• Title/Summary/Keyword: $Cu^{2+}$ detection

Search Result 184, Processing Time 0.023 seconds

A Study of The $NO_2$ Gas Detect Properties of Tetra-3-hexadecyl-sulphamoylcopperphthalocyanine(HDSM-CuPc) Langmuir-Blodgett Film. (HDSM-CuPc LB막의 $NO_2$ 가스특성에 관한 연구)

  • Han, Y.J.;Kim, H.S.;Yoo, B.H.;Lee, C.H.;Kim, Y.K.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.237-239
    • /
    • 1994
  • The $NO_2$ gas-detection characteristics were investigated using the functional organic Langmuir-Blodgett(LB) film of Tetra-3-hexadecyl-sulphamoylcopperphthalocyanine(HDSM-CuPc). A surface pressure of 30mN/m was obtained as a proper one for a film deposition. A deposited film status was confirmed by electrical and optical methods such as UV/visible absorption spectra and current-voltage(I-V) characteristics. The $NO_2$ gas response experiments under 200ppm concentration show that there is not increment of electrical conductivity in room temperature and is identified by UV/visible absorption spectra. But There are some increments of electrical conductivity in $160^{\circ}C$.

  • PDF

Terahertz Spectral Characteristics of Electrolyte Solutions under Different Magnetic Fields

  • Shao, Siyu;Huang, Haiyun;Peng, Bo;Wang, Guoyang;Ye, Ping;Wang, Jiahui;Su, Bo;Cui, Hailin;Zhang, Cunlin
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.337-343
    • /
    • 2022
  • Microfluidic chips are new devices that can manipulate liquids at the micrometer level, and terahertz (THz) time-domain spectroscopy has good applicability in biochemical detection. The combination of these two technologies can shorten the distance between sample and THz wave, reduce THz wave absorption by water, and more effectively analyze the kinetics of biochemical reactions in aqueous solutions. This study investigates the effects of different external magnetic field intensities on the THz transmission characteristics of deionized water, CuSO4, CuCl2, (CH3COO)2Cu, Na2SO4, NaCl, and CH3COONa; the THz spectral intensity of the sample solutions decrease with increasing intensity of the applied magnetic field. Analysis shows that the magnetic field leads to a change in the dipole moment of water molecules in water and electrolyte solutions, which enhances not only the hydrogen-bond networking ability of water but also the hydration around ions in electrolyte solutions, increasing the number of hydrogen bonds. Increasing the intensity of this magnetic field further promotes the hydrogen-bond association between water molecules, weakening the THz transmission intensity of the solution.

Thermoluminescent Response of Thin LiF:Mg,Cu,Na,Si Detectors to Beta Radiation (얇은 LiF:Mg,Cu,Na,Si 검출기의 베타선장에 대한 TL 반응)

  • Nam, Y.M.;Kim, J.L.;Chang, S.Y.;Cho, H.W.;Kim, H.J.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 1999
  • Thermoluminescent (TL) response characteristics of a thin LiF:Mg,Cu,Na,Si Teflon detectors have been studied for use in beta radiation detection. The detectors were fabricated from a mixture of LiF:Mg,Cu,Na,Si phosphor and Teflon powder which was molded into a thin disk form of $50mg/cm^2$ thickness. These detectors were irradiated to beta fields of $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ sources with a covering of Kapton foil ($2mg/cm^2$) and photon irradiation was carried out with a $^{137}Cs$ source at the Korea Atomic Energy Research Institute (KAERI). Batch uniformity was estimated to be 4.7% and the beta dose response presented linear relationship from 0.1 mGy to 100 Gy. The beta energy responses of thin detectors normalized to $^{137}Cs$ were presented as 0.46, 1.09 and 1.06 for $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ beta rays, respectively. The evaluated values for angular responses were $0.93{\pm}0.03\;(^{147}Pm),\;0.94{\pm}0.04\;(^{204}Tl),\;and\;0.92{\pm}0.05\;(^{90}Sr/^{90}Y)$. The results satisfied well a proposed ISO Standard for beta ray dosimeters.

