exacerbation of COPD.

The Effects of Autologous Blood Pleurodesis in the Pneumothorax with Persistent Air Leak (지속성 기흉에서 자가혈액을 이용한 흉막유착술의 효과)

  • Yoon, Su-Mi;Shin, Sung-Joon;Kim, Young-Chan;Shon, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Chung, Won-Sang;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.724-732
    • /
    • 2000
  • Background : In patients with severe chronic lung diseases even a small pneumothorax can result in life-threatening respiratory distress. It is important to treat the attack by chest tube drainage until the lung expands. Pneumothorax with a persistent air leak that does not resolve under prolonged tube thoracostomy suction is usually treated by open operation to excise or oversew a bulla or cluster of blebs to stop the air leak. Pleurodesis by the instillation of chemical agents is used for the patient who has persistent air leak and is not good candidate for surgical treatment. When the primary trial of pleurodesis with common agent fails, it is uncertain which agent should be used f or stopping the air leak by pleurodesis. It is well known that inappropriate drainage of hemothorax results in severe pleural adhesion and thickening. Based on this idea, some reports described a successful treatment with autologous blood instillation for pneumothorax patients with or without residual pleural space. We tried pleurodesis with autologous bood for pneumothorax with persistent air leak and then we evaluated the efficacy and safety. Methods : Fifteen patients who had persistent air leak in the pneumothorax complicated from the severe chronic lung disease were enrolled. They were not good candidates for surgical treatment and doxycycline pleurodesis failed to stop up their air leaks. We used a mixture of autologous blood and 50% dextrose for pleurodesis. Effect and complications were assessed by clinical out∞me, chest radiography and pulmonary function tests. Results : The mean duration of air leak was 18.4${\pm}$6.16 days before ABP (autologous blood and dextrose pleurodesis) and $5.2{\pm}1.68$ days after ABP. The mean severity of pain was $2.3{\pm}0.70$ for DP(doxycycline pleurodesis) and $1.7{\pm}0.59$ for ABDP (p<0.05). There was no other complication except mild fever. Pleural adhesion grade was a mean of $0.6{\pm}0.63$. The mean dyspnea scale was $1.7{\pm}0.46$ before pneumothrax and $2.0{\pm}0.59$ after ABDP (p>0.05). The mean $FEV_1$ was $1.47{\pm}1.01$ before pneumothorax and $1.44{\pm}1.00$ after ABDP (p>0.05). Except in 1 patient, 14 patients had no recurrent pneumothorax. Conclusion : Autologous blood pleurodesis (ABP) was successful for treatment of persistent air leak in the pneumothorax. It was easy and inexpensive and involved less pain than doxycycline pleurodesis. It did not cause complications and severe pleural adhesion. We report that ABP can be considered as a useful treatment for persistent air leak in the pneumothorax complicated from the severe chronic lung disease.

  • PDF

Formaldehyde Exposure in the Plywood Manufacturing Factory (목재 가공업소에서의 Formaldehyde폭로)

  • Ha, Myung-Wha;Kim, Doo-Hie;Lim, Hyun-Sul;Park, Sang-Hu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.1 s.33
    • /
    • pp.37-44
    • /
    • 1991
  • In the plywood manufacturing factory established in 1979, female 3 workers who had exposed to adhesives containing formaldehyde for more than 48 months of duration suffered from eye, nasal, oral, throat and skin irritation and dyspnea as chief complaints. The actual level of the exposure to formaldehyde were not estimated when the exposed workers started to have above symptoms. The environmental monitoring of workplace was measured on April 25, 1990, and the concentration of formaldehyde revealed 0.2 ppm, however the exhaustive ventilatory system was already installed at that time. Twenty six subjects from entire factory were examined by questionnaire, physical examination and spirometry, etc. on August 22, 1990. Significant difference was observed in symptoms and signs of nasal, oral and throat irritation between the exposed group with longer duration and that with short duration. When the exposed group with longer duration was compared to the group of nonexposed, symptoms and signs of nasal, oral, throat and skin irritaion, chest tightness and dullness were significantly increased in the former group. The results of the spirometric test showed that the forced vital capacity and the forced expiratory volume at 1 second were decreased among the exposed group with longer duration but not significant.

  • PDF

A Study on Changes in Blood Eosinophil, Serum IgE and T Lympocyte Subpopulation after Sochongryongtang to Asthmatic Patients (소청룡탕치료 기관지천식환자의 혈액내 호산구수와 혈청IgE 및 T림프구아형의 변화)

