• 제목/요약/키워드: $Delta^{4PT}$

검색결과 43건 처리시간 0.015초

Eu와 V 동시 도핑에 의한 BiFeO3 박막의 구조와 전기적 특성 (Structural and Electrical Properties of BiFeO3 Thin Films by Eu and V Co-Doping)

  • 장성근;김윤장
    • 한국전기전자재료학회논문지
    • /
    • 제32권3호
    • /
    • pp.229-233
    • /
    • 2019
  • Pure $BiFeO_3$ (BFO) and (Eu, V) co-doped $Bi_{0.9}Eu_{0.1}Fe_{0.975}V_{0.025}O_{3+{\delta}}$ (BEFVO) thin films were deposited on $Pt(111)/Ti/SiO_2/Si(100)$ substrates by chemical solution deposition. The effects of co-doping were observed by X-ray diffraction, Raman spectroscopy, and scanning electron microscopy (SEM). The electrical properties of the BEFVO thin film were improved as compared to those of the pure BFO thin film. The remnant polarization ($2P_r$) of the BEFVO thin film was approximately $26{\mu}C/cm^2$ at a maximum electric field of 1,190 kV/cm with a frequency of 1 kHz. The leakage current density of the co-doped BEFVO thin film ($4.81{\times}10^{-5}A/cm^2$ at 100 kV/cm) was two orders of magnitude lower than of that of the pure BFO thin film.

소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가 (Evaluation of the Utility of a Volumetric Modulated Arc Therapy Specific Patient Quality Assurance using Software-based Quality Assurance System)

  • 강동진;정재용;신영주;민정환;김연래;권경태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.39-45
    • /
    • 2018
  • The purpose of this study is to evaluate the usefulness of a software-based quality assurance system based on Volumetric Modulated Arc Therapy treatment plan. Evaluate treatment plan through the D VH analysis, PTV mean dose ($D_{mean}$) and PTV 95% dose($D_{95}$) compare the MFX based on original treatment plan, Average error rate was $0.9{\pm}0.6%$, $1.0{\pm}0.8%$, respectively. Measuring point dose using phantom and ion chamber, the average error rate between the ionization chamber and MFX was $0.9{\pm}0.7%$, $1.1{\pm}0.7%$ (high dose region), $1.1{\pm}0.9%$, $1.2{\pm}0.7%$ (low dose region). The average gamma though of MFX and $Delta^{4PT}$ is $98.7{\pm}1.2%$, $98.4{\pm}.3%$, respectively. Through this study, A software based QA system that simplifies hardware based QA procedures that involve a lot of time and effort. It can be used as a simple and useful tool in clinical practice.

AAPM TG-119 보고서를 통한 세기조절방사선치료(IMRT)와 부피적세기조절회전치료(VMAT)의 치료 전 환자별 정도관리 (The Patient Specific QA of IMRT and VMAT Through the AAPM Task Group Report 119)

  • 강동진;정재용;김종하;박승;이근섭;손승창;신영주;김연래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권3호
    • /
    • pp.255-263
    • /
    • 2012
  • 본 연구에서는 AAPM TG-119 보고서를 통해 본원에 도입된 세기조절방사선치료(IMRT)와 부피적세기조절회전치료(VMAT)의 치료 전 환자별 정도관리(patient specific QA)를 시행하고자 하였다. 본원의 치료계획장치를 이용해 각각의 치료계획을 수립하여 절대선량은 표적 및 위험장기에 전리함을 이용해 측정하였고 상대선량분포는 $DELTA^{4PT}bi$-planar diode array를 사용하여 측정하였다. 치료계획의 평가는 선량체적히스토그램을 이용하였고 선량검증은 측정값과 계산값을 비교하여 시행하였다. 치료계획평가에서 전립선의 경우에는 두 치료법 모두 표적과 위험장기의 목표선량에 도달하였으며 두경부와 Multi target의 경우, 세기조절방사선치료는 표적에서는 목표선량에 도달하지 못하였지만 부피적세기조절 회전치료는 표적과 위험장기 모두 목표선량에 도달하였다. C-shape(easy)은 두 치료법이 표적과 위험장기 모두 목표선량에 도달하였고, C-shape(hard)의 경우엔, 두 치료법이 표적에서는 목표선량에 도달하였으나 위험장기에서는 목표선량에 도달하지 못하였다. 절대선량평가에서는 세기조절방사선치료의 경우 평균오차율의 평균값이 표적에서 $1.24{\pm}2.06%$, 위험장기에서 $1.4{\pm}2.9%$였고 신뢰구간은 표적에서 3.65%, 위험장기에서 4.39%였다. 부피적세기조절회전치료는 평균오차율의 평균값이 표적에서 $2.06{\pm}0.64%$, 위험장기에서 $2.21{\pm}0.74%$ 였고 신뢰구간은 표적에서 4.09%, 위험장기에서 3.04%로 두 치료법 모두 제안된 허용기준인 표적에서 4.5%, 위험장기에서 4.7% 이내였다. 상대선량평가에서는 세기조절방사선치료의 경우 허용기준을 통과하는 감마인덱스의 평균값은 $98.3{\pm}1.5%$였고 신뢰구간은 3.78%였다. 부피적세기조절회전치료의 경우엔 평균값이 $98.2{\pm}1.1%$였고 신뢰구간은 3.95%로 두 치료법 모두 제안된 허용기준인 7.0% 이내였다. 따라서 이번 연구에서 실시한 시험을 통해 본원의 세기조절방사선치료와 부피적세기조절회전치료가 보고서에서 제안된 허용기준에 모두 부합하고 사용에 적합함을 확인할 수 있었다.