• Title/Summary/Keyword: $C_2H_2$ sensor

Search Result 418, Processing Time 0.029 seconds

Gas Sensing Properties of Pt Doped Fe2O3 Nanoparticles Fabricated by Sol-Gel Method (Sol-Gel 방법을 이용하여 제작된 Pt이 첨가된 Fe2O3 나노 입자의 가스 감지 특성)

  • Jang, Min-Hyung;Lim, Yooseong;Choi, Seung-Il;Park, Ji-In;Hwang, Namgyung;Yi, Moonsuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.5
    • /
    • pp.288-293
    • /
    • 2017
  • $Fe_2O_3$ is one of the most important metal oxides for gas sensing applications because of its low cost and high stability. It is well-known that the shape, size, and phase of $Fe_2O_3$ have a significant influence on its sensing properties. Many reports are available in the literature on the use of $Fe_2O_3$-based sensors for detecting gases, such as $NO_2$, $NH_3$, $H_2S$, $H_2$, and CO. In this paper, we investigated the gas-sensing performance of a Pt-doped ${\varepsilon}$-phase $Fe_2O_3$ gas sensor. Pt-doped $Fe_2O_3$ nanoparticles were synthesized by a Sol-Gel method. Platinum, known as a catalytic material, was used for improving gas-sensing performance in this research. The gas-response measurement at $300^{\circ}C$ showed that $Fe_2O_3$ gas sensors doped with 3%Pt are selective for $NO_2$ gas and exhibita maximum response of 21.23%. The gas-sensing properties proved that $Fe_2O_3$ could be used as a gas sensor for nitrogen dioxide.

The Structural and Optical Properties of ZnO : $Al_{2}O_{3}$ Compound by Reaction Sintering (Reaction Sintering에 의한 ZnO : $Al_{2}O_{3}$ 합성물의 구조 및 광학적 특성)

  • Kang, Byeong-Mo;Park, Gye-Choon;Yoo, Yong-Tek
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.218-224
    • /
    • 1998
  • 2nO and $Al_{2}O_{3}$ powder were weighed in 1 : 1 mole ratio and ball-milled in ethanol for 3 h. Dried mixture were pressed and then sintered at $900^{\circ}C{\sim}1200^{\circ}C$ for 3 h in vacuum($3{\times}10^{-5}$ Torr). According to XRD, remnant ZnO and $Al_{2}O_{3}$ not converted to $ZnAl_{2}O_{4}$ were observed up to $1100^{\circ}C$, which were completely changed to$ZnAl_{2}O_{4}$ ternary compound at $1200^{\circ}C$. Optical bandgap is calculated at 4.75 eV. With increasing sintering temperature, PL spectrums shifted to shorter wavelengths and are appeared 430nm at $1200^{\circ}C$.

  • PDF

Giant Magnetoimpedance in C067Fe4Mo1.5Si16.5B11 Metallic Glass Ribbon

  • Kuzminski, M.;Nesteruk, K.;Lachowicz, H.K.;Krzyzewski, A.;Yu, Seong-Cho;Lee, Hee-Bok;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • v.9 no.2
    • /
    • pp.47-51
    • /
    • 2004
  • Giant magneto-impedance (GMI) effect in zero-magnetostrictive Co-based amorphous ribbons samples in their as-quenched and stress-released states as well as with intentionally induced magnetic anisotropy were investigated. Magnetic and impedance properties of the samples exhibiting different anisotropy were compared and the optimum operation conditions for the studied samples from the view-point of their utilization as a sensor element have been determined. A design of a model of magnetic field sensor and characteristics of the constructed prototype are presented.

A Development of Stroke Sensing Cylinder for Position Control Using Magnetic Sensor (I) (자기센서를 이용한 위치제어용 스트로크 측정 실린더 개발(I))

  • Lee, M.C.;Choi, Y.J.;Lee, M.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.136-144
    • /
    • 1996
  • We developed a part of stroke sensing cylinder for position control of automatic excavator and its measurement system. In this paper, for development of stroke sensing cylinder, we consist of 2-axis control instrument system with Hall sensor. A performance of piston rod with magnetic scales is evaluated by the developed measurement system. Furthermore, the position control for good performance of instrument system is achieved by a sliding mode control which is a new method diminishing the chattering in that control by setting 2-dead band along the swtching line. The unknown parameters for sliding mode control are estimated by the signal compression method.

  • PDF

Detecting Characteristics of Catalytic Combustible Gas Sensor (접촉연소식 가스 센서의 검지특성)

  • 박찬원;원창섭;유영한;안형근;한득영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.865-870
    • /
    • 2000
  • In this paper, catalytic combustible gas sensor was fabricated and tested under flammable gases such as CH$_4$and $C_4$H$_{10}$by using Pt coil as a heater and/or temperature sensing element. Fine $Al_2$O$_3$powder was used for a bead and Pt, Pd noble metal powder for a catalyst. Resistance variation of Pt wire was traced by the changes of the gas concentrations in a chamber. Output voltage was then monitored to obtain the gas concentration from the resistance variation. In this experiment, MgO was used to protect cracks in the based and TiO$_2$to increase the sensitivity of the sensors. Water glass was also added to enhance the selectivity to the combustible gases.s.