  • Jung, Hee-Jae;Ju, Chang-Yeop;Lee, Jae-Sung;Lee, Kyung-Ki;Rhee, Hyung-Koo;Jung, Sung-Ki;Hwang, Woo-Suck
    • The Journal of Internal Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.83-89
    • /
    • 2002
  • Background : Nowadays asthma is considered to be an inflamatory disease characterized by airborne hyper-responsiveness and pulmonary eosinophilia. Objective : We aimed to identify the effects of Sochongryongtang on blood eosinophil, serum IgE and T lympocyte subpopulation in asthmatic patients. Material and Methods : The subjects consisted of fifteen patients with asthma who had been treated with Sochongryongtang for two weeks from February 2001 through June 2001. Sochongryongtang is herbal decoction which has been used for the traditional therapeutic agent of asthma. Results : The blood eosinophil and serum IgE in a normal controlled group. However, the T lympocyte subpopulation in asthmatic patients was not significantly different from the T lympocyte subpopulation in a normal group. The patients were treated with Sochongryongtang for two weeks. No significant difference in the blood eosinophil, serum IgE and T Iympocyte in the sub population. After treatment with Sochongryongtang for two weeks, FEV 1 increased significantly over 0.5 points out of total scores. Conclusion : This study shows that Sochongryongtang has effects on improvement of pulmonary function and quality of life in asthmatic patients. However, the patients who were treated with Sochongryongtang for two weeks showed no significant difference in the blood eosinophil, serum IgE and T lympocyte subpopulation. Further long-term studies must be made on a large number of asthmatic patients.

  • PDF

Dynamics of pre-shift and post-shift lung function parameters among wood workers in Ghana

  • John Ekman;Philip Quartey;Abdala Mumuni Ussif;Niklas Ricklund;Daniel Lawer Egbenya;Gideon Akuamoah Wiafe;Korantema Mawuena Tsegah;Akua Karikari;Hakan Lofstedt;Francis Tanam Djankpa
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.39.1-39.14
    • /
    • 2023
  • Background: Diseases affecting the lungs and airways contribute significantly to the global burden of disease. The problem in low- and middle-income countries appears to be exacerbated by a shift in global manufacturing base to these countries and inadequate enforcement of environmental and safety standards. In Ghana, the potential adverse effects on respiratory function associated with occupational wood dust exposure have not been thoroughly investigated. Methods: Sixty-four male sawmill workers and 64 non-woodworkers participated in this study. The concentration of wood dust exposure, prevalence and likelihood of association of respiratory symptoms with wood dust exposure and changes in pulmonary function test (PFT) parameters in association with wood dust exposure were determined from dust concentration measurements, symptoms questionnaire and lung function test parameters. Results: Sawmill workers were exposed to inhalable dust concentration of 3.09 ± 0.04 mg/m3 but did not use respirators and engaged in personal grooming habits that are known to increase dust inhalation. The sawmill operators also showed higher prevalence and likelihoods of association with respiratory symptoms, a significant cross-shift decline in some PFT parameters and a shift towards a restrictive pattern of lung dysfunction by end of daily shift. The before-shift PFT parameters of woodworkers were comparable to those of non-woodworkers, indicating a lack of chronic effects of wood dust exposure. Conclusions: Wood dust exposure at the study site was associated with acute respiratory symptoms and acute changes in some PFT parameters. This calls for institution and enforcement of workplace and environmental safety policies to minimise exposure at sawmill operating sites, and ultimately, decrease the burden of respiratory diseases.

The Study for the Relationship of Weight Loss with Plasma Leptin and TNF-α Level in Patients with Chronic Bronchitis and Emphysema (만성기관지염과 폐기종 환자에서 체중감소와 혈중 Leptin 및 TNF-α와의 관계에 대한 연구)

  • Pack, Jong Hae;Park, Ji Young;Park, Hye Jeong;Baek, Suk Hwan;Shin, Kyeong Cheol;Chung, Jin Hong;Lee, Kwan Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.2
    • /
    • pp.199-209
    • /
    • 2003
  • Background : Unexplained weight loss, which commonly occurs in patients with chronic obstructive pulmonary disease(COPD), is important because weight loss is an independent risk factor of mortality and morbidity in these patients. Leptin is known to play an important role in regulating body weight. In addition, the tumor necrosis factor($TNF-{\alpha}$) might also play a potential role in the weight loss experienced in chronic wasting disease. The aim of this study was to determine the influence of plasma leptin and the circulating $TNF-{\alpha}$ system to the difference in the body compositions in patients with COPD. Methods : Spirometry, body composition analysis and the plasma concentrations of leptin, $TNF-{\alpha}$ and a soluble TNF receptor (STNF-R55, -R75) were measured in 31 patients with chronic bronchitis and 10 patients with emphysema. The COPD subtype was classified by the transfer coefficient of carbon monoxide, DLco/VA. Results : The circulating levels of leptin were significantly lower in those patients with emphysema($108.5{\pm}39.37pg/ml$) than those with chronic bronchitis($180.9{\pm}57.7pg/ml$). The circulating levels of sTNF-R55 were significantly higher in the emphysema patients($920.4{\pm}116.4pg/ml$) than in those with chronic bronchitis($803.2{\pm}80.8pg/ml$). There was no relationship between the circulating leptin levels and the activated TNF system in patients with chronic bronchitis and emphysema. However, the circulating leptin levels correlated well with the BMI and fat mass in both patient groups. Conclusion : These results suggest that the weight loss noted in emphysema patients may be associated with the activation of the $TNF-{\alpha}$ system rather than the plasma leptin level.