• Title/Summary/Keyword: $Cr_{6+}$

Search Result 2,949, Processing Time 0.037 seconds

Corrosion Behavior and Crystal Structure of Zn-Cr Coatings by EB-PVD and Electroplating (EB-PVD법과 전기화학방법으로 형성된 Zn-Cr film의 구조와 부식특성)

  • 최한철
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.6
    • /
    • pp.423-429
    • /
    • 2003
  • It has been investigated corrosion resistance and crystal structure of Zn-Cr coatings fabricated by electroplating method and electron-beam physical vapor deposition method(EB-P VD). The electroplated Zn-Cr alloy consists mainly of η'-Zn phase for the lower Cr content than 7.9 wt% Cr and ${\gamma}$'-ZnCr phase for the higher Cr content. In the Zn-Cr alloy fabricated by EB-PVD the ${\gamma}$'-ZnCr phase appeared clearly at 3 wt% Cr and it became the sole phase at 50 wt%Cr. The amount of η'-Zn phase decreased obviously with increasing Cr content when it exceeded 15 wt% Cr. The electrochemical measurement of the electroplated Zn-Cr film has shown corrosion potential of about -1000 mV. The current density of active region and the amount of dissolved Zn and Cr decreased significantly with increasing Cr content. The electrochemical characteristics of Zn-Cr alloy fabricated by EB-PVD have shown that the alloy of 50 wt% Cr had the highest corrosion potential(-500 mV) and the lowest critical passive current density than that of the electroplated.

Effects of GPS heat-treatment on microstructure of as-cast Co-Cr alloy (Co-Cr 주조합금의 미세구조에 미치는 GPS 열처리 효과)

  • Ryu, Jeong Ho;Lee, Ho Jun;Cho, Hyun Su;Paeng, Jong Min;Park, Jong Bum;Lee, Jung-Il
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.5
    • /
    • pp.263-267
    • /
    • 2017
  • The Co-Cr as-cast alloys are widely used in the manufacturing of orthopedic implants made with investment casting techniques because of its high strength, good corrosion resistance and excellent biocompatibility properties. Carbide precipitation at grain boundaries and interdendritic regions is the major strenthening mechanism in the as-cast condition. In this study, effects of GPS (Gas Pressured Sintering) heat-treatment on the microstructure and crystallinity of the as-cast Co-Cr alloy prepared by investment casting were investigated. It was confirmed that the content of metal carbide ($Cr_{23}C_6$) was increased in the grain boundary by using optical microscopy (OM), field-emission scanning electron microscopy (FE-SEM) and energy dispersive spectroscopy (EDS).

Effect of Heat Treatment on Interface Behavior in Ni-P/Cr Double Layer (열처리 시간에 따른 Ni-P/Cr 이중 도금 층의 계면 거동에 관한 연구)

  • Choi, Myung-Hee;Park, Young-Bae;Rhee, Byong-ho;Byon, Eungsun;Lee, Kyu Hwan
    • Journal of Surface Science and Engineering
    • /
    • v.48 no.6
    • /
    • pp.260-268
    • /
    • 2015
  • The thermal barrier coating (TBC) for inner wall of liquid-fuel rocket combustor consists of NiCrAlY as bonding layer and $ZrO_2$ as a top layer. In most case, the plasma spray coating is used for TBC process and this process has inherent possibility of cracking due to large difference in thermal expansion coefficients among bonding layer, top layer and metal substrate. In this paper, we suggest crack-free TBC process by using a precise electrodeposition technique. Electrodeposited Ni-P/Cr double layer has similar thermal expansion coefficient to the Cu alloy substrate resulting in superior thermal barrier performance and high temperature oxidation resistance. We studied the effects of phosphorous concentrations (2.12 wt%, 6.97 wt%, and 10.53 wt%) on the annealing behavior ($750^{\circ}C$) of Ni-P samples and Cr double layered electrodeposits. Annealing temperature was simulated by combustion test condition. Also, we conducted SEM/EDS and XRD analysis for Ni-P/Cr samples. The results showed that the band layers between Ni-P and Cr are Ni and Cr, and has no formed with heat treatment. These band layers were solid solution of Cr and Ni which is formed by interdiffusion of both alloy elements. In addition, the P was not found in it. The thickness of band layer was increased with increasing annealing time. We expected that the band layer can improve the adhesion between Cr and Ni-P.