  • PDF

A Study on the Prediction of Die Wear Based on Piezobolt Sensor Measurement Data in the Trimming Process of an Automobile Part (피에조 볼트 측정 데이터에 기반한 자동차 부품 트리밍 공정에서의 금형 마모 예측 연구)

  • Kwon, O.D.;Moon, H.B.;Kang, G.P.;Lee, K.;Hur, M.C.
    • Transactions of Materials Processing
    • /
    • v.31 no.2
    • /
    • pp.103-108
    • /
    • 2022
  • Systematic quality control based on real time data is required for modern factories. This study introduced a method of predicting punch wear in the trimming process of automobile parts. Based on monitoring data of the mass production process using a bolt-type piezo sensor, it was shown that precursor symptoms of die wear could be predicted from the change in load pattern with respect to production volume. The load pattern that changed according to the wear of the die was verified by numerical analysis.

$NO_2$ gas sensing properties of $SnO_2$ thin films dopped with Pd and CNT (Pd 및 CNT 첨가에 따른 $SnO_2$ 박막의 이산화질소 감지특성)

  • Kim, H.K.;Lee, R.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.4
    • /
    • pp.101-106
    • /
    • 2008
  • The $SnO_2$ thin films doped with Pd and CNT as $NO_2$ gas sensor were prepared by spin coating and then the $NO_2$ gas response of these films were evaluated under $1ppm{\sim}5ppm\;NO_2$ concentration and operating temperature of $200^{\circ}C$. It was found that the sensor resistance was increased with $NO_2$ exposure and $NO_2$ concentration. The 3wt% Pd doped sample showed a sensitivity of 26.5 which was 10 times higher than that of pure $SnO_2$. And also the sensitivity of CNT doped sample increased with CNT content and it had 72 when 0.225 wt% of CNT was added under 5ppm $NO_2$ concentration.

  • PDF

Material and Sensing Properties of SnO2 prepared by Sol-Gel Methods (Sol-Gel법에 의한 SnO2의 물성 및 센싱 특성)

  • Park, Bo-Seok;Hong, Kwang-Joon;Kim, Ho-Gi;Park, Jin-Seoung
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.327-334
    • /
    • 2002
  • Fine particles of $SnO_2$ were fabricated by the sol-gel powder processing using tine(II) chloride dihydrate($SnCl_2{\cdot}2H_2O$) and ethanol($C_2H_5OH$) as raw materials. The powders were investigated about the properties and electrical sensing. Gel powders were fabricated by drying of sol at $120^{\circ}C$ after aging 72hrs and 168hrs. The amount of $SnO_2$ phase was increased below $600^{\circ}C$ due to the elimination of volatile components, and the $SnO_2$ phase was almost completed by the heat treatment at $700^{\circ}C$ for 30min. The grain sizes were about 30nm below $700^{\circ}C$, and it showed the narrow distribution of the grain sizes. The specimens to measure electrical properties were fabricated by the thick film screen printing technique on the alumina substrates. The conductance of $SnO_2$ was showed the intrinsic behaviour of semiconducting ceramics above at $450^{\circ}C$. The constant conductance was observed in the temperature range of $200{\sim}450^{\circ}C$. The sensing properties of response time, recovery, and sensitivity of CO were improved with aging time.

Effect of Ultra-thin Catalyst Deposited upon $In_2O_3$ Thin Film on CO Sensitivity ($In_2O_3$ 박막위에 증착된 초박막 촉매가 CO의 검출 감도에 미치는 영향)

  • Lee, Hye-Jung;Song, Jae-Hoon;Kwon, Soon-Nam;Kim, Tae-Song;Kim, Kwang-Ju;Jung, Hyung-Jin;Choi, Won-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.430-439
    • /
    • 2000
  • $In_2O_3$-based thin film sensor with 500-600 nm thick was fabricated for the detection of CO gas by rf magnetron sputtering. In order to improve both sensitivity to CO gas and selectivity to hydrogen gas containing -CH, ultra-thin transition metal Co catalyst was sputtered over $In_2O_3$ thin film and annealed at $500^{\circ}C$. Sensitivity to CO was maximum at the thickness of Co 2.1 nm and $300^{\circ}C$, and that to $C_3H_8$ was at the thickness of Co 1.4 nm and $350-400^{\circ}C$. From the x-ray photoelectron spectroscopy (XPS) result, ultra-thin Co was existed into CoO covered with $Co_2O_3$ on $In_2O_3$ particles, and thus p-n junction of $In_2O_3(n-type)$-CoO(p-type) was thought to be formed. In this p-n junction type sensors, sensing mechanism with reducing gases can be explained by the variation of depletion layer thickness formed in the interface.

  • PDF

Preparation and Clinical Application of pH-ISE(Ion Selective Electrode) Based on Tribenzylamine Ionophore (Tribenzylamine Ionophore를 이용한 pH-ISE의 제조 및 임상응용)

  • Cho, Dong-Hoe;Park, Chung-Oh
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • The pH-ISE(ion selective electrode) based on tribenzylamine as a hydrogen ion carrier was prepared and its electrochemical characterization was studied. It responded linearly to hydrogen ions in the range of pH 3.1 - pH 11.0 and the Nernstian slope showed 55.0 mV/pH (at $20{\pm}0.2^{\circ}C$), it also showed a fast response time of 8 sec. When it was directly applied to human blood(pH 6.0-8.5), we could get the same satisfying results. A good reproducibility and stability were shown with the precision of 2 mV (${\pm}0.1$). The pH-ISE based on tribenzylamine exhibited biocompatibility in clinical applications.

  • PDF