  • PDF

Amplified fragment length polymorphism fingerprinting analysis of Staphylococcus aureus isolated from bovine mastitis milk (소 유방염 유래 Staphylococcus aureus의 AFLP 지문분석)

  • Kim, Yeon-soo;Kim, Sang-kyun;Hwang, Eui-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.2
    • /
    • pp.157-165
    • /
    • 2001
  • Amplified fragment length polymorphism(AFLP) technique is based on the polymorphism detection through selective PCR amplification of restriction fragments from digested genomic DNA and thus includes the procedures of the total DNA digestion by endonucleases, ligation of adapters to the ends of the fragments, and following the selective amplification of the restricted DNA fragments. This study were aimed to : (1) determine the genetic variability of S aureus strains, (2) estimate genetic diversity within and among these strains, (3) compare phylogenetic relationships among these strains as genetic markers using AFLP techniques. Genomic DNA was digested with a particular combination of three restriction enzymes with specific recognition sites and the DNA fragments were ligated to restriction specific adapters and amplified using the selective primer combinations. In the S aureus strain, the number of scorable AFLP bands detected per each primer combination varied from 29 to 102, with an average of 61.59 using 27 primer combinations. A total of 1,663 markers were generated, 904 bands of which were polymorphic, showing a 33.48% level of polymorphism with these primer combinations. Among the primer combinations, E02/T02, E02/T03, E04/H02, E02/T01 and E04/H03 primer combinations showed a high level of polymorphism with 0.78, 0.76, 0.74, 0.71 and 0.70, respectively. But T03/H01, E01/T02 and E01/T03 primer combinations showed a low level of polymorphism with 0.38, 0.37 and 0.15, respectively, Therefore, the former primer combinations will be the most effective for AFLP analysis of S aureus. In SA1 sub-types the level of polymorphism of S aureus KCTC 1927 was similar to that of S aureus CU 01(0.825) and higher than those of other strains such as S aureus CU 02 (0.715), S aureus KCTC 2199(0.625), S aureus KCTC 1916(0.607) and S aureus KCTC 1621 (0.553). In SA2 sub-types the level of polymorphism of S aureus CU 07 was similar to that of S aureus CU 08(0.935) and higher than those of both S aureus CU 04(0.883) and S aureus CU 05(0.883) and lower than those of S aureus CU 03(0.583). In SA3 subtypes the level of polymorphism of S aureus CU 11 was similar to that of S aureus CU 12(0.913) and lower than that of S aureus CU 15(0.623). The results proved that AFLP marker analysis of S aureus strain could be used to study the epidemiology of mastitis and in addition, common genotype in geographic region could be useful for the development of an effective vaccine or DNA marker for easy diagnosis of mastitis caused by S aureus infection.

  • PDF

Differential Pulse Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol (Nafion-DTPA-Glycerol이 수식된 유리탄소전극을 사용한 미분펄스 전압전류법에 의한 구리(II)이온의 측정)

  • 박찬주;박은희;정근호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.115-122
    • /
    • 2004
  • A glassy carbon electrode(GCE) modified with nafion-DTPA (diethylene triamine-pentaacetic acid)-glycerol is used for the highly selective and sensitive determination of a trace amount of Cu(II). Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu(II), are optimized. The Copper(II) is accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface is characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry(DPV). The electrochemical response is evaluated with respect to concentration of modifier, pH and preconcentration time, quiet time, copper(II) concentration, and other variables. A linear range is obtained in the concentration range 1.0${\times}$10$^{-8}$ M-1.0${\times}$10$^{-6}$ MCu(II) with 7 min preconcentration time. The detection limit(3s) is as low as 2.36${\times}$10$^{-8}$ M (1.50 ppb).

Determination of Copper in Uniformly-Doped Silicon Thin Films by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang;Cha, Myeong;Lee, Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.205-209
    • /
    • 2001
  • Uniformly-doped silicon thin films were fabricated by ion beam sputter deposition. The thin films had four levels of copper dopant concentration ranging between 1 ${\times}$1019 and 1 ${\times}$ 1021 atoms/cm3 . Concentrations of Copper dopants were determined by the isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) to provide certified reference data for the quantitative surface analysis by secondary ion mass spectrometry (SIMS). The copper-doped thin films were dissolved in a mixture of 1 M HF and 3 M HNO3 spiked with appropriate amounts of 65 Cu. For an accurate isotope ratio determination, both the detector dead time and the mass discrimination were appropriately corrected and isobaric interference from SiAr molecular ions was avoided by a careful sample pretreatment. An analyte recovery efficiency was obtained for the Cu spiked samples to evaluate accuracy of the method. Uncertainty of the determined copper concentrations, estimated following the EURACHEM Guide, was less than 4%, and detection limit of this method was 5.58 ${\times}$ 1016 atoms/cm3.

