• Title/Summary/Keyword: $CO_2$ laser

Search Result 987, Processing Time 0.029 seconds

Transoral $CO_2$ Laser Microsurgery for Glottic Carcinoma (성대암에서 $CO_2$ 레이저를 이용한 경구강절제술)

  • Chung, Phil-Sang;Moon, Tae-Hyun
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.1
    • /
    • pp.20-26
    • /
    • 2010
  • Transoral $CO_2$ Laser Microsurgery of glottic Carcinoma is replacing external approaches. The qualify of life after surgery for laryngeal cancer may be as important as complete resection of the tumor for patient. Transoral $CO_2$ laser cordectomy for the management of early laryngeal cancer has advantages with regard to oncological results, preservation of laryngeal functions, morbidity and cost in comparison to those of open surgery or radiation therapy. Moreover, transoral laser surgery can be a useful choice as a salvage surgery in radiation therapy failed early glottic cancer. A classification of laryngeal endoscopic cordectomies which included eight different types was described by the European laryngological Society in 2000. We will also introduce type VI which was newly proposed recently.

  • PDF

Temperature change in pulp chamber of teeth by $CO_2$ laser irradiation ($CO_2$ 레이저 광의 조사 조건에 따른 치아의 치수강내 온도변화)

  • 엄효순
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.45-48
    • /
    • 1990
  • CO2 laser beam was focused by a ZnSe lens onto the center of the occlusal surface f extracted lower molars. K-type thermocouple was contacted with the pulp chamber and the changes of temperature in the during and after the laser irradiation were measured as function of the power of laser beam, the time of laser irradiation and thickness of the sample. An empirical formula for temperature effect was derived from the measured data.

  • PDF

A Study on the Development of High Efficieny $CO_2$ Laser : Output Characteristics of Pulsed $CO_2$ Laser Using SMPS Method (고효율 $CO_2$ Laser 개발 연구 : SMPS 방식 펄스형 $CO_2$ Laser의 출력특성)

  • Chung, Hyun-Ju;Lee, Dong-Hoon;Nam, Gyung-Hoon;Kim, Do-Wan;Chung, Young-Hwan;Lee, Yu-Soo;Kim, Hee-Je;Cho, Jung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.730-734
    • /
    • 1999
  • In this study, it is the purpose to develope a cheap and compact repetitively pulsed $CO_2$ laser with pulse repetition rate range of 180 Hz. We used a SCR switched power supply as a high voltage pulsed supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate and gas pressure have been investigated. The experiment was done under the condition of total pressure of $CO_2, N_2$ and He from 4 Torr to 16 Torr and pulse repetition rate from 4 Hz to 180 Hz. As a result, the maximum average output was about 19.6W at the total pressure of 12 Torr and the pulse repetition rate of 180Hz.

  • PDF

Real time control special quality research for $CO_2$ laser's output change rate stability for accumulation style surgical operation rehabilitation of ventriculus that use Photosensor (Photosensor를 이용한 재활 치료형을 위한 $CO_2$ laser 의 출력변동율 안정을 위한 실시간 제어특성 연구)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.1015-1016
    • /
    • 2006
  • The important parameters deciding the fluctuation of Accumulation style surgical operation of ventriculus laser beam are smoothing capacitor, frequency and he characteristics of laser resonator. In this thesis, we control the fluctuation of medical $CO_2C$ laser in realtime by changing Duty-Ratio of IGBT and switching frequency with fixed the smoothing capacitor to improve the fluctuation of laser beam. We detect the light on laser resonator using a CdS photo sensor to improve ripple factor of laser beam and feedback fluctuated signals refined by a band pass filter into the control circuit to stabilize fluctuation actively. There is much to be desired in the realtime controlling technique of the light on Accumulation style surgical operation of ventriculus laser discharge tube in electrical signal. We propose switching control technique with microprocessor and photo sensing technique by controlling switch devices optimum operation and feedback signals detected by a photo sensor into the laser power supply in order to improve ripple factor of the $CO_2$ laser beam.

  • PDF

A Study on SS400 Cutting Characteristics using Continuous Wave Fiber Laser (연속파 파이버 레이저를 이용한 SS400의 절단 특성에 관한 연구)

  • Oh, Yong-Seok;Lee, Ka-Ram;Park, Eun-Kyeong;Yoo, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.644-650
    • /
    • 2012
  • This paper show the 2kW fiber laser cutting properties of SS400. The study was comparison of traditional 4kW $CO_2$ Laser cutting and 2kW Fiber laser cutting characteristics for the application of Industrial 2D Laser Cutting Machine. The laser used in this investigation was an IPG YLU-2000 multi-mode Ytterbium Fiber machine with a maximum power of 2000W and a wave length of 1070 nm. The laser was used in its Continuous Wave (CW) mode with an approximately top hat beam intensity distribution. Fiber laser high quality cuts at a large range of speeds (ranging from 2000 to 3800 mm/min) which has been obtained for the 2.3mm Sheet of SS400. 2kW power Fiber laser cut was able to max. 20mm sheets of SS400 (speed range from 650 to 850 mm/min). Fiber laser cutting used in conventional hole nozzle could cut 12mm SS400 but used in special dual cutting nozzle could cut 20mm SS400.