Corrosion Characteristics of Ni-Cr and Co-Cr Alloy Used as a Dental Prosthesis and Its Adhesion to Porcelain (Ni-Cr과 Co-Cr 합금을 이용한 치과보철물의 부식 특성 및 도재 접합성)

  • Kim, Kijung;Choi, Byungki;Oh, Doorok;Choi, Byung-Sang
    • Corrosion Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.141-146
    • /
    • 2016
  • By using Ni-Cr and Co-Cr alloys, porcelain fused to metal (PFM) samples were prepared to examine the interface and the surface corrosion behavior. The potentiodynamic polarization analysis showed that the corrosion current density of Co-Cr alloy ($1.61{\times}10^{-6}A/cm^2$) was three times lower than that of Ni-Cr alloy ($4.83{\times}10^{-6}A/cm^2$) at room temperature. A dental prosthesis consisting of the porcelain fused to Ni-Cr alloy extracted from a patient after approximately four years of usage was examined to assess its resistance to corrosion. OM and SEM images of the metal part revealed a typical pitting corrosion. As compared to porcelain fused to Ni-Cr alloy having a thick layer (${\sim}10{\mu}m$) of oxide at the interface, a relatively thin oxide layer (less than $5{\mu}m$) was formed on Co-Cr alloy, indicating that the interface between Co-Cr alloy and porcelain may have a better adhesion strength than the interface between Ni-Cr alloy and porcelain.

Antioxidative Effects of Cornis fructus Extract on Chromium Trioxide Toxicity (Chromium Trioxide의 독성에 대한 산수유 추출물의 항산화 효과)

  • Seo, Young-Mi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.2
    • /
    • pp.170-176
    • /
    • 2018
  • This study examined the antioxidative effects of Cornis fructus (CF) extract on cultured C6 glioma cells. For this purpose, cytotoxicity analysis of chromium trioxide ($CrO_3$) was performed and the protective effects of the CF extract on $CrO_3$-induced cytotoxicity was examined after the C6 glioma cells were cultured for 48 hours. The antioxidative effects, such as electron donating activity (EDA) and lactate dehydrogenase (LDH) activity were also analyzed. In this study, $CrO_3$ decreased the cell viability in a dose dependent manner. The $XTT_{50}$ value was determined to be $33{\mu}M$ after the cells were treated for 48 hours at a concentrations of $20{\sim}40{\mu}M$ $CrO_3$. The catalase (CAT) antioxidant increased significantly the cell viability that had been decreased by $CrO_3$-induced cytotoxicity. Regarding the protective effect of the CF extract, the cell viability of the CF extract was increased significantly compared to that of $CrO_3$ only. In addition, the CF extract showed antioxidative effects, such as EDA and an inhibitory effect on the LDH activity. These findings suggest that the cytotoxicity of $CrO_3$ is correlated with oxidative stress, and the CF extract effectively prevented $CrO_3$-induced cytotoxicity through the antioxidative effects. In conclusion, natural products, such as the CF extract may be a useful therapeutic agent for the prevention or treatment of toxicity induced by heavy metals via oxidative stress.

K+ Ion-Selective PVC Membrane Electrodes with Neutral Carriers (중성운반체를 이용한 K+ 이온선택성 PVC막 전극)

  • Kim, Yong-Ryul;Cho, Kyoung-Sub;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.734-741
    • /
    • 1998
  • Electrode characteristics were studied in the interface between sample solutions and $K^+$ ion selective PVC membrane electrodes containing neutral carriers, dibenzo-18-crown-6(D18Cr6) and valinomycin(Val). The effect of doping of base electrolytes, the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, and concentration variation of sample solution on the response characteristics of electrode such as the measured Nernstian slope, the detection limit, the linear response range, and potentiometric selectivity coefficients, were studied. In order to synthesize the membrane D18Cr6 and Val as neutral carriers were used, and complex between the carrier and $K^+$ ions were used as active materials. PVC membrane electrodes were made of plasticizers (DBP, DOS, and DBS), the base electrolyte[potassium tetraphenylborate(KTPB)], and solvent(THF). The chemical structure of carrier D18Cr6 was best for electrode and ideal electrode characteristics were appeared especially in case of doping of TPB. The optimum carrier content was about 3.23 wt % in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the electrode characteristics was improved. But its characteristics were lowered below the optimum membrane thickness because of the elution of carrier, deterioration of membrane strength, etc. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were in the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