Electrochemical Characteristics of Pencil Graphite Electrode Through Surface Modification and its Application of Non-enzymatic Glucose Sensor (표면 개질된 샤프심 전극의 전기화학적 특성 고찰 및 비효소적 글루코스 센서 활용)

  • Min-Jung Song
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.147-152
    • /
    • 2024
  • Most medical sensors are disposable products. In order to reduce inspection and diagnosis costs, it is more important to develop the inexpensive electrode materials. We fabricated the CuO NPs/PANI/E-PGE as an electrode material for disposable electrochemical sensors and applied it to a non-enzymatic glucose sensor. For surface activation of PGE, pretreatment was performed using chemical and electrochemical methods, respectively. Electrochemical properties according to the pretreatment method were analyzed through chronoamperometry (CA), cyclic voltammetry (CV) and electrochemical impedance (EIS). From these analytical results, the electrochemically pretreated PGE (E-PGE) was finally adopted. The non-enzymatic glucose sensor based on CuO NPs/PANI/E-PGE shows sensitivity of 239.18 mA/mM×cm2 (in a linear range of 0.282~2.112 mM) and 36.99 mA/mM×cm2 (3.75423~50 mM), detection limit of 17.6 μM and good selectivity. Based on the results of this study, it was confirmed that the modified PGE is a high-performance electrode material. Therefore, these electrodes can be applied to a variety of disposable sensors.

"Turn-on" type colorimetric/fluorimetric probe for selective detection of Cu2+ at neutral pH condition

  • Lee, Hyun Jung;Saleem, Muhammad;Lee, Ki Hwan
    • Rapid Communication in Photoscience
    • /
    • v.4 no.4
    • /
    • pp.88-90
    • /
    • 2015
  • The design and development of fluorescent chemosensors have recently been intensively explored for sensitive and specific detection of environmentally and biologically relevant metal ions in aqueous solution and living cells. Herein, we report the photophysical results of rhodamine B based fluorogenic and chromogenic receptor for selective copper detection in the complete organic or mixed aqueous-organic media at neutral pH under ambient condition. The ligand exhibited the remarkable increment in the fluorescence emission and UV-visible absorption signal intensities at 587 and 547 nm, respectively, on induction of copper ion while the ligand solution remain completely silent on addition of varieties of other metal ions.

Electrochemical Non-Enzymatic Glucose Sensor based on Hexagonal Boron Nitride with Metal-Organic Framework Composite

  • Ranganethan, Suresh;Lee, Sang-Mae;Lee, Jaewon;Chang, Seung-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.379-385
    • /
    • 2017
  • In this study, an amperometric non-enzymatic glucose sensor was developed on the surface of a glassy carbon electrode by simply drop-casting the synthesized homogeneous suspension of hexagonal boron nitride (h-BN) nanosheets with a copper metal-organic framework (Cu-MOF) composite. Comprehensive analytical methods, including field-emission scanning electron microscopy (FE-SEM), Fourier-transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), cyclic voltammetry, electrochemical impedance spectroscopy, and amperometry, were used to investigate the surface and electrochemical characteristics of the h-BN-Cu-MOF composite. The FE-SEM, FT-IR, and XRD results showed that the h-BN-Cu-MOF composite was formed successfully and exhibited a good porous structure. The electrochemical results showed a sensor sensitivity of $18.1{\mu}A{\mu}M^{-1}cm^{-2}$ with a dynamic linearity range of $10-900{\mu}M$ glucose and a detection limit of $5.5{\mu}M$ glucose with a rapid turnaround time (less than 2 min). Additionally, the developed sensor exhibited satisfactory anti-interference ability against dopamine, ascorbic acid, uric acid, urea, and nitrate, and thus, can be applied to the design and development of non-enzymatic glucose sensors.

Manufacturing technique and provenance Analysis of Bronze Artefacts excavated from Pungnap earthen fortress (풍납토성 출토 청동유물의 제작기술 및 납 원료의 산지추정)

  • Han, Woo Rim;Kim, So Jin;Han, Min-su;Hwang, Jin-ju;Lee, Eun-woo
    • Korean Journal of Heritage: History & Science
    • /
    • v.48 no.2
    • /
    • pp.110-119
    • /
    • 2015
  • Bronzes, Earthenwares and various artifacts were excavated from Pungnap earthen fortress in the early Baekje age in Korea. This study was performed in order to identify the manufacture technology of bronze artefacts and provenance of lead in bronzes. Microstructure and chemical composition results show that 3 of them are Cu-Sn-Pb alloys in which an intentional lead addition was carried out and one is tin bronze showing straight twin structure within crystal grains. Also $CuFeS_2$ or $Cu_5FeS_4$ was used as raw materials through the detection of S and Fe as trace elements. The lead isotope results could be matched with one of the zones of southern Korea and China on the East Asian map. This results shows that data were plotted either in zone 2 or zone 3 of the South Korean galena map. However, one of bronze artifacts was matched with the zone of Northern China.