$CO_2$ Laser Treatment of Adult-onset Laryngeal Papillomatosis ($CO_2$ 레이저를 이용한 성인 후두유두종의 치료)

  • Oh, Jang-Keun;Yoon, Jun-Sik;Lee, Sang-Joon;Chung, Phil-Sang
    • Korean Journal of Bronchoesophagology
    • /
    • v.13 no.2
    • /
    • pp.45-49
    • /
    • 2007
  • Background and Objective : Laryngeal Papillomatosis (LP) is the most common benign neoplasm of the larynx, but it tend to recur and it makes eradicating difficult. Meticulous $CO_2$ laser excision has been the most effective treatment to date. This article analyzes the clinical feature and therapeutic results of 42 LP patients who were undergone $CO_2$ laser excision. Methods : Forty two patients with recurrent LP were treated with $CO_2$ laser. And their medical records were reviewed retrospectively. Demographics, chief complaints at onset, initial distribution of papillomas, number of operations performed on each patient, and current results were evaluated. Results : Male in their twenties and forties are dominant in number in patient number. Most common site was anterior one thirds (69%) of glottis area (86%). LP recurred in 17 cases (40%), and in 4 cases, the lesion extended over the original margin. Patients were undergone surgery $1.62{\pm}0.87$ times, $2.53{\pm}0.72$ in recurred cases. Mean relapsing time was 6 momths (from 1momth to 8years). Ant. laryngeal web occurred in 2 cases (4.8%) and 1 case was combined with squamous cell carcinoma. Conclusion : Meticulously performed $CO_2$ laser excision can achieve significant voice and airway improvement and clinical cures. The $CO_2$ laser through microdirect laryngoscopy allows more precise and bloodless removal of papillomas.

  • PDF

High power $CO_2$ laser beam welding for low carbon steels (저탄소강의 고출력 $CO_2$ 레이저 빔 용접)

  • 김재도
    • Journal of Welding and Joining
    • /
    • v.7 no.4
    • /
    • pp.12-21
    • /
    • 1989
  • Laser beam welding parameters have experimentally investigated, using a continuous wave 3kW $CO_2$ laser with the various travel speeds, beam mode and laser beam power in low carbon steels. An optimum position of focus and the effect of shielding gas on penetration depth with varying the flow range of 0.5 to 5.1m/min have been combined to investigate the effect of laser power and travel speed on penetration depth and bead width. It is found that the optimum position of focus in 3kW class laser is 0.5 to 1.5mm below the surface of the material. The flow rate of shielding gas affects the penetration depth and He is more effective than Ar. The penetration depth in laser welds of low carbon steels is between two and four times of the bead width. Laser beam welding of butt joints in 2mm thick carbon steel has been carried out to establish a weldability lobe. The lobe indicating acceptable welding conditions is introduced.

  • PDF

CO2 Laser Scribing Process of Soda Lime Glass (소다석회유리의 CO2 레이저 스크라이빙 가공)

  • Kang, Seung-Gu;Shin, Joong-Han
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.74-81
    • /
    • 2019
  • This study reports the CW $CO_2$ laser scribing of soda lime glass. In this study, scribing experiments are carried out at different laser powers, scan speeds, and focal positions to investigate the effect of the process parameters on the interaction characteristics between a laser beam and glass. In particular, the interaction characteristics are analyzed and described with the input laser energy per unit length. According to the experimental results, the damage threshold for the glass surface was found to exist between 0.072 and 0.08 J/mm. The input laser energy in this region induced partial melting of the surface and grain-shaped cracks. These cracks tended to increase as the input laser energy increased. At the laser input energy larger than 1 J/mm, a huge crack propagating along the scan direction was produced, and the volume below the scribed area was fully melted. The growth of this crack finally resulted in the complete cutting of the glass at the input laser energy above 8 J/mm. It was found that both the width and depth of the scribed line increased with increasing input laser energy. For the beam focusing at the rear surface, the width of the scribed line varied irregularly. This could be ascribed to the increased asymmetry of the beam intensity distribution when the laser beam was focused at the rear surface. Under this condition, a large burr was only produced on one side of the scribed line.

Power stabilization of a slab CO2 laser by using the Opto-Hertzian effect (Opto-Hertzian 효과를 이용한 고주파 여기식 슬랩 CO2 레이저의 출력 안정화)

  • 최종운;우삼용;김규식;이영우
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.337-342
    • /
    • 2004
  • Laser optical power stabilization of a radio frequency excited $CO_2$ slab laser using the opto-Hertzian effect generated from the laser itself is achieved on the peak of the Doppler broadened gain curve. The opto-Hertzian signal was generated by a modulation of the optical flux circulating inside the laser cavity from a variation in the cavity length caused by the vibrations of the PZT. The opto-Hertzian signal is directly coupled from a RE discharge chamber via a loop antenna into a detector and applied to a lock-in stabilizer as an reference signal. The power stability of an RF excited slab laser is estimated to be better then 0.2%.