Continuous removal of heavy metals by coupling a microbial fuel cell and a microbial electrolytic cell

  • Xie, Guo R.;Choi, Chan S.;Lim, Bong S.;Chu, Shao X.
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.283-294
    • /
    • 2020
  • This work aims at studying the feasibility of continuous removal of mixed heavy metal ions from simulated zinc plating wastewaters by coupling a microbial fuel cell and a microbial electrolysis cell in batch and continuous modes. The discharging voltage of MFC increased initially from 0.4621 ± 0.0005 V to 0.4864 ± 0.0006 V as the initial concentration of Cr6+ increased from 10 ppm to 60 ppm. Almost complete removal of Cr6+ and low removal of Cu2+ occurred in MFC of the MFC-MEC-coupled system after 8 hours under the batch mode; removal efficiencies (REs) of Cr6+ and Cu2+ were 99.76% and 30.49%. After the same reaction time, REs of nickel and zinc ions were 55.15% and 76.21% in its MEC. Cu2+, Ni2+, and Zn2+ removal efficiencies of 54.98%, 30.63%, 55.04%, and 75.35% were achieved in the effluent within optimum HRT of 2 hours under the continuous mode. The incomplete removal of Cu2+, Ni2+ and Zn2+ ions in the effluent was due to the fact that the Cr6+ was almost completely consumed at the end of MFC reaction. After HRT of 12 hours, at the different sampling locations, Cr6+ and Cu2+ removal efficiencies in the cathodic chamber of MFC were 89.95% and 34.69%, respectively. 94.58%, 33.95%, 56.57%, and 75.76% were achieved for Cr6+, Cu2+, Ni2+ and Zn2+ in the cathodic chamber of MEC. It can be concluded that those metal ions can be removed completely by repeatedly passing high concentration of Cr6+ through the cathode chamber of MFC of the MFC-MEC-coupled system.

Properties and Environmental Effects Estimation of Grout Using Set Accelerating Agent Made From Calcium Aluminate and Viscosity Agent (칼슘알루미네이트계 급결재와 증점제를 사용한 그라우트의 특성 및 환경영향 평가)

  • Heo, Hyung Seok;Yi, Seong Tae;Noh, Jae Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.122-129
    • /
    • 2012
  • In this study, environmental problems(i.e., pH elevation and $Cr^{6+}$ detection) occurred by using the cement grout made from CA(calcium aluminate) were evaluated using viscosity agents(MC, chelate polymer). Ordinary portland cement and blaste-furnace slag cement were used by main materials and ACC(blended mixture of calcium aluminate) were used by accelerator for hardening of grout. In addition, viscosity agents were used for preventing pH elevation and heavy metal detection from grouting materials. From the results, it was noted that when chelate polymer was used, pH elevation and $Cr^{6+}$ detection were minimized. However, other cases showed higher pH elevation and $Cr^{6+}$ detection. At test 1 day, $Cr^{6+}$ detection with age presented over 97% of total value and, after that, additional increase was not distinct. As a result of this study, it was acknowledged that, to control pH elevation and heavy-metal (like $Cr^{6+}$) detection, the usage of BSC and chelate polymer is a very useful fact.

TiN and CrN Coating for the Increase of Abrasive Resistance of Extrusion Mold for Aluminium (알루미늄 압출용 금형의 내마모성향상을 위한 TiN, CrN 코팅)

  • Kim, Min-Suck;Kang, Seung-Min;Kim, Dong-Won;Kim, Sang-Ho
    • Journal of Surface Science and Engineering
    • /
    • v.42 no.6
    • /
    • pp.272-275
    • /
    • 2009
  • The purpose of this study is to show the friction and wear characteristic behaviors of TiN and CrN coated SKD61 which is applied to Al 6xxx extrusion mold material. The friction and wear characteristic behaviors of both coating layers were investigated by the reciprocating friction wear tester under atmospheric pressure and un-lubricated state. The processing parameters in this study were temperature (50 and $120^{\circ}C$) and load (3, 5, and 11 kgf). This study was carried out while comparing the coefficient of friction and microstructure of TiN and CrN coating layers on SKD61. The coefficient of friction of CrN became lower than that of TiN at all conditions. Therefore, CrN was suggested to be more advantageous than TiN for extrusion mold.